• Title/Summary/Keyword: structural hazards

Search Result 124, Processing Time 0.027 seconds

Study on failure mechanism of multi-storeyed reinforced concrete framed structures

  • Ahmed, Irfan;Sheikh, Tariq Ahmad;Gajalakshmi, P.;Revathy, J.
    • Advances in Computational Design
    • /
    • v.6 no.1
    • /
    • pp.1-13
    • /
    • 2021
  • Failure of a Multi-storeyed reinforced concrete framed structure occurs when a primary vertical structural component is isolated or made fragile, due to artificial or natural hazards. Load carried by vertical component (column) is transferred to neighbouring columns in the structure, if the neighbouring column is incompetent of holding the extra load, this leads to the progressive failure of neighbouring members and finally to the failure of partial or whole structure. The collapsing system frequently seeks alternative load path in order to stay alive. One of the imperative features of collapse is that the final damage is not relative to the initial damage. In this paper, the effect on the column and beam adjacent to statically removed vertical element in terms of axial force, shear force and bending moment is investigated. Using Alternate load path method, numerical modelling of two dimensional one bay, two bay with variation in storey heights are analysed with FE model in order to obtain better understanding of failure mechanism of multi-storeyed reinforced concrete framed structure. The results indicate that the corner column is more susceptible to progressive collapse when compared to middle column, using this simplified methodology one can easily predict how the structure can be made to stay alive in case of sudden failure of any horizontal or vertical structural element before designing.

The dynamic response of adjacent structures with the shallow foundation of different height and distance on liquefiable saturated sand

  • Jilei Hu;Luoyan Wang;Wenxiang Shen;Fengjun Wei;Rendong Guo;Jing Wang
    • Earthquakes and Structures
    • /
    • v.25 no.2
    • /
    • pp.135-148
    • /
    • 2023
  • The structure-soil-structure interaction (SSSI) effect in adjacent structures may affect the liquefaction-induced damage of shallow foundation structures. The existing studies only analysed the independent effects on the structural dynamic response but ignored the coupling effect of height difference and distance of adjacent structures (F) on liquefied foundations on the dynamic response. Therefore, this paper adopts finite element and finite difference coupled dynamic analysis method to discuss the effect of the F on the seismic response of shallow foundation structures. The results show that the effect of the short structure on the acceleration response of the tall structure can be neglected as F increases when the height difference reaches 2 times the height of the short structure. The beneficial effect of SSSI on short structures is weakened under strong seismic excitations, and the effect of the increase of F on the settlement ratio gradually decreases, which causes a larger rotation hazard. When the distance is smaller than the foundation width, the short structure will exceed the rotation critical value and cause structural damage. When the distance is larger than the foundation width, the rotation angle is within the safe range (0.02 rad).

Regional Seismic Risk Assessment for Structural Damage to Buildings in Korea (국내 건축물 지진피해 위험도의 지역단위 평가)

  • Ahn, Sook-Jin;Park, Ji-Hun;Kim, Hye-Won
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.27 no.6
    • /
    • pp.265-273
    • /
    • 2023
  • This study proposes a methodology for the regional seismic risk assessment of structural damage to buildings in Korea based on evaluating individual buildings, considering inconsistency between the administrative district border and grid lines to define seismic hazard. The accuracy of seismic hazards was enhanced by subdividing the current 2km-sized grids into ones with a smaller size. Considering the enhancement of the Korean seismic design code in 2005, existing seismic fragility functions for seismically designed buildings are revised by modifying the capacity spectrum according to the changes in seismic design load. A seismic risk index in building damage is defined using the total damaged floor area considering building size differences. The proposed seismic risk index was calculated for buildings in 29 administrative districts in 'A' city in Korea to validate the proposed assessment algorithm and risk index. In the validation procedure, sensitivity analysis was performed on the grid size, quantitative building damage measure, and seismic fragility function update.

