비선형의 정도에 따른 Boussinesq 모형의 특성을 비교하기 위해 약비선형 모형인 MIKE21 BW 모듈과 완전비선형 모형인 FUNWAVE 모형을 이용하여 수치실험을 수행하였다. 진폭별 조파실험, 심해 파형경사별 천수실험 그리고 사주 지형상의 파랑 전파실험을 수행하였고, 이상의 실험을 통해 비선형성이 부각되는 천해역에서 비선형 모형의 중요성을 확인하였다. 특히 완전 비선형 모형이 약비선형 모형에 비해 비대칭 파형의 재현성이 우수하고, 천수현상에 따른 파고의 증가가 상대적으로 크게 나타나는 모형 간 특성을 확인하였다.
Membrane bio-reactor (MBR) has several advantages over the conventional activated sludge process, including a high biomass, low sludge production, and better permeate quality. Therefore, the MBR have gained popularity for municipal and industrial wastewater treatment. However the MBR usually were used for sewage and low streng th wastewater treatment because of membrane fouling problem and limitation of oxygen transfer into biomass. In this study, the hybrid process combining MBR and pure oxygen was tested for high strength organic wastewater treatment in the COD loading range from 2 to $10kgCOD/m^3{\cdot}day$. The hybrid process, membrane coupled pure oxygen high compact reactor (MPHCR), had been operated for one year and operation parameters, the effect of COD loading, MLSS concentration and the location of membrane module were studied for membrane fouling characteristic. Also membrane resistance test and the component of foulant was analyzed to investigate what is specific foulant in the MBR.
침적식 부직포 막분리와 생물학적처리를 조립한 본 연구시스템을 합성폐수에 적용 실험한 결과 다음과 같은 결론을 얻을 수 있었다. 1. 부직포는 기존 여과막보다 공극이 크므로 부직포 모율을 하루정도 침적한 후 생물여과막이 형성된 후 처리수가 안정됨으로 장치의 설치후 하루이상 경과한 후 가동되어야 한다. 2. 수리학적 체류시간, 부하량등의 변화에도 유기물 제거율은 평균 $COD_{Cr}$ 86.0%, $COD_{Cr}$ 90.0%, BOD 95.2%를 나타내었으며, 유출수 SS은 평균 6.2mg/l이었다. 3. 플럭스는 운전 초기 및 높은 압력에서 감소율이 크게 나타났으며 흡입압 $21{\sim}25cmHg$(약 30kpa)에서 $0.124m^3/m^2day$로 안정되었다. 4. 본 시스템의 단위체적당 처리량을 증가시키기 위한 적정한 부직포막의 선정 및 막면의 증가와 부직포 표면의 생물여과막의 조절을 위한 계속적인 연구가 필요하다고 사료된다.
본 연구에서는 사인파형 투과유속 운전방식을 중공사형 분리막에 적용하여 운전시간에 따른 막간차압(TMP)을 측정하였다. 유효 막면적이 $100cm^2$이고 공칭 세공크기가 $0.45{\mu}m$인 중공사막 모듈을 MLSS 5,000 mg/L 활성슬러지 용액으로 투과 실험하였다. 연속적인 단계별 투과유속 변화법으로 임계 투과유속을 측정하였으며 그 값은 $26.6L/m^2{\cdot}hr$이었다. 여과운전/정지이완(FR), 정지이완시 역세척(FR/BW) 및 사인파형 투과유속 연속운전(SFCO) 방식에 따른 TMP를 측정하였다. 임계 투과유속보다 낮은 15, 20 및 $25L/m^2{\cdot}hr$에서는 SFCO 운전방식이 FR 및 FR/BW에 비하여 효과적이었다. 그러나 임계 투과유속 이상에서는 FR/BW 운전방식이 SFCO보다 효과적으로 막오염을 제어할 수 있음을 확인하였다.
알루미늄 호일 부식 실험을 이용하여 초음파 토양 세척 공정의 설계를 위한 기초 연구가 수행되었다. 36 kHz 초음파 발생 모듈이 하부에 장착된 대형 초음파 반응기에 파이렉스 재질의 소형 반응기를 위치시키고 글라스 비드 크기(1, 2, 4 mm), 파이렉스 반응기 내 글라스 비드 높이(5, 10, 15, 20 mm), 글라스 비드 위 물 높이(5, 10, 15, 20 mm) 등의 다양한 조건에서 실험을 진행하였다. 실험 결과, 글라스 비드의 입자 크기가 클수록, 글라스 비드 위 수위가 증가할수록 알루미늄 호일의 부식 정도가 크게 증가하였는데 이는 입자가 클수록 빈 공간이 많이 생겨 초음파 감쇠 현상이 덜 일어나게 되기 때문이며, 또한 수위가 증가할수록 동일한 에너지 유입 조건에서 초음파 캐비테이션 현상이 보다 활성화되기 때문으로 판단되었다. 그러나 글라스 비드를 지나면서 초음파 감쇠 현상이 심하게 일어나 알루미늄 호일의 부식 정도가 상대적으로 매우 약하게 확인되어 부식이 활발하게 일어나는 반응기 하부, 즉 심각한 초음파 감쇠 현상이 일어나지 않는 바닥 부분으로 입자들을 지속적으로 보낼 수 있는 기계적 교반 등의 방안이 제안되었다.
