• 제목/요약/키워드: sub-pixel

검색결과 272건 처리시간 0.028초

기하학적 기법을 이용한 하이퍼스펙트럴 영상의 Linear Spectral Mixing모델에 관한 연구 (A Study on Linear Spectral Mixing Model for Hyperspectral Imagery with Geometric Method)

  • 장은석;김대성;김용일
    • 한국GIS학회:학술대회논문집
    • /
    • 한국GIS학회 2003년도 추계학술대회논문집
    • /
    • pp.23-29
    • /
    • 2003
  • Detection in remotely sensed images can be conducted spatially, spectrally or both [2]. If the images have high spatial resolution, materials can be detected by using spatial and spectral information, unless we can't see the object embedded in a pixel. In this paper, we intend to solve the limit of spatial resolution by using the hyperspectral image which has high spectral resolution. Therefore, the Linear Spectral Mixing(LSM) Model which is sub-pixel detection algorithm is used to solve this problem. To find class Endmembers, we applied Geometric Model with MNF(Minimum Noise Fraction) transformation. From the result of sub-pixel detection algorithm, we can see the detection of water is satisfied and the object shape cannot be extracted but the possibility of material existence can be identified.

  • PDF

In-Line Hologram for Plasma Diagnostics

  • Kim, Byungwhan;Jung, Jin-Su
    • Journal of the Optical Society of Korea
    • /
    • 제20권4호
    • /
    • pp.524-529
    • /
    • 2016
  • Diagnostic sensors are demanded during plasma processes. Holograms of plasma taken with laser light without a reference beam were used to monitor behaviors of charged particles produced in nitrogen plasma as a function of electrode temperature ranging between 50 and 300℃. Holograms were characterized as a function of the pixel sum and grayscale value. Pixel sum calculated in identified grayscale ranges strongly correlated with ion density and emitted light intensity measured with a langmuir probe and optical emission spectroscopy, respectively. The performance was further evaluated with data acquired as a function of N2 and NH3 flow rates and improved correlations were observed in the new grayscale range. The confirmed correlations indicate that a hologram is a viable means to diagnose behaviors of plasma particles such as ions. Underlying principles are discussed in view of particle and charge composing vacuum and light.

부화소 단위의 움직임 정보를 고려한 순차 주사화 (Sub-pixel Motion Compensated Deinterlacing Algorithm)

  • 박민규;최종성;강문기
    • 대한전자공학회논문지SP
    • /
    • 제40권5호
    • /
    • pp.322-331
    • /
    • 2003
  • HDTV(high-definition television)와 개인용 컴퓨터와 같은 다양한 매체의 발전에 따라 비월주사(interlaced scanning) 방식의 신호와 순차주사(progressive scanning) 방식의 신호 상호간의 변환에 대한 요구가 점점 늘어나고 있으며, 특히 비월주사 방식을 순차주사 방식으로 바꾸어주는 순차주사화(deinterlacing)가 활발히 연구되고 있다. 이러한 추세에 따라 본 논문에서는 부화소 단위의 움직임 정보를 이용한 순차주사화 알고리즘을 제안한다 이를 위해 움직임 추정과정에서 발생하는 부정확한 부화소 단위의 움직임 정보에 대하여 모델링하였다. 또한 집합이론(set-theory)에 근거하여 어떠한 사전 정보 없이 정규화값(regularization parameter)을 결정하여 영상들간의 부정확한 움직임에 의해 발생하는 에러를 최소화하였다. 본 논문에서 제안된 알고리즘은 실험을 통하여 검증 할 수 있었다.

Variable Sub-pixel Motion Vector Resolution Based on Block Mode Motion Estimation for H.264/AVC

  • Tran, Trung-Kien;Kim, Dae-Yeon;Lee, Yung-Lyul
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2008년도 하계종합학술대회
    • /
    • pp.807-808
    • /
    • 2008
  • In H.264, sub-pel motion estimation (ME) has strong effect when coding video sequences. 1/4-pel performs better at low bitrate while 1/8-pel gives better results at high bitrate. In this paper, a variable sub-pixel motion vector resolution based on block mode motion estimation method is proposed. Experiment results show that the proposed method can take the advantage of 1/4-pel at low bitrate and 1/8-pel at high bitrate. In addition to that, time is reduced from 14% to 53% compared to KTA1.3 with 1/8-pel motion vector (MV) resolution.

  • PDF

감광성 도판트를 이용한 풀컬러 구현 가능 반사형 콜레스테릭 액정 (Full Color Reflective Cholesteric Liquid Crystal using Photosensitive Chiral Dopant)

  • 박서규;김정수;조희석;권순범;유리레즈니코프
    • 한국전기전자재료학회논문지
    • /
    • 제21권5호
    • /
    • pp.474-480
    • /
    • 2008
  • In order to make full color cholesteric displays, color filter-less R, G, B sub-pixel structured cholesteric LC cells have been studied. To make R, G, B colors, UV induced pitch variant chiral dopant was added to cholesteric LC mixtures. The concentration of the photo-sensitive chiral dopant was adjusted so that the initial state showed blue color and the color was changed from blue to green and red with increase of UV irradiation to the cholesteric cells. To prevent the mixing of R, G, B reflective sub-pixel liquid crystals, separation walls were formed using negative photo resister in boundary area between sub-pixels, Through the optimization of the material concentrations and UV irradiation condition, vivid R, G, B colors were achieved.

