• 제목/요약/키워드: structure effect

검색결과 13,147건 처리시간 0.037초

지반-구조물 상호작용 효과를 고려한 지진격리시스템이 적용된 원전 격납건물의 지진 취약도 평가 (Seismic Fragility Evaluation of Isolated NPP Containment Structure Considering Soil-Structure Interaction Effect)

  • 임승현;정형조;김민규;최인길
    • 한국지진공학회논문집
    • /
    • 제17권2호
    • /
    • pp.53-59
    • /
    • 2013
  • Several researches have been studied to enhance the seismic performance of nuclear power plants (NPPs) by application of seismic isolation. If a seismic base isolation system is applied to NPPs, seismic performance of nuclear power plants should be reevaluated considering the soil-structure interaction effect. The seismic fragility analysis method has been used as a quantitative seismic safety evaluation method for the NPP structures and equipment. In this study, the seismic performance of an isolated NPP is evaluated by seismic fragility curves considering the soil-structure interaction effect. The designed seismic isolation is introduced to a containment building of Shin-Kori NPP which is KSNP (Korean Standard Nuclear Power Plant), to improve its seismic performance. The seismic analysis is performed considering the soil-structure interaction effect by using the linearized model of seismic isolation with SASSI (System for Analysis of Soil-Structure Interaction) program. Finally, the seismic fragility is evaluated based on soil-isolation-structure interaction analysis results.

LMDI 방법론을 이용한 국내 제조업의 온실가스 배출 요인분해분석 (LMDI Decomposition Analysis for GHG Emissions of Korea's Manufacturing Industry)

  • 김수이;정경화
    • 자원ㆍ환경경제연구
    • /
    • 제20권2호
    • /
    • pp.229-254
    • /
    • 2011
  • 본 논문은 LMDI(Log Mean Divisia Index) 방법론을 이용하여 국내 제조업의 온실가스 배출에 대한 요인분해분석을 하였다. 국내 제조업의 온실가스 배출에 대한 요인분해는 크게 생산효과, 구조효과, 집약도효과, 에너지믹스효과, 배출계수효과 등 다섯 가지 요인으로 분해하였다. 1991년~2007년까지 국내 제조업의 온실가스 배출변화 요인을 분석한 결과를 보면 국내 제조업의 온실가스 배출은 대부분 생산효과에 의해서 증가하였다. 구조효과와 집약도는 온실가스 배출을 줄이는 역할을 하였으며, 구조효과보다는 집약도효과가 더 많이 온실가스 배출을 감소시키는 방향으로 작용하였다. 그리고 에너지믹스효과와 배출계수효과는 다른 효과들에 비해서 그 비중이 작지만 온실가스 배출 증감에 영향을 미치고 있다. 에너지믹스효과는 온실가스 배출 증가 요인으로 배출계수효과는 감소요인으로 작용하였다. 한편 시계열로 에너지 소비를 요인분해 해 본 결과 1998년 IMF 체제를 전후로 온실가스 패턴에 변화가 일어났다. IMF 체제 이후로 구조효과와 집약도효과에 의한 온실가스 감축이 IMF 체제 이전보다 더욱 두드러진 것이 특징이다. 2001년 이후 진행된 신고유가 시대를 맞이해서는 구조효과와 집약도효과가 더욱 촉진되었다.

  • PDF

An integrated optimal design of energy dissipation structures under wind loads considering SSI effect

  • Zhao, Xuefei;Jiang, Han;Wang, Shuguang
    • Wind and Structures
    • /
    • 제29권2호
    • /
    • pp.99-110
    • /
    • 2019
  • This paper provides a simple numerical method to determine the optimal parameters of tuned mass damper (TMD) and viscoelastic dampers (VEDs) in frame structure for wind vibration control considering the soil-structure interation (SSI) effect in frequency domain. Firstly, the numerical model of frame structure equipped with TMD and VEDs considering SSI effect is established in frequency domain. Then, the genetic algorithm (GA) is applied to obtain the optimal parameters of VEDs and TMD. The optimization process is demonstrated by a 20-storey frame structure supported by pile group for different soil conditions. Two wind resistant systems are considered in the analysis, the Structure-TMD system and the Structure-TMD-VEDs system. The example proves that this method can quickly determine the optimal parameters of energy dissipation devices compared with the traditional finite element method, thus is practically valuable.

