• 제목/요약/키워드: strength efficiency factor

검색결과 109건 처리시간 0.026초

Long range-based low-power wireless sensor node

  • Komal Devi;Rita Mahajan;Deepak Bagai
    • ETRI Journal
    • /
    • 제45권4호
    • /
    • pp.570-580
    • /
    • 2023
  • Sensor nodes are the most significant part of a wireless sensor network that offers a powerful combination of sensing, processing, and communication. One major challenge while designing a sensor node is power consumption, as sensor nodes are generally battery-operated. In this study, we proposed the design of a low-power, long range-based wireless sensor node with flexibility, a compact size, and energy efficiency. Furthermore, we improved power performance by adopting an efficient hardware design and proper component selection. The Nano Power Timer Integrated Circuit is used for power management, as it consumes nanoamps of current, resulting in improved battery life. The proposed design achieves an off-time current of 38.17309 nA, which is tiny compared with the design discussed in the existing literature. Battery life is estimated for spreading factors (SFs), ranging from SF7 to SF12. The achieved battery life is 2.54 years for SF12 and 3.94 years for SF7. We present the analysis of current consumption and battery life. Sensor data, received signal strength indicator, and signal-to-noise ratio are visualized using the ThingSpeak network.

고농도 황산염을 함유한 폐수의 혐기성 처리시 메탄균의 효율 향상을 위한 연구 (Improvement of Methanogenic activity in the Anaerobic Treatment of Wastewater with High Sulfate)

  • 신항식;오세은
    • 상하수도학회지
    • /
    • 제10권2호
    • /
    • pp.47-54
    • /
    • 1996
  • UASB reactor was operated for treating wastewater containing high sulfate to assess their performance, competition between sulfate-reducing bacteria(SRB) and methane-producing bacteria(MPB), and the change in the characteristics of microbial granules according to change of hydraulic retention time(HRT) in the reactor. The reactor was fed with a synthetic moderate strength wastes(glucose, 2000 mgCOD/l) containing high sulfate($2400mgSO_4{^{2-}}/l$). The organic loading rate(OLR) ranged from 1.5 to 3.0 gCOD/l.d as HRT maintained 15 to 30 hrs in the stage I. The COD removal efficiency was between 80 to 92%. During this period, methane yield rapidly decreased from 0.3 to 0.1 1 $CH_4$/gCODremoved. While sulfide concentration in the effluent increased from 80 to 200 mgS/l. This indicates that SRB becomes dominant over MPB at a relatively long HRT in the excess sulfate. When OLR of reactor maintained from 5 to 8 gCOD/l.d in the stage II, methane yield increased from 0.1 to 0.17 1 $CH_4$/gCODremoved regardless of decrease of COD removal efficiency. This indicates that SRB is more sensitive to the change of a short HRT than MPB. In the competition between SRB and MPB, about 30% of the removed COD was utilized by SRB at HRT of 30 hrs during the start-up period, while about 73% was used by SRB at HRT of 15hrs at the final step of second experimental stage. Whereas after shock exposure of OLR about 62% was utilized by SRB at HRT of 5hrs. It indicates that SRB is strongly suppressed by the wash-out of significant dispersed SRB since a large electron flow is distributed to the MPB. In addition, the granulation in the presence of high sulfate is unfavoured at a long HRT because of substrate transport limitations into MPB like Methanothrix spp. which is an important factor in the composition of the granules. Accordingly, granule sizes in the UASB reactor decreased with time due to weak network frame of granules by the decreased activity of MPB.

  • PDF

주택의 실내공기질 개선 평가 방법 (Evaluation Method for Improvement Efficiency of Indoor Air Quality in Residence)

  • 양원호;손부순;임성국
    • 한국환경보건학회지
    • /
    • 제33권4호
    • /
    • pp.255-263
    • /
    • 2007
  • Indoor air quality is the dominant contributor to total personal exposure because most people spend a majority of their time indoors. The purposes of this study were to evaluate the alternative method for improvement of indoor air quality in house after coating titanium dioxide ($TiO_2$) photocatalyst for interior part of the house using nitrogen dioxide ($NO_2$) multiple measurements. To evaluate the alternative method in indoor environment, daily indoor and outdoor $NO_2$ concentrations of an apartment and a detached house were daily measured for consecutive 21 days in winter and summer, respectively, Another daily 21 measurements were carried out after $TiO_2$ coating on wall paper of interior part in houses. All $NO_2$ concentrations were measured by passive filter badges. Indoor air quality models using mass balance are useful tool to quantify the relationship between indoor air pollution levels, ambient concentrations, and explanatory variables. Using a mass balance model and linear regression analysis, penetration factor (ventilation rate divided by sum of ventilation rate and decay rate) and source strength factor (emission rate divided by sum of ventilation rate and decay rate) were calculated. Subsequently, the decay constants were estimated. In this study. magnitude of improvement of indoor air quality could be evaluated by decay constant.

