• Title/Summary/Keyword: story model

Search Result 803, Processing Time 0.027 seconds

Elasto-plastic Earthquake Response Analysis of Beam-Shear Wall Structural System (보-전단벽식 구조 시스템의 탄소성 지진응답 해석)

  • 정명채;이정원
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.1 no.1
    • /
    • pp.57-67
    • /
    • 1997
  • The objective of present paper is to investigate elasto-plastic behaviour and estimate the resistance capacity of a beam-shear wall structural system against earthquake ground accleration exciations. Pushover analysis is adopted to estimate inttiate and post stiffnesses and yielding point for inelastic response analysis in LPM (Lumped Parameter Mass) model, and modified Clough model is used as the hysteresis rule of each story. Three earthquake waves are used in the analysis but their peak ground accelerations are changed to be 0.12g, 0.24g. It is assumed that the earthquakes act in the longigtudianl direction of a 25 Story apartment building which consists of two some unit plan. The distribution of story ratio and ductility ratio are estimated and discussed within Korean, Japanese code and UBC.

  • PDF

Three Dimensional Responses of Middle Rise Steel Building under Blast Loads (폭발하중을 받는 강구조 중층 건물의 응답 및 해석)

  • Hwang, Young-Seo;Lee, Wan-Soo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.6
    • /
    • pp.629-636
    • /
    • 2011
  • It has been suggested that buildings designed for strong ground motions will also have improved resistance to air blast loads. As an initial attempt to quantify this behavior, the responses of a ten story steel building, designed for the 1994 building code, with lateral resistance provided by perimeter moment frames, is considered. An analytical model of the building is developed and the magnitude and distribution of blast loads on the structure are estimated using available computer software that is based on empirical methods. To obtain the relationship between pressure, time duration, and standoff distance, these programs are used to obtain an accurate model of the air blast loading. A hemispherical surface burst for various explosive weights and standoff distances is considered for generating the air blast loading and determining the structural response. Linear and nonlinear analyses are conducted for these loadings. Air blast demands on the structure are compared to current seismic guidelines. These studies present the displacement responses, story drifts, demand/capacity ratio and inelastic demands for this structure.

Seismic Performance Evaluation of 3 Story OMRCF Based on Scaled Model Testing (축소모델실험에 의한 철근콘크리트 3층 보통모멘트골조의 구조 성능 평가)

  • Han Sang-Whan;Kwon Gun-Up
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.5 s.89
    • /
    • pp.673-678
    • /
    • 2005
  • ACI 318 (1999) defines three types of moment frames: Ordinary Moment Resisting Concrete Frame (OMRCF), Intermediate Moment Resisting Concrete Frame (IMRCF), and Special Moment Resisting Concrete Frame (SMRCF). OMRCF is the most popular type of moment frame in mild seismic zones that requires the least detail and design requirements. This study focuses on the seismic performance of Ordinary Moment Resisting Concrete Frames (OMRCF) designed only for gravity loads. For this purpose a 3-story OMRCF was designed in compliance with the minimum design requirements in ACI 318 (1999). An one third 3 story specimen was made and tested. For scaled model, the similitude law of true replica was applied. The specimen was loaded with quasi-static reversed cyclic lateral loading. The overall behavior of OMRCF is quite stable without abrupt strength degradation. It is found that tested frame has the base shear strength larger than the design base shear for seismic zone 1, 2A and 2B calculated using UBC 1997.