Seismic response of foundation-mat structure subjected to local uplift

  • El Abbas, Nadia;Khamlichi, Abdellatif;Bezzazi, Mohammed
    • Coupled systems mechanics
    • /
    • 제5권4호
    • /
    • pp.285-304
    • /
    • 2016
  • The effects of large rotations and p-delta on the dynamic response of a structure subjected to seismic loading and local uplift of its foundation were analyzed in this work. The structure was modeled by an equivalent flexible mat mounted on a rigid foundation that is supported either by a Winkler soil type or a rigid soil. The equations of motion of the system were derived by taking into account the equilibrium of the coupled foundation-mat system where the structure was idealized as a single-degree-of-freedom. The obtained nonlinear coupled system of ordinary differential equations was integrated by using an adequate numerical scheme. A parametric study was performed then in order to evaluate the maximum response of the system as function of the intensity of the earthquake, the slenderness of the structure, the ratio of the mass of the foundation to the mass of the structure. Three cases were considered: (i) local uplift of foundation under large rotation with the p-delta effect, (ii) local uplift of foundation under large rotation without including the p-delta effect, (iii) local uplift of foundation under small rotation. It was found that, in the considered ranges of parameters and for moderate earthquakes, assuming small rotation of foundation under seismic loading can yield more adverse structural response, while the p-delta effect has almost no effect.

부가질량 효과와 호흡모드를 고려한 구조-유체연성진동해석 (The Effect of Added Mass of Water and Breath Mode in Fluid-Structure Coupled Vibration Analysis)

  • 배성용
    • 동력기계공학회지
    • /
    • 제9권4호
    • /
    • pp.71-76
    • /
    • 2005
  • Marine structures are often in contact with inner or outer fluid as stern, ballast and oil tanks. The effect of interaction between fluid and structure has to be taken into consideration when we estimate the dynamic response of the structure appropriately. Fatigue damages can also be sometimes observed in these tanks which seem to be caused by resonance. Thin walled tank structures in ships which are in contact with water and located near engine or propeller where vibration characteristics are strongly affected by the added mass of containing water. Therefore it is essentially important to estimate the added mass effect to predict vibration characteristics of tank structures. But it is difficult to estimate exactly the magnitude of the added mass because this is a fluid-structure interaction problem and is affected by the free surface, vibration modes of structural panels and the depth of water. I have developed a numerical tool of vibration analysis of 3-dimensional tank structure using finite elements for plates and boundary elements for fluid region. In the present study, the effect of added mass of containing water, the effect of structural constraint between panels on the vibration characteristics are investigated numerically and discussed. Especially a natural frequencies by the fluid interaction between 2 panels and a breath mode of the water tank are focused on.

  • PDF

Kink-effect 개선을 위한 세 개의 분리된 N+ 구조를 지닌 대칭형 듀얼 게이트 단결정 TFT 구조에 대한 연구 (Single-silicon TFT Structure for Kink-effect Suppression with Symmetric Dual-gate by Three Split floating N+ Zones)

  • 이대연;황상준;박상원;성만영
    • 한국전기전자재료학회논문지
    • /
    • 제18권5호
    • /
    • pp.423-430
    • /
    • 2005
  • In this paper, we have simulated a Symmetric Dual-gate Single-Si TFT which has three split floating $n^{+}$ zones. This structure reduces the kink-effect drastically and improves the on-current. Due to the separated floating $n^{+}$ zones, the transistor channel region is split into four zones with different lengths defined by a floating $n^{+}$ region. This structure allows an effective reduction of the kink-effect depending on the length of two sub-channels. The on-current of the proposed dual-gate structure is 0.9 mA while that of the conventional dual-gate structure is 0.5 mA at a 12 V drain voltage and a 7 V gate voltage. This results show a $80 {\%}$ enhancement in on-current by adding two floating $n^{+}$ zones. Moreover we observed the reduction of electric field In the channel region compared to conventional single-gate TFT and the reduction of the output conductance in the saturation region. In addition we also confirmed the reduction of hole concentration in the channel region so that the kink-effect reduces effectively.

