An Experimental Study on Compressive Loading Capacity of PCT System (PCT System의 압축내하력에 관한 실험적 연구)

  • Han, Man-Yup;Kim, Jae-Hong;Kang, Sang-Hun;Jin, Kyung-Seok;Jeon, Yong-Sik;Cho, Byung-Ku
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.41-44
    • /
    • 2008
  • The PCT that supports the walls of long span temporary shoring facility is previously manufactured in the way of prestressing, and it which is composed of concrete is improved precast structure to satisfy enough stiffness. The components of PCT are manufactured as a fixed form, and they are close to the inner side of the wall of temporary shoring facility by fixed means in PCT. PCT system as support structure is that the ends of concrete filled segment members are united by the means of connection and also they have connection hole. In this study, PCT has enough bearing power for the long span temporary shoring facility, and also make the term of work reduce due to that the time of curing reduce through the method of precast.

  • PDF

A Study on the User-driven Urban Park Development Plan Awareness Survey - Focusing on Lawns·Grass Area - (의식조사를 통한 이용자 중심의 도시공원 조성방안 연구 - 잔디·녹지공간을 중심으로 -)

  • Seo, Jung-Young;Sung, Hyun-Chan
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.12 no.2
    • /
    • pp.61-72
    • /
    • 2009
  • This study aims to analyze the current situation of and issues in the structure of urban neighborhood parks and park facility installation in cities in Gyeonggi-do. Then, based on its findings, plans to improve the space structure of the parks were examined and suggested to raise the city environment improvement function and green area base function of urban parks and fully satisfy users' needs for pleasant rest, recreation and cultural activities. The findings showed that, within parks, the area of grass where access was restricted reached about 24.4% in average. In other words, only 75.6% of total park area could be freely used by park visitors. As for an improvement plan, the grass area where access is limited may be converted into a gras area that can be freely used to raise the park use area, which currently stands only at 75.6%, to 100%. The result of cross analysis through Chi-Square Test regarding lawn use as well as regarding (dis)agreement with reduction of lawn, based on the investigation of cognition, showed a significant agreement of park users with reduction of green areas. Therefore it is considered that lawn space must be reduced according the result of the analysis, to set up plans for facility space that would meet the desires of users. The analysis of user behaviors revealed that many of them used square spaces and walks; therefore it is considered that re-structuring of space is necessary according to local characteristics. This study also made some policy suggestion. urban parks must be a base of city green areas to counter climate changes. When developing a park creation plan, a user demand survey must be conducted in advance. In addition. grass construction methods should be improved to tolerate foot pressure.

Analysis between Computer Simulation and Real-car Crash Test of Energy Absorption Facilities for Various Road Environments (다양한 환경에 적용 가능한 충격흡수시설의 시뮬레이션 분석 및 실물충돌시험 결과 분석)

  • No, Min Hyung;Park, Jea Hong;Seo, Chang Won;Sung, Jung Gon;Yun, Duk Geun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.3
    • /
    • pp.399-407
    • /
    • 2022
  • Energy absorption facilities installed on roads should follow the performance standards of the real-car crash test of 'Installation and Maintenance Guidelines for Roadside Safety Facilities'. However, due to different installation conditions, such as differing structure widths on roads, some energy absorption facilities do not provide adequate performance. In order to apply varied environments on roads, an energy absorption structure was designed in this study with 150 mm height and four layers of W-shape guardrail at 200 mm intervals, and the performance was verified using LS-DYNA computer simulation. Through a real-car crash test, the performance of the facility designed by LS-DYNA was tested and was found to meet the performance of the CC2 category for crash cushions. The conclusion of the comparison demonstrates that the simulation and the real-car crash tests are both significant.

