• Title/Summary/Keyword: stub curve

Search Result 18, Processing Time 0.027 seconds

Behavior of concrete columns confined with both steel angles and spiral hoops under axial compression

  • Zhou, Chunheng;Chen, Zongping;Shi, Sheldon Q.;Cai, Liping
    • Steel and Composite Structures
    • /
    • v.27 no.6
    • /
    • pp.747-759
    • /
    • 2018
  • This study proposed a new type of concrete column that was confined with both steel angles and spiral hoops, named angle-steel and spiral confined concrete (ASCC) column. A total of 22 ASCC stub columns were tested under axial compression to investigate their behavior. For a comparison, three angle-steel reinforced concrete (ARC) stub columns were also tested. The test results indicated that ASCC column had a superior mechanical performance. The strength, ductility and energy absorption were considerably increased due to the improvement of confinement from spiral hoops. The confinement behavior and failure mechanism of ASCC column were investigated by the analysis of failure mode, load-deformation curve and section-strain distribution. Parametric studies were carried out to examine the influences of different parameters on the axial compression behavior of ASCC columns. A calculation approach was developed to predict the ultimate load carrying capacity of ASCC columns under axial compression. It was validated that the predicted results were in well agreement with the experimental results.

A numerical investigation of the tensile behavior of the thread-fixed one-side bolted T-stubs at high temperature

  • You, Yang;Liu, Le;Jin, Xiao;Wang, Peijun;Liu, Fangzhou
    • Steel and Composite Structures
    • /
    • v.45 no.4
    • /
    • pp.605-619
    • /
    • 2022
  • The tensile behavior of the Thread-fixed One-side Bolt (TOB) at high temperatures was studied using the Finite Element Modeling (FEM) to explore the structural responses that could not be measured in tests. The accuracy of the FEM was verified using the test results from the failure mode, load-displacement curve as well as yielding load. Three typical failure modes of TOB connected T-stubs were observed, which were the Flange Yielding (FY), the Bolt Failure (BF) and the Coupling Failure mode (CF). The influence of the flange thickness tb and the temperature θ on the tensile behavior of the T-stub were discussed. The initial stiffness and the yielding load decreased with the increase of the temperature. The T-stubs almost lost their resistance when the temperature exceeded 700℃. The failure modes of T-stubs were mainly decided by the flange thickness, which relates to the anchorage of the hole threads and the bending resistance of flange. The failure mode could also be changed by the high temperature. Design equations in EN 1993-1-8 were modified and verified by the FEM results. The results showed that these equations could predict the failure mode and the yielding load at different temperatures with satisfactory accuracy.

The Life Expectancy Making Model for Construction Equipment (건설장비 수명결정 모델)

  • Lee, Yongsu;Kim, Cheol Min
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.5D
    • /
    • pp.453-461
    • /
    • 2012
  • Life analysis is conducted for economic analysis of equipment or facilities. The purpose of life analysis is to predict future indicators for scrapping construction equipment, and establish and utilize a wide variety of business strategies according to data predictions. First, this study shows the methods to figure out average life, life expectancy and life prediction of construction equipment and the analysis of life making methods, using survival curves. Second, the study proposes and examines the life expectancy making model depending on revenues and expenses. The result of the study reveals that the economic life of the same equipment varies with expenses, revenues and the initial cost. The life expectancy making model for construction equipment reflects respective management status for equipment and will help efficient management for companies.

A Study on the Prediction of Residual Strength of Concrete Filled Steel Tube Column without Fire Protective Coating by Unstressed Heating (비재하 가열에 의한 무내화피복 CFT 기둥의 잔존내력 예측에 관한 연구)

  • Kim, Gyu-Yong;Lee, Hyoung-Jun;Lee, Tae-Gyu;Kim, Young-Sun;Kang, Sun-Jong
    • Fire Science and Engineering
    • /
    • v.23 no.3
    • /
    • pp.31-39
    • /
    • 2009
  • Recently, fire resistance in high-rise building is becoming major problem socially. So it is need of hour to study on fire resistance in buildings. This study estimates fire resistance performance to utilized CFT (Concrete filled steel tube, below CFT) column in the high structure. But it is difficult quantitative evaluation about fire resistant performance of CFT. Therefore, this study made CFT specimen that determine the factor which is strength of concrete and then CFT column was exposed to heating controlled as closely as possible the ISO-834 standard fire curve. Also, tried to analyze internal temperature through nonlinear transient heat flow analysis. And, presumed extant compressive strength on the basis of this.

An Estimation on Average Service Life of Public Buildings in South Korea: In Case of RCC (우리나라 공공건물의 내용연수 추정: RCC를 중심으로)

