• Title/Summary/Keyword: structure crack

Search Result 1,242, Processing Time 0.024 seconds

Analysis of Heat of Hydration and Thermal Stresses in Mass Concrete (매스 콘크리트의 수화열과 온도 응력 해석)

  • 박영진;김진근;전상은;방기성
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.281-286
    • /
    • 1999
  • Nonlinear temperature distribution induced by the hydration heat generates thermal stress in mass concrete. At early ages, such thermal stress may induce thermal cracks in the structure which can affect on the durability and safety of the structure. Up to now, a lot of works have focused on the prediction of temperature distribution and thermal stress in the structure. In most of such works, however, the inside of structure was considered as adiabatic state to predict temperature distribution and the thermal stress. And due to the lacks of appropriate analysis models after crack, there was little research on the crack occurrence. This paper deals with the prediction of the temperature distribution in the structure using the rate of hydration heat generation and also estimates the behavior of structure before and after cracking due to hydration heat using crack band model.

  • PDF

A Study of Preventing Chevron Crack in Cold Extrusion (냉간 압출시 Chevron Crack 방지에 대한 고찰)

  • 최영순;이정환
    • Transactions of Materials Processing
    • /
    • v.6 no.3
    • /
    • pp.221-226
    • /
    • 1997
  • Chevron crack in cold extrusion has been studied in view of deformation conditions and material characteristics. There is V formed chevron crack is occasionally occurred in core part of shaft by multistage free extrusion. Although many research results were reported and theoretical analyses were accompanied, in this study we discussed practical method to prevent chevron crack in the field of working conditions and material characteristics. We have found that chevron crack is eliminated under condition of high hydrostatic state in deformation and decreased segregation, refinement of micro structure of materials.

  • PDF

Creep-Fatigue Crack Growth Behavior of a Structure with Crack Like Defects at the Welds

  • Lee, Hyeong-Yeon;Kim, Seok-Hoon;Lee, Jae-Han;Kim, Byung-Ho
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.12
    • /
    • pp.2136-2146
    • /
    • 2006
  • A study on a creep-fatigue crack growth behavior has been carried out for a cylindrical structure with weldments by using a structural test and an evaluation according to the assessment procedures. The creep-fatigue crack growth behavior following the creep-fatigue crack initiation has been assessed by using the French A16 procedure and the conservatism for the present structural test has been examined. The structural specimen is a welded cylindrical shell made of 316 L stainless steel (SS) for one half of the cylinder and 304 SS for the other half. In the creep-fatigue test, the hold time under a tensile load which produces the primary nominal stress of 45 MPa was one hour at $600^{\circ}C$ and creep-fatigue loads of 600 cycles were applied. The evaluation results for the creep-fatigue crack propagation were compared with those of the observed images from the structural test. The assessment results for the creep-fatigue crack behavior according to the French Al6 procedure showed that the Al6 is overly conservative for the creep-fatigue crack propagation in the present case with a short hold time of one hour.

Mechanical Characteristics and Fatigue Crack Propagation of Super Duplex Stainless Steel by Distribution of Austenite (오스테나이트 분포에 따른 수퍼 2상 스테인리스강의 기계적 특성과 피로균열 진전거동)

  • Do, J.Y.;Lee, S.K.;Ahn, S.H.;Nam, K.W.;Kang, C.Y.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.14 no.4
    • /
    • pp.205-211
    • /
    • 2001
  • The characteristics of super duplex stainless steel were investigated on its fibrous structure and dispersed structure. These structures consist of various volume fractions and distributions of the austenite phase that were obtained by changing the heat treatment temperature and cycle. The fibrous structure had higher austenite volume fraction than dispersed structure on the same temperature. As the austenite volume fraction increased in both structures, tensile strength and elongation increased, but hardness decreased. Fatigue life of fibrous structure parallel to rolling direction was shorter than that of perpendicular to rolling direction. Fatigue life of dispersed structure was longer than parallel fibrous structure, and shorter than perpendicular fibrous structure. Fatigue crack propagation rate of fibrous structure was faster than that of dispersed structure.

  • PDF

Characteristics of AE Signals of Matrix Cracks in Composites Due to the Different Specimen Shapes (시편 형상에 따른 복합재료의 모재균열 신호특성)

  • 방형준;박상욱;김천곤;홍창선
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2002.05a
    • /
    • pp.39-43
    • /
    • 2002
  • As the concept of the smart structure, monitoring of acoustic emission (AE) can be applied to inspect the fracture of the entire structure in operating condition using built-in sensors. The objective of this study is to find the characteristics of matrix crack signals in composites due to the different specimen shapes. To detect matrix crack signals, we performed tensile tests by changing the thickness, width and length of the specimen. For the quantitative evaluation, time frequency analysis such as short-time Fourier transform (STFT) was used to characterize the matrix crack signals from PZT sensor. The experimental result shows the distinctive signal features in frequency domain due to the different specimen shapes.

