• Title/Summary/Keyword: sub-frame control

Search Result 49, Processing Time 0.025 seconds

A WDM/SCM Multiple Access Protocol Using Node Grouping for Passive Double Star Optical Networks (수동이중성형 광통신망에서 노드 그룹핑을 이용한 WDM/SCM 다중접속 프로토콜 설계)

  • Yu, Jin-Tae;Lee, Myeong-Mun;Kim, Yong-Beom;Park, Si-U;Park, Jin-U
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.9
    • /
    • pp.652-662
    • /
    • 2001
  • A WDM/SCM multiple access protocol suitable for optical double star networks is proposed. A node-grouping scheme is employed in the protocol, which is accomplished by connecting some nodes through passive star sub-hubs forming a group. The resulting multiple groups in a network are then connected through a central passive star hub resulting in a passive double star network. Each group is pre-assigned a WDM channel as its home channel, and SCM channels are used to identify the packet reception at each node. [n the proposed protocol, the average packet delay is remarkably reduced since the frame consists of the number of groups rather than the number of network nodes. Furthermore, additional reduction of the average packet delay is achieved by limiting the propagation paths of control packets to the roundtrip between source nodes and sub-hub using a double star network. It is shown in the performance evaluations using analytic and simulation model that the proposed protocol has the advantages of the higher channel utilization and excellent network throughput and average packet delay characteristic.

  • PDF

A Study on Control of Fume for Various Parameters in CO2 Welding (CO2 용접에서 용접변수의 변화에 따른 용접흄 제어방법에 관한 연구)

  • Oh, Kwang-Joong;Kim, Hyun-Soo;Shon, Byung-Hyun;Jee, Hae-Sung
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.8 no.1
    • /
    • pp.76-87
    • /
    • 1998
  • The concentration of welding fume was measured by 221 welders themselves in chassis frame workplace of the manufactory from February, 1, 1996 to May, 31, 1997. Welding parameters were the welding current and the distance between helmet and arc. Those two optimum conditions were proposed by excess probability analysis using logistic regression, so the best position in the workplace was proposed considering two factors to control the welding fume. The results are as followings; 1) The excess proability of welding fume TLV was over 99% in above 260 Amperes of welding current and also in below 30cm of distanced between helmet and arc. 2) The equation from logistic regression analysis using SPSS/PC+5.02 had the welding current as a independent variable and the excess of welding fume TLV as a dependent variable (p<0.05). Logit(welding fume TLV) = 0.1296 ${\times}$ wlding currnet - 28.8750 3) The equation from logistic regression analysis using SPSS/PC+5.02 had the distance between helmet and arc as a independent variable and the excess of welding fume threshold limit value a, a dependent variable (p<0.05). Logit (welding fume TLV) = -0.6809 ${\times}$ distance between helmet and arc +25.1665 4) Considering both cases or 2) and 3). the result equation is following. (p<0.05). Logit (welding fume TLV) = 0.1346 ${\times}$ welding current -0.3859 ${\times}$ distance between helmet and arc -15.7382 5) The excess probability of welding fume threshold limit value was 100% in above 240 Ampere of welding current. Thus, below 220 Ampere can be suggested to reduce the 40% number of welders who have a excess welding fume threshold limit value. 6) The excess probability of welding fume TLV was 100% in below 34cm of distance between helmet and arc. Thus, over 38cm can be suggested to reduce the 33% number of welders who have a excess welding fume TLV. 7) Considering both 5) and 6) cases, first of all, the best welding current can be 200 Ampere to have a below 15% of welding fume excess probability for the welders who works in distance of 34-37cm. Secondly, to have a below 30% excess probability of welding fume TLV, the working distance must be over 38cm in 220 Ampere and 32cm in 200 Ampere. 8) To reduce the average exposure concentration of welding fume ($8.21{\pm}5.83mg/m^3$), the movable local exhaust system equipped with flexible hoods can be used.

