• 제목/요약/키워드: strengthening repair

검색결과 154건 처리시간 0.029초

유리섬유보강 박판패널에 의한 철근콘크리트 구조물의 보수.보강공법 (Repair and Strengthening of R/C Structure Using Glass Fiber Reinforced Plastic Thin Panels)

  • 천의균;진형장;박석암;김행준
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.866-873
    • /
    • 2000
  • Reinforced concrete structure can be strengthened by glass fiber reinforced plastic thin panels. The GFRP-Thin Panels are manufactured by pressing form and their application technique are similar to steel plates. The use of FGRP-Thin Panels presents several advantages. The advantages of this structural system are the case of application, the elimination of joint and corrosion at the epoxy-panel interface. This paper introduces the method of manufacturing about GFRP-Thin Panels, mechanical properties and the application of reinforced concrete structures.

  • PDF

보수.보강재료 및 공법개발연구 (Development of Repair Materials and Rehabilitation Techniques)

  • 송병표;한만엽;황의승;홍영균
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 봄 학술발표회 논문집
    • /
    • pp.592-597
    • /
    • 1997
  • Many strengthening methods are introduced and used to rehabilitate existing structures. However, both theoretical background and application techniques are not. One of the most popular methods is bonded plate method using either steel plate or carbon plate. For bonded plate method, bonding at the end of the plate is the most important properties. In this study, a method to reduce the stress distribution at the end of the bonded plate is found and tested. The results showed that the proposed end anchoring method is effective.

  • PDF

수중부 하부 구조의 보수 보강 (Examples for Underwater Repair and Strengthening of Bridge Substructures)

  • 유동우
    • 콘크리트학회지
    • /
    • 제13권2호
    • /
    • pp.38-43
    • /
    • 2001
  • 교량 하부구조 특히 교각 및 기초의 경우는 지반 또는 수중에 묻혀 있기 때문에 손상을 발견하기도 어렵고 또한 손상의 보수 및 보강이 곤란한 경우가 많다. 하부구조의 손상은 지반의 마모, 침하, 측방유동토압, 하상세굴, 홍수류, 선박 및 유하물에 의한 충격, 지진 등의 여러 원인에 의하여 발생된다. 이러한 손상은 지표수 및 지하수 배제공, 성토공, 지반개량공, 단면보수공, 세굴방지공, 내진보강공 등에 의하여 보수 및 보강이 행하여 진다. 본 고에서는 이러한 하부구조의 보수.보강공법 중 수중부에 실시되는 방법에 대하여 소개하고자 한다.

네트형 외부 긴장재에 의한 슬래브교 보강 실험 (An Experimental Study About a Net-Type External Prestress Strengthening Method for Slab Bridges)

  • 한만엽;강태헌;최석환
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제15권5호
    • /
    • pp.136-149
    • /
    • 2011
  • 국내의 지형 특성으로 인해서 교량의 많은 부분이 슬래브교 형식이다. 차량이 대형화하고 교통량이 증가하면서 노후 슬래브교의 보강이 필요한 경우가 많다. 본 연구에서는 노후화된 슬래브교를 효과적으로 보강할 수 있는 외부 긴장재 보강공법을 제안하였다. 종방향 및 횡방향 외부 프리스트레싱을 이용한 네트형 보강법은 슬래브 중앙부의 처짐을 효과적으로 보강할 수 있는 방법이며, 하부공간을 침해하지 않으므로 실제 적용성이 뛰어나다. 실험을 통해서 제안한 보강법으로 인해서 향상되는 내하력의 크기를 검증하였다. 실험에서는 세 가지 서로 다른 하중조건에 대하여 처짐 및 변형률을 계측하여 보강의 효과를 비교, 분석하였다. 네트형 긴장재 보강 전후의 휨강성의 증가량은 재하 종류별로 30.7~107.3% 증가하였다. 보강 전후 처짐의 감소율은 27.6~52.2%에 달하였다. 종방향 및 횡방향 프리스트레싱으로 인한 네트형 보강법은 슬래브교의 중앙부 보강에 매우 효과적이며, 중앙에 집중되는 하중 뿐만 아니라 편기 재하되는 하중에 대해서도 유사한 보강효과가 있다. 또한 네트형 보강법은 필요에 따라 재긴장이 가능하므로 유지보수 및 사용성 측면에서 장점이라 할 수 있다.