  • Jung-Hoon Kwon;Jin-Hyung Cho;Hyun-Seung Oh;Sae-Jae Lee
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.46 no.1
    • /
    • pp.84-90
    • /
    • 2023
  • ASL estimation of public building is based on how appropriate the maximum age of the asset is derived based on the age record of the asset in the statistical data owned by public institutions. This is because we get a 'constrained' ASL by that number. And it is especially true because other studies have assumed that the building is an Iowa curve R3. Also, in this study, the survival rate is 1% as the threshold value at which the survival curve and the predictable life curve almost coincide. Rather than a theoretical basis, in the national statistical survey, the value of residual assets was recognized from the net value of 10% of the acquisition value when the average service life has elapsed, and 1% when doubling the average service life has elapsed. It is based on the setting mentioned above. The biggest constraint in fitting statistical data to the Iowa curve is that the maximum ASL is selected at R3 150%, and the 'constrained' ASL is calculated by the proportional expression on the assumption that the Iowa curve is followed. In like manner constraints were considered. First, the R3 disposal curve for the RCC(reinforced cement concrete) building was prepared according to the discarding method in the 2000 work, and it was jointly worked on with the National Statistical Office to secure the maximum amount of vintage data, but the lacking of sample size must be acknowledged. Even after that, the National Statistical Office and the Bank of Korea have been working on estimating the Iowa curve for each asset class in the I-O table. Another limitation is that the asset classification uses the broad classification of buildings as a subcategory. Second, if there were such assets with a lifespan of 115 years that were acquired in 1905 and disposed of in 2020, these discarded data would be omitted from this ASL calculation. Third, it is difficult to estimate the correct Iowa curve based on the stub-curve even if there is disposal data because Korea has a relatively shorter construction history, accumulated economic wealth since the 1980's. In other words, "constrained" ASL is an under-estimation of its ASL. Considering the fact that Korea was an economically developing country in the past and during rapid economic development, environmental factors such as asset accumulation and economic ability should be considered. Korea has a short period of accumulation of economic wealth, and the history of 'proper' architectures faithful to building regulations and principles is short and as a result, buildings 'not built properly' and 'proper' architectures are mixed. In this study, ASL of RCC public building was estimated at 70 years.

A Study on the Estimation of Average Service Life for New Technology Products-in Case of Solor-cell (신기술 제품의 ASL 추정-솔라셀 사례 중심으로)

  • Cho, Jin-Hyung;Lee, S.J.;Oh, H.S.;Baek, S.S.;Kim, O.J.;Kim, B.K.;Jeong, K.S.;Park, S.H.;Kwon, D.C.;Ko, J.H.;Ryu, J.H.;Shim, S.C.
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.37 no.4
    • /
    • pp.106-115
    • /
    • 2014
  • Until now, because a new product (or facility) launched in market has been retired from one year of age, we can have had ASL by stub-curve method by Iowa curve. Recently, many innovative products with important role in market like display and solar-cell etc. are more durable and, what are better, they have the constant variance in ASL because of their good quality. Of course, there are some ones like smart mobile phone with relatively big dispersion in ASL. Estimating ASL of products like display and solar-cell etc., the new approach is needed. In this paper a new method applied traditional Iowa curve with accelerated reliability test (indoor/outdoor) etc. is proposed.

Studies on Miniaturization and Notched Wi-Fi Bandwidth for UWB Antenna Using a Wide Radiating Slot (넓은 방사 슬롯을 이용한 초광대역 안테나의 소형화와 Wi-Fi 대역의 노치에 관한 연구)

  • Beom, Kyeong-Hwa;Kim, Ki-Chan;Jo, Se-Young;Ko, Young-Ho
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.2
    • /
    • pp.265-274
    • /
    • 2011
  • In this paper, it is studied on wide radiating slot antenna's miniaturization for ultra wide-band(UWB) technologies and notch structure to prevent interference between UWB systems and existing wireless systems for using Wi-Fi service of IEEE standards 802.11 a/n. Proposed antenna that wide slot is decreased from $\lambda/2$ to $\lambda/4$ length of resonant frequency has decreased by 72 % compared with conventional antenna. And optimized T-shaped CPW-fed stub has satisfied UWB bandwidth for 3.0~11.8 GHz. Then, creating 2-order Hilbert curve slot line in the stub's patch area, 4.9~5.6 GHz that centered frequency is 5 GHz is eliminated. Finally, the designed antenna constructed on FR4-epoxy has $20{\times}15\;mm^2$ dimension. The measured results that are obtained return loss under -10 dB through 3.2~11.8 GHz without Wi-Fi bandwidth, a linear phase characteristic, a stable group delay, and omnidirectional radiation patterns are presented.

Analysis of actively-confined concrete columns using prestressed steel tubes

  • Nematzadeh, Mahdi;Haghinejad, Akbar
    • Computers and Concrete
    • /
    • v.19 no.5
    • /
    • pp.477-488
    • /
    • 2017
  • In this paper, an innovative technique for finite element (FE) modeling of steel tube-confined concrete (STCC) columns with active confinement under axial compressive loading is presented. In this method, a new constitutive model for the stress-strain relationship of actively-confined concrete is proposed. In total, 14 series of experimental STCC stub columns having active confinement were modeled using the ABAQUS software. The results obtained from the 3D model including the compressive strength at the initial peak point and failure point, as well as the axial and lateral stress-strain curves were compared with the experimental results to verify the accuracy of the 3D model. It was found that there existed a good agreement between them. A parametric study was conducted to investigate the effect of the concrete compressive strength, steel tube wall thickness, and pre-stressing level on the behavior of STCC columns with active confinement. The results indicated that increasing the concrete core's compressive strength leads to an increase in the compressive strength of the active composite column as well as its earlier failure. Furthermore, a reduction in the tube external diameter-to-wall thickness ratio affects the axial stress-strain curve and the confining pressure, while increasing the pre-stressing level has a negligible effect on the two.