• 제목/요약/키워드: strength decay

검색결과 107건 처리시간 0.022초

A complement to Hoek-Brown failure criterion for strength prediction in anisotropic rock

  • Bagheripour, Mohammad Hossein;Rahgozar, Reza;Pashnesaz, Hassan;Malekinejad, Mohsen
    • Geomechanics and Engineering
    • /
    • 제3권1호
    • /
    • pp.61-81
    • /
    • 2011
  • In this paper, a complement to the Hoek-Brown criterion is proposed in order to derive the strength of anisotropic rock from strength of the corresponding truly intact rock. The complement is a decay function, which unlike other modifications or suggestions made in the past, is multiplied to the function of the original Hoek-Brown failure criterion for intact rock. This results in a combined and extended form of the criterion which describes the strength of anisotropic rock as a varying fraction of the corresponding truly intact rock strength. Statistical procedures and in particular regression analyses were conducted into data obtained in experiments conducted in the current research program and those collected from the literature in order to define the Hoek-Brown's criterion complement. The complement function was best described by a simple polynomial including only three constants to be empirically evaluated. Further investigations also showed that these constants can be related to the other readily available parameters of rock material which further facilitate determining the constants. A great and prime advantage of the proposed complement is that it is mathematically simple including the least possible number of empirical constants which are easily estimated with minimum experimental effort. Moreover, proposed concept does not suggests any change to the original Hoek-Brown criterion itself or its constants and serves whenever anisotropy does exist in the rock. This further implies on the possibility of using any other failure criterion for intact rock in conjunction with the compliment to reach the strength of anisotropic rock.

Estimation of NO$_2$ Source Generation and Ventilation rate in Residence by Multiple Measurements

  • Won Ho, Yang;Gi Yeong, Lee
    • 한국환경과학회:학술대회논문집
    • /
    • 한국환경과학회 2003년도 봄 학술발표회 발표논문집
    • /
    • pp.155-160
    • /
    • 2003
  • Indoor air quality can be affected by indoor sources, ventilation, decay and outdoor levels. Although technologies exist to measure these factors, direct measurements are often difficult. The purpose of this study was to develop an alternative method to characterize indoor environmental factors by multiple indoor and outdoor measurements. Daily indoor and outdoor $NO_2$ concentrations were measured for 30 consecutive days in 28 houses in Brisbane, Australia, and for 21 consecutive days in 37 houses in Seoul, Korea. Using a mass balance model and regression analysis, penetration factor (ventilation rate divided by the sum of ventilation rate and deposition constant) and source strength factor (source strength divided by the sum of ventilation rate and deposition constant) were calculated using multiple indoor and outdoor measurements. Subsequently, the ventilation rate and $NO_2$ source strength were estimated. Geometric means of ventilation rate were 1.44 ACH in Brisbane, assuming a residential $NO_2$ deposition constant of 1.05 $hr^{-1}$, and 1.36 ACH in Seoul, with the measured residential $NO_2$ deposition constant of 0.94 $hr^{-1}$. Source strengths of $NO_2$ were 15.8 $\pm$ 18.2 ${\mu}g$/$m^3$.hr and 44.7 $\pm$ 38.1${\mu}g$/$m^3$.hr in Brisbane and Seoul, respectively. In conclusion, indoor environmental factors were effectively characterized by this method using multiple indoor and outdoor measurements.

