• Title/Summary/Keyword: strut

Search Result 626, Processing Time 0.02 seconds

A Study on Displacement Measurement Hardware of Retaining Walls based on Laser Sensor for Small and Medium-sized Urban Construction Sites

  • Kim, Jun-Sang;Kim, Jung-Yeol;Kim, Young-Suk
    • International conference on construction engineering and project management
    • /
    • 2022.06a
    • /
    • pp.1250-1251
    • /
    • 2022
  • Measuring management is an important part of preventing the collapse of retaining walls in advance by evaluating their stability with a variety of measuring instruments. The current work of measuring management requires considerable human and material resources since measurement companies need to install measuring instruments at various places on the retaining wall and visit the construction site to collect measurement data and evaluate the stability of the retaining wall. It was investigated that the applicability of the current work of measuring management is poor at small and medium-sized urban construction sites(excavation depth<10m) where measuring management is not essential. Therefore, the purpose of this study is to develop a laser sensor-based hardware to support the wall displacement measurements and their control software applicable to small and medium-sized urban construction sites. The 2D lidar sensor, which is more economical than a 3D laser scanner, is applied as element technology. Additionally, the hardware is mounted on the corner strut of the retaining wall, and it collects point cloud data of the retaining wall by rotating the 2D lidar sensor 360° through a servo motor. Point cloud data collected from the hardware can be transmitted through Wi-Fi to a displacement analysis device (notebook). The hardware control software is designed to control the 2D lidar sensor and servo motor in the displacement analysis device by remote access. The process of analyzing the displacement of a retaining wall using the developed hardware and software is as follows: the construction site manager uses the displacement analysis device to 1)collect the initial point cloud data, and after a certain period 2)comparative point cloud data is collected, and 3)the distance between the initial point and comparison point cloud data is calculated in order. As a result of performing an indoor experiment, the analyses show that a displacement of approximately 15 mm can be identified. In the future, the integrated system of the hardware designed here, and the displacement analysis software to be developed can be applied to small and medium-sized urban construction sites through several field experiments. Therefore, effective management of the displacement of the retaining wall is possible in comparison with the current measuring management work in terms of ease of installation, dismantlement, displacement measurement, and economic feasibility.

  • PDF

Performance of IPS Earth Retention System in Soft Clay (연약지반에 적용된 IPS 흙막이 시스템의 거동 특성)

  • Kim, Nak-Kyung;Park, Jong-Sik;Oh, Hee-Jin;Han, Man-Yop;Kim, Moon-Young;Kim, Sung-Bo
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.3
    • /
    • pp.5-13
    • /
    • 2007
  • The performance of innovative prestressed support (IPS) earth retention system applied in soft clay was investigated and presented. The IPS wale system provides a high flexural stiffness to resist the bending by lateral earth pressure, and transfers lateral earth pressure to strut supports. The IPS wale system provides a larger spacing of support than conventional braced and anchored systems. The IPS earth retention system was selected for temporary earth support in a building construction in North Busan area. The excavation was made 28.8 m wide, 52.0 m long, and 16.1 m deep through loose fill to soft clay. The IPS system consists of 650 mm thick slurry walls, and five levels of IPS wales and struts. Field monitoring data were collected including wall deflections at six locations, ground water levels at four locations, IPS wale deflections at thirty locations, and axial loads on struts at twenty locations, during construction. The IPS earth retention system applied in soft clay performed successfully within a designed criterion. Field measurements were compared with design assumptions of the IPS earth retention system. The applicability and stability of the IPS earth retention system in soft clay were investigated and evaluated.

