• Title/Summary/Keyword: structural fire resistance

Search Result 260, Processing Time 0.028 seconds

Derivation of the Mechanical Properties of Structural Steels at High Temperatures (고열 환경에서의 구조용 강재 특성 데이터베이스 구축)

  • Kwon, In-Kyu
    • Fire Science and Engineering
    • /
    • v.21 no.3
    • /
    • pp.47-55
    • /
    • 2007
  • The mechanical properties such as 0.2% and 1% offset proof strength and elastic modulus are essential for a structural steel structure when the structure would be evaluated and designed to identify the performance of the structural stability exposed to fire condition. To obtain the mechanical properties for the structural steels at high temperature which are consisted of ordinary and marine ones, the tensile tests at various high temperatures had been conducted with two kinds of specimen of general structural steel SS 400 and welded steel SM 490 at the range of room temperature to $900^{\circ}C$ at interval of $100^{\circ}C$.

Efficiency of insulation layers in fire protection of FRP-confined RC columns-numerical study

  • El-Mahdya, Osama O.;Hamdy, Gehan A.;Hisham, Mohammed
    • Structural Engineering and Mechanics
    • /
    • v.77 no.5
    • /
    • pp.673-689
    • /
    • 2021
  • This paper addresses the efficiency of thermal insulation layers applied to protect structural elements strengthened by fiber-reinforced polymers (FRP) in the case of fire event. The paper presents numerical modeling and nonlinear analysis of reinforced concrete (RC) columns externally strengthened by FRP and protected by thermal insulation layers when subjected to elevated temperature specified by standard fire tests, in order to predict their residual capacity and fire endurance. The adopted numerical approach uses commercial software includes heat transfer, variation of thermal and mechanical properties of concrete, steel reinforcement, FRP and insulation material with elevated temperature. The numerical results show good agreement with published results of full-scale fire tests. A parametric study was conducted to investigate the influence of several variables on the structural response and residual capacity of insulated FRP-confined columns loaded by service loads when exposed to fire. The residual capacity of FRP-confined RC column was affected by concrete grade and insulation material and was shown to improve substantially by increasing the concrete cover and insulation layer thickness. By increasing the VG insulation layer thickness 15, 32, 44, 57 mm, the loss in column capacity after 5 hours of fire was 30%, 13%, 7% and 5%, respectively. The obtained results demonstrate the validity of the presented approach for estimation of fire endurance and residual strength, as an alternative for fire testing, and for design of fire protection layers for FRP-confined RC columns.

An Examining and Analyzing Study on the Fire Resistance Design for Immersed Tunnels (침매터널 내화설계에 관한 조사 분석적 연구)

  • Lee, Young-Jae;Kim, Heung-Youl;Shin, Hyun-Jun;Kim, Hyung-Jun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.507-512
    • /
    • 2008
  • Recently, Busan-Geoje fixed Link Immersed Tunnel and the Tokyo Port Waterway 2 Submarine Tunnel have been constructing. Furthermore it was mentioned to construct an immersed tunnel from Korea to Japan. As a result, it is expected that the demand to use the immersed tunnel will be increased. However, if a fire occurs in the immersed tunnels, it will damage tunnel elements and not save human lives more seriously than normal tunnels on the ground because of the absence of exits as well as closing structure of the immersed tunnels. In fact, the fire accident in the Eurotunnel which connects between France and the Unite Kingdom through the immersed tunnel had occurred twice in 1996 and 2008, and the inner surface of the tunnel got damaged such as concrete popout and structural damage. As a result, not only economic injury but enormous expense to repair and reinforce the tunnel were derived because of the suspension of traffic after the fire happened. Now, from the examining and analyzing study on the fire resistance of immersed tunnels in developed countries and Busan-Geoje fixed Link Immersed Tunnel, we suggest the establishment method of fire resistance to insure the fire safety of immersed tunnel.