  • PDF

Estimation of Nitrogen Dioxide Source Generation and Ventilation Rate in Residence Using Multiple Measurements in Korea

  • Chung, Moon-Ho;Yang, Won-Ho
    • 한국환경보건학회:학술대회논문집
    • /
    • 한국환경보건학회 2004년도 International Conference Current Challenges and Advances in Environmental Health
    • /
    • pp.45-50
    • /
    • 2004
  • Indoor air quality can be affected by indoor sources, ventilation, decay and outdoor levels. Alt hough technologies exist to measure these factors, direct measurements are often difficult. The purpose of this study was to develop an alternative method to characterize indoor environmental factors by multiple indoor and outdoor measurements. Daily indoor and outdoor NO2 concentrations were measured for 30 consecutive days in 28 houses in Brisbane, Australia, and for 21 consecutive days in 37 houses in Seoul, Korea. Using a mass balance model and regression analysis, penetration factor (ventilation rate divided by the sum of ventilation rate and deposition constant) and source strength factor (source strength divided by the sum of ventilation rate and deposition constant) were calculated using multiple indoor and outdoor measurements. Subsequently, the ventilation rate and NO2 source strength were estimated. Geometric means of ventilation rate were 1.44 ACH in Brisbane, assuming a residential NO2 deposition constant of 1.05 hr-1, and 1.36 ACH in Seoul, with the measured residential NO2 deposition constant of 0.94 hr-1. Source strengths of N02 were 15.8 ${\pm}$ 18.2 ${\mu}$g/m3${\cdot}$hr and 44.7 ${\pm}$ 38.1 ${\mu}$g/m3${\cdot}$hr in Brisbane and Seoul, respectively. In conclusion, indoor environmental factors were effectively characterized by this method using multiple indoor and outdoor measurements.

  • PDF

Seismic detailing of reinforced concrete beam-column connections

  • Kim, Jang Hoon;Mander, John B.
    • Structural Engineering and Mechanics
    • /
    • 제10권6호
    • /
    • pp.589-601
    • /
    • 2000
  • A simplified analysis procedure utilizing the strut-tie modeling technique is developed to take a close look into the post-elastic deformation capacity of beam-column connections in ductile reinforced concrete frame structures. Particular emphasis is given to the effect of concrete strength decay and quantity and arrangement of joint shear steel. For this a fan-shaped crack pattern is postulated through the joints. A series of hypothetical rigid nodes are assumed through which struts, ties and boundaries are connected to each other. The equilibrium consideration enables all forces in struts, ties and boundaries to be related through the nodes. The boundary condition surrounding the joints is obtained by the mechanism analysis of the frame structures. In order to avoid a complexity from the indeterminacy of the truss model, it is assumed that all shear steel yielded. It is noted from the previous research that the capacity of struts is limited by the principal tensile strain of the joint panel for which the strain of the transverse diagonal is taken. The post-yield deformation of joint steel is taken to be the only source of the joint shear deformation beyond the elastic range. Both deformations are related by the energy consideration. The analysis is then performed by iteration for a given shear strain. The analysis results indicate that concentrating most of the joint steel near the center of the joint along with higher strength concrete may enhance the post-elastic joint performance.

방염 처리 고목재의 미생물 분해의 미시형태적 특징 (Micromorphological Characteristics of Buddhist Temple Woods Treated with Eire-retardant)

  • 위승곤;김익주;박영만;김윤수
    • 한국문화재보존과학회:학술대회논문집
    • /
    • 한국문화재보존과학회 2001년도 제14회 발표논문집
    • /
    • pp.27-34
    • /
    • 2001
  • 화재를 예방하고자 방염 처리 한 일부 고건축재에서 발견된 미생물에 의한 고목재의 분해를 전자현미경을 사용하여 관찰하였다. 방염 처리한 고건축 부재는 2차벽 중층에 마이크로배열 방향과 동일한 동공을 가지고 있는 전형적인 연부후를 보였다. 또한 주사형 및 투과형 전자현미경을 사용하여 관찰한 결과 일부 세포벽은 세균에 의해 분해된 것으로 나타났다. 방염 처리한 고건축재에서 나타난 이같은 부후형태는 수분으로 포화된 수침 고목재에서 나타나는 전형적인 부후 형태이다. 부후 형태로부터 본 연구에 사용된 고건축 부재는 방염 처리 후 흡수성이 급격히 증가하였으며, 이같은 함수율의 증가는 사용된 방염제 때문인 것으로 생각된다. 본 연구 결과 사찰 및 궁질 등 고건축물에 사용하고 있는 방염제에 대한 보다 더 체계적이고 심도있는 연구가 필요함을 보여주었으며 아울러 방염제가 목재의 흡수성과 강도에 미치는 영향에 대한 연구가 뒤따라야함을 제시하였다. 본 논문은 또한 기상 열화에 의한 일부 목재의 표층부에 나타난 중간층의 분해에 대해서도 논의하였다.