선하중(先荷重)을 받은 RC보의 CFRP-Rod 휨보강 효과에 대한 실험적 연구 (An Experimental Study on the Flexural Behavior of Pre-loaded RC Beams Strengthened with CFRP-Rod)

  • 예상민;천우철;강주원;박성무
    • 한국공간구조학회논문집
    • /
    • 제7권1호
    • /
    • pp.79-85
    • /
    • 2007
  • FRP를 이용한 보강법 중에서도 기존에 일반적으로 행해진 보강법은 Plate 또는 Sheet의 형태로 콘크리트 표면에 부착하여 추가적인 강도를 발현하도록 하는 것이다. 그러나 조기 박락파괴, 부착면의 정리, 보강 단부의 앵커시공, 부착면에 대한 내화처리 등의 어려움이 많다. 이러한 문제점들에 대한 방안으로 막대(Rod) 형태인 CFRP-Rod를 보강모체에 홈을 파고 매립하는 NSMR(Near Surface Mounted Reinforcement)공법이 제안되었고, CFRP-Rod의 보강량, 길이, 간격 등의 변수에 의한 휨보강 능력의 평가에 대한 연구가 이루어져왔다. 그러나 구조물에서 CFRP-Rod의 보강은 어느 정도의 하중이 보강부위에 계속 재하된 상태로 보강이 이루어지게 되므로 본 연구에서는 보강전에 가해지는 선하중(Pre-loading)의 크기를 주요변수로 선하중의 크기에 따른 구조물의 거동 특성을 분석하고자 하였고, 선하중의 크기의 결정은 무보강 시험체의 공칭모멘트와의 비로 결정하였다.

  • PDF

볼트 체결된 와이어 로프를 이용한 RC 보의 전단보강에 대한 연구 (Study on the Shear Strengthening of Concrete Beams with Wire Rope Clamped by Bolts)

  • 김선영;송진규;이영욱;변항용
    • 콘크리트학회논문집
    • /
    • 제18권2호
    • /
    • pp.283-290
    • /
    • 2006
  • 본 연구는 와이어 로프를 이용한 비부착 보의 전단보강에 대한 실험에 대한 것이다. 전단보강 방법은 와이어 로프를 보 단면의 외부에 노출시킨 형태로 볼트와 너트로 기계적 정착을 하는 폐쇄형과 U자형이 있다. 폐쇄형 전단보강방법은 슬래브를 관통하여 와이어 로프로 보 단면을 둘러싼 후 슬래브 상부면에서 와이어 로프를 긴장 고정시키는 방법이곤 U자형 전단보강방법은 슬래브 하부면과 접하는 보 옆면의 정착장치에 U자형으로 와이어 로프를 설치하는 방법이다. 콘크리트 압축강도가 24MPa이고 전단스팬비(a/d)가 4인 실험체의 주요변수로 폐쇄형과 U자형에 대해서 보강 간격을 각각 150, 200, 250mm로 하였다. 실험 결과, 와이어 로프를 이용한 전단보강방법은 무보강 실험체에 대해서 폐쇄형과 U자형 보강실험체의 내력의 최대 증가비가 각각 2.88, 1.91배로 증가하였으며, 복부의 초기 사인장균열시의 처짐에 대한 최대전단강도에서의 처짐의 비로 정의한 연성도 크게 증가하였으며, 특히 폐쇄형의 전단보강의 경우 U자형 전단보강방법에 비해 내력 및 연성의 증가가 두드러졌다. 따라서 본 연구는 와이어 로프를 이용한 전단보강방법의 타당성을 평가하기 위한 실험으로서 중요한 가능성을 제시하며, 전단보강 설계 및 시공에 유용한 기초 자료로서 의의가 있다.

