• 제목/요약/키워드: sub-cooling

검색결과 437건 처리시간 0.033초

과냉각 축냉시스템을 적용한 쇼케이스의 운전 특성에 대한 실험적 연구 (Experimental Study on The Running Characteristics of Showcase Using Cold Storage System)

  • 이동원;김정배
    • 한국태양에너지학회 논문집
    • /
    • 제32권6호
    • /
    • pp.22-28
    • /
    • 2012
  • The purpose of this study was to show how tomaintain high efficiency and to use reasonably when being applied the cold-heat storage systems to the showcase. An experimental study was performed to manufacture the showcase system in a laboratory. Comparing the result at general operation condition with that of the new condition using ice storage system, this study showed the effects of the refrigerant sub-cooling, and with using inverter. Using ice storage system, the ice making process was operated during midnight being not needed the cooling of the showcase through the continuous running of the condenser unit. And then, the refrigerant was sub-cooled using the stored cold-heat after being discharged from the air cooling condenser during the day time. Through the experiments, the load transfer rate for the showcase using inverter and ice storage was estimated about 30.0%. And showed that the total power consumption of the showcase with inverter could be reduced about 37% than that of the showcase without inverter.

고압 축소형 연소기의 설계 및 연소효율 평가 (A Design of High Pressure Sub-scale Combustor and the Assessment of Combustion Efficiency)

  • 이광진;김홍집;류철성;한영민;최환석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2006년도 제27회 추계학술대회논문집
    • /
    • pp.169-174
    • /
    • 2006
  • 본 연구는 재생냉각형 고압 축소형 연소기 설계에 관한 것으로 이 연소기를 제작하기 전에 열유속측정을 위한 물냉각 고압 축소형 연소기를 제작하였다. 물냉각 고압 축소형 연소기의 연소시험결과 높은 연소성능 및 냉각성능이 검증된 설계 조건을 얻었고 이를 바탕으로 재생냉각형 고압 축소형 연소기의 형상을 설계하였다. 설계된 연소기의 형상은 제작이 완료된 후 연소시험을 수행하여 실용성을 검증 할 예정이다.

  • PDF

헬륨분사를 통한 액체산소 냉각의 이론적 고찰 및 해석과 시험의 비교 (Investigation of helium injection cooling to liquid oxygen chamber)

  • 권오성;조남경;정용갑;이중엽
    • 항공우주기술
    • /
    • 제5권2호
    • /
    • pp.134-142
    • /
    • 2006
  • 헬륨분사를 통한 극저온 추진제의 과냉각 방식은 발사체의 이륙 전에 액체산소의 bulk boiling을 억제하고 과냉각 상태를 유지하기 위한 효과적인 방법들 중의 하나이다. 본 자료에서는 이러한 헬륨 분사 냉각 시스템에 대한 이론적 고찰을 통해 열전달과 질량전달 조건을 이해하고, 해석 모델을 제시하였다. 해석 모델의 주요 특징은 유한 열전달과 무한질량전달 개념을 이용하여 분사 시스템을 표현한 것이다. 또한, 실험과 해석결과의 비교를 통하여 해석 모델을 검증하였으며, 헬륨 분사량의 변화, 탱크 압력의 변화 등 조건 변화에 따른 결과를 살펴보았다.

  • PDF

하나로 2 차 냉각탑의 공장분해수리 (Cooling Tower Overhaul of Secondary Cooling System in HANARO)

  • 박용철;이용섭;김양곤;정환성;임인철
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2714-2719
    • /
    • 2007
  • HANARO, an open-tank-in-pool type research reactor of 30 MWth power in Korea, has been operating normally since its initial criticality in February, 1995. For the last about ten years, A cooling tower of a secondary cooling system has been operated normally in HANARO. Last year, the cooling tower has been overhauled for preservative maintenance including fills, eliminators, wood support, water distribution system, motors, driving shafts, gear reducers, basements, blades and etc. This paper describes the results of the overhaul. As results, it is confirmed that the cooling tower maintains a good operability through a filed test. And a cooling capability will be tested when a wet bulb temperature is maintained about 28 $^{\circ}C$ in summer and the reactor is operated with the full power.

