• Title/Summary/Keyword: structural performance test

Search Result 2,156, Processing Time 0.024 seconds

Structural identification and seismic performance of brick chimneys, Tokoname, Japan

  • Aoki, T.;Sabia, D.
    • Structural Engineering and Mechanics
    • /
    • v.21 no.5
    • /
    • pp.553-570
    • /
    • 2005
  • Dynamic and static analyses of existing structures are very important to obtain reliable information relating to actual structural properties. For this purpose a series of material test, dynamic test and static collapse test of the existing two brick chimneys, in Tokoname, are carried out. From the material tests, Young's modulus and compressive strength of the brick used for these chimneys are estimated to be 3200 MPa and 7.5 MPa, respectively. The results of static collapse test of the existing two brick chimneys are discussed in this paper and composed with the results from FEA (Finite Element analysis). From the results of dynamic tests, the fundamental frequencies of Howa and Iwata brick chimneys are estimated to be about 2.69 Hz and 2.93 Hz, respectively. Their natural modes are identified by ARMAV (Autoregressive Moving Average Vectors) model. On the basis of the static and dynamic experimental tests, a numerical model has been prepared. According to the European code (Eurocode n. 8: "Design of structures for earthquake resistance") non-linear static (Pushover) analysis of the two chimneys is carried out and they seem to be vulnerable to earthquakes with 0.25 to 0.35 g.

Performance Evaluation of the Full-Scale Active Mass Dampers based on a Numerical Model and Test (실물크기 능동형 제어장치의 수치모델 및 실험에 기초한 성능 평가)

  • Jeon, Min-Jun;Lee, Sang-Hyun;Woo, Sung-Sik;Mun, Dae-Ho
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.6
    • /
    • pp.635-643
    • /
    • 2015
  • In this study, the experimental test results are given to confirm the control efficiency of the linear control algorithm used for designing the active mass dampers(AMD) which are supposed to be installed at Incheon international airport control tower. The comparison between the results from test and numerical analysis is conducted and it was observed that the AMD showed the control performance expected by the numerical model. The effects of the gain scheduling and constant-velocity signal added to the control signal calculated by the algorithm is identified through the observation that the AMD always show behavior within the given stroke limit without any loss of the desired control performance. The phase difference between the accelerations of the structure and the AMD were almost close to 90 degree, which implies that the AMD absorbed the structural energy effectively.

Development of a Precast Concrete Structural Wall Adopting Improved Connections in the Plastic Hinge Region (소성힌지 영역의 접합부를 개선한 PC 구조벽체의 개발)

  • Kang, Su-Min;Oh, Jae-Keun;Kim, Ook-Jong;Lee, Do-Bum;Park, Hong-Gun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.14 no.2
    • /
    • pp.15-26
    • /
    • 2010
  • The purpose of this study is to develop a precast concrete structural wall system that can assure reliable seismic performance. In previous studies, the connections of precast concrete structural walls have had some problems in their seismic performance. Therefore, this research proposes precast concrete structural walls which have an improved seismic performance. One is a hybrid precast concrete structural wall that is composed of a reinforced concrete component and a precast concrete component, and another is a precast concrete wall whose reinforcements have a partially reduced section and are partially unbonded from the surrounding concrete. To evaluate the seismic performance of the proposed precast concrete structural walls, the behavior of three specimens, including a reinforced concrete wall, were subjected to reversed cyclic combined flexure and shear. According to the test results, the proposed precast concrete structural walls have reliable seismic performance.

Experimental Study on the Fire Performance of PC Slab by the Bearing Length (걸침길이에 따른 PC 슬래브의 화재성능에 관한 실험적 연구)

  • Park, Siyoung;Kang, Thomas H.K.;Lee, Ho-Wook;Gwak, Si-Young;Park, Jun-Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.14-22
    • /
    • 2022
  • In this study, a fire test was conducted to evaluate the fire performance of precast concrete (PC) slabs in an outdoor environment in response to the increase in fire incidents caused by the growth of warehouses. Prior to the field fire test, the tensile yield strength of the tendon at elevated temperatures was tested to analyze the mechanical properties. Also, by referring to previous studies, the thermal properties of tendon and the mechanical and thermal properties of concrete were investigated. A field fire test was conducted to analyze the structural and fire performance of two identical slabs with 50 and 150 mm bearing length. As the bearing length increased, deflection and horizontal displacement decreased. The fire test lasted for 200 minutes without the collapse of slabs, validating current codes. Based on the structural performance which maintained even with concrete spalling and rupture of some tendons, the bonded method is assumed to be practical in pre-tensioned PC slabs. The results of fire test are expected to be utilized in evaluating the fire performance of PC slabs in warehouses.

Performance Evaluation of Scale-down Concrete Filled FRP Columns (축소모형실험을 통한 콘크리트 충전 FRP 합성교각의 성능 평가)

  • Youm, Kwang-Soo;Lee, Seung-Hwe;Lee, Young-Ho;Song, Jae-Joon;Hwang, Yoon-Koog
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.1 s.53
    • /
    • pp.135-144
    • /
    • 2009
  • The present paper represents experimental studies on the performance of concrete filled FRP columns. Eight scale-down specimens were conducted by quasi-static cyclic loading test. FRP thickness, concrete strength, horizontal rebar ratio, and diameter were selected as test parameters. The capacities of ductility for cyclic loading was evaluated and the damping ratio and failure mode from the stiffness reduction of each test specimen were compared.