프레넬 회절을 이용한 디지털 홀로그램 암호화 알고리즘 (Digital Hologram Encryption Algorithm using Fresnel Diffraction)

  • 이윤혁;서영호;김동욱
    • 방송공학회논문지
    • /
    • 제20권6호
    • /
    • pp.807-817
    • /
    • 2015
  • 본 논문은 고부가가치의 콘텐츠인 디지털 홀로그램을 허락된 사용자만 볼 수 있도록 하는 암호화 방법을 제안한다. 본 논문에서는 프레넬 변환의 특성 즉, 회절거리를 증가시키면 객체영역이 상대적으로 회절평면 일부분에 집중되는 현상을 이용한다. 객체 에너지가 집중되는 영역만을 암호화함으로써 암호화 영역을 크게 줄여 적은 양을 암호화하고도 높은 암호화 효율을 얻는 방법을 제안한다. 그 방법으로는 홀로그램의 복원을 위한 프레넬 변환과 에너지 집중을 위한 프레넬 변환을 통하여 홀로그램 정보를 가운데로 집중시키고 이를 암호화하는 방법이다. 두 번째 프레넬 변환의 파라미터인 회절거리를 조절하여 에너지 집중정도를 결정하고, 가중치를 조절함으로써 암호화 영역의 크기를 조절하여 암호화 강도를 결정한다. 이를 위해 거리와 가중치에 따른 최적의 암호화 지점을 분석한다. 이 암호화 방법을 적용하였을 때 회절거리가 20m일 때 전체 영상의 0.005% ~ 0.02%만 암호화를 하여도 객체정보를 시각적으로 확인할 수 없었다.

아스팔트 표층과 RCC 기층 계면에서의 부착특성 연구 (Bond Characteristics at the Interface between HMA Surface and RCC Base)

  • 홍기;김영규;배석일;이승우
    • 한국도로학회논문집
    • /
    • 제19권6호
    • /
    • pp.37-46
    • /
    • 2017
  • PURPOSES : A composite pavement utilizes both an asphalt surface and a concrete base. Typically, a concrete base layer provides structural capacity, while an asphalt surface layer provides smoothness and riding quality. This pavement type can be used in conjunction with rollercompacted concrete (RCC) pavement as a base layer due to its fast construction, economic efficiency, and structural performance. However, the service life and functionality of composite pavement may be reduced due to interfacial bond failure. Therefore, adequate interfacial bonding between the asphalt surface and the concrete base is essential to achieving monolithic behavior. The purpose of this study is to investigate the bond characteristics at the interface between asphalt (HMA; hot-mixed asphalt) and the RCC base. METHODS : This study was performed to determine the optimal type and application rate of tack coat material for RCC-base composite pavement. In addition, the core size effect, temperature condition, and bonding failure shape were analyzed to investigate the bonding characteristics at the interface between the RCC base and HMA surface. To evaluate the bond strength, a pull-off test was performed using different diameters of specimens such as 50 mm and 100 mm. Tack coat materials such as RSC-4 and BD-Coat were applied in amounts of 0.3, 0.5, 0.7, 0.9, and $1.1l/m^2$ to determine the optimal application rate. In order to evaluate the bond strength characteristics with temperature changes, a pull-off test was carried out at -15, 0, 20, and $40^{\circ}C$. In addition, the bond failure shapes were analyzed using an image analysis program after the pull-off tests were completed. RESULTS : The test results indicated that the optimal application rate of RSC-4 and BD-Coat were $0.8l/m^2$, $0.9l/m^2$, respectively. The core size effect was determined to be negligible because the bond strengths were similar in specimens with diameters of 50 mm and 100 mm. The bond strengths of RSC-4 and BD-Coat were found to decrease significantly when the temperature increased. As a result of the bonding failure shape in low-temperature conditions such as -15, 0, and $20^{\circ}C$, it was found that most of the debonding occurred at the interface between the tack coat and RCC surface. On the other hand, the interface between the HMA and tack coat was weaker than that between the tack coat and RCC at a high temperature of $40^{\circ}C$. CONCLUSIONS : This study suggested an optimal application rate of tack coat materials to apply to RCC-base composite pavement. The bond strengths at high temperatures were significantly lower than the required bond (tensile) strength of 0.4 MPa. It was known that the temperature was a critical factor affecting the bond strength at the interface of the RCC-base composite pavement.

