• 제목/요약/키워드: strength reduction

검색결과 2,880건 처리시간 0.034초

Soil structure interaction effects on strength reduction factors

  • Eser, Muberra;Aydemir, Cem;Ekiz, Lbrahim
    • Structural Engineering and Mechanics
    • /
    • 제41권3호
    • /
    • pp.365-378
    • /
    • 2012
  • In this study, strength reduction factors are investigated for SDOF systems with period range of 0.1-3.0 s with elastoplastic behavior considering soil structure interaction for 64 different earthquake motions recorded on different site conditions such as rock, stiff soil, soft soil and very soft soil. Soil structure interacting systems are modeled and analyzed with effective period, effective damping and effective ductility values differing from fixed-base case. For inelastic time history analyses, Newmark method for step by step time integration was adapted in an in-house computer program. Results are compared with those calculated for fixed-base case. A new equation is proposed for strength reduction factor of interacting system as a function of structural period of system (T), ductility ratio (${\mu}$) and period lengthening ratio (T/T). It is concluded that soil structure interaction reduces the strength reduction factors for soft soils, therefore, using the fixed-base strength reduction factors for interacting systems lead to non-conservative design forces.

감소계수 상호영향을 고려한 지오그리드의 장기성능 해석 (Analysis of Long-Term Performance of Geogrids by Considering Interaction among Reduction Factors)

  • 전한용;김원춘;장연수
    • 한국지반공학회논문집
    • /
    • 제28권7호
    • /
    • pp.55-65
    • /
    • 2012
  • 지오그리드의 장기허용강도를 산출할 때 사용되는 총 감소계수는 내시공성 감소계수($RF_{ID}$), 내화학성 감소계수($RF_D$), 크리프 감소계수($RF_{CR}$) 등이 적용된다. 지오그리드의 단기인장강도에 대한 감소계수를 고려한 허용인장강도 산출 모델의 경우 감소계수들 사이의 상호 작용력을 고려하지 않는 한계를 가지고 있다. 접점강도는 인장강도와 마찬가지로 시공 시 손상이나 화학적 분해에 의하여 감소하게 된다. 기존의 단일접점강도 시험 방법은 치수효과를 고려할 수 없기에 결과의 편차가 큰 시공 시 손상된 시험편의 접점강도를 측정하는데 적합하지 않다. 또한 시공 시 손상에 의한 전단강도 변화에 대한 연구도 전혀 이루어지지 않은 실정이다. 따라서 본 연구에서는 다양한 조건을 고려하여 지오그리드의 장기성능에 영향을 미치는 감소계수들을 재평가하고 감소계수 사이의 상호 작용을 고려하여 정확한 장기허용강도를 구하려고 한다. 내시공성 시험과 내화학성 시험 후 크리프 시험결과 총 감소계수는 GRI GG-4 시험값보다 작게 나타났다. 내시공성 시험과 내화학성 시험 후 접점강도의 감소계수는 인장강도 감소계수보다 더 작게 나타났다. 내시공성 시험후 전단강도 차이가 나타나지 않거나 증가함을 나타내었다.

Modal strength reduction factors for seismic design of plane steel frames

  • Papagiannopoulos, George A.;Beskos, Dimitri E.
    • Earthquakes and Structures
    • /
    • 제2권1호
    • /
    • pp.65-88
    • /
    • 2011
  • A new method for the seismic design of plane steel moment resisting frames is developed. This method determines the design base shear of a plane steel frame through modal synthesis and spectrum analysis utilizing different values of the strength reduction (behavior) factor for the modes considered instead of a single common value of that factor for all these modes as it is the case with current seismic codes. The values of these modal strength reduction factors are derived with the aid of a) design equations that provide equivalent linear modal damping ratios for steel moment resisting frames as functions of period, allowable interstorey drift and damage levels and b) the damping reduction factor that modifies elastic acceleration spectra for high levels of damping. Thus, a new performance-based design method is established. The direct dependence of the modal strength reduction factor on desired interstorey drift and damage levels permits the control of deformations without their determination and secures that deformations will not exceed these levels. By means of certain seismic design examples presented herein, it is demonstrated that the use of different values for the strength reduction factor per mode instead of a single common value for all modes, leads to more accurate results in a more rational way than the code-based ones.

