Browse > Article
http://dx.doi.org/10.12989/eas.2014.7.4.571

Experimental and numerical investigations on seismic performance of a super tall steel tower  

He, Minjuan (Department of Building Engineering, Tongji University)
Li, Zheng (Department of Building Engineering, Tongji University)
Ma, Renle (Department of Building Engineering, Tongji University)
Liang, Feng (Architectural Design & Research Institute of Tongji University (Group) Co., Ltd.)
Publication Information
Earthquakes and Structures / v.7, no.4, 2014 , pp. 571-586 More about this Journal
Abstract
This paper presents experimental and numerical study on seismic performance of a super tall steel tower structure. The steel tower, with a height of 388 meters, employs a steel space truss with spiral steel columns to serve as its main lateral load resisting system. Moreover, this space truss was surrounded by the spiral steel columns to form a steel mega system in order to support a 12-story platform building which is located from the height of 230 meters to 263 meters. A 1/40 scaled model for this tower structure was made and tested on shake table under a series of one- and two-dimensional earthquake excitations with gradually increasing acceleration amplitudes. The test model performed elastically up to the seismic excitations representing the earthquakes with a return period of 475 years, and the test model also survived with limited damages under the seismic excitations representing the earthquakes with a return period 2475 years. A finite element model for the prototype structure was further developed and verified. It was noted that the model predictions on dynamic properties and displacement responses agreed reasonably well with test results. The maximum inter-story drift of the tower structure was obtained, and the stress in the steel members was investigated. Results indicated that larger displacement responses were observed for the section from the height of 50 meters to 100 meters in the tower structure. For structural design, applicable measures should be adopted to increase the stiffness and ductility for this section in order to avoid excessive deformations, and to improve the serviceability of the prototype structure.
Keywords
steel tower; seismic performance; shake table test; dynamic property; finite element model;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 He, M.J. and Ma, R.L. (2001), "Measurements and analysis of the vibration of Heilongjiang broadcast and TV steel tower controlled by pendulous tank", J. Build. Struct., 22(1), 39-41, 57. (in Chinese)
2 Breuer, P., Chmielewski, T., Gorski, P., Konopka, E. and Tarczynski, L. (2008), "The stuttgart TV tower-displacement of the top caused by the effects of sun and wind", Eng. Struct., 30(10), 2771-2781.   DOI   ScienceOn
3 Cao, H., Reinhorn, A.M. and Soong, T.T. (1998), "Design of an active mass damper for a tall TV tower in Nanjing, China", Eng. Struct., 20(3), 134-143.   DOI   ScienceOn
4 Chen, W., Lu, Z., Lin, W., Chen, S., Ni, Y., Xia, Y. and Liao, W. (2011), "Theoretical and experimental modal analysis of the Guangzhou New TV Tower", Eng. Struct., 33(12), 3628-3646.   DOI   ScienceOn
5 Chinese Standard GB 50011-2011, Ministry of Housing and Urban-Rural Development of the People's republic of China (MOHURD). (2011), "Code for seismic design of buildings", Beijing, China (in Chinese).
6 Halabian, A.M., Naggar, M.H. and Vickery, B.J. (2002), "Nonlinear seismic response of reinforced-concrete free-standing towers with application to TV towers on flexible foundations", Struct. Des. Tall Spec. Build., 11(1), 51-72.   DOI
7 Khaloo, A.R., Asadpour, N. and Horr, A.M. (2001), "Full dynamic analysis of Tehran telecommunication tower: linear and nonlinear responses", Struct. Des. Tall Spec. Build., 10(4), 263-281.   DOI
8 Park, J.H., Moon, B.W., Min, K.W., Lee, S.K. and Kim, C.K. (2007), "Cyclic loading test of friction-type reinforcing members upgrading wind-resistant performance of transmission towers", Eng. Struct., 29(11), 3185-3196.   DOI
9 Riva, P., Perotti, F., Guidoboni, E. and Boschi, E. (1998), "Seismic analysis of the Asinelli tower and earthquakes in Bologna", Soil Dyn. Earthq. Eng., 17(7-8), 525-550.   DOI
10 Xia, Y., Zhang, P., Ni, Y.Q. and Zhu, H.P. (2014), "Deformation monitoring of a super-tall structure using real-time strain data." Eng. Struct., 67(5), 29-38.   DOI
11 Sabnis, G.M., Harris, H.G. and White, R.N. (1983), "Structure modeling and experimental techniques", Englewood Cliffs, NJ.
12 Walsh, K., Cronin, K., Rambo-Roddenberry, M. and Grupenhof, K. (2012), "Dynamic analysis of seismically excited flexible truss tower with scissor-jack dampers", Struct. Control Health Monit., 19(8), 723-745.   DOI
13 Wu, J.R. and Li, Q.S. (2004), "Finite element model updating for a high-rise structure based on ambient vibration measurements", Eng. Struct., 26(7), 979-990.   DOI   ScienceOn
14 Yahyai, M., Rezayibana, B. and Daryan, A.S. (2009), "Nonlinear seismic response of Milad tower using finite element model", Struct. Des. Tall Spec. Build., 18(8), 877-890.   DOI
15 Zhang, Z., Chen, J. and Li, J. (2013), "Theoretical study and experimental verification of vibration control of offshore wind turbines by a ball vibration absorber", Struct. Infrastruct. Eng., 10(8), 1087-1100.
16 Yi, T.H., Li, H.N. and Gu, M. (2012), "Sensor placement for structural health monitoring of canton tower", Smart. Struct. Syst., 10(4-5), 313-329.   DOI