  • PDF

단판(單板)의 약제처리(藥劑處理)가 합판성질개선(合板性質改善)에 미치는 영향(影響) (The Effect of Pretreatment of Veneer on the Improvement of Plywood Quality)

  • 심종섭
    • Journal of the Korean Wood Science and Technology
    • /
    • 제10권3호
    • /
    • pp.152-164
    • /
    • 1982
  • 1. In order to make the improvement of plywood quality, this study has been made. The pretreatments applied to the veneers are as follows. a) The soaking treatment of the veneer in 30 percent methanol solution for 24 hours was applied to remove some resinous materials which may cause many stain discolouring on the face of finished plywood. b) The preservative treatment of the veneer in 2 percent malenit solution for 2 to 3 minutes was adopted to make resistance against decay and insect damages. c) The fire retardant treatment of the veneer in 40 percent ammonium phosphate solution for 2 hours was applied to give retardation effect against fire burning. 2. The results summarized in this study are as follows. a) One percent resinous materials was extracted, after the soaking of the veneers in 30 percent diluted methanol. b) No marks of the dirty stains of resinous materials on the face of the treated plywood was shown, although many quite dirty stains on the face of untreated plywood have contrary seen. c) However, the strip shear test strength of the treated plywood was not decreased. It means that there is no difference in the strength between the treated plywood and the untreated plywood. The strength values were 25.08 kg/$cm^2$ and 24.98 kg/$cm^2$, respectively. d) The strip shear test strength of plywood made of the treated veneers in 2 percent malenit solution was not decreased. e) The slight decrease of the strip shear test strength of the treated plywood made of the treated veneer in 40 percent ammonuim phosphate solution was shown. However, the remarkable difference of the fire retardation activities between the treated specimens and the untreated specimens has seen as in Table 10, that is, the fire proofed specimens had taken about 28 seconds to start to burn, while the untreated specimens had taken 15 seconds to reach to burning. This means that the fire retardation effect of the fire proofed plywood was greater than that of the unproofed plywood.

  • PDF

주택 실내.외 이산화질소 측정을 이용한 환기량 및 발생량 추정 (Estimation of Ventilation and Generation Rates Using Nitrogen Dioxide Measurements of Indoor and Outdoor in Houses)

  • 양원호;임성국;손부순
    • 한국환경과학회지
    • /
    • 제17권10호
    • /
    • pp.1069-1073
    • /
    • 2008
  • Indoor air quality can be affected by indoor sources, ventilation, decay and outdoor levels. Although technologies exist to measure these factors, direct measurements are often difficult. The purpose of this study was to develop an alternative method to characterize indoor environmental factors by multiple indoor and outdoor measurements. Using a mass balance model and regression analysis, penetration factor (ventilation rate divided by the sum of ventilation rate and deposition constant) and source strength factor (source strength divided by the sum of ventilation rate and deposition constant) were calculated using multiple indoor and outdoor measurements. Subsequently, the ventilation rate and $NO_2$ generation rate were estimated. Mean of ventilation rate was 1.41 ACH in houses, assuming a residential N02 deposition constant of 0.94 $hr^{-1}$. Mean generation rate of $NO_2$ was 16.5 ppbv/hr. According to house characterization, inside smoking and family number were higher $NO_2$ generation rates, and apartment was higher than single-family house. In conclusion, indoor environmental factors were effectively characterized by this method using multiple indoor and outdoor measurements.

