The Transactions of the Korean Institute of Electrical Engineers C
/
v.52
no.2
/
pp.91-97
/
2003
In addition to its strong oxidizing power, the ozone has definite advantages over other commercial oxidants, namely, no undesirable by- products or residues are formed. With growing interest in the improvement of the ozone production in the industrial fields, many types of ozonizer using the electrical discharges have been proposed for the higher efficiency and the higher Performance at atmospheric Pressure. Among them, a superposition of different type discharges has been proposed. Especially, since the improvement for the low efficiency of dc discharge and narrow gap of surface discharge is required, a do and an at voltage are applied to same reaction space (or volume) to increase energy density at the same space. An investigation was focused on the superposition with a dc (streamer) corona and 3 surface discharge. This paper describes the investigation results on fundamental ozone generation characteristics by this superimposed discharge.
This paper presents the prediction method of small current interruption Performance for EHV gas circuit breakers. The FVFLIC method is used for the gas flow analysis and the FEM for the electric field analysis. Then, the dielectric withstanding voltage is evaluated by the empirical formulation or Streamer theory. By comparing the calculated dielectric strength with the test result. it is found that both methods show good prediction capability for the small current interruption performance. Especially, when both methods predict the same interrupting performance, the prediction is in accordance with the experimental result.
Tests of pilot-scale plasma DeSOx-DeNOx system using pulsed streamer corona were carried out. The system consists of the reactor with wire-plate electrodes the $30kW_{max}$. MPC type pulse generator, and $1MW_{th}$ pulverized coal combustor as a flue gas source. $NH_3$ and $C_2H_4$ were used to enhance the removal rate. The experimental result on the removal efficiency of SOx/NOx and on the effect of the additives was presented in this paper.
Interaction between flames and non-thermal plasmas of DBD type has been experimentally investigated. Vigorous streamers were observed under flame conditions because of the increase of reduced field (electrical) at high temperature as well as the seeding of free electrons and ions generated inside the flame. Flame lengths were significantly shortened as the applied voltage increased on account of intense mixing by ionic winds and soot-induced flows. Flame luminosities severely decreased under plasma conditions, which means the reduction of soot, since the residence time was reduced because of the flame shortening. Temperature and major species concentrations measured by FTIR were not changed despite the plasma generation. which shows overall chemistries were not affected by non-thermal plasmas.
The reduction in the breakdown field strength due to electrode surface roughness was calculated by applying the streamer breakdown criterion and the surface roughness factor, and measurements of static breakdown voltage for a gap with an artificial protrusion were made under the uniform field at pressures up to 4 bar in pressurized $SF_{6}$. The effect of polarity of highly stressed electrode on the breakdown field strength was also investigated. The measurements have shown that the measured breakdown levels for a protrusion located on the cathode agree with those calculated and the values measured with an identical anode protrusion are substantially higher and more scattered. This may be explained if it assumed that a high rate of production of initiatory electrons is maintained at the tip of a cathode protrusion by field emission. In practical point of view, the breakdown levels in pressurized $SF_{6}$ can be bereliably estimated from the values calculated.
The Transactions of the Korean Institute of Electrical Engineers
/
v.36
no.9
/
pp.651-654
/
1987
There are a number of small scale application fields of ozone, such as food conservation and/or storage in refrigerators, containers and storage rooms, deodorization in the production and living areas, protection against biohazards, bleaching of fabrics, etc. For these applications, miniaturization, ozone controllability and costdown of the ozonizer are the most essential points, whereas power efficiency is the most imporant factor in the case of a large scale ozonizer used in various industrial applications. It has been developed a novel sawtooth-to-cylinder type micro-ozonizer meeting above the three points by using a negative pulse corona discharge. As a result of the observations of pulse coronas affecting ozone generation, it is found that the maximum ozone concentration is generated at the pulse streamer coronas in both positive and negative case. The ozone concentration (20ppm/2l/min) generated by the negative pulse corona is about 2 times higher than that of the positive pulse corona, and could be controllable linearly by adjusting the dc input voltage of the [supply-inth ] cinventional small scale ozonizers. As a result, the present ozonizer is also very good to be used as a micro-ozonizer.
Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
/
1989.06a
/
pp.40-42
/
1989
In this paper, the theoritical breakdown characteristics of $N_2$and $SF_{6}$ in uniform field are studied by streamer criterion and the effective ionisation coefficients. Evaluation of the breakdown voltage for $N_2$and $SF_{6}$ has been done over following ranges: $N_2$: 100.0 $\leq$pd$\leq$10000.0(Torr cm) $SF_{6}$: 100.0$\leq$pd$\leq$6000.0(Torr cm) Computed values are compared with those of experiment. The results show a good agreement between the computed and the experimental values.
In removing the flue-gas using electrical discharge method, it is important to dissociate or ionize the atoms and molecules by the collisions with energetic electrons and it produces the radicals that are used to decompose the pollutants. For that purpose, a bidirectional pulsed voltage is used to produce lots of energetic electrons efficiently and increase the power efficiency. The simulation is performed with changing the pulsewidth under the fixed applied voltage. The particle-mesh model coupling the NGP(nearest-grid-point) to FEM(finite element method) is used to simulate the behavior of electrons and the spatio-temporal variation of the electric field for the streamer in discharge tube.
Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
/
2004.11a
/
pp.648-652
/
2004
A comparative investigation of an experimental and a simulation of chemical kinetics for NOx removal from dielectric barrier discharges is presented. Several types of dielectric barrier discharges were implemented depending upon the configuration of electrodes. The simulation was based on an approximate mathematical model for plasma cleaning of waste gas. The influence of non uniform distributions of species due to the production of primary active particles in the streamer channel was taken into account. A comparison of observed experimental to the calculated removal efficiency of NOx showed acceptable agreement.
Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
/
2000.05b
/
pp.207-211
/
2000
Deep Interests have been paid on the application of non-thermal plasma technique to solve the environmental pollution problems. $CO_2$ is one of the severe pollutants which cause the acid rain and global warming. In this study, in order to improve the conversion efficiency of $CO_2$, the streamer corona discharge plasma and barrier discharge plasma reactors were made, and the conversion characteristics of $CO_2$ by the corona discharge plasma and some discharge characteristics of these discharge chambers are studied experimentally.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.