• Title/Summary/Keyword: strength control model

Search Result 381, Processing Time 0.031 seconds

Strength Properties of Wooden Model Erosion Control Dams Using Domestic Pinus rigida Miller I (국내산 리기다소나무를 이용한 목재 모형 사방댐의 강도 성능 평가 I)

  • Kim, Sang-Woo;Park, Jun-Chul;Lee, Dong-Heub;Son, Dong-Won;Hong, Soon-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • v.36 no.6
    • /
    • pp.77-87
    • /
    • 2008
  • Wooden model erosion control dam was made with pitch pine, of which the strength properties was evaluated. Wooden model erosion control dam was made with diameter 90 mm of pitch pine round posts treated with CUAZ-2 (Copper Azole), changing joint in three different types. In each type, erosion control dam was made in nine floor (cross-bar of five floors and vertical-bar of four floors), of which the hight was 790 mm. And then strength properties were investigated through horizontal loading test and impact strength test, and the deformation of structure through image processing (AICON 3D DPA-PRO system). In horizontal loading test of wooden model erosion control dam using round post of diameter 90 mm, whether there was stone or not did not affect strength much when using self drill screw, but strength was decreased by 23%. In monolithic type of erosion control dam using screw bar, strength was increased by 1.5 times and deformation was decreased when filling with stone. When reinforcing with screw bar that ring is connected to self drill screw, strength was increased by 4.8 times. In impact strength test of wooden model erosion control dam made with round post of diameter 90 mm, the erosion control dam connected with self drilling screw not filling with stone was totally destroyed by the 1st impact, and the erosion control dam using screw bar was ruptured at cross-bar at which 779 kgf of impact was loaded in the 1st impact. In the 2nd impact, the base parts were ruptured, and reaction force was decreased to 545 kgf. In the 3rd impact, whole base parts were destroyed, and reaction force was decreased to 263 kgf.

Development of Effective Stiffness and Effective Strength for a Truss-Wall Rectangular model combined with Micro-Lattice Truss (트러스 벽면과 미세격자 트러스로 구성된 정육면체 단위모델의 강성 및 강도 개발)

  • Choi, Jeong-Ho
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.19 no.3
    • /
    • pp.133-143
    • /
    • 2016
  • The objective in here is to find the density, stiffness, and strength of truss-wall rectangular (TWR) model which is combined with lattice truss (MLT) inside space. The TWR unit-cell model is defined as a unit cell originated from a solid-wall rectangular (SWR) model and it has an empty space inside. Thus, the empty space inside of the TWR is filled with lattice truss model defined as TWR-MLT. The ideal solutions derived of TWR-MLT are based on TWR with MLT model and it has developed by Gibson-Ashby's theory. To validate the ideal solutions of the TWR-MLT, ABAQUS software is applied to predict the density, strength, and stiffness, and then each of them are compared with the Gibson-Ashby's ideal solution as a log-log scale. Applied material property is stainless steel 304 because of cost effectiveness and easy to get around. For the analysis, SWR and TWR-MLT models are 1mm, 2mm, and 3mm truss diameter separately within a fixed 20mm opening width. In conclusion, the relative Young's modulus and relative yield strength of the TWR-MLT unit model is reasonably matched to the ideal expectations of the Gibson-Ashby's theory. In nearby future, TWR-MLT model can be verified by advanced technologies such as 3D printing skills.t.

Shear strength of full-scale steel fibre-reinforced concrete beams without stirrups

  • Spinella, Nino
    • Computers and Concrete
    • /
    • v.11 no.5
    • /
    • pp.365-382
    • /
    • 2013
  • Although shear reinforcement in beams typically consists of steel bars bent in the form of stirrups or hoops, the addition of deformed steel fibres to the concrete has been shown to enhance shear resistance and ductility in reinforced concrete beams. This paper presents a model that can be used to predict the shear strength of fibrous concrete rectangular members without stirrups. The model is an extension of the plasticity-based crack sliding model originally developed for plain concrete beams. The crack sliding model has been improved in order to take into account several aspects: the arch effect for deep beams, the post-cracking tensile strength of steel fibre reinforced concrete and its ability to control sliding along shear cracks, and the mitigation of the shear size effect due to presence of fibres. The results obtained by the model have been validated by a large set of experimental tests taken from literature, compared with several models proposed in literature, and numerical analyses are carried out showing the influence of fibres on the beam failure mode.

A Study of the impacts of control types on Tie strength and Project Performance - focus on field project organization of construction industry

  • Lee, Won-Hee;Cho, Ho-Haeng
    • Journal of the Korea Society of Computer and Information
    • /
    • v.26 no.7
    • /
    • pp.103-108
    • /
    • 2021
  • In this paper, we an empirical study of the effects of control types on Tie strength and filed project performance of project participants in field project organization for Korean domestic construction industry. In the study, we try to tell what significant impact output control, process control and tie strength among field project participants have on field project performance and features unique to field project organization for Korean construction industry through empirical analysis. And the findings of the empirical analysis are that output control appeared to have significant impacts on tie strength among the participants and process control, and process control also appear to have significant impact on field project performance.

Fuzzy logic model for the prediction of concrete compressive strength by incorporating green foundry sand

  • Rashid, Khuram;Rashid, Tabasam
    • Computers and Concrete
    • /
    • v.19 no.6
    • /
    • pp.617-623
    • /
    • 2017
  • This work is conducted with the aim of using waste material to reserve the natural resources. The objective is accomplished by conducting experimentation and verify by modeling based on fuzzy logic. In experimentation, concrete is casted by using natural/river sand as fine aggregate and termed as control specimen. Natural sand is conserved by replacing it with used foundry sand (UFS) by an amount of 10, 20 and 30% by weight. Fresh and hardened properties of concrete are investigated at different ages. It is observed that compressive strength and modulus of elasticity reduced with the increase in amount of UFS. Furthermore, concrete compressive strength is predicted by using fuzzy logic model and verified at different replacement ratio and age with experimental observations.