Influence of bi-directional seismic pounding on the inelastic demand distribution of three adjacent multi-storey R/C buildings

  • Skrekas, Paschalis;Sextos, Anastasios;Giaralis, Agathoklis
    • Earthquakes and Structures
    • /
    • v.6 no.1
    • /
    • pp.71-87
    • /
    • 2014
  • Interaction between closely-spaced buildings subject to earthquake induced strong ground motions, termed in the literature as "seismic pounding", occurs commonly during major seismic events in contemporary congested urban environments. Seismic pounding is not taken into account by current codes of practice and is rarely considered in practice at the design stage of new buildings constructed "in contact" with existing ones. Thus far, limited research work has been devoted to quantify the influence of slab-to-slab pounding on the inelastic seismic demands at critical locations of structural members in adjacent structures that are not aligned in series. In this respect, this paper considers a typical case study of a "new" reinforced concrete (R/C) EC8-compliant, torsionally sensitive, 7-story corner building constructed within a block, in bi-lateral contact with two existing R/C 5-story structures with same height floors. A non-linear local plasticity numerical model is developed and a series of non-linear time-history analyses is undertaken considering the corner building "in isolation" from the existing ones (no-pounding case), and in combination with the existing ones (pounding case). Numerical results are reported in terms of averages of ratios of peak inelastic rotation demands at all structural elements (beams, columns, shear walls) at each storey. It is shown that seismic pounding reduces on average the inelastic demands of the structural members at the lower floors of the 7-story building. However, the discrepancy in structural response of the entire block due to torsion-induced, bi-directionally seismic pounding is substantial as a result of the complex nonlinear dynamics of the coupled building block system.

Dynamic responses on traditional Chinese timber multi-story building with high platform base under earthquake excitations

  • Zhang, Xicheng;Ma, Hui;Zhao, Yanli;Zhao, Hongtie
    • Earthquakes and Structures
    • /
    • v.19 no.5
    • /
    • pp.331-345
    • /
    • 2020
  • The multi-story timber structure with high platform base is one of the important architectural types in the traditional Chinese buildings. To study the dynamic characteristics and seismic responses on this kind of traditional structure, the 3-D finite element models of Xi'an drum tower which included the high platform base, upper timber structure and whole structure was established considering the structural form and material performance parameters of the structure in this study. By the modal analysis, the main frequencies and mode shapes of this kind of traditional building were obtained and investigated. The three kinds of earthquake excitations included El-Centro wave, Taft wave and Lanzhou wave were separately imposed on the upper timber structure model and the overall structure model, and the seismic responses on the tops of columns were analyzed. The results of time history analysis show that the seismic response of the upper timber structure is obviously amplified by high platform base. After considering the effect of high platform base, the mean value on the lateral displacement increments of the top column in the overall structure is more than 20.478% and the increase of dynamic coefficients was all above 0.818 under the above three different earthquake excitations. Obviously, it shows that the existence of high platform base has a negative influence on the seismic responses of upper timber structure. And the high platform base will directly affect the safety of the upper timber structure. Therefore, the influence of high platform base on the dynamic response of its upper timber structure cannot be neglected.

The Analysis of Successional Trends by Community Types in the Natural Deciduous Forest of Mt. Jumbong (점봉산 일대 천연활엽수림의 군집 유형별 천이 경향 분석)

  • Jin, Guang Ze;Kim, Ji Hong
    • Journal of Korean Society of Forest Science
    • /
    • v.94 no.6
    • /
    • pp.387-396
    • /
    • 2005
  • Having employed the transitional probability model based on Markov chain, the study was carried out to examine successional trends for community types in the natural deciduous forest of Mt. Jumbong. The species composition of oncoming generation in overstory was estimated from that of mid-story, and the species composition in mid-story was based upon that of understory. Successional trend for each community was predicted from the reorganized probability matrix of tree replacement by the square of climax index, which was evaluated by the factors of light absorption, reproduction, and wood quality. As the result of analysis, following table shows the oncoming generation of steady state and dominant species in overstory and mid-story by community types. Even though Acer pseudo-sieboldianum and Carpinus cordata could hardly reach the canopy layer due to the intrinsic growth form, these species were predicted to maintain high compositional ratio so as to play an important ecological role in the study forest ecosystem.