  • PDF

The Effects of Using the Geometric Manipulative for the Development of Spatial Sense (기하 교구의 활용이 공간 지각 능력에 미치는 영향)

  • Park, Man-Goo;ChoiKoh, Sang-Sook;Jung, In-Chul;Kim, Eun-Young
    • Journal of the Korean School Mathematics Society
    • /
    • v.13 no.2
    • /
    • pp.303-322
    • /
    • 2010
  • The purpose of this study was to analyze the effects of using the geometric manipulative for the development of spatial sense and thus to find out a better mathematics teaching and learning method that could help develop students' spatial senses. The two fifth grade classes were randomly chosen as an experimental group (31 students) and a control group (32 students), respectively. This study implemented nonequivalent control group pretest-posttest design of quasi-experimental design. The test instrument used in this study was a spatial sense test. The pretest and posttest were implemented with the same instrument. In addition, their classes were observed and videotaped, and the data and their study activities were analyzed. In conclusion, first, the geometric manipulative-aided activities contributes to developing students' spatial senses and their two sub-factors involves perceptual consistency and perception of spatial relationship. Second, the activities of grasping the components of solid figures, sketches and development figures by using the geometric manipulative contribute to boost students' perceptual consistencies and their perceptions of spatial relationship.

  • PDF

A Minimum Energy Consuming Mobile Device Relay Scheme for Reliable QoS Support

  • Chung, Jong-Moon;Kim, Chang Hyun;Lee, Daeyoung
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.8 no.2
    • /
    • pp.618-633
    • /
    • 2014
  • Relay technology is becoming more important for mobile communications and wireless internet of things (IoT) networking because of the extended access network coverage range and reliable quality of service (QoS) it can provide at low power consumption levels. Existing mobile multihop relay (MMR) technology uses fixed-point stationary relay stations (RSs) and a divided time-frame (or frequency-band) to support the relay operation. This approach has limitations when a local fixed-point stationary RS does not exist. In addition, since the time-frame (or frequency-band) channel resources are pre-divided for the relay operation, there is no way to achieve high channel utilization using intelligent opportunistic techniques. In this paper, a different approach is considered, where the use of mobile/IoT devices as RSs is considered. In applications that use mobile/IoT devices as relay systems, due to the very limited battery energy of a mobile/IoT device and unequal channel conditions to and from the RS, both minimum energy consumption and QoS support must be considered simultaneously in the selection and configuration of RSs. Therefore, in this paper, a mobile RS is selected and configured with the objective of minimizing power consumption while satisfying end-to-end data rate and bit error rate (BER) requirements. For the RS, both downlink (DL) to the destination system (DS) (i.e., IoT device or user equipment (UE)) and uplink (UL) to the base station (BS) need to be adaptively configured (using adaptive modulation and power control) to minimize power consumption while satisfying the end-to-end QoS constraints. This paper proposes a minimum transmission power consuming RS selection and configuration (MPRSC) scheme, where the RS uses cognitive radio (CR) sub-channels when communicating with the DS, and therefore the scheme is named MPRSC-CR. The proposed MPRSC-CR scheme is activated when a DS moves out of the BS's QoS supportive coverage range. In this case, data transmissions between the RS and BS use the assigned primary channel that the DS had been using, and data transmissions between the RS and DS use CR sub-channels. The simulation results demonstrate that the proposed MPRSC-CR scheme extends the coverage range of the BS and minimizes the power consumption of the RS through optimal selection and configuration of a RS.

