• Title/Summary/Keyword: structure type

Search Result 10,442, Processing Time 0.032 seconds

Study on the Optimal CPS Implant for Improved ESD Protection Performance of PMOS Pass Structure Embedded N-type SCR Device with Partial P-Well Structure (PMOS 소자가 삽입된 부분웰 구조의 N형 SCR 소자에서 정전기 보호 성능 향상을 위한 최적의 CPS 이온주입에 대한 연구)

  • Yang, Jun-Won;Seo, Yong-Jin
    • Journal of Satellite, Information and Communications
    • /
    • v.10 no.4
    • /
    • pp.1-5
    • /
    • 2015
  • The ESD(electrostatic discharge) protection performance of PPS(PMOS pass structure) embedded N-type silicon controlled rectifier(NSCR_PPS) device with different partial p-well(PPW) structure was discussed for high voltage I/O applications. A conventional NSCR_PPS standard device shows typical SCR-like characteristics with low on-resistance, low snapback holding voltage and low thermal breakdown voltage, which may cause latch-up problem during normal operation. However, our proposed NSCR_PPS devices with modified PPW_PGM(primary gate middle) and optimal CPS(counter pocket source) implant demonstrate the stable ESD protection performance with high latch-up immunity.

Influence of imperfectly bonded piezoelectric layer with irregularity on propagation of Love-type wave in a reinforced composite structure

  • Singh, Abhishek Kumar;Chaki, Mriganka Shekhar;Hazra, Bristi;Mahto, Shruti
    • Structural Engineering and Mechanics
    • /
    • v.62 no.3
    • /
    • pp.325-344
    • /
    • 2017
  • The present paper investigates the propagation of Love-type wave in a composite structure comprised of imperfectly bonded piezoelectric layer with lower fiber-reinforced half-space with rectangular shaped irregularity at the common interface. Closed-form expression of phase velocity of Love-type wave propagating in the composite structure has been deduced analytically for electrically open and short conditions. Some special cases of the problem have also been studied. It has been found that the obtained results are in well-agreement to the Classical Love wave equation. Significant effects of various parameters viz. irregularity parameter, flexibility imperfectness parameter and viscoelastic imperfectness parameter associated with complex common interface, dielectric constant and piezoelectric coefficient on phase velocity of Love-type wave has been reported. Numerical computations and graphical illustrations have been carried out to demonstrate the deduced results for various cases. Moreover, comparative study has been performed to unravel the effects of the presence of reinforcement and piezoelectricity in the composite structure and also to analyze the existence of irregularity and imperfectness at the common interface of composite structure in context of the present problem which serves as a salient feature of the present study.

Experimental Study on a Dolphin-Fender Mooring System for Pontoon-Type Structure (초대형 부유식 구조물의 돌핀-펜더계류시스템에 관한 실험연구)

  • Kim, Jin-Ha;Cho, Seok-Kyu;Hong, Sa-Young;Kim, Young-Shik
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.42 no.1 s.139
    • /
    • pp.43-49
    • /
    • 2005
  • in this paper a dolphin-fender moored pontoon-type floating structure in shallow water depth is studied focusing on mooring force. The pontoon-type floating structure is 500m long, 300m wide. The structure has partially non-uniform drafts of 2.0m and 3.0m. The employed mooring system is a guyed frame type dolphin-fender system. The 1/125 scale model fender system is made of rubber tube to have hi-linear load deflection characteristics. A series of model tests has been conducted focusing on motion and fender force responses in regular and irregular waves at KRISO's ocean engineering basin Non-linear numerical simulation of fender reaction force has been carried out and the results are compared with those of model tests. The simulated rigid body motion and mooring forces also have been compared with the test results.

A Study on Basic Characteristics of a Coplanar-type Transmission Line Employing Periodic Structure on Si RFIC (Si RFIC상에서 주기적 구조를 이용한 코프레너형 전송선로의 기본특성연구)

  • Joh, Han-Nah;Park, Young-Bae;Yun, Young
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.6
    • /
    • pp.964-973
    • /
    • 2008
  • In this study, a short-wavelength coplanar-type transmission line employing periodic ground structure (PGS) was developed for application to miniaturized on-chip passive component on Si Radio Frequency Integrated Circuit (RFIC). The transmission line employing PGS showed shorter wavelength and lower characteristic impedance than conventional coplanar-type transmission line. The wavelength of the transmission line employing PGS structure was 57 % of the conventional coplanar-type transmission line on Si substrate. Using the theoretical analysis. basic characteristics of the transmission line employing PGS (e.g., bandwidth. loss, impedance, and resonance characteristics) were also investigated in order to evaluate its suitability for application to a development of miniaturized passive on-chip components on silicon RFIC. According to the results. the bandwidth of the transmission line employing PGS was more than 895 GHz as long as T is less than 20${\mu}m$, and the resonance characteristic was observed in 1239 GHz, which indicates that the PPGM structure is a promising candidate for application to a development of miniaturized on-chip passive components on Si RFIC.