An Analysis on the Relationship of Architectural Features and Composition Elements for Structure Planning in School Gymnasium (학교체육관의 구조계획을 위한 구조시스템 구성요소의 변화와 건축특성의 영향분석)

  • Lee, Juna
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.26 no.5
    • /
    • pp.25-36
    • /
    • 2019
  • School gymnasium is a multi-purpose large space building for various events and physical education activities, and is a facility that requires an approach to the desirable structural design, besides mechanical problems of structure against loads. For the integrated structure design concerning the architectural features, the major considerations of gymnasium planning that are the internal and external shape of the gymnasium, the space scale with structure members, the structural efficiency by members weight reduction and openness of the gymnasium space will have to take into account in the structural planning. From this point of view, the several cases of the school gymnasium were investigated and the parametric analyses were performed to the models using the various structural system. The parameters were the composition elements of structure system that are profile of structure, rigidity of member, connection and anchorage and stability. At the result, It was presented that the profile of structure member was the most influential factor to structural efficiency and the effect of the form and space of gymnasium. Also the design informations of structure design having the various feature of form and space were presented for the initial gymnasium planning.

Application Standards for Substation Types and Facility Scales (변전소 형태 및 설비규모의 결정)

  • Min, Byeong-Wook;Shin, Myoung-Sik;Bahng, Seon-Woong;Kim, Young-Dal
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.438-439
    • /
    • 2011
  • Substations in Korea are classified into an outdoor steel structure type, an outdoor GIS(Gas Insulated Switchgear) type, an indoor GIS type, an underground GIS type, and a complex GIS type. Before 1970, substations were built in outdoor steel structure types only. In 1980, an 154kV indoor GIS type substation was built for the first time in Pusan. And the first 345kV indoor GIS type substation, the first 765kV full GIS substation were built in 1984 and in 2002 each. In 1998, 154kV indoor type substations were standardized into regular type and urban type which applied steel frames to structures. In 2002, this was re-standardized into five different types in detail. In 2007, hub substations which had high capacity were built in the region of industrial zone and heavy load areas. And 154kV compact substation was developed and standardized by compacting an indoor GIS type substation in 2009. This paper would present a series of substation type transition and application standards for substation types and facility scales.

  • PDF

A Study on the Development of the Healing Environment Evaluation Criteria for Elderly Care Hospital focusing on the Elderly Inpatient Characteristics (노인환자의 특성을 고려한 노인요양병원 치유환경 평가지표)

  • Chun, Sookyung;Nam, Kyung-Sook
    • Korean Institute of Interior Design Journal
    • /
    • v.26 no.4
    • /
    • pp.22-29
    • /
    • 2017
  • This paper investigates the evaluation criteria in order to manage healing environment of long-term care elderly hospital. Elderly hospital evaluation tool developed by Korean Government is used to assess elderly hospital facilities to check the hospital facility and maintain its quality. However, the evaluation indicators and questions mainly focusing on safety indicators. Some questions are too vague for precise evaluation. In this paper, we discuss the advantages and disadvantages of the present evaluation criteria to establish new assessment tool for precise evaluation. The literature research was conducted tp set up the new evaluation criteria. From this research, we developed an elderly focusing on healing environment checklist for elderly care hospital which contains 7 factors as the primary hierarchy structure (Safety, Accessibility, Amenity, Sensibility, Friendly to nature, Territory, Interaction) and 23 factors as the secondary hierarchy structure. This evaluation criteria will help healthcare facility designers and healthcare organizations to build the healthcare facilities.

A Study on the Static/Dynamic Stability for the Structure of a Mill Turret with a B-Axis Tilting Facility (B축 회전 기능을 갖춘 복합공구대 구조물의 정/동적 안정성에 관한 연구)

  • Kang, Seung-Hee;Kim, Chae-Sil
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.1
    • /
    • pp.39-44
    • /
    • 2014
  • Techniques of tool posts are developing such that variable machining is possible using only one machine for the complication of a product's shape and to reduce the machining time. In order to develop a mill turret with a variable machining function with the mounting of mill turret units on a B-axis tilting table, we determine the static/dynamic stability of the structure of the mill turret. To this end, a static structural analysis and a modal analysis were conducted. From the results of the static structural analysis, the maximum stress was found to be less than the allowable stress. By the comparing the results of the modal analysis of the excitation frequencies of the mill turret, there were no resonance regions found. Therefore, the mill turret with the B-axis tilting facility is shown to have good structural integrity.