  • PDF

Metaheuristic-designed systems for simultaneous simulation of thermal loads of building

  • Lin, Chang;Wang, Junsong
    • Smart Structures and Systems
    • /
    • 제29권5호
    • /
    • pp.677-691
    • /
    • 2022
  • Water cycle algorithm (WCA) has been a very effective optimization technique for complex engineering problems. This study employs the WCA for simultaneous prediction of heating load (LH) and cooling load (LC) in residential buildings. This algorithm is responsible for optimally tuning a neural network (NN). Utilizing 614 records, the behavior of the LH and LC is explored and the captured knowledge is then used to predict for 154 unanalyzed building conditions. Since the WCA is a population-based algorithm, different numbers of the searching agents were tested to find the most optimum configuration. It was observed that the best solution is discovered by 500 agents. A comparison with five newly-developed benchmark optimizers, namely equilibrium optimizer (EO), multi-tracker optimization algorithm (MTOA), slime mould algorithm (SMA), multi-verse optimizer (MVO), and electromagnetic field optimization (EFO) revealed that the WCANN predicts the desired parameters with considerably larger accuracy. Obtained root mean square errors (1.4866, 2.1296, 2.8279, 2.5727, 2.5337, and 2.3029 for the LH and 2.1767, 2.6459, 3.1821, 2.9732, 2.9616, and 2.6890 for the LC) indicated that the most reliable prediction was presented by the proposed model. The EFONN, however, provided a more time-effective solution. Lastly, an explicit predictive formula was elicited from the WCANN.

6.6kV/200A급 유도형 한류기용 과냉질소 냉각시스템의 특성 (Characteristic of sub-cooled nitrogen cryogenic system for 6.6kV/200A Inductive Superconducting Fault Current Limiter)

  • 박동근;강형구;윤경용;주민석;김태중;고태국
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.234-236
    • /
    • 2003
  • The cryogenic system for inductive superconducting fault current limiter (SFCL) has been investigated recently. In this investigation, the sub-cooled nitrogen cryogenic system was adopted to enhance the performance of DC reactor for 6.6㎸/200A inductive SFCL. In sub-cooled nitrogen state at 64K, the critical current value and the thermal conductivity are larger than those of saturated nitrogen state at 77K and the electrical insulation capacitance should be remarkably enhanced. The solenoid type of 84mH superconducting DC reactor was fabricated and cooled down to 64K by using sub-cooled cooling method with GM-cryocooler and rotary pump. The fabrication techniques of cryogenic system and some experimental results such as cooling down characteristic are introduced in this study. Moreover, the sub-cooled nitrogen cryogenic system was detailedly introduced in this paper.

  • PDF

자연냉매 CO2를 이용한 고효율 LNG 냉동 트럭의 개발 (Development of a High Efficient LNG Refrigerated Truck using Natural Refrigerant CO2)

  • 정세진;곽헌섭;민호기
    • 한국가스학회지
    • /
    • 제24권6호
    • /
    • pp.77-82
    • /
    • 2020
  • 본 논문에서는 자연냉매로 주목받고 있는 이산화탄소(CO2) 를 이용하여 냉동탑차용 고효율 냉동시스템을 개발하였다. 기존의 디젤 차량을 LNG 차량으로 개조하여, 화물차의 배출가스를 개선하고, LNG 연료의 기화 잠열을 활용하여 CO2 냉동시스템의 효율을 높인 친환경적인 냉동탑차를 개발하였다. 그 결과 가스 쿨러에 LNG연료의 기화 잠열을 활용하여 냉동탑차의 COP를 144%로 향상 시켰다.

