• Title/Summary/Keyword: striping

Search Result 69, Processing Time 0.024 seconds

LARGE EDDY SIMULATION OF THERMAL STRIPING IN THE UPPER PLENUM OF FAST REACTOR (대와동모사법을 사용한 고속로 상부플레넘에서의 thermal sriping 해석)

  • Choi, S.K.;Han, J.W.;Kim, D.;Lee, T.H.
    • Journal of computational fluids engineering
    • /
    • v.19 no.4
    • /
    • pp.29-36
    • /
    • 2014
  • A computational study of a thermal striping in the upper plenum of PGSFR(Prototype Generation-IV Sodium-cooled Fast Reactor) being developed at the KAERI(Korea Atomic Energy Research Institute) is presented. The LES(Large Eddy Simulation) approach is employed for the simulation of thermal striping in the upper plenum of the PGSFR. The LES is performed using the WALE (Wall-Adapting Local Eddy-viscosity) model. More than 19.7 million unstructured elements are generated in upper plenum region of the PGSFR using the CFX-Mesh commercial code. The time-averaged velocity components and temperature field in the complicated upper plenum of the PGSFR are presented. The time history of temperature fluctuation at the eight locations of solid walls of UIS(Upper Internal Structure) and IHX(Intermediate Heat eXchanger) are additionally stored. It has been confirmed that the most vulnerable regions to thermal striping are the first plate of UIS. From the temporal variation of temperature at the solid walls, it was possible to find the locations where the thermal stress is large and need to assess whether the solid structures can endure the thermal stress during the reactor life time.

The study of striping size according to the amount of storage nodes in the Parallel Media Stream Server (병렬 미디어 스트림 서버에서 저장노드수의 변화에 따른 스트라이핑 크기 결정에 관한 연구)

  • Kim, Seo-Gyun;Nam, Ji-Seung
    • The KIPS Transactions:PartC
    • /
    • v.8C no.6
    • /
    • pp.765-774
    • /
    • 2001
  • In this paper, we proposed the striping policy for the storage nodes in the Linux-based parallel media stream server. We newly developed a storage clustering architecture, and named it as a system RAID architecture. In this system, many storage cluster nodes are grouped to operate as a single server. This system uses unique striping policy to distribute multimedia files into the parallel storage nodes. If a service request occurs, each storage cluster node transmits striped files concurrently to the clients. This scheme can provide the fair distribution of the preprocessing load in all storage cluster nodes. The feature of this system is a relative striping policy based on the file types, service types, and the number of storage nodes to provide the best service.

  • PDF

Elimination of JERS-1 OPS Image Striping Effect (JERS-1 OPS영상의 줄무늬 현상 제거 알고리즘)

  • 신동석;이영란
    • Korean Journal of Remote Sensing
    • /
    • v.14 no.1
    • /
    • pp.95-101
    • /
    • 1998
  • This paper describes an algorithm which was developed for removing along-track and across-track striping effect shown in JERS-1 OPS/VNIR images. A statistical algorithm was implemented based on the mean brightness value of each along-track and across-track line. Different from any filtering techniques in either spatial or frequency domain, the developed algorithm does not change the radiometric characteristics of image pixels. The algorithm will be inserted to the JERS-1 OPS image data processing chain in the Satellite Technology Research Center direct receiving station.

Design and Implementation of Fault Tolerant parallel server with double striping (이중 스트라이핑을 이용한 Fault Tolerant 병렬서버의 설계와 구현)

  • 이민홍;김경훈;김서균;남지승
    • Proceedings of the IEEK Conference
    • /
    • 2002.06c
    • /
    • pp.75-78
    • /
    • 2002
  • In this paper, we present the design and implementation of a Fault Tolerant VOD system. The system uses the double striping policy that a original file is sequentially striped to multiple streaming server with constant data block size and the data block of one streaming server is re-striped to the other streaming server. When a fault occurs in one streaming server, automatically the other streaming server will service.

  • PDF

Dynamic Scheme Transition for On-Demand Video Streaming Adaptable to Variable Client Request Rate (다양한 클라이언트 요청율에 적용가능한 주문형 비디오 스트리밍을 위한 동적 스킴 트랜지션 기법)

  • Kim Hyun-Joo;Yeom Heon-Young
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.12 no.3
    • /
    • pp.149-159
    • /
    • 2006
  • To provide on-demand video streaming services through the network, video objects with both high and low client request rates should be served efficiently. In this paper, we propose a dynamic on-demand streaming approach for providing services efficiently regardless of the client request rate. This approach can maintain QoS by transitioning the service scheme according to the request rate. The server provides services by the Heuristic broadcasting approach when the client request rate is low and by Striping broadcast, one of many Periodic broadcast approaches, when the client request rate is high. The server knows the variations of client request rates by the number of service channels and decides the transition to more efficient service schemes on its own. We simulated this scheme transition with various client request intervals and traces from a company providing streaming services. The results show that the performance of our approach is reasonable.

