• Title/Summary/Keyword: stress and displacement

Search Result 2,274, Processing Time 0.028 seconds

Numerical analysis of the Influence of the presence of disbond region in adhesive layer on the stress intensity factors (SIF) and crack opening displacement (COD) in plates repaired with a composite patch

  • Benchiha, Aicha;Madani, Kouider;Touzain, Sebastien;Feaugas, Xavier;Ratwani, Mohan
    • Steel and Composite Structures
    • /
    • v.20 no.4
    • /
    • pp.951-962
    • /
    • 2016
  • The determination of the stress intensity factor at the crack tip is one of the most widely used methods to predict the fatigue life of aircraft structures. This prediction is more complicated for repaired cracks with bonded composite patch. This study is used to compute the stress intensity factor (SIF) and crack opening displacement (COD) for cracks repaired with single and double-sided composite patches. The effect of the presence of disbond region in adhesive at the crack was taken into consideration. The results show that there is a considerable reduction in the asymptotic value of the stress-intensity factors and the crack opening displacement at the crack tip. The use of a double-sided patch suppresses the bending effect due to the eccentricity of the patch on one side only.

Development of Stress, Load and Displacement Controlled Direct Shear Apparatus for Jointed Rock (응력, 하중, 변위제어 방식의 암석 절리면 전단시험기의 개발)

  • 김대영;천병식;서영호;이영남
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.03a
    • /
    • pp.471-477
    • /
    • 1999
  • A new stress, load and displacement controlled direct shear apparatus has recently been developed at the Hyundai Institute of Construction Technology This direct shear apparatus is capable of testing of rock joint under constant normal stiffness, constant normal stress or constant normal load boundary conditions. This paper describes this direct shear apparatus and illustrates results of shear tests at constant normal stress condition, constant normal load condition and constant normal stiffness condition with dental stones which have a same joint roughness and unconfined compressive strength.

  • PDF

Structural performance monitoring of an urban footbridge

  • Xi, P.S.;Ye, X.W.;Jin, T.;Chen, B.
    • Structural Monitoring and Maintenance
    • /
    • v.5 no.1
    • /
    • pp.129-150
    • /
    • 2018
  • This paper presents the structural performance monitoring of an urban footbridge located in Hangzhou, China. The structural health monitoring (SHM) system is designed and implemented for the footbridge to monitor the structural responses of the footbridge and to ensure the structural safety during the period of operation. The monitoring data of stress and displacement measured by the fiber Bragg grating (FBG)-based sensors installed at the critical locations are used to analyze and assess the operation performance of the footbridge. A linear regression method is applied to separate the temperature effect from the stress monitoring data measured by the FBG-based strain sensors. In addition, the static vertical displacement of the footbridge measured by the FBG-based hydrostatic level gauges are presented and compared with the dynamic displacement remotely measured by a machine vision-based measurement system. Based on the examination of the monitored stress and displacement data, the structural safety evaluation is executed in combination with the defined condition index.

A Simulation on the Displacement Stress of Cement in Porcelain Insulators for Transmission Line (송전용 자기재 애자의 시멘트 변위 응력에 관한 시뮬레이션)

  • Han, S.W.;Cho, H.G.;Woo, B.C.;Jung, G.C.;Lee, D.I.;Choi, I.H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.476-479
    • /
    • 2002
  • The ageing cause in many porcelain suspension insulators which occur on transmission and distribution line with dead-end stings is mechanical stress in interface between porcelain and cement materials. It is known that the principal mechanical stress which give electrical failure is the results of the displacement is due to cement growth. We studied the effect of cement displacement resulting environmental ageing parameters on porcelain insulator mechanical properties for transmission line by simulation (ANSYS/NASTRAN program) and test methods. These simulation analysis and experimental results show that cement volume growth affects severely to be mechanical failure ageing.