  • PDF

A study on the fatigue performance of repaired concrete structure. (콘크리트 균열보수부의 내피로성능에 관한 연구)

  • Kwon Yong Joo;Kang Dong Soo;Kim Kyu Yong;Park Sung Woo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.535-538
    • /
    • 2005
  • The problem of the crack which occures from the reinforced concrete structure. could be caused by the complexed factors. When the crack happen, it caused fatal blemish to manage and maintain the structure such as structural problem, licking, spalling, viewing Even though they study and work hard to solve this kind of problem in the world, there are no countermeasure for perfect prevention of crack. After the crack checked out, a method of repair-reinforcement has been sutdied and operated actively. In this experiment, studied durability of repair material. Experiment wave and durability of epoxy and urethane's were shown good result, and micro cement's durability displayed result that is not good. Result of a repeat tired experiment displayed result that micro cement is bad.

  • PDF

Contact Damage and Fracture of Poreclain/Glass-Infiltrated Alumina Layer Structure for Dental Application (치아 응용을 위한 /유리침윤 알루미나 이중 층상구조의 접촉손상 및 파괴)

  • 정연길;여정구;최성설
    • Journal of the Korean Ceramic Society
    • /
    • v.35 no.12
    • /
    • pp.1257-1265
    • /
    • 1998
  • Hertzian contact tests were used to investigate the evolution of fracturedamage in the coating layer as functions of contact load and coating thickness by studying crack patterns in porcelain on glass-infiltrated alumina bilayer system conceived to simulate the crown structure of a tooth. Cone cracks initiated at the coating top surface without delamination at interface and crack propagation to substrate. Preferentially the cracks made multi-cracks at the coating top surface rather than proceeding to interface. The cracks were highly stabilized with wide ranges between the loads to initiate first cracking and to cause final failure im-plying damage-tolerant capability. Finite element modelling was used to evaluate the stress distribution. Maximum tensile stress were responsible for the cracking at the coating layer and had a profound influence on the crack pattern and fracture damage in the layered structure materials.

  • PDF

A Study on Parameters Affected the Fatigue Crack Growth in Steel Structure Members( II ) -The Effect of Surface Residual Stress for Crack Closure- (강구조 부재의 피로균열성장에 미치는 제인자에 관한 연구( II ) -표면잔류응력이 균열닫힘에 미치는 영향-)

  • Choi, Young Jae;Kyung, Kab Soo
    • Journal of Korean Society of Steel Construction
    • /
    • v.8 no.3 s.28
    • /
    • pp.3-11
    • /
    • 1996
  • To investigate the effect of fatigue crack growth due to the surface residual stress, it is measured the residual stress distribution by x-ray diffraction at the crack tip each constant crack growth in the notch specimens, and quantitively assessed the effect of crack closure caused to the distribution of compressive stress at the crack tip from evaluating crack openning stress using the finite element analysis. It is concluded that the degree of the residual stress distribution at the crack tip is decreased with increasing the crack length. From the fact that it is similar to the crack openning stress ratio, it is found that the compressive residual stress distribution and size is related to the crack closure effect and surface residual stress field with propagating crack in the notch specimens depends on the stress intensity factor range at the crack tip.

  • PDF

A Study on the Threshold Condition of Crack Propagation for Pre-Crack and Micro-Hole Specimens (프리크랙과 微小圓孔材의 크랙成長 下限界條件에 관한 硏究)

  • 송삼홍;윤명진
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.2
    • /
    • pp.278-285
    • /
    • 1988
  • The Critical size of artificially induced micro-holes in 0.17%, 0.36% Carbon steel Specimens with Spheroidized Cementite and in 0.17% carbon steel specimens with martensite structure is compared with annealed pre-crack in order to discuss the physical meaning of the fatigue limit and evaluation of the tolerant micro flaw size at the stress level of the fatigue limit. Results obtained were summarized as follows; (1) In this study, non-propagating crack length of Smooth specimen and critical pre-crack length (lc) is coincide. (2) In the carbon steels with spheroidized cementite structure, critical pre-crack length (lc) and allowable micro-hole size (dc) is coincide each other at the fatigue limit level. (3) It has been published that there exists a particular size of micro-hole which has no effect on the fatigue limit. In this study, the micro-hole of critical size can be regarded as equivalent to a tolerant micro flaw which would not reduce the fatigue limit.

Comparison of Stress Intensity Factors for Cylindrical Structure with Circumferential Through-Wall Cracks subjected to Tensile Load (원주방향 관통균열이 존재하는 원통형 구조물의 인장하중에 의한 응력확대계수 비교)

  • Dal Woo Jung;Chang Kyun Oh;Hyun Su Kim;Hyeong Do Kweon;Jun Seok Yang
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.17 no.2
    • /
    • pp.101-108
    • /
    • 2021
  • To date, a number of stress intensity factor (SIF) solutions have been proposed for the cylindrical structure with circumferential through-wall cracks. However, each solution has a different format as well as applicable range. It is also known that there is a significant difference in predicted SIF values depending on the shape of the structure and the size of the crack. In this study, the applicability of various SIF solutions was analyzed by comparing the finite element analysis results for the case where a tensile load is applied to the cylindrical structure with circumferential through-wall crack. It is found that the calculated SIF gradually decreases and converges to a certain value with increasing length-to-radius ratio. Therefore, an appropriate length-to-radius ratio should be set in consideration of the dimensions of the actual cylindrical structure. For piping with sufficiently long cylinder, the ASME solution is found to be the most appropriate, and for a short cylinder, the API solution should be applied. On the other hand, the WEC solution requires careful attention to its application.