• 제목/요약/키워드: structural performance test

검색결과 2,146건 처리시간 0.031초

Structural damage detection using a multi-stage improved differential evolution algorithm (Numerical and experimental)

  • Seyedpoor, Seyed Mohammad;Norouzi, Eshagh;Ghasemi, Sara
    • Smart Structures and Systems
    • /
    • 제21권2호
    • /
    • pp.235-248
    • /
    • 2018
  • An efficient method utilizing the multi-stage improved differential evolution algorithm (MSIDEA) as an optimization solver is presented here to detect the multiple-damage of structural systems. Natural frequency changes of a structure are considered as a criterion for damage occurrence. The structural damage detection problem is first transmuted into a standard optimization problem dealing with continuous variables, and then the MSIDEA is utilized to solve the optimization problem for finding the site and severity of structural damage. In order to assess the performance of the proposed method for damage identification, an experimental study and two numerical examples with considering measurement noise are considered. All the results demonstrate the effectiveness of the proposed method for accurately determining the site and severity of multiple-damage. Also, the performance of the MSIDEA for damage detection compared to the standard differential evolution algorithm (DEA) is confirmed by test examples.

가변용량형 사판식 피스톤 펌프의 구조해석 및 성능시험 (Structural Analysis and Performance Test of Variable Displacement Swash Plate Piston Pumps)

  • 이정실;전차수
    • 한국기계가공학회지
    • /
    • 제21권7호
    • /
    • pp.105-113
    • /
    • 2022
  • In this study, a variable displacement swash plate pump supplying high-pressure hydraulic oil to control the hydraulic system of a marine engine was developed. A structural analysis was performed on the main parts of the pump to ensure the structural safety in the design. Using a pump testing equipment, performance characteristics such as no-load flow rate, load flow rate, flow rate according to the swivel angle change, flow rate with lubrication orifice, and response time according to the swivel motion were tested. Consequently, the pump was confirmed to satisfy the required specifications.

공정열교환기 소형 시제품에 대한 고온구조해석(IV) - 거시적 고온 탄·소성 구조해석을 중심으로 - (High-Temperature Structural Analysis of a Small-Scale Prototype of a Process Heat Exchanger (IV) - Macroscopic High-Temperature Elastic-Plastic Analysis -)

  • 송기남;홍성덕;박홍윤
    • 대한기계학회논문집A
    • /
    • 제35권10호
    • /
    • pp.1249-1255
    • /
    • 2011
  • 공정열교환기는 초고온가스로로부터 생성된 $950^{\circ}C$ 정도의 초고온 열을 대량의 수소를 생산하기 위한 화학반응공정으로 전달하는데 필요한 핵심기기이다. Hastelloy-X 로 제작된 소형 공정열교환기 시제품이 한국원자력연구원에 있는 소형가스루프에서 성능시험이 계획되어 있다. 본 연구에서는 소형가스루프 시험조건하에서 소형 공정열교환기 시제품의 고온 구조건전성을 사전에 평가하기 위한 작업의 일환으로 소형 공정열교환기 시제품에 대한 고온 구조해석 모델링, 거시적 열 해석 및 탄 소성구조 해석을 수행하고 그 결과들을 정리한 것이다. 해석 결과는 공정열교환기 수정 시제품 성능시험장치 설계에 반영할 것이다.

메가와트급 부유식 해상풍력발전기용 페어리드 체인 스토퍼의 강도 성능평가를 위한 구조 모형 시험 (Structural Model Test for Strength Performance Evaluation of Fairlead Chain Stopper Installed on MW Class Floating Type Offshore Wind Turbine)