  • PDF

STRESS ANALYSIS OF ENDODONTICALLY TREATED ANTERIOR TEETH BY ALVEOLAR BONE HEIGHT AND RESTORATION METHOD (근관치료를 받은 전치부에서 수복방법과 치조골높이에 따른 응력분석에 관한 연구)

  • Lee, Yeon-Jae;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.16 no.1
    • /
    • pp.133-150
    • /
    • 1991
  • To study the mechanical behavior depended on the restoration method and alveolar bone height at endodontically treated teeth. a finite element model was made which was applied by four types of restoration methods and alveolar bone height on upper central incisor and then 1 Kg force was applied on each model as follows; 1) $45^{\circ}$ diagonal load on incisal edge. 2) $26^{\circ}$ diagonal load on lingual surface. and 3) horizontal load on labial surface. The author analyzed the displacement and stress of teeth and their supporting tissue by finite element method according to three type of loading conditions. The results were as follows : 1. The displacement by restoration method and the stress in dentin was found greater in restoration without a post than in that with a post. 2. The displacement and stress was found about the same when compared : A) in Resin model and PFM model applied by restoration method without a post and B) in PRC model and CPC model applied by restoration method with a post. 3. The lower alveolar bone height was. the greater was the displacement and stress. 4. The lower alveolar bone height was. the greater slightly was the stress of restoration without a post than in that with a post. 5. The stress in loading condition was the greatest in P1 in dentin and post. and was greatest in P3 in alveolar hone. 6. In the restoration method without a post. stress concentration in labial dentin was distributed to a figure of long belt in adjacent part to periodontal ligament. while in restoration method with a post. it was distributed in adjacent part to post side. And in all types of restoration method stress concentration in alveolar bone was distributed along the compact bone of labial and lingual surface.

  • PDF

Influence of Density Variation on Stress and Displacement Fields at a Propagating Mode-III Crack Tip in Orthotropic Functionally Graded Materials (밀도변화가 직교이방성함수구배재료에서 전파하는 모드 III 균열선단의 응력 및 변위장에 미치는 영향)

  • Lee, Kwang-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.9
    • /
    • pp.1051-1061
    • /
    • 2011
  • The influences of density variation on stress and displacement fields at a propagating Mode-III crack tip in orthotropic functionally graded materials (OFGMs) are studied. The crack propagates dynamically at a right angle to the gradient of physical properties. Three kinds of elasticity and density gradients are analyzed in this study. They are as follows: (1) the density varies without elasticity variation, (2) the directions of the density and elasticity gradients are opposite to each other, and (3) same. For these cases, the stress and displacement fields at the crack tip are developed and the dynamic stress intensity factors for propagating cracks are also studied. When the crack speed is low, the influence of density variation on the stresses and displacement is low. However, when the crack speed is high, this influence is very high.

Static assessment of quadratic hybrid plane stress element using non-conforming displacement modes and modified shape functions

  • Chun, Kyoung-Sik;Kassegne, Samuel Kinde;Park, Won-Tae
    • Structural Engineering and Mechanics
    • /
    • v.29 no.6
    • /
    • pp.643-658
    • /
    • 2008
  • In this paper, we present a quadratic element model based on non-conforming displacement modes and modified shape functions. This new and refined 8-node hybrid stress plane element consists of two additional non-conforming modes that are added to the translational degree of freedom to improve the behavior of a membrane component. Further, the modification of the shape functions through quadratic polynomials in x-y coordinates enables retaining reasonable accuracy even when the element becomes considerably distorted. To establish its accuracy and efficiency, the element is compared with existing elements and - over a wide range of mesh distortions - it is demonstrated to be exceptionally accurate in predicting displacements and stresses.