탄소섬유쉬트 올방향에 따른 콘크리트 기둥 보강성능 (The Strengthening Effects of Concrete Columns Confined with Carbon Fiber Sheets along the Fiber Direction)

  • 김양중;홍갑표
    • 한국건축시공학회지
    • /
    • 제11권4호
    • /
    • pp.326-332
    • /
    • 2011
  • 구조물의 내력증진 방법으로 적용되는 섬유재료에는 탄소섬유와 아라미드섬유 브론섬유 및 유리섬유 등이 있다. 이 중에서도 탄소섬유는 가장 많이 쓰이는 재료로서 다른 종류의 섬유올이 2방향성인 반면 탄소섬유 올은 1방향성으로서 부착되는 섬유올 방향으로만 인장내력에 의해 보강되므로 현장적용 시 섬유올의 부착방향이 매우 중요한 요소이나 보강설계 시 이에 대한 뚜렷한 도시가 되지 않아 구조적 지식이 없는 현장기술자 또는 인부들의 무개념적인 시공으로 보강성능을 전연 확보하지 못하는 사례가 종종 발생되곤 한다. 본 연구는 콘크리트 기둥에 대한 탄소섬유쉬트 방향에 따른 보강성능을 파악코자 각 실험체별로 섬유 올의 경사, 수평 및 수직방향으로 보강한 후 가력을 통한 보강성능을 비교 분석하여 섬유올 방향이 보강성능에 미치는 영향을 대비분석함으로서 섬유방향에 대한 최적의 보강설계 방안을 제시하고자 하였으며, 실험결과 수평방향의 보강성능은 153.43%인 반면 수직보강은 겨우 104.61%로서 거의 보강효과가 없는 것으로 나타났다. 이는 섬유올 방향의 인장내력 증진에 따른 구속효과에 의한 보강효과로서 보강설계와 현장관리에 철저한 관리가 절대적이다.

에너지 효율적인 데이터 수집을 이용한 LEACH 기반 무전 센서 네트워크의 수명 연장 (Prolonging Lifetime of the LEACH Based Wireless Sensor Network Using Energy Efficient Data Collection)

  • 박지원;모상만;정일용;배용근
    • 전자공학회논문지CI
    • /
    • 제45권3호
    • /
    • pp.175-183
    • /
    • 2008
  • 애드혹 네트워크의 실용 영역인 무선 센서 네트워크에서 센서 노드는 배터리에 의해 동작하고 일반적으로 한번 배치된 후 다시 회수 되지 않는다. 따라서 각각의 센서 노드는 한정된 에너지로 감지하고 통신해야 하며, 에너지 효율성은 무선 센서 네트워크의 수명을 결정하는 핵심 설계 요소로서 활발히 연구되고 있고 근래에는 크로스 레이어 최적화를 통해 더욱 개선되고 있다. 본 논문에서는 무선 센서 네트워크 시스템인 ZigbeX 플랫폼에서 센서 노드의 전송 출력 제어를 통하여 데이터 수집 과정에서 소모되는 에너지를 절약하는 새로운 기법을 제안하여 구현하고 실험 및 측정을 통하여 성능 개선 효과를 입증한다. 클러스터 멤버를 구성하는 각 센서 노드에서 클러스터 헤드로 데이터를 전송하는 과정에서 멤버 노드의 송신 출력을 통신 가능한 적정 수준으로 낮춤으로써 에너지를 절약하게 된다. 각 멤버 노드는 클러스터 헤드로부터 수신한 패킷의 RSSI(Received Signal Strength Indicator) 값을 기반으로 하여 자신의 송신 출력을 조절한다. 즉 자신이 전송한 패킷을 클러스터 헤드가 안전하게 수신할 수 있는 적정 수준으로 출력을 낮춤으로써 에너지를 절약하게 된다. ZigbeX 플랫폼 상에서 구현한 프로토콜을 자체 개발한 패킷 분석기를 이용하여 반복 측정한 결과에 의하면, 제안한 출력 제어 기법을 사용함으로써 통신량의 대부분을 차지하는 데이터 수집 과정에서의 에너지가 절약되어 네트워크 수명이 최대 21.9% 증가됨을 확인할 수 있었다.

20년 이상 경과된 노후건축물의 단열재 성능평가에 관한 실험적 연구 (An Experimental Study on a Performance Evaluation of Internal Insulation of Buildings Over 20 Years Old)