Aflatoxin B1 Detoxification by Aspergillus oryzae from Meju, a Traditional Korean Fermented Soybean Starter

  • Lee, Kyu Ri;Yang, Sun Min;Cho, Sung Min;Kim, Myunghee;Hong, Sung-Yong;Chung, Soo Hyun
    • Journal of Microbiology and Biotechnology
    • /
    • v.27 no.1
    • /
    • pp.57-66
    • /
    • 2017
  • Aflatoxins are classified as Group 1 (carcinogenic to humans) by the International Agency for Research on Cancer. In this study, a total of 134 fungal strains were isolated from 65 meju samples, and two fungal isolates were selected as potential aflatoxin $B_1$ ($AFB_1$)-biodetoxification fungi. These fungi were identified as Aspergillus oryzae MAO103 and A. oryzae MAO104 by sequencing the beta-tubulin gene. The two A. oryzae strains were able to degrade more than 90% of $AFB_1$ (initial concentration: $40{\mu}g/l$) in a culture broth in 14 days. The mutagenic effects of $AFB_1$ treated with A. oryzae MAO103 and MAO104 significantly decreased to 5.7% and 6.4%, respectively, in the frame-shift mutation of Ames tests using Salmonella typhimurium TA98. The base-substituting mutagenicity of $AFB_1$ was also decreased by the two fungi. Moreover, $AFB_1$ production by Aspergillus flavus was significantly decreased by the two A. oryzae strains on soybean-based agar plates. Our data suggest that the two $AFB_1$-detoxifying A. oryzae strains have potential application to control $AFB_1$ in foods and feeds.

Generic optimization, energy analysis, and seismic response study for MSCSS with rubber bearings

  • Fan, Buqiao;Zhang, Xun'an;Abdulhadi, Mustapha;Wang, Zhihao
    • Earthquakes and Structures
    • /
    • v.19 no.5
    • /
    • pp.347-359
    • /
    • 2020
  • The Mega-Sub Controlled Structure System (MSCSS), an innovative vibration passive control system for building structures, is improved by adding lead rubber bearings (LRBs) on top of the substructure. For the new system, a genetic algorithm is used to optimize the dynamic parameters and distributions of dampers and LRBs. The program uses various seismic performance indicators as optimization objectives, and corresponding results are compared. It is found that the optimization procedure for maximizing the energy dissipation ratio yields the best solutions, and optimized models have consistent seismic performances under different earthquakes. Seismic performances of optimized MSCSS models with and without LRBs, as well as the traditional Mega-Sub Structure model, are evaluated and compared under El Centro wave, Taft wave and 20 other artificial waves. In both elastic and plastic analysis, the model with LRBs shows significantly smaller story drift and horizontal acceleration than those of the other two models, and fewer plastic hinges are developed during severe earthquakes. Energy analysis also shows that LRBs installed in proper locations increase the deformation and energy dissipation of dampers, thereby significantly reduce the kinetic, potential, and hysteretic energy in the structure. However, LRBs do not have to be mounted on all the additional columns. It is also demonstrated that LRBs at unfavorable locations can decrease the energy dissipation for dampers. After LRBs are installed, the optimal damping coefficient and the optimal damping exponent of dampers are reduced to produce the best damping effect.

Burst Assembly Scheme based on SCM for Avoidance of Burst Collision in Optical Burst-Switched Networks (OBS 망에서 버스트 충돌 회피를 위한 SCM 기반의 버스트 생성 기법)

  • 이해정;김영천
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.6B
    • /
    • pp.538-547
    • /
    • 2004
  • Optical Burst Switched (OBS) networks usually employ one-way reservation by sending a burst control packet (BCP) with a specific offset time, before transmitting each data burst frame (BDF). Therefore, The quality of service may be degraded because contentions may lead to loss of BDFs. Especially, this phenomenon becomes more serious when burst size is longer. This necessitates an effective method of prevention to avoid burst collision in nodes. OBS networks can employ several methods to avoid such burst losses. One is that burst size is cut short to reduce burst loss probability during scheduling time. In this paper, we evaluate the burst generation and transmission using Sub-Carrier Multiplexting (SCM) in OBS networks. We propose an appropriate burst assembly architecture and transmission scheme based on SCM in OBS networks. The performance of SCM in OBS networks is examined in terms of number of Sub-Carriers per wavelength, burst loss probability, throughput, and total bandwidth of an optical fiber.