  • 송창용
    • 한국산업융합학회 논문집
    • /
    • 제26권3호
    • /
    • pp.421-431
    • /
    • 2023
  • Recently, the destructive power of typhoons is continuously increasing due to the influence of global warming. In a situation where the installation of floating wind turbines is increasing around the world, concerns about the huge loss and collapse of floating offshore wind turbines due to strong typhoons are deepening. Regarding to the safe operation of the floating offshore wind turbine, the development of a new type of disconnectable mooring system is required. A new fairlead chain stopper considered in this study is devised to more easily attach or detach the floating offshore wind turbine with mooring lines comparing to other disconnectable mooring apparatuses. In order to investigate the structural safety of the initial design of fairlead chain stopper that can be applied to MW-class floating type offshore wind turbine, scale-down structural models were produced using a 3-D printer and structural tests were performed on the models. For the structural tests of the scale-down models, tensile specimens of acrylonitrile butadiene styrene material that was used in the 3-D printing were prepared, and the material properties were evaluated by performing the tensile tests. The finite element analysis of fairlead chain stopper was performed by applying the material properties obtained from the tensile tests and the same load and boundary conditions as in the scale-down model structural tests. Through the finite element analysis, the structural weak parts on the fairlead chain stopper were reviewed. The structural model tests were performed considering the main load conditions of fairlead chain stopper, and the test results were compared to the finite element analysis. Through the results of this study, it was possible to experimentally verify the structural safety of the initial design of fairlead chain stopper. It is also judged that the study results can be usefully used to improve the structural strength of fairlead chain stopper in a detailed design stage.

차량 부품의 내구성 평가를 위한 가상시험실 구축 (The Durability Performance Evaluation of Automotive Components in the Virtual Testing Laboratory)

  • 김기훈;강우종;김대성;고웅희;임재용
    • 한국자동차공학회논문집
    • /
    • 제14권3호
    • /
    • pp.68-74
    • /
    • 2006
  • The evaluation of durability performance in Virtual Testing Laboratory(VTL) is a new concept of vehicle design, which can reduce the automotive design period and cost. In this study, the multibody dynamics model of a car is built with a reverse engineering design. Hard points and masses of components are measured by a surface scanning device and imported into CAD system. In order to simulate the non-linear dynamic behavior of force elements such as dampers and bushes, components and materials are tested with specialized test equipments. An optimized numerical model for the damping behavior is used and the hysteresis of bush rubber is considered in the simulation. Loads of components are calculated in VTL and used in the evaluation of durability performance. In order to verify simulation results, loads of components in the vehicle are measured and durability tests are performed.

Performance validation and application of a mixed force-displacement loading strategy for bi-directional hybrid simulation

  • Wang, Zhen;Tan, Qiyang;Shi, Pengfei;Yang, Ge;Zhu, Siyu;Xu, Guoshan;Wu, Bin;Sun, Jianyun
    • Smart Structures and Systems
    • /
    • 제26권3호
    • /
    • pp.373-390
    • /
    • 2020
  • Hybrid simulation (HS) is a versatile tool for structural performance evaluation under dynamic loads. Although real structural responses are often multiple-directional owing to an eccentric mass/stiffness of the structure and/or excitations not along structural major axes, few HS in this field takes into account structural responses in multiple directions. Multi-directional loading is more challenging than uni-directional loading as there is a nonlinear transformation between actuator and specimen coordinate systems, increasing the difficulty of suppressing loading error. Moreover, redundant actuators may exist in multi-directional hybrid simulations of large-scale structures, which requires the loading strategy to contain ineffective loading of multiple actuators. To address these issues, lately a new strategy was conceived for accurate reproduction of desired displacements in bi-directional hybrid simulations (BHS), which is characterized in two features, i.e., iterative displacement command updating based on the Jacobian matrix considering nonlinear geometric relationships, and force-based control for compensating ineffective forces of redundant actuators. This paper performs performance validation and application of this new mixed loading strategy. In particular, virtual BHS considering linear and nonlinear specimen models, and the diversity of actuator properties were carried out. A validation test was implemented with a steel frame specimen. A real application of this strategy to BHS on a full-scale 2-story frame specimen was performed. Studies showed that this strategy exhibited excellent tracking performance for the measured displacements of the control point and remarkable compensation for ineffective forces of the redundant actuator. This strategy was demonstrated to be capable of accurately and effectively reproducing the desired displacements in large-scale BHS.