Structural Design of a Front Lower Control Arm Considering Durability (내구성을 고려한 하부 컨트롤 암의 구조설계)

  • Park, Han-Seok;Kim, Jong-Kyu;Seo, Sun-Min;Lee, Kwon-Hee;Park, Young-Chul
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.8 no.4
    • /
    • pp.69-75
    • /
    • 2009
  • Recently developed automotive components are getting lighter providing a higher fuel efficiency and performance. Following the current trend, this study proposes a structural optimization method for the lower control arm installed at the front side of a Vehicle. Lightweight design of lower control arm can be achieved through design and material technology. In this research, the shape of lower control arm was determined by applying the optimization technology and aluminum was selected as a steel-substitute material. Strength performance is the most important design requirement in the structural design of a control arm. This study considers the static strength in the optimization process. For the optimum design, the durability analysis is performed to predict its fatigue life. In this study, the kriging interpolation method is adopted to obtain the minimum weight satisfying the strength constraint. Optimum designs are obtained by the in-house program, EXCEL-Kriging. Also, based on the optimum model obtained for the static strength, the optimization of Index of Fatigue Durability is carried out to get th optimum fatigue performance.

  • PDF

Indoor Positioning Using WLAN Signal Strength (무선랜의 신호세기를 이용한 실내 측위)

  • Kim, Suk-Ja;Lee, Jin-Hyun;Jee, Gyu-In;Lee, Jang-Gyu;Kim, Wuk
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.10 no.8
    • /
    • pp.742-747
    • /
    • 2004
  • Outdoors we can easily acquire our accurate location by GPS. However, the GPS signal can't be acquired indoors because of its weak signal power level. Adequate positioning method is demanded for many indoor positioning applications. At present, wireless local area network (WLAN) is widely installed in various areas such as airport, campus, and park. This paper proposes a positioning algorithm using WLAN signal strength to provide the position of the WLAN user indoors. There are two methods for WLAN based positioning, the signal propagation method uses signal strength model over space and the empirical method uses RF power propagation database. The proposed method uses the probability distribution of the power propagation and the maximum likelihood estimation (MLE) algorithm based on power strength DB. Test results show that the proposed method can provide reasonably accurate position information.

Assessment of compressive strength of cement mortar with glass powder from the early strength

  • Wang, Chien-Chih;Ho, Chun-Ling;Wang, Her-Yung;Tang, Chi
    • Computers and Concrete
    • /
    • v.24 no.2
    • /
    • pp.151-158
    • /
    • 2019
  • The sustainable development principle of replacing natural resources with renewable material is an important research topic. In this study, waste LCD (liquid crystal display) glass powder was used to replace cement (0%, 10%, 20% and 30%) through a volumetric method using three water-binder ratios (0.47, 0.59, and 0.71) to make cement mortar. The compressive strength was tested at the ages of 7, 28, 56 and 91 days. The test results show that the compressive strength increases with age but decreases as the water-binder ratio increases. The compressive strength slightly decreases with an increase in the replacement of LCD glass powder at a curing age of 7 days. However, at a curing age of 91 days, the compressive strength is slightly greater than that for the control group (glass powder is 0%). When the water-binder ratios are 0.47, 0.59 and 0.71, the compressive strength of the various replacements increases by 1.38-1.61 times, 1.56-1.80 times and 1.45-2.20 times, respectively, during the aging process from day 7 to day 91. Furthermore, a prediction model of the compressive strength of a cement mortar with waste LCD glass powder was deduced in this study. According to the comparison between the prediction analysis values and test results, the MAPE (mean absolute percentage error) values of the compressive strength are between 2.79% and 5.29%, and less than 10%. Thus, the analytical model established in this study has a good forecasting accuracy. Therefore, the proposed model can be used as a reliable tool for assessing the design strength of cement mortar from early age test results.

Interactive strut-and-tie-model for shear strength prediction of RC pile caps

  • Chetchotisak, Panatchai;Yindeesuk, Sukit;Teerawong, Jaruek
    • Computers and Concrete
    • /
    • v.20 no.3
    • /
    • pp.329-338
    • /
    • 2017
  • A new simple and practical strut-and-tie model (STM) for predicting the shear strength of RC pile caps is proposed in this paper. Two approaches are adopted to take into account the concrete softening effect. In the first approach, a concrete efficiency factor based on compression field theory is employed to determine the effective strength of a concrete strut, assumed to control the shear strength of the whole member. The second adopted Kupfer and Gerstle's biaxial failure criterion of concrete to derive the simple nominal shear strength of pile caps containing the interaction between strut and tie capacity. The validation of these two methods is investigated using 110 RC pile cap test results and other STMs available in the literature. It was found that the failure criterion approach appears to provide more accurate and consistent predictions, and hence is chosen to be the proposed STM. Finally, the predictions of the proposed STM are also compared with those obtained by using seven other STMs from codes of practice and the literature, and were found to give better accuracy and consistency.

A decentralized adaptive model following control scheme for a class of interconnected continuous system (일련의 상호연결된 연속시간 시스템의 비집중 적응 모델 추종 제어 방식)

  • Kim, Byung-Yeun;Lyou, Joon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10a
    • /
    • pp.1068-1072
    • /
    • 1991
  • This paper presents a decentralized model reference adaptive control scheme for an interconnected continuous linear system composed of a number of single-input single-output subsystems in which outgoing interactions pass through the measurement channel and are subject to bounded external disturbance. The scheme can treat the unknown strength of interactions as well as the uncertainty of subsystems.

  • PDF