Adaptive Finite Element Mesh Generation Schemes for Dynamic Structural Analyses

  • Yoon, Chong-Yul
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.1
    • /
    • pp.23-28
    • /
    • 2010
  • Reliable dynamic analysis is essential in order to properly maintain structures so that structural hazards may be minimized. The finite element method (FEM) is proven to be an affective approximate method of structural analysis if proper element types and meshes are chosen. When the method is applied to dynamics analyzed in time domain, the meshes may need to be modified at each time step. As many meshes need to be generated, adaptive mesh generation schemes have become an important part in complex time domain dynamic finite element analyses of structures. In this paper, an adaptive mesh generation scheme for dynamic finite element analyses of structures is described. The concept of representative strain value is used for error estimates and the refinements of meshes use combinations of the h-method (node movement) and the r-method (element division). The validity of the scheme is shown through a cantilever beam example under a concentrated load with varying values. The example shows reasonable accuracy and efficient computing time. Furthermore, the study shows the potential for the scheme's effective use in complex structural dynamic problems such as those under seismic or erratic wind loads.

Post-seismic assessment of existing constructions: evaluation of the shakemaps for identifying exclusion zones in Emilia

  • Braga, Franco;Gigliotti, Rosario;Monti, Giorgio;Morelli, Francesco;Nuti, Camillo;Salvatore, Walter;Vanzi, Ivo
    • Earthquakes and Structures
    • /
    • v.8 no.1
    • /
    • pp.37-56
    • /
    • 2015
  • The Emilia, May-July 2012, earthquake has dramatically highlighted the only the hazards facing the people in insufficiently secured workplaces, but also the socio-economic consequences of interruption of production activities. After the event, in order to guarantee suitable safety levels, the Italian government asked for a generalized seismic retrofit of buildingsaffected by the earthquake under consideration. Considering that Emilia is one of the most industrialized Italian region, the number of the industrial buildings to be verified could however lead to not acceptable resumption of production time. So, with the aim to speed up the recovery, were leaved out from this request the buildings which had undergone a strong enoughshaking without any damage. In practice, the earthquakes were being used as a "test" to evaluate the seismic structural strength. Besides, the Italian government provision specifies also the zones, within which buildings that escaped evident damage are exempt from obligatory checks, and termed "exclusion zones", shall be individuated using the data provided by the Italian National Institute of Geophysics and Volcanology in the form of so-called "shakemaps". Obviously, the precision of such data greatly influences the determination of the exclusions zones and so all the economic issues related to them. Starting from these considerations, the present paper describes an evaluation of the reliability of the procedure of shakemap generation with specific regard to the seismic events that struck the Emilia region on May 20 and 29, 2012.

Study on the Physical Properties of the Artificial Lightweight Aggregate Recycled from the Dyestuff Sludge Treated Chemically With Ti and Fe Salt (Ti염 및 Fe염으로 화학처리된 염색공단 슬러지를 재활용한 인공경량골재의 물리적 특성에 관한 연구)

  • Choi, Jong-Oh;Jung, Yong-Wook
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.3 no.1
    • /
    • pp.34-42
    • /
    • 2015
  • The paper investigates environmental hazards and characteristics of the artificial lightweight aggregate manufactured by using dyestuff sludge from dyeing industrial complex. The dyestuff sludge used in this study is chemically treated with Ti and Fe salt for the purpose of recycling. The artificial lightweight aggregate is manufactured through 3 step; 1) Selecting the optimum moisture content by evaluating plasticity from the mixing ratio of the clay and sludge, 2) shaping round type based on the optimum mixing ratio, 3) drying and Sintering process. Based on KS F 2534 "Lightweight Aggregate for Structural concrete", the particle size, fineness modulus, the density, absorption, unit volume weight, stability and environmental hazards of the manufactured lightweight aggregate are evaluated. Experimental results show that the particle size and fineness modulus is out of the range. However, it is observed that other physical properties are within criteria. In addition, it is confirmed that the problem of the particle size and fineness modulus could be solved in the manufacturing process.

Impact of waste crumb rubber on concrete performance incorporating silica fume and fly ash to make a sustainable low carbon concrete