기계화시공에 의한 보수재료의 현장품질관리확립을 위한 실험적 연구 (An Experimental Study for Establishment of On-Site Quality Control of Repair Material by the mechanized construction)

  • 조봉석;장재봉;김용로;강석표;홍성윤;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.160-163
    • /
    • 2004
  • In domestic, various repair materials and method systems to keep up with these reinforced concrete deteriorated due to salt damage, carbonation, chemical decay et. developed and applied. However, on-site quality control of various repair materials and method systems isn't achieved desirably because it is depend completely on a men of experience' opinions above all else regardless of various on-site environments. In this background, mock up test with due regard to real on-site environments was performed to secure fundamental data for establishment of desirable on-site quality control. Mock up test using repair mortar analyzed from angles of construction methods, mechanical spraying pressures, W/M. Construction methods were designed manpower method and spraying method, spraying pressures were designed 32, 42, 52 psi, W/M were designed 14.4, 15.4, $16.4\%$. And compressive strength, Chloride ion diffusion coefficient, bond strength, SEM. of mock up test specimens were evaluated. In conclusion, we confirmed excellency of mechanical spraying pressures, fined extremely excellency of condition of spraying pressure 42 ps, W/M $14.4\%$ within this study. therefore the results of this study will be useful to provide fundamental data for establishment of desirable on-site quality control.

  • PDF

폴리에스터 섬유의 저욕비염색공정에 있어서 직물특성과 균염성의 상관성 분석 (Correlation between Levelness and Fabric Characteristics for Low Liquor Ratio Dyeing Processes of Polyester Fibers)

  • 정종석;장경진;김태경;조성우;이용진;남창우
    • 한국염색가공학회지
    • /
    • 제21권1호
    • /
    • pp.59-66
    • /
    • 2009
  • The seven kinds of polyester fabrics having different fabric characteristics were investigated in terms of their dyeing levelness under various liquor ratios. The levelness was evaluated statistically from color strength obtained at different sections of each piece of dyed fabrics. The color strength data were analyzed using a exponential decay function of 3 parameters, $y=y_0+ae^{-bx}$. The b value of the function was used as a index of sensitiveness of dependence on liquor ratio of levelness. The index, b value, showed a linear proportional relationship to thickness of fabrics. Average unlevelness of dyeings exhibited a inverse proportional relationship to both weight and thickness of fabrics.

인도네시아산 미이용 수종의 목재성질(III) - Kebambang, Bawang-bawang 및 Garu buaya 목재의 기초성질 - (Studies on the Wood Properties of Lesser-Known Species Grown in Indonesia(III) - The Fundamental Wood Properties of Kebambang, Bawang-bawang and Garu buaya -)

  • 정성호;정두진;박병수;이도식;조성택
    • 한국가구학회지
    • /
    • 제11권1호
    • /
    • pp.13-23
    • /
    • 2000
  • This study was carried out to investigate the wood properties for development the proper uses of lesser-known tree species. The tested species are Kebambang(Pentace sp.), Bawang-bawang(Dysoxylum alliaceum Bl .), Garu buaya( Gonystylus brunescens A. Shaw)grown in Indonesia. fundamental wood properties such as anatomical, physical, mechanical and chemical properties and characteristics related to wood processing were examined. The results are summarized as follows : The woods of these species are diffuse porous, coarse textured, and interlocked grained. The heartwood of Kebambang is distinguished clearly to the sapwood, but the heartwood of other species are not distinguished clearly to the softwood. The woods of Kebambang and Bawang-bawang have the moderate weight density and the low strength properties, but Garu buaya has the high weight density and the high strength properties. The woods of these species has high shrinkage. The sawing characteristics of Kebambang are excellent but the other species are moderate. The machining characteristics by planer and drying characteristics of these species are moderate. These woods has poor characteristics in bending processing and decay durability. The wood of Bawang-bawang has high content of the extractives and lignin.

  • PDF