  • PDF

Review of fire resistance evaluation and fire resistance method of concrete segment lining for fire in tunnel (터널 내 화재발생에 대한 콘크리트 세그먼트 라이닝의 내화성 평가 및 내화방법에 대한 고찰)

  • Moorak Son;Juhyun Cheon;Youngkeun Cho;Bumjoo Kim
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.25 no.2
    • /
    • pp.121-139
    • /
    • 2023
  • Various tunnels such as road, subway, and railway are under construction and operation. Various types of linings are used for structural stability of tunnel structures, and concrete segment linings are mainly installed in TBM tunnel construction. In this paper, when a fire occurs in a tunnel, the impact on the concrete segment lining, which is the structure in the tunnel, and related standards, fire resistance evaluation and fire resistance method are investigated through literature review and related contents are presented. Through this, it is intended to provide an information for practitioners to secure the safety of concrete segment linings against tunnel fires.

A numerical analysis on the performance of buckling restrained braces at fire-study of the gap filler effect

  • Talebi, Elnaz;Tahir, Mahmood Md.;Zahmatkesh, Farshad;Kueh, Ahmad B.H.
    • Steel and Composite Structures
    • /
    • v.19 no.3
    • /
    • pp.661-678
    • /
    • 2015
  • Buckling Restrained Braces (BRB) have been widely used in the construction industry as they utilize the most desirable properties of both constituent materials, i.e., steel and concrete. They present excellent structural qualities such as high load bearing capacity, ductility, energy-absorption capability and good structural fire behaviour. The effects of size and type of filler material in the existed gap at the steel core-concrete interface as well as the element's cross sectional shape, on BRB's fire resistance capacity was investigated in this paper. A nonlinear sequentially-coupled thermal-stress three-dimensional model was presented and validated by experimental results. Variation of the samples was described by three groups containing, the steel cores with the same cross section areas and equal yield strength but different materials (metal and concrete) and sizes for the gap. Responses in terms of temperature distribution, critical temperature, heating elapsed time and contraction level of BRB element were examined. The study showed that the superior fire performance of BRB was obtained by altering the filler material in the gap from metal to concrete as well as by increasing the size of the gap. Also, cylindrical BRB performed better under fire conditions compared to the rectangular cross section.

Experimental and numerical studies on the shear connectors in steel-concrete composite beams at fire and post fire exposures

  • Mirza, Olivia;Shil, Sukanta Kumer;Rashed, M.G.;Wilkins, Kathryn
    • Steel and Composite Structures
    • /
    • v.39 no.5
    • /
    • pp.529-542
    • /
    • 2021
  • Shear connectors are required to build composite (concrete and steel) beams. They are placed at the interface of concrete and steel to transfer shear and normal forces between two structural components. Such composite beams are sensitive to provide structural integrity when exposed to fire as they loss strength, stiffness, and ductility at elevated temperature. The present study is designed to investigate the shear resistance and the failure modes of the headed stud shear connectors at fire exposure and post-fire exposure. The study includes ordinary concrete and concrete with carbon nanotubes (CNTs) to build composite (concrete-steel) beams with structural steel. Experimental push tests were conducted on composite beams at ambient and elevated temperatures, such as 200, 400 & 600℃. Moreover, push tests were performed on the composite beams after being exposed to 200, 400 & 600℃. Push test results illustrated the reduction of ultimate shear capacity and stiffness of headed stud shear connectors as the temperature increased. Although similar values of ultimate shear were obtained for the headed stud connectors in both ordinary and CNT concrete, the CNT modified concrete reduced the concrete spalling and cracking compared to ordinary concrete and was observed to be effective at temperatures greater than 400℃. All specimens showed a lower shear resistance at fire exposures compared to the corresponding post-fire exposures. Moreover, numerical simulation by Finite Element (FE) analyses were carried out at ambient temperature and at fire conditions. The FE analysis results show a good agreement with the experimental results. In the experimental studies, failure of all specimens occurred due to shear failure of headed stud, which was later validated by FE analyses using ABAQUS.