Analysis of Microbial Community Structure in Biological Wastewater Treatment Process of Mixed Wastewater Treatment Facility using Environmental·Ecological Technique (환경·생태학적 기법을 이용한 혼합폐수 처리장의 생물학적 처리공정 내의 미생물 군집 특성 분석)

  • Son, Hyeng-Sik;Lee, Sang-Joon;Son, Hee-Jong
    • KSBB Journal
    • /
    • v.28 no.2
    • /
    • pp.80-85
    • /
    • 2013
  • The bacterial community structure in a biological reactor fed influent from a wastewater treatment system was investigated by denaturing gradient gel electrophoresis (DGGE) and in situ hybridization. Sludges were collected from three biological reactors (aerobic, oxic, and anoxic tanks) at the M wastewater treatment facility (WTF). The influent of the MWTF consisted of mixed tannery wastewater (40~65%) and seafood wastewater (35~60%). The treatment processes resulted in a removal efficiency for BOD (biochemical oxygen demand) and COD (chemical oxygen demand) of 83.6~98.2% and 72.8~84.6%, respectively for tannery wastewater than for seafood wastewater resulted in greater survival of biomass in the biological reactors and a higher removal of BOD, COD, and T-N of about 8~18%. In contrast, addition of greater amounts of seafood wastewater decreased the amount of biomass in the bioreactors due to the increasing concentration of chromium from that wastewater and it also. The dominant bacterial species during the high seafood wastewater input period were Burkholderia cepacia (JX901049) and an uncultured bacterium (JF247555), while Pseudomonas geniculata (HQ256559) was dominant during the high tannery wastewater input period. Flavobacteriumsp. BF.107 (FM173271) and Hyphomicrobium zavarzinii (Y14306) were dominant under anoxic conditions.

Failure Evaluation Plan of a Reactor Internal Components of a Decommissioned Plant

  • Hwang, Seong Sik;Kim, Sung Woo;Choi, Min Jae;Cho, Sung Hwan;Kim, Dong Jin
    • Corrosion Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.189-195
    • /
    • 2021
  • A technology for designing and licensing a dedicated radiation shielding facility needs to be developed for safe and efficient operation an R&D center. Technology development is important for smooth operation of such facilities. Causes of damage to internal structures (such as baffle former bolt (BFB) of pressurized water reactor) of a nuclear power reactor should be analyzed along with prevention and countermeasures for similar cases of other plants. It is important to develop technologies that can comprehensively analyze various characteristics of internal structures of long term operated reactors. In high-temperature, high-pressure operating environment of nuclear power plants, cases of BFB cracks caused by irradiated assisted stress corrosion cracks (IASCC) have been reported overseas. The integrity of a reactor's internal structure has emerged as an important issue. Identifying the cause of the defect is requested by the Korean regulatory agency. It is also important to secure a foundation for testing technology to demonstrate the operating environment for medium-level irradiated testing materials. The demonstration testing facility can be used for research on material utilization of the plant, which might have highest fluence on the internal structure of a reactor globally.

Case Study for Energy Conservation Measures of Hospital Buildings Using the Analysis of Energy Consumption Structure (의료시설 에너지절약 운영방법 도출을 위한 사례분석을 통한 에너지 영향요소 분석)

  • Lee, Sangmoon;Cho, Jinkyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.2
    • /
    • pp.57-69
    • /
    • 2019
  • Because the hospital building operates 24 hours a day, 365 days a year for treatment and restoration of patients, it has a different pattern of energy use than that of ordinary buildings. Hospitals contribute to energy consumption and have a negative environmental impact. This study aims to find how meaningful energy performance, reflecting good energy management and ECMs, can be operated for hospital buildings, a category encompassing complex buildings with different systems and large differences between them. In this study, we proposed the energy diagnosis & evaluation method and energy management process to verify energy saving through operation data based on system & facility characteristics, operation pattern and energy consumption characteristics of hospital building. Energy consumption structures were surveyed throughout 4 reference hospital in Seoul, Korea. Findings confirm that different hospital departments have hugely different energy-demand profiles. Energy efficiency and energy saving potentials are presented. The energy performance analysis can be applied to a wide range of problems in energy-system operation.