Applicability of Partial Post-Tension Method for Deflection Control of Reinforced Concrete Slabs (RC슬래브의 처짐제어를 위한 상향긴장식 부분PT공법의 적용)

  • Lee, Deuck-Hang;Kim, Kang-Su;Kim, Sang-Sik;Kim, Yong-Nam;Lim, Joo-Hyuk
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.3
    • /
    • pp.347-358
    • /
    • 2009
  • Recently, it is getting into a good situation for the flat-plate slab system to be applied. The flat-plate slab without beam, however, is often too weak to control deflection properly compared to other typical slab-beam structures, for which the post-tension method is generally regarded as one of best solutions. The post-tension (PT) method can effectively control deflection without increase of slab thickness. Despite this good advantage, however, the application of PT method has been very limited due to cost increase, technical problems, and lack of experiences. Therefore, in order to reduce difficulties on applying full PT method under the current domestic circumstances and to enhance constructability of PT system, this research proposed the partial PT method with top jacking anchorage applied in a part of span as need. For the top jacking anchorage system, the efficiency of deflection control shall be considered in detail because it can vary widely depending on the location of anchorage that can be placed anywhere as need, and tensile stresses induced at back of the anchorage zone also shall be examined. Therefore, in this study, analysis were performed on the efficiency of deflection control depending on the location of anchorage and on tensile stresses or forces using finite element method and strut and tie model in the proposed top jacking anchorage system. The proposed jacking system were also applied to the floor slabs at a construction site to investigate its applicability and the analysis results of slab behavior were compared to the measured values obtained from the PT slab constructed by the partial PT method. The result of this study indicates that the partial PT method can be very efficiently applied with little cost increase to control deflection and tensile stresses in the region as a need basis where problem exists.

Recent Progress in Air Conditioning and Refrigeration Research -A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2000 and 2001- (공기조화, 냉동 분야의 최근 연구 동향 -2000년 및 2001년 학회지 논문에 대한 종합적 고찰 -)

  • 강신형;한화택;조금남;이승복;조형희;김민수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.12
    • /
    • pp.1102-1139
    • /
    • 2002
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2000 and 2001 has been done. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environment. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation of facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat, humidity was also interesting for comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing topics. Well developed CFD technologies were widely applied for developing facilities and their systems. (2) Most of papers related with heat transfer analysis and heat exchanger shows dealt with convection, evaporation, and channel flow for the design application of heat exchanger. The numerical heat transfer simulation studies have been peformed and reported to show heat transfer characteristics. Experimental as well as numerical studies on heat exchanger were reported, while not many papers are available for the system analysis including heat exchanger. (3) A review of the recent studies on heat pump system shows that performance analysis and control of heat pump have been peformed by various simulations and experiments. The research papers on multi-type heat pump system increased significantly. The studies on heat pipe have been examined experimently for change of working characteristics and strut lure. Research on the phase change has been carried out steadily and operation strategies of encapsulated ice storage tank are reported experimentally in several papers. (4) A review of recent studies on refrigeration/air conditioning system have focused on the system performance and efficiency for new alternative refrigerants. Evaporation and condensation heat transfer characteristics are investigated for tube shapes and new alternative refrigerants. Studies on components of refrigeration/air conditioning system are carried to examine efficiency for various compressors and performance of new expansion devices. In addition to thermophysical properties of refrigerant mixtures, studies on new refrigerants are also carried out, however research works on two-phase flow seemed to be insufficient. (5) A review of the recent studies on absorption cooling system indicates that heat and mass transfer phenomena have been investigated to improve absorber performance. Various experimental data have been presented and several simulation models have been proposed. A review of the recent studies on duct and ventilation shows that ventilation indices have been proposed to quantify the ventilation performance in buildings and tunnels. Main efforts have been focused on the applications of ventilation effectiveness in practice, either numerically using computational fluid dynamics or experimentally using tracer gas techniques. (6) Based on a review of recent studies on indoor thermal environment and building service systems, research issues have mainly focused on many innovative ideas such as underfloor air-conditioning system, personal environmental modules, radiant floor cooling and etc. Also, the new approaches for minimizing energy consumption as well as improving indoor environmental conditions through predictive control of HVAC systems, various activities of building energy management and cost-benefit analysis for economic evaluation were highlighted.