Structural Safety Analysis on Car Body at Overturn (전복시 차체에 대한 구조 안전 해석)

  • Cho, Jae-Ung;Kim, Key-Sun;Lee, Eun-Jong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.1
    • /
    • pp.32-37
    • /
    • 2011
  • In this study, the changes of displacement and stress are investigated by structural analysis according to the thickness of car body in case of overturn. In case of 5 mm thickness, the maximum displacement of 7.5024 mm at its right ceiling and the maximum equivalent stress of 113.69 MPa at the left lower part are occurred on the elapsed time of 2 second. In case of 10 mm thickness, the maximum displacement of 1.2557 mm at its right ceiling and the maximum equivalent stress of 15.134 MPa at the left lower part are occurred on the elapsed time of 2 second. In case of 15 mm thickness, the maximum displacement of 0.426067 mm at its right ceiling and the maximum equivalent stress of 4.4842 MPa at the left lower part are occurred on the elapsed time of 2 second. As stress and displacement are uniformly distributed according to time in this case, the design of car body can be stabilized.

In situ Stress Measurements with Submonolayer Sensitivity As a Probe of Coherent-to-incoherent Matching at an Interface in Ultrathin Magnetic Films

  • Jeong, Jong-Ryul;Kim, Young-Seok;Shin, Sung-Chul
    • Journal of Magnetics
    • /
    • v.7 no.4
    • /
    • pp.151-155
    • /
    • 2002
  • In situ stress changes at interfaces of ultrathin magnetic films were measured by means of a non-contact optical fiber bundle displacement detector. A bending of the substrate due to stress of a deposited film was detected in cantilever geometry. The highest sensitivity of 134 mV/$\mu$m for the displacement detector was realized with a help of computer simulation. The detector was applied to in situ stress measurements of Co/Pt and Ni/Pd magnetic multilayer films prepared on the glass substrates by dc magnetron sputtering. The detector turned out to have a submonolayer sensitivity that enables to observe coherent-to-incoherent transition in these mismatched multilayers and even detect the stress changes within the monoatomic coverage. This highly sensitive detector paves new way to probe the stress relaxation at an interface in ultrathin films.

THREE-DIMENSIONAL FINITE ELEMENT STRESS ANALYSIS OF THE JAWS AT THE SIMULATED BILATERAL AND UNILATERAL CLENCHINGS (양측성 및 편측성 이악물기시 상하악골 응력변화 및 변위에 관한 3차원 유한요소법적 연구)

  • Heo, Hoon;Kang, Dong-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.1
    • /
    • pp.71-92
    • /
    • 1999
  • This study is to analyze the stress and displacement on the jaws during the bilateral and unilateral clenching task on three dimensional finite element model of the dentated skull. For this study, the computed tomography(G.E.8800 Quick, USA) was used to scan the total length of human skull in the frontal plane at 1.9mm intervals. The CAD data were extracted from the tomograms through digitizer(Summa Sketch III, USA) and then reconstructed by means of the spline method in the CAD program. In this project, a commercial software I-DEAS(Master Series ver-sion 3.0, SDRC Inc, USA) was used for three-dimensional stress analysis on the finite element model. which consists of articular disc, maxilla, mandible, teeth, periodontal ligament and cranium. The results are as follows. ; 1. During the bilateral clenching, each major muscle forces caused high stresses on various areas of skull: masseter muscle on articular disc and teeth ; temporal muscle on mandible and periodontal ligament ; medial pterygoid muscle on the temporomandibular joint. During the unilateral clenching, masseter muscle induced the maximum stress ; medial pterygoid muscle the minimum stress. 2. During the bilateral clenching, higher compressive stresses on articular disc were generated by the masseter muscle and higher deformation occurred on the most front outer sites. And during the unilateral clenching, temporal muscle and medial pterygoid muscle exerted their forces to twist temporomandibular joint area of the balancing side and induced a higher compressive stresses on the front outer sites of articular disc. 3. During the bilateral clenching, the masseter muscle bended the mandible outwardly, and then caused tensile stresses on the lingual surface of mandibular symphysis. And the medial pterygoid muscle caused tensile stresses on the labial surface of mandibular symphysis. 4. When each muscles were simultaneously applied on jaws, a high stress and displacement took place on mandible rather than on the maxilla. Also, a high stress and displacement took place during the unilateral clenching rather than during the bilateral clenching.

  • PDF