Single Degree of Freedom Hybrid Dynamic Test with Steel Frame Structure (강 뼈대 구조물의 단자유도 하이브리드 동적 실험)

  • Kim, Se-Hoon;Na, Ok-Pin;Kim, Sung-Il;Lee, Jae-Jin;Kang, Dae-Hung
    • Journal of the Korean Society for Railway
    • /
    • v.15 no.4
    • /
    • pp.413-421
    • /
    • 2012
  • The purpose of this study is to evaluate the structural dynamic behavior under hybrid control system. The hybrid test is to consider the interaction between the numerical and physical models. In this paper, single degree of freedom hybrid test was performed with one-bay, two-story steel frame structure. One column at the first floor was selected as a physical substructure and one actuator was used for applying the displacement load in horizontal direction. El Centro as earthquake waves was inputted and OpenSees was employed as the numerical analysis program for the hybrid real-time simulation. As a result, the total time of the hybrid test was about 9.6% of actual measured seismic period. The experimental results agreed well with the numerical one in terms of the maximum displacement. In nonlinear analysis, however, material nonlinearity made a difference of residual strain. Therefore, this hybrid dynamic test can be used to predict the structural dynamic performance more effectively than shaking table test, because of the spatial and economic limitations.

Hydraulic Characteristics of Deep and Low Permeable Rock Masses in Gyeongju Area by High Precision Constant Pressure Injection Test (고정밀도 정압 주입시험에 의한 경주 지역 대심도 저투수성 암반 수리특성 연구)

  • Bae, SeongHo;Kim, Hagsoo;Kim, Jangsoon;Park, Eui Seob;Jo, Yeonguk;Ji, Taegu;Won, Kyung-Sik
    • Tunnel and Underground Space
    • /
    • v.31 no.4
    • /
    • pp.243-269
    • /
    • 2021
  • Since the early 2010s, the social importance of research and practical projects targeting deep geological disposal of high-level nuclear waste, underground CO2 storage and characterization of deep subsurface by borehole investigation has been increasing. In this regard, there is also a significant increase in the need for in situ test technology to obtain quantitative and reliable information on the hydraulic characteristics of deep rock mass. Through years of research and development, we have independently set up Deep borehole Hydraulic Test System (DHTS) based on the key apparatuses designed and made with our own technology. Using this system, high precision constant pressure injection tests were successfully completed at the two 1 km boreholes located in Mesozoic granite and sedimentary rock regions, Gyeongju. During the field tests, it was possible to measure very low flow rate below 0.01 l/min with micro flow rate injection/control module. In this paper, the major characteristics of DHTS are introduced and also some results obtained from the high precision field tests under the deep and low permeable rock mass environment are briefly discussed.

A study on the Throughput Guarantee with TCP Traffic Control (전송률 보장을 위한 TCP 트래픽 제어에 관한 연구)

  • Lee, Myun-Sub
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.3
    • /
    • pp.303-308
    • /
    • 2016
  • Recently, as the rapid development of network technology and the increase of services required high bandwidth such as multimedia service, the network traffic dramatically increases. This massive increase of network traffic causes some problems such as the degradation of QoS and the lack of network resources and, to solve these problems, various research to guarantee QoS have been performing. Currently, The most representative method to guarantee the QoS is the DiffServ(: Differentiated Service). The DiffServ defines the AF(: Assured Forwarding) PHB(: Per Hop Behavior) and statistically ensures the throughput over the certain level of data rate. However, the TCP congestion control method that make up the majority of the Internet traffic is not fundamentally suitable to the DiffServ that guarantees the throughput without managing the individual flow. Therefore, in this paper, we present this mismatch through the simulation as an example and propose the solution by controlling the TCP of the terminal in the network. The proposed scheme utilizes the information of the reception window size included in the ACK frame and does not require any modification of the TCP algorithms currently in use.