An Investigation of fan type anchorages applied to end of CFRP strips

  • Kara, M. Emin;Yasa, Mustafa
    • Steel and Composite Structures
    • /
    • 제15권6호
    • /
    • pp.605-621
    • /
    • 2013
  • CFRP strips are widely used nowadays for repair/strengthening or capacity increase purposes. Sharp bending at the ends of the CFRP strips is frequently encountered at these applications. In this study, Reinforced Concrete (RC) beam specimens that were produced with 10 MPa compression strength concrete were strengthened by using bonded CFRP strips with end anchorages to tension region. The parameters that were investigated in this study are the width of the strip, the number of applied fan anchorages and whether additional layer of CFRP patch is used or not at the strip ends. Specimens were strengthened with 100 mm wide CFRP strips with one or two anchorages at the ends. In addition CFRP patch with two and three anchorages at the ends were tested for investigating the effect of the patches. Specimens that were strengthened with three anchorages at the ends with patches were repeated with 60 and 80 mm wide CFRP strips. The most successful result was obtained from the specimen that was strengthened with 80 mm wide CFRP strips with 3 end anchorages and patches among the others at the experimental program. The numbers of anchorages that were applied to ends of CFRP strips were more effective than the width of the CFRP strips onto strength and stiffness of the specimens. Due to limited space at the ends of the strips at most three anchorages could be applied.

Tensile response of steel/CFRP adhesive bonds for the rehabilitation of civil structures

  • Matta, F.;Karbhari, Vistasp M.;Vitaliani, Renato
    • Structural Engineering and Mechanics
    • /
    • 제20권5호
    • /
    • pp.589-608
    • /
    • 2005
  • There is a growing need for the development and implementation of new methods for the rapid and cost-effective rehabilitation of deteriorating steel structural components to offset the drawbacks related to welding and/or bolting in the field. Carbon fiber reinforced polymer (CFRP) composites provide a potential alternative as externally bonded patches for strengthening and repair of metallic structural members for building and bridge systems. This paper describes results of an investigation of tensile and fatigue response of steel/CFRP joints simulating scenarios of strengthening and crack-patching. It is shown that appropriately designed schemes, even when fabricated with levels of inaccuracy as could be expected in the field, can provide significant strain relief and load transfer capability. A simplified elasto-plastic closed form solution for stress analysis is presented, and validated experimentally. It is shown that the bond development length remains constant in the linear range, whereas it increases as the adhesive is deformed plastically. Fatigue resistance is shown to be at least comparable with the requirements for welded cover plates without attendant decreases in stiffness and strength.

Fire performance of concrete-filled steel tubular columns strengthened by CFRP

  • Tao, Zhong;Wang, Zhi-Bin;Han, Lin-Hai;Uy, Brian
    • Steel and Composite Structures
    • /
    • 제11권4호
    • /
    • pp.307-324
    • /
    • 2011
  • With the increasing use of concrete-filled steel tubes (CFST) as structural members, there is a growing need to provide suitable measures for possible strengthening or repair of these kinds of structural elements. Fibre reinforced polymer (FRP) jacketing is a recent method and is particularly attractive in which it does not significantly increase the section size, and is relatively easy to install. Thus, it can be used to enhance strength and/or ductility of CFST members. Very little information is available on the performance of FRP-strengthened CFST members under fire conditions. This paper is an attempt to study the fire performance of CFST columns strengthened by FRP. The results of fire endurance tests on FRP-strengthened circular CFST columns are presented. Failure modes of the specimens after exposure to fire, temperatures in the cross section, axial deformation and fire resistance of the composite columns are analysed. It is demonstrated that the required fire endurance can be achieved if the strengthened composite columns are appropriately designed.

구조적 손상을 입은 철근콘크리트 보의 전단보강 효과에 관한 연구 (A Study on the Shear Strengthening Effect of Reinforced Concrete Beams with Structural Damage)

  • 신용석;김정훈;김정섭;김광석;조철희
    • 한국건축시공학회지
    • /
    • 제8권5호
    • /
    • pp.43-51
    • /
    • 2008
  • This study examines shear capacity performance and structural characteristics of reinforced concrete beam using carbon fiber sheet(CFS), g)ass fiber sheet(GFS), glass fiber steel plate(GSP) and carbon fiber bar CB) which are reinforcing materials for reinforced concrete beam in order to produce similar condition to repair and reinforce actual structure and aims to provide data available In designing and constructing reinforced concrete structures under the structural damage. This study obtains the following conclusions. After considering the shear experiment results. it was indicated that the CB reinforced test object was the best in the shear capacity improvement and ductility capacity as it was contained in the concrete and was all operated, Also, GFS reinforced test object indicated the reduced flexural capacity but good shear capacity. GSP reinforced test object had bigger reinforcing strength than other reinforcing test objects. On the other hand, it showed the lowest reinforcement effect as compared section thickness of reinforced material because it showed the bigger relativity a section thickness of reinforced material. If the adherence to the concrete is improved, it will seem to show bigger reinforcement effect.