The SZIT based-mapping method for on-line adding disks in software RAID (소프트웨어 RAID에서 온라인 디스크 부착이 가능한 SZIT 기반 매핑 기법)

  • Bak, Yu-hyeon;Kim, Chang-soo;Kang, Dong-jae;Kim, Young-ho;Shin, Bum-joo
    • The KIPS Transactions:PartA
    • /
    • v.9A no.4
    • /
    • pp.535-546
    • /
    • 2002
  • According as the users can connect to remote hosts at anytime by using internet, the demand of non-stop system is increased. Also, the research about on-line adding/deleting disks and hosts are progressed. This paper suggests that the method of reducing additional operation when we add disks to the stripping system. That method can fast mapping like equation based mapping method because of using so-called SZIT(Striping Zone Information Table) and equations. And that method can reduce the relocation overhead in striping system at adding disks.

Efficient striping policy of NOD data on clustered storage server (Clustered Storage Server 환경에서 뉴스 데이터에 적합한 분산 저장방법)

  • 정귀옥;박성호;김영주;정기동
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 1998.10a
    • /
    • pp.89-91
    • /
    • 1998
  • 현대 사회의 정보 요구 증가와 편리함의 추구는 정보통신 기술의 발달과 함께 멀티미디어 데이터 서비스를 급증 시켰다. NOD 데이터의 경우 이러한 요구에 부합하므로, 많은 사용자를 가지게 될 것이며, 그에 따른 제반 요건으로 서버 구현에서 scalability, availability, reliability 등이 중요한 요건이다. 따라서 이러한 요건을 멀티미디어 데이터 특성을 이용한 저장 방법으로 만족시키려는 많은 연구가 있다. 그러나 NOD 시스템에 대한 연구는 미흡한 실정이며 clustered 환경에서의 New 데이터에 대한 연구는 거의 없다. VOD 데이터에 적합한 것으로 알려진 일반적인 저장 방법이 NOD 데이터에 반드시 적합한 것이 아니며, 본 논문에서는 기존에 연구된 데이터 저장 방법 중에서 NOD 데이터의 small volume, skewed popularity distribution 등의 특성을 고려하여 clustered storage server환경에 맞는 striping 정책을 찾는다.

  • PDF

Evaluation of thermal striping damage for a tee-junction of LMR secondary piping”

  • Lee, Hyeong-Yeon;Kim, Jong-Bum;Bong Yoo;Yoon, Sam-Son
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.837-843
    • /
    • 1998
  • This paper presents the thermomechanical and fracture mechanics evaluation procedure of thermal striping damage on the secondary piping of LMFR using Green's function method and standard FEM. The thermohydraulic loading conditions used in the present analysis are simplified sinusoidal thermal loads and the random type data thermal load. The thermomechainical fatigue damage was evaluated according to ASME code subsectionNH. The analysis results of fatigue for the sinusoidal and random load cases show that fatigue failure would occur at a geometrically discontinuous location during 90,000 hours of operation The fracture mechanics analysis showed that the crack would be initiated at an early stage of the operation. The fatigue crack was evaluated to propagate up to 5 ㎜ along the thickness direction during the first 944 and 1083 hours of operation for the sinusoidal and the random loading cases, respectively.

  • PDF

Real-Time Storage and Retrieval Techniques for Continuous Media Storage Server (연속미디어 저장 서버에서의 실시간 저장 및 검색 기법)

  • CheolSu Lim
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.32B no.11
    • /
    • pp.1365-1373
    • /
    • 1995
  • In this paper, we address the issues related to storage and retrieval of continuous media (CM)data we face in designing multimedia on-demand (MOD) storage servers. To support the two orthogonal factors of MOD server design, i.e., storage and retrieval of CM data, this paper discusses the techniques of disk layout, disk striping and real-time disk scheduling, which are integrated as a combined solution to the high- performance MOD storage subsystem. The proposed clustered striping technique enables either a multiple-disk or a parallel system to guarantee a continuous retrieval of CM data at the bandwidth required to support user playback rate by avoiding the formation of I/O bottlenecks.

  • PDF

Hybrid Striping Scheme for Improving Disk Access Time in Multi-DB (다중 DB환경에서의 디스크 접근 속도 향상을 위한 하이브리드 스트라이핑 기법)

  • 오창석;임성화;김재훈;고영배
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2003.04a
    • /
    • pp.79-81
    • /
    • 2003
  • 스트라이핑(striping) 기법은 여러 개의 디스크에 데이터를 병렬적으로 분산하여 저장함으로써 데이터 접근 속도를 높이기 위하여 제안되었다. 그러나 서로 다른 데이터를 요청하는 다수의 사용자 요구 환경에서 스트라이핑 기법은 seektime과 rotational latency의 증가로 인해. 오히려 I/O 성능이 저하될 수 있다. 본 논문에서는 서로 다른 데이터 요구율을 갖는 다중 데이터베이스 액세스 환경에서 스트라이핑 폭(width)에 의한 입출력 성능을 분석하고, 사용자 요구 형태에 따라 스트라이핑 디스크 그룹과 개별 디스크 그룹으로 디스크 풀(pool)을 나누어 처리하는 하이브리드 스트라이핑 방식을 제안한다. 제안 방식의 성능 향상은 시뮬레이션에 의하여 검증하였다.

  • PDF