침지형 MBR 공정에서 막 오염과 플럭스 감소의 주요 원인인 케이크층에 의한 저항을 저감하기 위하여 분리막 모듈의 외부에 원통형 관을 도입하였다. 도입된 원통형관 안에 노즐과 산기관을 적용하여 공기 주입량에 따른 공기와 액체의 2상흐름(Two phase flow)중 slug 흐름을 유도하여 공기 방울에 의한 막세정의 효과를 비교 분석하였다. 실험결과 동일한 유량의 공기를 공급할 경우 노즐에서 발생한 공기방울이 원통형관으로 유입되면서 효율적인 slug 흐름을 형성으로 산기관을 사용한 공급 방식보다는 막오염 방지에 효과적이었음을 알 수 있었다. 그러나 노즐로 공급되는 공기의 유량을 최적화하지 않는다면 원통형 관의 벽 부분부터 활성슬러지 혼합액이 퇴적하게 되거나 막간에 슬러지가 퇴적되어 관 내부의 급격한 막힘 현상이 발생하여 일정시간이 경과하면, 오히려 산기관보다 급격한 막오염 현상을 나타냄을 알 수 있었다. 또한 원통형 관 내부에 침지된 분리막의 면적의 최적 비율, A$_m$/A$_t$가 비율이 존재하는 것을 확인할 수 있었다. 산기관의 경우에는 A$_m$/A$_t$ 비율이 0.27일 때 최소화된 막오염이 관찰된 반면에, 노즐의 경우에는 A$_m$/A$_t$ 비율이 0.55일 때 막오염이 최소값을 보였다. 따라서 상승하는 공기방울에 의한 막오염 저감효과는 관 내부의 중공사막이 차지하고 있는 비율, A$_m$/A$_t$에 크게 의존하고 있으며, 산기관과 노즐의 경우 그 최적비율은 각각 다름을 알 수 있었다.
중공사막의 일단이 자유롭게 움직여 막 오염 현상을 줄일 수 있도록 고안된 침지형 프리엔드 중 공사막 모듈에 아주 짧은 주기로 역세를 실시하는 역충격을 적용하여 중공사막의 기초 오염 특성을 조사하였다. 본 연구에 사용된 막은 폴리설폰(PS, polysulfone)과 폴리아크릴로니트릴(PAN, polyacrylonitrile) 재질의 내경 0.7mm, 외경 1.3mm, 분획분자량 50,000인 한외 여과막을 사용하여 모듈을 제작 후 MLSS 10,000mg/L의 반응조를 침지하였다. PS 중공사막의 역충격 유무에 따른 투과율과 압력 변화를 측정하였다. 역충격을 가하지 않은 경우, 모듈의 투과율은 초기 3시간 동안 급격히 감소하였고 150시간 이후에 일정한 투과율을 나타내었다. 역충격을 가한 모듈의 투과율 감소율은 현저히 줄어들었다. PS과 PAN 재질 중공사막의 역충격에 대한 영향을 15kPa에서 비교한 결과 초기 투과율은 PS 막이 19lmh, PAN 막이 16lmh이었다. 그러나 PS 막은 급격한 막 오염으로 인하여 압력이 30kPa까지 상승하였고 PAN 막은 15kPa에서 거의 일정하게 유지되었다. 160시간 이후 역충격을 멈추었을 때 PAN 막의 투과율은 역충격이 있을 때보다 더욱 감소하였고 PS 막은 역충격을 주었을 경우와 비슷한 투과율을 나타내었다. PAN 막은 역충격으로 인하여 막의 오염이 지연되고 있는 상태에서 역충격의 영향이 없어지므로 막의 오염이 계속적으로 생기는 것이고, PS 막의 경우는 초기의 급격한 막의 오염 때문에 역충격으로 인한 막오염 지연효과가 적었다.