Effects on the ESD Protection Performance of PPS(PMOS Pass Structure) Embedded N-type Silicon Controlled Rectifier Device with different Partial P-Well Structure (PPS 소자가 삽입된 N형 SCR 소자에서 부분웰 구조가 정전기 보호 성능에 미치는 영향)

  • Yang, Jun-Won;Seo, Yong-Jin
    • Journal of Satellite, Information and Communications
    • /
    • v.9 no.4
    • /
    • pp.63-68
    • /
    • 2014
  • Electrostatic Discharge(ESD) protection performance of PPS(PMOS pass structure) embedded N-type silicon controlled rectifier(NSCR_PPS) device with different partial p-well(PPW) structure was discussed for high voltage I/O applications. A conventional NSCR_PPS standard device shows typical SCR-like characteristics with low on-resistance, low snapback holding voltage and low thermal breakdown voltage, which may cause latch-up problem during normal operation. However, our proposed NSCR_PPS devices with modified PPW demonstrate the stable ESD protection performance with high latch-up immunity.

A Study on the Antecedent Variables of Relationship Structure Type (기업간 관계구조 관리유형의 선행변수에 관한 연구)

  • 김동진
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.22 no.52
    • /
    • pp.141-153
    • /
    • 1999
  • The focus of marketing study on the strategic tools has shifted from traditional 4Ps'(product, price, place and promotion) to macro relationship marketing which places emphasis on interfirm relationships. The purpose of this study is to develope antecedent variables of relationship type which play the most important role of interfirm relationships, and the antecedent variables of relationship structure comprises three factors : 1) transactional relationship structure, 2) hierarchical relationship structure and 3) embedded relationship structure.

  • PDF

Collision Analysis of EMU Carbody against Overhead Line Structure (전차선 지지 구조물에 대한 전동차 차체의 충돌 해석연구)

  • Kim, Jin-Seok;Koo, Jeong-Seo;Kwon, Seok-Jin
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.11-17
    • /
    • 2006
  • In this paper, crashworthiness of EMU carbody against overhead line structure is numerically evaluated. The material of the EMU carbody is made of stainless steel(SS301L). The material of the overhead line structure(a portal-type) is structure steel (SS400). The EMU carbody is numerically analyzed under collision conditions such as upright side-on impact scenario and angled impact scenario to collide against overhead line structure(a portal-type) at 64.6 kph, respectively.

  • PDF

A Study on the Natural Period Estimation for the Buildings of Upper Wall and Lower Frame Type (상부벽식-하부골조를 가진 복합구조물의고유주기 산정에 관한 연구)

  • 박기수
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1999.10a
    • /
    • pp.170-177
    • /
    • 1999
  • The natural period calculation equations specified in the current building code are empirical formulas that depend on height and material type of the structure. Building with the upper wall and lower frame type is a unique structure which composed of two different structural system This type of structure needs either the deep transfer girder or the thick transfer plate that brings the sudden change of stiffness and mass. Therefore the natural period equations recommended by the current code can not be applied directly. In this study the natural period of building with typical plan obtained by dynamci analysis is compared with that of various codes. Ad approximate estimation equation for the natural period of building with the upper wall and lower frame type obtained by regression analysis is recommended. by the current code can not be applied directly. In this study the natural period of building with typical plan obtained by dynamic analysis is compared with that of various codes, And approximate estimation equation for the natural period of building with the upper wall and lower frame type obtained by regression analysis is recommended.

  • PDF

Development of the Micro PM type Stepping Motor with Newly Structure (새로운 구조를 갖는 마이크로 PM형 스테핑 모터 개발)

  • Rhyu, Se-Hyun;Kwon, Byung-Il;Jung, In-Soung;Sung, Ha-Gyeong
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1261-1263
    • /
    • 2005
  • The micro permanent magnet(PM) type stewing motor preferred solution for many small electronics position determination devices since it is small in size. Thus, there are growing demands for PM type stepping motor that greater mechanical output, smaller size. But, the design of the it, having high performance and small size is very difficult because of its complex mechanical structure. This paper deals with a development of the newly structured micro PM type stepping motor with claw-poles. We introduced the small-sized PM type stepping motor that has new structure and analyzed the magnetic characteristic of it versus general type model using 3-D finite element analysis(FEA).

  • PDF

A Study on the Analysis of the Configuration and Properties of University Campus Cores through Space Syntax (공간구문론을 이용한 대학교 캠퍼스 코어의 공간구조 유형 및 특성 분석)

  • Lee, Dong-Joo;Ko, Eun-Hyung
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.16 no.6
    • /
    • pp.13-20
    • /
    • 2009
  • The purpose of this study is to analyze the configuration and properties of university campus cores for systematic approach and planning through space syntax based on master plans of 55 universities in Korea. The results of this study showed that: first, the campus cores were classified into 10 types through axial map analysis. They were '一 type', '二 type', 'ㄱ type', 'T type', '+ type', 'radiation type', 'grid type', 'polygon type', 'tree structure type' and 'combination type'.(table 7) The frequency of '一 type' was the highest by 27.2%, and 'radiation type' was the next by 14.5%; second, the integration value was 2.03(+ type), te90(grid type), te75(ㄱ type), te74(一 type), te67(二 type), te63(T type), te46(polygon type), te347(tree structure type) and te343(radiation type).(table 9) We could categorize the 'radiation type' and the 'tree structure type' as the first group, the 'polygon type' as the second group, the 'T type', the '二 type', the '一 type', and the 'ㄱ type' as the third group, the 'grid type' as the fourth group, the '+ type' as the fifth group; third, cases that the integration value of access road was very low(58.2%) was much more frequent than that of very high(32.7%); fourth, the most important space in the campus core were as follows: library and media center(18.1%), administration buildings and headquarters(15.7%), student center(15.7%), lecturing building(13.9%), streets and squares(13.3%).