  • Muhammad, Akbar;Zahoor, Hussain;Pan, Huali;Muhammad, Imran;Blessen Skariah, Thomas
    • Structural Engineering and Mechanics
    • /
    • v.85 no.2
    • /
    • pp.275-287
    • /
    • 2023
  • The use of environmental-friendly building materials is becoming increasingly popular worldwide. Compared to the normal concrete, rubber-based concrete is considered more durable, environmentally friendly, socially and economically viable. In this investigation, M20 grade concrete was designed and the fine aggregates were replaced with crumb rubber of two different micron sizes (0.221 mm and 0.350 mm). Fly ash (FA) and silica fume (SF) replaces the binder as supplementary cementitious materials at a rate of 0, 5, 10, 15, and 20% by weight. The mechanical properties of concrete including compressive strength, tensile, and flexural strength were determined. The polynomial work expectation validates the response surface approach (RSM) concept for optimizing SF and FA substitution. The maximum compressive strength (22.53 MPa) can be observed for the concrete containing 10% crumb rubber, 15% fly ash and 15% silica fume. The reduced unit weight of the rubberized concrete may be attributed to the lower specific gravity of the rubber particles. Two-way ANOVA with a significance criterion of less than 0.001 has been utilized with modest residual error from the lack of fit and the pure error. The predictive model accurately forecasts the variable-response relationship. Since, the crumb rubber is obtained from wasted tires incorporating FA and SF as a cementitious ingredient, it helps to significantly improve mechanical properties of concrete and reduce environmental degradation.

Markov-based time-varying risk assessment of the subway station considering mainshock and aftershock hazards

  • Wei Che;Pengfei Chang;Mingyi Sun
    • Earthquakes and Structures
    • /
    • v.24 no.4
    • /
    • pp.303-316
    • /
    • 2023
  • Rapid post-earthquake damage estimation of subway stations is particularly necessary to improve short-term crisis management and safety measures of urban subway systems after a destructive earthquake. The conventional Performance-Based Earthquake Engineering (PBEE) framework with constant earthquake occurrence rate is invalid to estimate the aftershock risk because of the time-varying rate of aftershocks and the uncertainty of mainshock-damaged state before the occurrence of aftershocks. This study presents a time-varying probabilistic seismic risk assessment framework for underground structures considering mainshock and aftershock hazards. A discrete non-omogeneous Markov process is adopted to quantify the time-varying nature of aftershock hazard and the uncertainties of structural damage states following mainshock. The time-varying seismic risk of a typical rectangular frame subway station is assessed under mainshock-only (MS) hazard and mainshock-aftershock (MSAS) hazard. The results show that the probabilities of exceeding same limit states over the service life under MSAS hazard are larger than the values under MS hazard. For the same probability of exceedance, the higher response demands are found when aftershocks are considered. As the severity of damage state for the station structure increases, the difference of the probability of exceedance increases when aftershocks are considered. PSDR=1.0% is used as the collapse prevention performance criteria for the subway station is reasonable for both the MS hazard and MSAS hazard. However, if the effect of aftershock hazard is neglected, it can significantly underestimate the response demands and the uncertainties of potential damage states for the subway station over the service life.

Estimation of the Maximum Potential Earthquake from the Fault Parameters (단층요소로부터 최대 잠재지진 평가에 관해서)

  • 장천중
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.10a
    • /
    • pp.33-40
    • /
    • 2000
  • The assessment of earthquake hazards involved consideration of earthquake magnitude, frequency, last movement and probability of occurrence. The appraisal of earthquake potential is feasible because historical data show a good correlation between earthquake size and the fault rupture parameters of length, displacement, and area. Additionally, the characteristics of fault behavior should be considered to evaluate the earthquake potential magnitude. In this study, in order to evaluate the earth quake potential by the fault behavioral patterns, based on the experimental background which the geometric characteristics of the individual domains, such as strike, width, fault tip patterns, and orientation of secondary shears reflect sliding behavioral patterns in each section, the straight sections of A, D and E domains were examined to the creeping section of stably sliding. In contrast, the curved section of B domain was examined to the locked section of stick-slip movement. These results of studies can be applied to evaluate the earthquake potential magnitude from the fault structural parameters.

  • PDF

CHOOSING AN NIR INSTRUMENT AND A SAMPLE PRESENTATION OPTION PLANT AND SOIL ANALYSIS

  • Batten, Graeme-D;Blakeney, Anthony-B;Susan Ciavarella
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1022-1022
    • /
    • 2001
  • To obtain accurate and repeatable analyses using NIR technology it is important to select an NIR instrument and / or its sample presentation attachments which allow the operator to minimize sampling errors without compromising the benefits of NIR analysis -namely rapid, low cost, minimal sample preparation, minimal structural facilities, minimal hazards. For each sample type and consistency there may be different optimal combinations of instrument, sample presentation attachment, and sample preparation. This paper will consider options available to NIR users in the area of plant and soil analysis and evaluate the potential benefits and disadvantages of crop nutrient diagnoses using laboratory based and airborne imaging techniques.

  • PDF