A Study on the Structural Fire Resistance Performance Design of RC Structural according to the Explosive Spalling(I) - The Countermeasures of General Construction Company - (폭렬현상을 고려한 RC구조물의 PBD기반 구조내화설계 기술개발에 관한 연구(I) - 국내외 주요 건설사의 대응방안 -)

  • Lee, Jae-Young;Kim, Se-Jong;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.195-201
    • /
    • 2008
  • When reinforced concrete is subjected to high temperature as in fire, there is deterioration in its properties of particular importance are loss in compressive strength, cracking and spalling of concrete, destruction of the bond between the cement paste and the aggregates and the gradual deterioration of the hardend cement paste. Assessment of fire-damaged concrete usually starts with visual observation of color change, cracking and spalling of the surface. In this paper, it was reported the trends of research and practical use on the Explosive Spalling Properties of the High-Strength Concrete.

  • PDF

A Study on the Shape of Beam Attached CFT inner-side for Developing Column's Performance (콘크리트충전 강관기둥의 성능향상을 위한 내면부착 beam의 형상 연구)

  • Lee, Dong-Un;Yun, Hyug-Gee;Kim, Dea-Geon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.21-22
    • /
    • 2015
  • The CFT(Concrete Filled Tube) system has been developed to behave well in a structural performance such as stiffness, stress, ductility, fire resistance that is derived from its mechanical advantages of composite structure. There were number of studies about unprotected CFT columns for improving their fire resistance through reinforcing bars or plates being placed inside the steel tube. It was also known that reinforcing plates of flat type need stiffeners in a certain distance to avoid their buckling failure so it cost as much as their using consequentially. This paper is planned to test the work of beam elements attached inner side of CFT depending on its shape. More discussions on beam's design could be followed after some fire tests accordingly conducted within this project.

  • PDF

Fire Resistance of Concrete-Filled Circular Steel Tube Columns under Central Axial Loads (일정 축력을 받는 콘크리트충전 원형 강관기둥의 내화성능 평가)

  • Park, Su Hee;Song, Kyung Chul;Ryoo, Jae Yong;Chung, Kyung Soo;Choi, Sung Mo
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.5
    • /
    • pp.655-663
    • /
    • 2008
  • In this research, the fire resistance of Concrete-Filled Circular Steel Tube Columns (CFT) was evaluated by numerical analysis. As the materials of CFT columns, the steel of SPSR 400 grade and the concrete of 27.5MPa, 37.8MPa strengths were used. Significant parameters,such as concrete strength, axial load, and cross-sectional dimensions were determined. To verify the accuracy of the numerical analysis,the analysis results were compared with the former experiment results. The effect of the fire resistance time, axial load ratio, cross-sectional dimensions and concrete strength was evaluated by comparison with the fire resistance of the square CFT columns. This research showed that the structural behavior and fire resistance from the findings of numerical parametric studies showed a similarity to that of the experimental results. Therefore, this numerical analysis is reasonable in estimating the fire resistance of the circular CFT column.

Comparative Analysis of Fire Resistance in Glued Laminated Timber: The Impact of Adhesives and Surface Direction (구조용 집성재의 접착제 종류 및 접착면 방향성에 따른 내화성능 비교 분석)

  • Choi, Yun-Jeong;An, Jae-Hong;Baik, Kwon-hyuk
    • Journal of the Korea Institute of Building Construction
    • /
    • v.23 no.6
    • /
    • pp.761-772
    • /
    • 2023
  • The fire resistance design of timber structures involves calculating the residual section based on charring depth, which is then utilized in structural design. Charring depth is determined from fire-resistance test results in Korea, which currently do not account for the charring properties of the adhesive used in Glued Laminated Timber(GLT) production. This study fabricated GLT using various adhesives employed in domestic GLT production, comparing the charring properties by adhesive type and the fire resistance performance relative to the directionality of the laminated surface. Melamine demonstrated the most advantageous fire resistance performance, followed by resorcinol and polyurethane. Furthermore, it was established that the laminated section exhibited a higher charring rate, influenced by the adhesive, compared to the laminated surface, which significantly impacts the fire resistance performance.