Paradoxical Upper Airway Obstruction and Central Sleep Apnea Developed After Anterior Cervical Spine Fusion (전방경추융합술 후 발생한 역설상기도폐쇄 및 중추성 수면 무호흡)

  • Lee, Sang Haak;Choi, Young Mee;Park, Ye Ree;Kang, Ji Ho;Kim, Young Kyoon;Kim, Kwan Hyoung;Song, Jeong Sup;Park, Sung Hak;Moon, Hwa Sik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.58 no.3
    • /
    • pp.295-298
    • /
    • 2005
  • We report a case of a 48-year-old man with a paradoxic upper airway obstruction and central sleep apnea that developed after an anterior cervical spinal fusion. Nine months before being admitted to this hospital, he was diagnosed with a herniated intervertebral disc between the 5th and 6th cervical spine, and the first operation was carried out. Two months later, a pseudoarthrosis has developed and a second operation, an anterior interbody fusion of the C5 and C6 using autogenous strut bone graft, was performed. After the second operation, he began to complain of snoring, excessive daytime sleepiness, insomnia, and a bizarre sound heard near the upper airway during breathing. Nasopharyngoscope and magnetic resonance imaging disclosed a paradoxical narrowing of the nasopharynx during expiration. On the overnight polysomnography, the apnea index was 8.7/h (central apnea, 7.0/h; obstructive apnea, 1.7/h). Nasal continuous positive airway pressure was applied, but he complained of pressure-intolerance, and laser-assisted uvulopalatoplasty was then performed. Two months after surgery, clinical symptoms as well as the apneas had improved markedly. We suggest that this paradoxic upper airway obstruction might be associated with the anterior cervical spinal surgery even though the mechanism is unclear. This case also emphasizes that an upper airway obstruction can contribute to the development of central sleep apnea.

Is It Appropriate to Insert Pedicle Screws at an Infected Vertebral Body in the Treatment of Lumbar Pyogenic Spondylodiscitis? (요추부 화농성 척추염의 수술적 치료: 이환된 추체에 척추경 나사 고정이 타당한가?)

  • Na, Hwa-Yeop;Jung, Yu-Hun;Lee, Joo-Young;Kim, Hyung-Do
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.5
    • /
    • pp.419-426
    • /
    • 2021
  • Purpose: In the surgical treatment of pyogenic lumbar spondylodiscitis, screw insertion at the affected vertebra has been avoided because of biofilm formation, and the risk of infection recurrence. The authors analyzed the success rate of infection treatment while minimizing the number of instrumented segments by inserting pedicle screws into the affected vertebrae. Therefore, this study examined the usefulness of this technique. Materials and Methods: From January 2000 to June 2018, among patients with pyogenic lumbar spondylodiscitis treated surgically, group A consisted of patients with pedicle screws inserted directly at the affected vertebrae (28 cases), and group B underwent fusion by inserting screws at the adjacent normal vertebrae due to bone destruction of the affected vertebral pedicle (20 cases). The classified clinical results were analyzed retrospectively. All patients were treated via the posterior-only approach, so the affected disc and sequestrum were removed. Posterior interbody fusion was performed with an autogenous strut bone graft, and the segments were then stabilized with pedicle screw systems. The hospitalization period, operation time, amount of blood loss, EQ-5D index, duration of intravenous antibiotics, and the clinical and radiological results were analyzed. Results: In group A, the number of instrumented segments, operation time, blood loss, and EQ-5D index at one month postoperatively showed significant improvement compared to group B. There were no significant differences in the duration of antibiotic use, hospitalization, radiological bone union time, sagittal angle correction rate, and recurrence rate. Conclusion: Minimal segmental fixation, in which pedicle screws were inserted directly into the affected vertebrae through the posterior approach, reduced the surgery time and blood loss, preserved the lumbar motion by minimizing fixed segments and showed rapid recovery without spreading or recurrence of infection. Therefore, this procedure recommended for the surgical treatment of lumbar pyogenic spondyodiscitis.