본 연구의 목적은 도시 하수처리를 위한 막결합형 $A_2O$공정에 관해 실제적인 정보를 얻고자 하는 것이다. 공경 $0.25\;{\mu}m$의 평판형 정밀여과막을 공기가 주입되는 호기조에 침지시켜 처리수는 저압으로 여과된다. 인공폐수를 대상으로 최적의 처리수질과 장기운전의 안정성 확보를 위한 내부반송율과 MLSS 농도 등의 최적 운전인자를 산정하고자 하였다. 내부반송은 각각 호기조에서 무산조로 반송한 것을 type 1, 무산조에서 혐기조로 반송한 것을 type 2라고 규정지었다. 플럭스는 15 LMH, type 1을 2Q로 고정하고 실험하였을 때 최적의 운전 조건은 MLSS 농도는 11,000 mg/L, type 2가 IQ로 나타났다. 이때, BOD $COD_{cr}$, T-N, T-P의 제거율이 각각 $97.3\%,\;94.2\%,\;64.0\%,\;63.0\%$로 타 내부반송율보다 효과적이었다.
본 연구는 침지형태로 운전되는 중공사막 결합형 생물반응기(HFMB) 시스템의 VOC 처리능력 및 안정성을 평가하기 위하여 수행되었다. 일차적으로 미생물이 없는 조건에서 VOC 물질전달을 알아보기 위한 abiotic test를 통해, 본 연구에서 사용한 HFMB는 미세기포를 이용한 산기관과 유사한 물질전달율을 나타냄을 확인하였다. 그러나 HFMB는 일반 산기관 시스템과는 달리 기체 유속과 중공사막 개수를 증가시켜 물질전달율을 더욱 증대시킬 수 있을 것으로 예측된다. 또한 반응조에 톨루엔 분해 미생물을 첨가하고 다양한 유입부하 조건에서의 기체상 톨루엔 제거 실험을 수행하였는데, 50, 100, $500\;g/m^3/hr$의 유입부하 조건에서 $70{\sim}80%$ 수준의 처리효율을 얻을 수 있었다. 추가적으로 수행된 분해능 실험에서는 최대 $800\;g/m^3/hr$ 이상의 분해능을 실험적으로 확인하여, 문헌에 제시된 기존 생물여과공법의 최대분해능($50{\sim}100\;g/m^3/hr$) 보다 월등히 높았다. 따라서 HFMB는 기존의 VOC 저감기술을 대치할 수 있는 친환경적인 기술이라고 판단된다.
This study was performed to evaluate SND(simultaneous nitrification and denitrification)efficiency, nitrogen removal efficiency and filtration function of non-woven fabric by using submerging MBR packed with granular sulfur covered with non-woven fabric filter. Synthetic wastewater was used as influent wastewater. Concentration of $NH_4{^+}-N$ in influent was maintained about 40 mg/L and the experiment was performed in four phases according to the flow rate. Nitrogen loading rate divided four phases ranging from $0.04 kg\;NH_4{^+}-N/m^3-day$ to $0.16 kg\;NH_4{^+}-N/m^3-day$. As a result, the maximum $NH_4{^+}-N$ removal rate was accomplished at $0.142 kg\;NH_4{^+}-N/m^3-day$ in nitrogen loading of $0.147 kg\;NH_4{^+}-N/m^3-day$. Nitrification efficiency was higher than 95% in all phases. $NO_3{^-}-N$ loading rate was adjusted ranging from $0.22 kg\;NO_3{^-}-N/m^3-day$ to $0.89 kg\;NO_3{^-}-N/m^3-day$. The maximum $NO_3{^-}-N$ removal rate was accomplished up to $0.71 kg\;NO_3{^-}-N/m^3-day$ in $NO_3{^-}-N$ loading of $0.89 kg\;NO_3{^-}-N/m^3-day$. The maximum $NO_3{^-}-N$ removal efficiency was 95% in $NO_3{^-}-N$ loading of $0.22 kg\;NO_3{^-}-N/m^3-day$. T-N removal rate was 90% and concentration of T-N in effluent was 3.7 mg/L in T-N loading rate of $0.039 kg\;NO_3{^-}-N/m^3-day$. In this study, TMP in reactor with and without non-woven fabric filter were observed to define fouling of hollow-fiber membrane module. Reaching time to standard washing pressure(22 cm Hg) of two reactors were 29 days with non-woven fabric But the reactor without non-woven fabric reached standard washing pressure only after 4 days. Accordingly, non-woven fabric was demonstrated the superiority as a filtration ability. With high nitrogen removal rate and decreasing of fouling of membrane, MBR packed with granular sulfur covered with non-woven fabric filter submerging in activated sludge aeration tank can be used as an advanced treatment process.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.