브러시리스 직류전동기 특성에 대한 영구자석 오버행 효과 (Permanent Magnet Overhang Effect on the Characteristics in Brushless DC Motor)

  • 전연도;약미진치;이주
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권4호
    • /
    • pp.229-236
    • /
    • 2004
  • In this paper, the effect of permanent magnet overhang structure on the characteristics in Brushless DC motor has analyzed quantitatively. We classified the overhang structure as symmetric and asymmetric. 3D equivalent magnetic circuit network (EMCN) method which uses the permeance as the distributive variable is used for the efficient analysis of magnetic field. The overhang effect which increases the linkage flux at the stator is verified by comparison between overhang and no overhang structure. In addition, it is known that no load back electro motive force (EMF) is also increased due to the overhang effect. In case of asymmetric overhang structure, the ratio effect of the upper to lower overhang length on the magnetic forces is analyzed. Form the analysis results, the variation of the asymmetric overhang ratio has a significant effect on the axial magnetic force except the radial and tangential magnetic forces. The validity of the analysis results is also clarified by comparison between calculated results and measured ones such as back EMF and cogging torque.

e-Learning에서 영어식 사고구조, 사전 영어능력, 영어자기효능감의 몰입을 통한 학습효과 (A Study of the Relations among English Thinking Structure, Pre-English Skill, Self-Efficacy in English, Flow and Learning Effect)

  • 강정화
    • 디지털융복합연구
    • /
    • 제8권4호
    • /
    • pp.165-176
    • /
    • 2010
  • 본 연구는 영어학습이 이루어지는 e-Learning 환경에서 학습효과에 영향을 미치는 요인들과 몰입경험 간의 관계를 알아보는데 그 목적이 있다. 이를 위하여 영어식사고구조, 사전영어능력, 영어자기효능감 그리고 몰입을 학습효과에 영향을 미치는 독립변수로 설정했으며, 연구의 결과는 다음과 같다. 첫째, 영어식사고구조, 사전영어능력, 영어자기효능감, 몰입, 학습효과 간의 각각의 관제는 통계적으로 정적인 상관관계가 있다. 둘째, 영어식사고구조, 사전영어능력, 영어자기효능감 모두 몰입을 예측하였으며, 몰입경험이 또한 학습효과를 예측한다. 셋째, 영어자기효능갑과 학습효과 간의 관계에서 몰입 경험이 매개역할을 하는 것으로 나타났다.

  • PDF

The effects of temperature and vacancy defect on the severity of the SLGS becoming anisotropic

  • Tahouneh, Vahid;Naei, Mohammad Hasan;Mashhadi, Mahmoud Mosavi
    • Steel and Composite Structures
    • /
    • 제29권5호
    • /
    • pp.647-657
    • /
    • 2018
  • Geometric imperfections may be created during the production process or setting borders of single-layer graphene sheets (SLGSs). Vacancy defects are an instance of geometric imperfection, so investigating the effect of these vacancies on the mechanical properties of single-layer graphene is extremely important. Since very few studies have been conducted on the structure of imperfect graphene (with the vacancy defect) as an anisotropic structure, further study of this defective structure seems imperative. Due to the vacancy defects and for the proper assessment of mechanical properties, the graphene structure should be considered anisotropic in certain states. The present study investigates the effects of site and size of vacancy defects on the mechanical properties of graphene as an anisotropic structure using the lekhnitskii interaction coefficients and Molecular Dynamic approach. The effect of temperature on the severity of the SLGS becoming anisotropic is also investigated in this study. The results reveal that the amount of temperature has a big effect on the severity of the structure getting anisotropic even for a graphene without any defects. The effect of aspect ratio, temperature and also size and site of vacancy defects on the material properties of the graphene are studied in this research work. According to the present study, using material properties of flawless graphene for imperfect structure can lead to inaccurate results.

Numerical investigations of structure-soil-structure interaction on footing forces due to adjacent building

  • Shrish Chandrawanshi;Vivek Garg
    • Earthquakes and Structures
    • /
    • 제26권6호
    • /
    • pp.477-487
    • /
    • 2024
  • The interaction between multiple structures through the supporting soil media, known as structure-soil-structure interaction (SSSI), has become an increasingly important issue due to rapid urbanization. There is a need to investigate the effect of SSSI on the structural response of buildings compared to non-interaction analysis (NIA) and soil-structure interaction (SSI) analysis. In the present study, two identical 4-bay×4-bay, three-story RCC buildings are modeled adjacent to each other with a soil domain beneath it to investigate the effect of SSSI on the forces experienced by footings under gravity and seismic load cases. The ANSYS software is used for modeling various non-interaction and interaction models which work on the principle of FEM. The results indicate that in most of the footings, the SSSI effect causes a significant redistribution of forces compared to SSI and NIA under both gravity and seismic load cases. The maximum interaction effect is observed on the footings that are closer to the adjacent building. The axial force, shear force and bending moment values on these footings show that SSI causes a significant increase in these values compared to non-interaction analysis but the presence of adjacent building relieves these forces significantly.