Strength reduction factor for multistory building-soil systems

  • Nik, Farhad Abedi;Khoshnoudian, Faramarz
    • Earthquakes and Structures
    • /
    • 제6권3호
    • /
    • pp.301-316
    • /
    • 2014
  • This paper is devoted to investigate the effects of SSI on strength reduction factor of multistory buildings. A new formula is proposed to estimate strength reduction factors for MDOF structure-soil systems. It is concluded that SSI reduces the strength reduction factor of MDOF systems. The amount of this reduction is relevant to the fundamental period of structure, soil flexibility, aspect ratio and ductility of structure, and could be significantly different from corresponding fixed-base value. Using this formula, measuring the amount of this error could be done with acceptable accuracy. For some practical cases, the error attains up to 50%.

Ultimate strength of stiffened plates with pitting corrosion

  • Rahbar-Ranji, Ahmad;Niamir, Nabi;Zarookian, Arvin
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제7권3호
    • /
    • pp.509-525
    • /
    • 2015
  • Predicting residual strength of corroded plates is of crucial importance for service life estimation of aged structures. A series of nonlinear finite element method is employed for ultimate strength analysis of stiffened plates with pitting corrosion. Influential parameters, including plate thickness, type and size of stiffeners, pit depth and degree of pitting are varied and more than 208 finite element models are analyzed. It is found that ultimate strength is reduced by increasing pit depth to thickness ratio. Thin and intermediate plates have minimum and maximum reduction of ultimate strength with stronger stiffeners, respectively. In weak stiffener, reduction of ultimate strength in thin and intermediate plates depends on DOP. Reduction of ultimate strength in thick plates depends on thickness of plate and DOP. For intermediate plates, reduction for all stiffeners regardless of shape and size are the same.

Design parameter dependent force reduction, strength and response modification factors for the special steel moment-resisting frames

  • Kang, Cheol Kyu;Choi, Byong Jeong
    • Steel and Composite Structures
    • /
    • 제11권4호
    • /
    • pp.273-290
    • /
    • 2011
  • In current ductility-based earthquake-resistant design, the estimation of design forces continues to be carried out with the application of response modification factors on elastic design spectra. It is well-known that the response modification factor (R) takes into account the force reduction, strength, redundancy, and damping of structural systems. The key components of the response modification factor (R) are force reduction ($R_{\mu}$) and strength ($R_S$) factors. However, the response modification and strength factors for structural systems presented in design codes were based on professional judgment and experiences. A numerical study has been accomplished to evaluate force reduction, strength, and response modification factors for special steel moment resisting frames. A total of 72 prototype steel frames were designed based on the recommendations given in the AISC Seismic Provisions and UBC Codes. Number of stories, soil profiles, seismic zone factors, framing systems, and failure mechanisms were considered as the design parameters that influence the response. The effects of the design parameters on force reduction ($R_{\mu}$), strength ($R_S$), and response modification (R) factors were studied. Based on the analysis results, these factors for special steel moment resisting frames are evaluated.

철근콘크리트 휨부재 및 압축부재의 재료조항계수 적용에 관한 연구 (Material Resistance Factors for Reinforced Concrete Flexural and Compression Members)

  • 김재홍;이재훈
    • 콘크리트학회논문집
    • /
    • 제12권2호
    • /
    • pp.21-30
    • /
    • 2000
  • In the Ultimate Strength Design, the design strength of a member is determined by multiplying the strength reduction factor to the nominal strength. This concept may be a reasonable approach, however it can not consider failure modes appropriately. Moreover, column design strength diagram show an abrupt change at a low level of axial load, which does not seem to be reasonable. This research compares the design strength determined by the strength resistance factors. As the material resistance factors for flexure and compression, 0.65 and 0.90 are proposed for concrete and steel, respectively. The design strength calculation process by applying material resistance factors addresses failure modes more effectively than by applying member strength reduction factor, and provides more resnable design strength for reinforced concrete flexural and compression members.

