• Title/Summary/Keyword: structural strength evaluation

Search Result 1,130, Processing Time 0.046 seconds

Hull Strength Evaluation of Dissemination 12ft Bass Fishing Boat Using FEA (보급형 12피트 배스 낚시보트의 유한요소해석을 통한 선체강도평가)

  • Oh, Young-Cheol;Ko, Jae-Yong;Chung, Se-Yun;Choi, Jeong-Hwan;Kim, Hyeon-Jin
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2012.06a
    • /
    • pp.225-226
    • /
    • 2012
  • Recently, In the domestic is used mainly fiberglass reinforced plastic(GRP) and is built for maritime leisure vessel & structures. but it less attention is insufficient for ship of structural strength assessment of maritime leisure vessel. Therefore, The structural strength evaluation suitable for the domestic situation formulate and is applied to domestic regulations of "Guidance for Recreational Crafts" of Korea register of shipping(KR) & "Reinforced plastic line structure standards" of Ministry of Land, Transport and Maritime Affairs. the structural design and finite element analysis(FEA) to ensure the reliability.

  • PDF

STRUCTURAL SAFTY EVALUATION OF COMPRESSOR DRIVING MOTOR SHAFT SYSTEM (컴프레서 구동용 전동기 축계의 구조 안전성 평가)

  • Jung, Kun-Hwa;Kwak, Ju-Ho;Kim, Byung-Joo;Lee, Jong-Moon
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1031-1036
    • /
    • 2007
  • Torsional vibration analysis is necessary at design stage to ensure the reliability of a system particularly when the driven machine is a reciprocating compressor. This paper contains the results of torsional vibration analysis and fatigue strength evaluation for 540 kW compressor driving motor. Torsional vibration analysis showed that the $2^{nd}$ torsional mode of the entire shaft system has the possibility of resonance with the $14^{th}$ order excitation of compressor and twin line frequency of motor at operating speed. Therefore, the analyses were required to ensure the structural reliability of the motor. The fatigue strength was evaluated for the shaft and inner fans using the results of forced vibration analysis. It is concluded that the motor has sufficient fatigue strength under normal operating condition.

  • PDF

Evaluation of structural behavior of RC columns strengthened with high-strength steel bars (고강도 횡보강철근을 사용한 철근 콘크리트 기둥의 구조 거동 평가)

  • Lee, Jang-Hee;Kim, Do-Jin;Baek, Seung-Cheol;Kim, Sang-Woo;Kim, Kil-Hee;Lee, Jung-Yoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.103-104
    • /
    • 2010
  • There are two conflicting opinions about effect of confinement using High-Strength transverse reinforcement. This paper verifies evaluation of structural behavior of RC columns strengthened with high-strength steel bars by performing an experimental study of 15 large-scale column confined by high-strength transverse reinforcement tests.

  • PDF

Evaluation of Static Structural Integrity for Composites Wing Structure by Acoustic Emission Technique (음향방출법을 응용한 복합재 날개 구조물의 정적구조 건전성 평가)

  • Jun, Joon-Tak;Lee, Young-Shin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.8
    • /
    • pp.780-788
    • /
    • 2009
  • AE technique was applied to the static structural test of the composite wing structure to evaluate the structural integrity and damage. During the test, strain and displacements measurement technique were used to figure out for static structural strength. AE parameter analysis and source location technique were used to evaluate the internal damage and find out damage source location. Design limit load test, the 1st and 2nd design ultimate load tests and fracture test were performed. Main AE source was detected by an sensor attached on skin near by front lug. Especially, at the 1st design ultimate test, strain and displacements results didn't show internal damage but AE signal presented a phenomenon that the internal damage was formed. At the fracture test, AE activities were very lively, and strain and displacements results showed a tendency that the load path was changed by severe damage. The internal damage initiation load and location were accurately evaluated during the static structural test using AE technique. It is certified from this paper that AE technique is useful technique for evaluation of internal damage at static structural strength test.

A Study on the Reinforced Method of Doubler Plate in Ship Hull Structure (선박 이중판의 보강법 연구)

  • HAM JUH-HYEOK
    • Journal of Ocean Engineering and Technology
    • /
    • v.17 no.5 s.54
    • /
    • pp.39-47
    • /
    • 2003
  • A study of the structural strength evaluation on the doubler plate, considering various load cases that were subjected to in-plane and out of plane combined load, has been performed through the systematic evaluation process. In order to estimate the proper static strength of doubler plate for various load cases, elasto-plastic large deflection analysis is introduced, including the contact effect between main plate and doubler. The characteristics of stiffness and strength variation are discussed, based on the results. In order to compare the doubler structure with the original strength of main plate, without doubler, simple formulas for the evaluation of the equivalent flat plate thickness are derived for each load case, respectively, based on the additional series of analysis of flat plate structure. Using these derived equations, the thickness change of an equivalent flat plate is analyzed according to the variation of various design parameters of doubler platesome design guides are suggested in order to maintain the original strength of main plate without doubler reinforcement. Finally, correlation between derived equivalent flat plate formula and the developed buckling strength formulas are discovered, and these relations are formulated for the future development of simple strength evaluation formula of general doubler plate structure.