  • 김현진;최세진
    • 한국건축시공학회지
    • /
    • 제19권6호
    • /
    • pp.539-547
    • /
    • 2019
  • 최근 국제사회는 지구온난화 방지를 위한 기후변화협약을 체결하고 건축물의 냉방 및 난방 에너지로 공급하는 화석연료 사용을 줄이고자 신축 또는 기존건물에 대한 녹색건축인증(G-SEED) 및 에너지효율등급, 건축물 에너지절약 설계기준 등을 일정조건 이상인 건축물에 의무적으로 적용하고 있다. 건물에 공급하는 에너지 공급을 줄이고 보온성을 향상시키는 건축자재로 단열재가 사용되고 있으며 신축건축물의 에너지절약 설계기준을 만족하는 건물외피 구성 재료 중 총 열 저항성의 90% 이상을 차지하고 있다. 그러나 기존건축물에 시공된 단열재의 경시변화에 대한 명확한 자료가 부족하여 건축물의 에너지성능 판단기준인 단위면적당 1차에너지 소요량 산정에 대한 의문점을 갖게 되었다, 이에 20년 이상 된 노후 건축물의 리모델링 현장에서 단열재(압출법,비드법)를 직접 채취하여 단열재성능을 비교·평가하였다. 실험결과, 압출법(XPS)은 생산초기 품질기준인 KS M 3808보다 열전도율은 48%, 압축강도는 36%가 저하되어 본래의 성능을 발휘하지 못함을 알 수 있었고, 비드법(EPS)의 경우 단열재 두께가 50mm인 경우 열전도율과 압축강도, 굴곡파괴하중 등이 생산초기 품질기준을 유지함을 알 수 있었다. 따라서 비드법의 경우 단열재 두께를 고려하여 현재의 단위면적당 1차 에너지소 요량을 기존대로 산정하고, 압출법의 경우는 단위면적당 1차 에너지소요량 산정시 보정계수를 적용해야 할 것으로 판단된다.

부재 및 고장력볼트 구멍치수에 따른 미끄러짐계수의 실험적 연구 (Experimental Study on the Slip Coefficient with Member Type and Dimensions of High Tension Bolt Hole)

  • 양승현
    • 한국산학기술학회논문지
    • /
    • 제13권9호
    • /
    • pp.4277-4283
    • /
    • 2012
  • 고장력볼트 마찰이음에서 접촉면의 표면상태에 따라 다양한 값을 갖는 미끄러짐계수는 볼트의 축력과 미끄러짐하중에 의해 결정되어진다. 또한 접촉면적은 미끄러짐하중에 영향을 미치게 되므로 볼트구멍에 따라 변하는 접촉면적은 미끄러짐계수와 상관관계를 갖게 된다. 본 연구에서는 부재의 종류, 볼트의 직경 및 볼트구멍의 크기에 따른 미끄러짐계수와 미끄러짐하중의 변화를 파악하기 위하여 32개의 시험편을 제작하여 휨시험 및 인장시험을 실시하였다. 과대볼트구멍으로 제작된 시험편의 미끄러짐하중은 표준볼트구멍으로 제작된 미끄러짐하중의 80%이상의 강도를 발휘하였으며 설계 미끄러짐강도를 상회하였다. 또한 과대볼트구멍으로 제작된 시험편과 표준볼트구멍으로 제작된 시험편의 순단면적비와 미끄러짐비간에는 상당한 상관성을 가지는 것으로 나타났다. 그러나 시험결과가 각 시험체에 따라 다소의 차이를 보이는 것은 미끄러짐계수의 중요한 파라메타인 고장력볼트의 도입축력이 감소하기 때문인 것으로 판단된다. 볼트구멍 크기의 증가는 미끄러짐 계수 뿐 아니라 볼트 축력의 감소를 야기시키므로 설계강도의 감소를 초래하는 것은 자명한 사실이지만 외국의 경우와 같이 구조적 안정을 위협하지 않는 범위 내에서 볼트구멍에 대한 규정에 유연성을 갖는 것도 시공성과 효율성에 긍정적인 요소가 될 것으로 기대된다.

G/T 250톤 양방향 차도선 축계의 동특성에 관한 고찰 (A Study on Shaft Dynamic Characteristic for G/T 250TON Double-Ended Car-Ferry)

  • 강병모;오영철;배동균;서광철;고재용
    • 해양환경안전학회지
    • /
    • 제21권1호
    • /
    • pp.83-90
    • /
    • 2015
  • 육지와 도서를 연결하는 차도선은 교통수단 기능과 물자수송을 담당하는 중요한 역할을 하고 있다. 이에 따라 차도선의 효율성 증대와 안전성 향상 및 경제적 요건 등을 고려한 선박이 개발 중이다. 유럽에서는 승객의 편의성 및 경제성을 고려하여 양방향 차도선(Double-ended Car Ferry)의 개발이 활발히 진행 중이며 국내에서도 이에 대한 연구 개발이 필요하다. 본 연구에서는 유한요소법을 이용하여 차도선 제작 시 축계의 제작 및 강도의 문제를 Campbell Diagram 및 Modal 해석을 통한 동특성 분석을 하였다. 이를 통하여 양방향 차도선의 추진 방향 및 후진 방향 축계 작동 시 공진 현상 및 위험속도를 분석 결과 안정성을 보인 것으로 판단된다.