Nuclear Criticality Analyses of Two Different Disposal Canisters for Deep Geological Repository Considering Burnup Credit

  • Hyungju Yun;Manho Han;Seo-Yeon Cho
    • 방사성폐기물학회지
    • /
    • 제20권4호
    • /
    • pp.501-510
    • /
    • 2022
  • The nuclear criticality analyses considering burnup credit were performed for a spent nuclear fuel (SNF) disposal cell consisting of bentonite buffer and two different types of SNF disposal canister: the KBS-3 canister and small standardized transportation, aging and disposal (STAD) canister. Firstly, the KBS-3 & STAD canister containing four SNFs of the initial enrichment of 4.0wt% 235U and discharge burnup of 45,000 MWD/MTU were modelled. The keff values for the cooling times of 40, 50, and 60 years of SNFs were calculated to be 0.79108, 0.78803, and 0.78484 & 0.76149, 0.75683, and 0.75444, respectively. Secondly, the KBS-3 & STAD canister with four SNFs of 4.5wt% and 55,000 MWD/MTU were modelled. The keff values for the cooling times of 40, 50, and 60 years were 0.78067, 0.77581, and 0.77335 & 0.75024, 0.74647, and 0.74420, respectively. Therefore, all cases met the performance criterion with respect to the keff value, 0.95. The STAD canister had the lower keff values than KBS-3. The neutron absorber plates in the STAD canister significantly affected the reduction in keff values although the distance among the SNFs in the STAD canister was considerably shorter than that in the KBS-3 canister.

LiYSiO4: La 열형광체의 온도에 따른 열발광 특성 (Thermoluminescent Properties by the Cooling Temperature and Grain Size in the LiYSiO4 : La Phosphors)

  • 김영국
    • 한국재료학회지
    • /
    • 제19권9호
    • /
    • pp.494-498
    • /
    • 2009
  • The thermoluminescent phosphors of LiYSi$O_4$ containing rare earth metal(La) dopants of 1 wt.%5 wt.% were prepared, and their TL characteristics have been investigated as a function of parameters such as the doping level and the heating rate. The grain size and cooling temperature of the highly sensitive LiYSi$O_4$: La phosphors have been investigated. The glow curve of LiYSi$O_4$: La has two peaks ($P_1,\;P_2$), and the peak height ratio of the two peaks is called $P_2/P_1$; here, the main peak is $P_2$. Experimental results indicate that the peak height ratios of the glow curve for LiYSi$O_4$: La are clearly correlated with the grain size and cooling temperature. The maximum $P_2/P_1$ ratio 3.25, the maximum sensitivity was observed for a grain size between 100-150 ${\mu}m$. The intensity of the TL peak of the phosphors was linearly proportion to the dose of X-rays.

Study on the Dielectric Characteristics of Gaseous Nitrogen for Designing a High Voltage Superconducting Fault Current Limiter

  • Heo, Jeong-Il;Hong, Jong-Gi;Nam, Seok-Ho;Kang, Hyoung-Ku
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제14권2호
    • /
    • pp.28-31
    • /
    • 2012
  • The study on the dielectric characteristics of gaseous insulation medium is important for designing current leads of superconducting machines using a sub-cooled liquid nitrogen ($LN_2$) cooling method. In a sub-cooled $LN_2$ cooling system, the temperature of gaseous insulation medium surrounding current leads varies from the temperature of coolant to 300 K according to the displacement between the electrode system and the surface of sub-cooled $LN_2$. In this paper, AC withstand voltage experiments on gaseous nitrogen according to temperature are conducted. Also, AC withstand voltage experiments on gaseous nitrogen according to pressure, size of electrode, and gap length between two electrodes are performed. It is found that there is a functional relation between the electrical breakdown voltage and the field utilization factor (${\xi}$). As a result, the empirical formula for estimating an electrical breakdown voltage is deduced by adopting the concept of field utilization factors. It is expected that the experimental results presented in this paper are helpful to design current leads for a high voltage superconducting apparatus such as a superconducting fault current limiter (SFCL) using a sub-cooled $LN_2$ cooling system.