Seismic behavior and failure modes of non-ductile three-story reinforced concrete structure: A numerical investigation

  • Hidayat, Banu A.;Hu, Hsuan-Teh;Hsiao, Fu-Pei;Han, Ay Lie;Sosa, Lisha;Chan, Li-Yin;Haryanto, Yanuar
    • Computers and Concrete
    • /
    • v.27 no.5
    • /
    • pp.457-472
    • /
    • 2021
  • Reinforced concrete (RC) buildings in Taiwan have suffered failure from strong earthquakes, which was magnified by the non-ductile detailing frames. Inadequate reinforcement as a consequence of the design philosophy prior to the introduction of current standards resulted in severe damage in the column and beam-column joint (BCJ). This study establishes a finite element analysis (FEA) of the non-ductile detailing RC column, BCJ, and three-story building that was previously tested through a tri-axial shaking table test. The results were then validated to laboratory specimens having the exact same dimensions and properties. FEA simulation integrates the concrete damage plasticity model and the elastic-perfectly plastic model for steel. The load-displacement responses of the column and BCJ specimens obtained from FEA were in a reasonable agreement with the experimental curves. The resulting initial stiffness and maximum base shear were found to be a close approximation to the experimental results. Also, the findings of a dynamic analysis of the three-story building showed that the time-history data of acceleration and displacement correlated well with the shaking table test results. This indicates the FEA implementation can be effectively used to predict the RC frame performance and failure mode under seismic loads.

Dynamic Test of a Full Scale Model of Five-Story Stone Pagoda of Sang-Gye-Sa (쌍계사 오층석탑 실물 크기 모델의 동적 거동 시험)

  • Kim, Jae-Kwan;Ryu, Hyeuk
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.4
    • /
    • pp.51-66
    • /
    • 2001
  • There occurred a moderate size earthquake of Magnitude 5 in Whagae-Myun, Hadong-GUn, Kyongsangnam-Do on July 4, 1936. It caused severe damage to the buildings and other structures in Sang-Gye-Sa, a Buddhist Temple. The top component of a five-story stone pagoda was tipped over and fell down to the ground during the earthquake. In order to have accurate and quantitative estimate of the peak acceleration level of that earthquake, a full-scale model was constructed through rigorous verification process. The complete model was mounted on a shaking table and subjected to the dynamic tests. Two kinds of tests were performed: exploratory test and fragility test. The exploratory test was done with low acceleration level. In the fragility test, the behavior of the model was carefully monitored while increasing the acceleration level. The construction details of the model are provided and test procedures are reported. Finally important test results are presented and their implications are discussed.

  • PDF

Experimental and numerical investigations on seismic performance of a super tall steel tower

  • He, Minjuan;Li, Zheng;Ma, Renle;Liang, Feng
    • Earthquakes and Structures
    • /
    • v.7 no.4
    • /
    • pp.571-586
    • /
    • 2014
  • This paper presents experimental and numerical study on seismic performance of a super tall steel tower structure. The steel tower, with a height of 388 meters, employs a steel space truss with spiral steel columns to serve as its main lateral load resisting system. Moreover, this space truss was surrounded by the spiral steel columns to form a steel mega system in order to support a 12-story platform building which is located from the height of 230 meters to 263 meters. A 1/40 scaled model for this tower structure was made and tested on shake table under a series of one- and two-dimensional earthquake excitations with gradually increasing acceleration amplitudes. The test model performed elastically up to the seismic excitations representing the earthquakes with a return period of 475 years, and the test model also survived with limited damages under the seismic excitations representing the earthquakes with a return period 2475 years. A finite element model for the prototype structure was further developed and verified. It was noted that the model predictions on dynamic properties and displacement responses agreed reasonably well with test results. The maximum inter-story drift of the tower structure was obtained, and the stress in the steel members was investigated. Results indicated that larger displacement responses were observed for the section from the height of 50 meters to 100 meters in the tower structure. For structural design, applicable measures should be adopted to increase the stiffness and ductility for this section in order to avoid excessive deformations, and to improve the serviceability of the prototype structure.