Bond behavior between concrete and prefabricated Ultra High-Performance Fiber-Reinforced Concrete (UHPFRC) plates

  • Mansour, Walid;Sakr, Mohammed A.;Seleemah, Ayman A.;Tayeh, Bassam A.;Khalifa, Tarek M.
    • Structural Engineering and Mechanics
    • /
    • 제81권3호
    • /
    • pp.305-316
    • /
    • 2022
  • Externally bonded ultrahigh performance fiber-reinforced concrete (UHPFRC) is commonly used as a strengthening material for reinforced concrete (RC) structures. This study reports the results of an experimental program investigating the bonding behavior between concrete and prefabricated UHPFRC plates. The overall experimental program is consisting of five RC specimens, which are strengthened using the different lengths and widths of prefabricated UHPFRC plates. These specimens were analyzed using the pull-pull double-shear test. The performance of each strengthened specimen is presented, discussed and compared in terms of failure mode, maximum load, load-slip relationship, fracture energy and strain distribution. Specimen C-25-160-300 which bonded along the whole width of 160 mm recorded the highest maximum load (109.2 kN) among all the analysed specimens. Moreover, a 3D numerical finite element model (FEM) is proposed to simulate the bond behavior between concrete and UHPFRC plates. Moreover, this study reviews the analytical models that can predict the relationship between the maximum bond stress and slip for strengthened concrete elements. The proposed FEM is verified against the experimental program and then used to test 36 RC specimens strengthened with prefabricated UHPFRC plates with different concrete grades and UHPFRC plate widths. The obtained results together with the review of analytical models helped in the formation of a design equation for estimating the bond stress between concrete and prefabricated UHPFRC plates.

단열 보완형 복합방수공법의 단열성능에 관한 연구 (Thermal Insulation Performance of Composite Waterproofing Method of Thermal Supplement Type)

  • 최성민
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제18권4호
    • /
    • pp.59-66
    • /
    • 2014
  • 건설구조물 상부의 단열은 에너지 절약 건설구조물에 있어서 중요한 요건 중 하나이다. 건설구조물 최상부는 단열성뿐만 아니라 방수성능도 중요하다. 이와 같은 이유로 단열성을 확보한 방수공법의 개발이 요구된다. 본 연구에서는 최근 일정 단열성능을 확보한 단열 보완형의 복합방수공법이 개발되어 해당 공법에 대한 단열성능을 평가하고자 하였다. 방수성 시험결과, 모든 시험체는 KS 표준 이상의 성능을 보여주었다. 단열성 시험결과, 스티로폼 박스가 가장 높은 온도인 $25.91^{\circ}C$, 버블시트 박스가 $17.28^{\circ}C$, 단열시트 박스가 $15.47^{\circ}C$, 단열보완형 방수시트가 $24.11^{\circ}C$로 확인되었다. 시트 접합부의 열교현상을 관찰한 결과 열교현상은 발생하지 않았다. 단열보완형 복합방수공법은 단열성능을 확보하고 있는 것으로 판단된다.

철근이 부식된 콘크리트 슬래브의 구조성능 평가에 대한 실험적 연구 (Reinforced Concrete Slabs with Corroded Bars)

  • 정은철;이경언;정란
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회논문집(I)
    • /
    • pp.718-723
    • /
    • 2000
  • Corrosion is a world wide problem effecting a large number of structure. Cost of repair and rehabilitation on reinforcement structure damaged by steel corrosion is expensive. But structural capacity on low level corrosion is increased. So this experimental study was performed to know structural performance on reinforced concrete slabs with low level corroded bars. As in the case of test samples, bond stress and structural capacity increases up to 2% corrosion level.

  • PDF

가압경수로 핵연료 지지격자의 기계/구조적 설계 및 분석 (Design and Analyses on the Spacer Grid of the PLWR Fuel)

  • 송기남
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.746-751
    • /
    • 2001
  • Design requirements for the nuclear fuel assembly grid of the pressurized water reactor are reviewed from the mechanical/structural point of view. And mechanical/structural tests and numerical analyses on the various spacer grid candidates that has been uniquely designed by KAERI are carried out to find out their mechanical/structural performance. As a result, the results from the numerical analyses are good agreements with test results.

  • PDF