Improvement and Evaluation of Structural performance of Reinforced Concrete Infilled Masonry Frame with Restraining Factor of Frame under Load Reversals (반복하중을 받는 철근콘크리트 프레임면내 조적벽체의 골조 구속에 따른 구조성능 평가 및 개선)

  • 신종학;하기주;김광연;이희종;남왕교
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.541-546
    • /
    • 2001
  • Experimental programs were accomplished to improve and evaluate the structural performance of test specimens, such as the hysteretic behavior, the maximum horizontal strength, crack propagation of and ductility etc. Test variables are restraining factors of frame, with or without masonry infilled wall, and masonry method Six reinforced concrete rigid frame and masonry infilled wall were tested and constructed in one-third scale size under vertical and cyclic loads simultaneously. Based on the test results, the following conclusions can be made. For masonry infilled wall with restraining factors of frame, maximum horizontal capacities were increased by 1.91~2.24 times in comparision with that of rigid frame. For masonry infilled wall with restraining factors of frame(IFWB-l~3), cumulated energy dissipation capacities wear increased by 1.35~l.60 times in comparision with that of masonry infilled wall(IFB-1) at final stage of testing.

  • PDF

Experimental Study on the Structural Performance of Hybrid Friction Damper (혼합형 마찰댐퍼 구조성능에 대한 실험적 연구)

  • Kim, Do-Hyun;Kim, Ji-Young
    • Journal of Korean Association for Spatial Structures
    • /
    • v.15 no.3
    • /
    • pp.103-110
    • /
    • 2015
  • Various hybrid dampers have been developed as increasing tall buildings in Korea. To minimize the installment space and cost, the new hybrid friction damper was developed using friction components. It is composed of two one-nodal rotary frictional components and a slotted bolted frictional connection. Because of these components, hybrid friction damper can be activated by building movements due to lateral forces such as a wind and earthquake. In this paper, displacement amplitude dependency tests were carried out to evaluate on the structural performance and the multi-slip mechanism of the hybrid damper. Test results show that the multi-slip mechanism is verified and friction coefficients are increasing as displacement amplitudes are increasing.

Structural Performance Test of Optimized Outer Tie Rod (아우터타이로드 최적화 모델의 구조성능시험)

  • Kim, Jong-Kyu;Seo, Sun-Min;Kim, Young-Jun;Lee, Dong-Jin;Lee, Seul;Park, Young-Chul;Lee, Kwon-Hee
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.5
    • /
    • pp.82-87
    • /
    • 2012
  • The outer tie rod that is a part of steering system connects the steering gear to the steering knuckle via the inner tie rod. The formal study suggested the optimized structural design of an outer tie rod installed in a passenger car. Its weight is 284.7g, which is 57.2% lighter weight than initial steel model. This study validates the optimized design of the outer tie rod considering buckling and durability. The assembled unit of an inner tie rod and outer tie rod is utilized to perform the test of the bending strength of the outer tie rod. On the contrary, 1/2 car is utilized to perform the test of its durability performance.

Structural Performance of Reinforcement corrosion RC Beams Strengthened with Epoxy Mortar System (에폭시모르타르로 보강된 부식철근 RC보의 구조적 성능)

  • Han, Bok-Kyu;Hong, Geon-Ho;Shin, Yeong-Soo;Chung, Lan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.769-774
    • /
    • 2000
  • The purpose of this study was to investigate the structural performance of reinforcement corrosion reinforced concrete beams strengthened with epoxy mortar system. Main test parameters are existence and the magnitude of the reinforcement corrosion and the reinforcing bar and the tensile reinforcement ratio of the specimens. eight beam specimens were tested to investigate the effectiveness of each test variables on maximum load capacity and failure mode. Test results showed that the ultimate moment of th specimens were higher tan the nominal moment and the flexural stiffness was increased about 2.5 times and the cracking moments occurred over 60% of the failure moment in comparison with same sized control beam. However, note that epoxy mortar may conduct member into brittle failure mode.

  • PDF

Design and Analysis of UHF-GPS Antenna for Autonomous Underwater Vehicles (자율무인잠수정용 UHF-GPS 안테나 설계 및 해석)

  • Sang-Jin Park;Yeong-Jun Jo;Dong-Hyun Seo;Lin-Keun Park
    • Journal of Advanced Navigation Technology
    • /
    • v.26 no.6
    • /
    • pp.464-473
    • /
    • 2022
  • In this paper, about a lightweight design that satisfies the performance of UHF-GPS Antenna used in autonomous underwater vehicle is proposed. Structural analysis, watertight external pressure test and non-destructive testing used in the design process are decided in consideration of structural safety for operating external forces in the underwater environment. First, the material of radome is selected for the performance of the UHF-GPS Antenna for communication with the carrier on the underwater operation in consideration of the 20 bar pressure generated. And the material of radome as PA-GF is selected by conducting electromagnetic field analysis and structural analysis and by considering high strength, rigidity and high dielectric constant. Electromagnetic field analysis and structural analysis by the thickness of radome are additionally performed in order to satisfy the required weight of UHF-GPS antenna. After selecting the final model, its structural safety is verified through watertight external pressure test and non-destructive testing.