Structural Performance Evaluation of System Scaffolding for Elevator Installation Work (엘리베이터 설치 작업용 시스템 비계의 구조 성능 평가)

  • Jong Moon Hwang;Gi Yeol Lee
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.3
    • /
    • pp.61-68
    • /
    • 2023
  • This study performed a structural performance evaluation of a system scaffolding for elevator installation work developed in previous studies. The structural performance was evaluated via a structural test conducted to apply the working load specified in the design standard. The deflection of the horizontal member and the stress of each member constituting the system scaffolding were measured. Consequently, the structural safety evaluation including structural behavior and required performance was performed using the deflection and stresses measured from the structural test. The structural test and safety evaluation results based on the heavy working load corresponding to the design load indicated that the deflection, which is the performance criterion of the horizontal member, did not exceed the allowable value. Further, each member's stress, which is a safety evaluation indicator, did not exceed the allowable strength for both horizontal and vertical members with bending behavior and fordable bracing with tensile behavior, while also satisfying the required safety factor. In addition, the results confirmed the safety against deformation, partial damage, and destruction owing to excessive and maximum load. Therefore, the system scaffolding developed in this study satisfies both the structural performance and safety required by the design standards; thus, it can be applied to elevator installation work sites.

An Experimental Study on the Estimation Technique of Mortar Early Strength by Microwave (마이크로파에 의한 모르터의 조기강조 추정기법에 관한 실험적 연구)

  • 원준연;백민수;이종균;안형준;정상진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.15-218
    • /
    • 1999
  • Concrete is the most generous, universal main structural material. There is active study for processing quality, stable quality mangement. Especially, strength is basic factor of evaluating stability of concrete building. Regaining required strength and homogeneity is very important to get self-stability in building to evaluate another characteristic. Concrete strength is important to the quality management. But, result of hardened concrete's quality test is hardly reflected to works immediately. When required strength is not enough, it could bring out safe problem, economic and administrative cost. It is pointed out that problems from strength evaluation, so early evaluation of concrete quality is required. From the trend that accelerating high quality concrete development, improving the method of quality test and early evaluation measure is urgent project. Throughout this report, it is suggested the method with use of microwave to evaluate 28-days concrete strength.

  • PDF

A Study on Evaluation Techniques of Characteristic Strength of Concrete in Existing Structures (실존 콘크리트 구조물의 특성강도 추정기법에 관한 연구)

  • 권영웅;정성철;이상윤;김민수;김인식;이지은
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.04b
    • /
    • pp.703-706
    • /
    • 1998
  • Primarily, to evaluate the structural condition assessment of concrete structures, percentile strength of concrete in concrete structures should be found out. This study aims to establish the evaluation techniques for concrete strength in existing concrete structures considering the concrete quality and reliability. The results are as follows ; 1. Percentile strength of concrete in concrete structures can be estimated from following strength equation. $$f_p=f_{mea} - {\lambda}_pS_s$$2. For the calibration of above percentile strength equation with proposed codes or specifications, following sample size based on ASTM E122 can be applied.

  • PDF

Evaluation Method of Bonded Strength Considering Stress Singularity in Adhesively Bonded Joints (응력특이성을 고려한 접착이음의 강도평가 방법)

  • 정남용
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.7 no.1
    • /
    • pp.58-68
    • /
    • 1998
  • Advantages of adhesively bonded joints and techniques of weight reduction have led to increasing use of structural adhesives such as LSI(large scale integration) package, automobile, aircraft in the various industries. In spite of such wide applications of adhesively bonded joints, the evaluation method of bonding strength has not been established. Stress singularity occurs at the interface edges of adhesively bonded joints and it is required to analyze it. In this paper, the stress singularity using 2-dimensional elastic boundary element method (BEM) with the changes of the lap length and adhesive for single lap joint was analyzed, and experiments of strength evaluation were carried out. As the results, the evaluating method of bonding strength considering stress singularity at interface edges of adhesively bonded joints and stress intensity factor of interface crack have been proposed in static and fatigue test.

  • PDF