A method for underwater image analysis using bi-dimensional empirical mode decomposition technique

  • Liu, Bo;Lin, Yan
    • Ocean Systems Engineering
    • /
    • 제2권2호
    • /
    • pp.137-145
    • /
    • 2012
  • Recent developments in underwater image recognition methods have received large attention by the ocean engineering researchers. In this paper, an improved bi-dimensional empirical mode decomposition (BEMD) approach is employed to decompose the given underwater image into intrinsic mode functions (IMFs) and residual. We developed a joint algorithm based on BEMD and Canny operator to extract multi-pixel edge features at multiple scales in IMFs sub-images. So the multiple pixel edge extraction is an advantage of our approach; the other contribution of this method is the realization of the bi-dimensional sifting process, which is realized utilizing regional-based operators to detect local extreme points and constructing radial basis function for curve surface interpolation. The performance of the multi-pixel edge extraction algorithm for processing underwater image is demonstrated in the contrast experiment with both the proposed method and the phase congruency edge detection.

Elemental Image Generation Method with the Correction of Mismatch Error by Sub-pixel Sampling between Lens and Pixel in Integral Imaging

  • Kim, Jonghyun;Jung, Jae-Hyun;Hong, Jisoo;Yeom, Jiwoon;Lee, Byoungho
    • Journal of the Optical Society of Korea
    • /
    • 제16권1호
    • /
    • pp.29-35
    • /
    • 2012
  • We propose a subpixel scale elemental image generation method to correct the errors created by finite display pixel size in integral imaging. In this paper, two errors are mainly discussed: pickup-and-display mismatch error and mismatch error between pixel pitch and lens pitch. The proposed method considers the relative positions between lenses and pixels in subpixel scale. Our proposed pickup method calculates the position parameters, generates an elemental image with pixels completely inside the lens, and generates an elemental image with border pixels using a weighted sum method. Appropriate experiments are presented to verify the validity of the proposed method.

An RGB to RGBY Color Conversion Algorithm for Liquid Crystal Display Using RGW Pixel with Two-Field Sequential Driving Method

  • Hong, Sung-Jin;Kwon, Oh-Kyong
    • Journal of the Optical Society of Korea
    • /
    • 제18권6호
    • /
    • pp.777-782
    • /
    • 2014
  • This paper proposes an RGB to RGBY color conversion algorithm for liquid crystal display (LCD) using RGW pixel structure with two-field (yellow and blue) sequential driving method. The proposed algorithm preserves the hue and saturation of the original color by maintaining the RGB ratio, and it increases the luminance. The performance of the proposed RGBY conversion algorithm is verified using the MATLAB simulation with 24 images of Kodak lossless true color image suite. The simulation results of average color difference CIEDE2000 (${\delta}E^*_{00}$) and scaling factor are 0.99 and 1.89, respectively. These results indicate that the average brightness is increased 1.89 times compared to LCD using conventional RGB pixel structure, without increasing the power consumption and degrading the image quality.

Analysis of lenticular 3D liquid crystal displays using 3D pixel simulator

  • Kim, Hwi;Jung, Kyoung-Ho;Yun, Hae-Young;Lee, Seung-Hoon;Kim, Hee-Sub;Shin, Sung-Tae
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.443-446
    • /
    • 2009
  • In this paper, an accurate ray-tracing based visual analysis method of lenticular 3D liquid liquid crystal display (LCDs) and some analysis results are presented. In the developed method, the geometric optics analysis is performed on the single 3D unit pixel of 3D lenticular LCD. It is shown that the display characteristics of 3D lenticular LCD panels of arbitrary size can be evaluated through the 3D unit pixel analysis. The analysis results of a few representative structures of 3D lenticular LCDs are compared.

  • PDF

유기 발광 소자 디스플레이를 위한 적외선 램프 소스를 활용한 열 전사 픽셀 패터닝 (Thermal Transfer Pixel Patterning by Using an Infrared Lamp Source for Organic LED Display)

  • 배형우;장영찬;안명찬;박경태;이동구
    • 센서학회지
    • /
    • 제29권1호
    • /
    • pp.27-32
    • /
    • 2020
  • This study proposes a pixel-patterning method for organic light-emitting diodes (OLEDs) based on thermal transfer. An infrared lamp was introduced as a heat source, and glass type donor element, which absorbs infrared and generates heat and then transfers the organic layer to the substrate, was designed to selectively sublimate the organic material. A 200 nm-thick layer of molybdenum (Mo) was used as the lightto-heat conversion (LTHC) layer, and a 300 nm-thick layer of patterned silicon dioxide (SiO2), featuring a low heat-transfer coefficient, was formed on top of the LTHC layer to selectively block heat transfer. To prevent the thermal oxidation and diffusion of the LTHC material, a 100 nm-thick layer of silicon nitride (SiNx) was coated on the material. The fabricated donor glass exhibited appropriate temperature-increment property until 249 ℃, which is enough to evaporate the organic materials. The alpha-step thickness profiler and X-ray reflection (XRR) analysis revealed that the thickness of the transferred film decreased with increase in film density. In the patterning test, we achieved a 100 ㎛-long line and dot pattern with a high transfer accuracy and a mean deviation of ± 4.49 ㎛. By using the thermal-transfer process, we also fabricated a red phosphorescent device to confirm that the emissive layer was transferred well without the separation of the host and the dopant owing to a difference in their evaporation temperatures. Consequently, its efficiency suffered a minor decline owing to the oxidation of the material caused by the poor vacuum pressure of the process chamber; however, it exhibited an identical color property.