식물성 유지류에 의한 고강도 모르터의 자기수축 저감에 관한 기초적 연구 (A Basic Study on Reduction of Autogenous Shrinkage of High Strength Mortar by Plant Edible Oil)

  • 송일범;백대현;최영화;백병훈;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 춘계 학술논문 발표대회 학계
    • /
    • pp.69-72
    • /
    • 2009
  • This study reviewed the reduction effect of autogenous shrinkage of high strength mortar by plant edible oils based on existing studies, in an effort to find the method of reducing autogenous shrinkage of high strength concrete. To summarize the results, first as characteristics of fresh mortar, substitution of plant edible oil showed slight reduction in liquidity. Compressive strength was reduce at age of 28 days compared to plain mix regardless of type and substitution ratio. Ratio of change in the length of autogenous shrinkage of high strength mortar by plant oils was found to reduce compared to the plain, and the reduction effect was most satisfactorγ in bean oil.

  • PDF

탄소섬유시트 보강보 휨해석에 영향을 미치는 섬유시트 인장강도 감소계수 평가 (Evaluation of CFS Tensile Strength Reduction Factor for Bending Analysis of RC Beams Strengthened with Carbon Fiber Sheets)

  • 윤진섭;이우철;정진환;김성도;조백순
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.359-362
    • /
    • 2003
  • Carbon fiber sheet is attractive due to its good tensile strength, resistance to corrosion, and low weight. The strengthening of concrete structures with externally bonded carbon fiber sheets is increasingly being used for repair and rehabilitation of existing structures. However CFS strengthened beams break down under the service loads. As rupture strain is not reached ultimate value, reduction of the tensile strength is recommended. This study evaluate CFS tensile strength reduction factor which is required to analyze bending moment.

  • PDF

비탄성 요구도 스펙트럼을 이용한 교량구조물의 역량스펙트럼 해석에 대한 강도감소계수의 영향 (Effects of Strength Reduction Factors for Capacity Spectrum Analysis of Bridge Structures using Inelastic Demand Spectrum)

  • 송종걸;김학수;장동휘
    • 대한토목학회논문집
    • /
    • 제28권1A호
    • /
    • pp.25-37
    • /
    • 2008
  • 역량스펙트럼 방법은 그래픽적인 방법으로 간단하게 지진해석을 수행한다. 개발 초기에 역량스펙트럼 방법은 빌딩구조물에 주로 사용되었으나 최근에는 교량구조물에도 사용할 수 있도록 확장되었다. 역량스펙트럼 방법은 비탄성 정적해석으로부터 구한 역량곡선과 유효감쇠 혹은 강도감소계수를 사용하여 선형탄성 설계스펙트럼을 감소시켜 구한 요구도 스펙트럼에 기반을 두고 있다. 본 논문에서는 감소된 요구도 스펙트럼은 강도감소계수에 대한 몇 개의 제안식을 사용하여 구한 비탄성 요구도 스펙트럼을 사용한다. 역량스펙트럼 해석에 대한 강도감소계수의 영향은 세가지 종류의 대칭 및 비대칭 교량에 대하여 평가하였다. 몇 개의 강도감소계수를 적용한 역량스펙트럼 방법의 정확성을 평가하기 위하여, 역량스펙트럼 방법에 의한 최대변위를 8개의 인공지진에 의한 비탄성 시간이력해석 결과와 비교하였다. 강도감소계수 제안식 중 SJ 제안식에 의한 역량스펙트럼 해석의 최대변위가 비탄성 시간이력해석 결과와 가장 일치하는 결과를 나타냄을 알 수 있었다.