• Title/Summary/Keyword: storey displacement

Search Result 82, Processing Time 0.018 seconds

Slope topography effect on the seismic response of mid-rise buildings considering topography-soil-structure interaction

  • Shabani, Mohammad J.;Shamsi, Mohammad;Ghanbari, Ali
    • Earthquakes and Structures
    • /
    • v.20 no.2
    • /
    • pp.187-200
    • /
    • 2021
  • The main factor for the amplification of ground motions near the crest or the toe of a slope is the reflection of the incident waves. The effects of the slope topography on the surrounding lands over the crest or at the toe can amplify the seismic responses of buildings. This study investigates the seismic performance of the slope topography and three mid-rise buildings (five, ten, and fifteen-storey) located near the crest and toe of the slope by 3D numerical analysis. The nonlinear model was used to represent the real behavior of building and ground elements. The average results of seven records were used in the investigations. Based on the analysis, the amplification factor of acceleration near the crest and toe of the slope was the most effective at distances of 2.5 and 1.3 times the slope height, respectively. Accordingly, the seismic performance of buildings was studied at a distance equal to the height of the slope from the crest and toe. The seismic response results of buildings showed that the slope topography to have little impact on up to five-storey buildings located near the crest. Taking into account a topography-soil-structure interaction system increases the storey displacement and base shear in the building. Accordingly, in topography-soil-structure interaction analyses, the maximum lateral displacement was increased by 71% and 29% in ten and fifteen-storey buildings, respectively, compare to the soil-structure interaction system. Further, the base shear force was increased by 109% and 78% in these buildings relative to soil-structure interaction analyses.

Failure analysis of reinforced concrete frames with short column effect

  • Caglar, Naci;Mutlu, Mahir
    • Computers and Concrete
    • /
    • v.6 no.5
    • /
    • pp.403-419
    • /
    • 2009
  • Short column effect is cause to failure of columns which may result in severe damages or even collapse during earthquakes. The scope of the study is mainly to reveal the effect of short column on the holistic behaviour of the buildings. The nonlinear analysis of 31 different frame buildings containing short column problem are carried out using finite element method. The finite element models were selected by 2 bays and 3 stories. Since the short columns are generally seen in the first storey of the buildings, in the study, they are only constructed in the same storey. The adverse effect of the short column on the response of buildings was shown in terms of the total load factor and displacement capacity of building. The response of buildings in terms of ground storey displacements is presented in figures and discussed. It is revealed that if the window openings are constructed along the bays, the total load capacity is decreased 85% compared with reference model in which all of bays are filled with infill walls.

Structural seismic response versus epicentral distance and natural period: the case study of Boumerdes (Algeria) 2003 earthquake

  • Dorbani, S.;Badaoui, M.;Benouar, D.
    • Structural Engineering and Mechanics
    • /
    • v.48 no.3
    • /
    • pp.333-350
    • /
    • 2013
  • This paper deals with the development of expressions relating structural seismic response parameters to the epicentral distances of an earthquake and the natural period of several reinforced concrete buildings (6, 9 and 12 storey), with three floor plans: symmetric, monosymmetric, and unsymmetric. These structures are subjected to seismic spectrum of accelerations collected during the Boumerdes earthquake (Algeria, May $21^{st}$, 2003, Mw=6.8) at different epicentral distances. The objective of this study is to develop relations between structural responses namely: base shear, storey displacements, interstory drifts and epicentral distance and fundamental period for a given earthquake. The seismic response of the buildings is carried out in both longitudinal transverse and directions by the response spectrum method (modal spectral approach).

A displacement-based seismic design procedure for buildings with fluid viscous dampers

  • Banuelos-Garcia, Francisco H.;Ayala, Gustavo;Lopez, Saul
    • Earthquakes and Structures
    • /
    • v.18 no.5
    • /
    • pp.609-623
    • /
    • 2020
  • This paper presents a displacement-based seismic design procedure for new structures with fluid viscous dampers and/or for existing structures, where these devices are required as a retrofit measure and damage control. To consider the non-proportional damping produced by these devices in a conventional modal spectral analysis, the effect of the fluid viscous dampers is approximated as the sum of a proportional damping matrix and a complementary matrix which is representative of non-proportional damping matrix. To illustrate the application of this procedure and evaluate the performance of structures designed with the procedure proposed, five regular plane frames: 8, 12, 17, 20 and 25-storey, and an 8-storey building are designed. The seismic demands used for design and validation were the records obtained at the SCT site during the 1985 Michoacan earthquake, and that of the 2017 Morelos - Puebla earthquake obtained at the Culhuacan site, both stations located on soft soil sites. To validate the procedure proposed, the performances and damage distributions used as design targets were compared with the corresponding results from the nonlinear step-by-step analyses of the designed structures subjected to the same seismic demands.

Dynamic displacement tracking of a one-storey frame structure using patch actuator networks: Analytical plate solution and FE validation

  • Huber, Daniel;Krommer, Michael;Irschik, Hans
    • Smart Structures and Systems
    • /
    • v.5 no.6
    • /
    • pp.613-632
    • /
    • 2009
  • The present paper is concerned with the design of a proper patch actuator network in order to track a desired displacement of the sidewalls of a one-storey frame structure; both, for the static and the dynamic case. Weights for each patch of the actuator network found in our previous work were based on beam theory; in the present paper a refinement of these weights by modeling the sidewalls of the frame structure as thin plates is presented. For the sake of calculating the refined weights approximate solutions of the plate equations are calculated by an extended Galerkin method. The solutions based on the analytical plate model are compared with three-dimensional Finite Element results computed in the commercially available code ANSYS. The patch actuator network is put into practice by means of four piezoelectric patches attached to each of the two sidewalls of the frame structures, to which electric voltages proportional to the analytically refined patch weights are applied. Analytical and numerical results coincide very well over a broad frequency range.

Semi-active storey isolation system employing MRE isolator with parameter identification based on NSGA-II with DCD

  • Gu, Xiaoyu;Yu, Yang;Li, Jianchun;Li, Yancheng;Alamdari, Mehrisadat Makki
    • Earthquakes and Structures
    • /
    • v.11 no.6
    • /
    • pp.1101-1121
    • /
    • 2016
  • Base isolation, one of the popular seismic protection approaches proven to be effective in practical applications, has been widely applied worldwide during the past few decades. As the techniques mature, it has been recognised that, the biggest issue faced in base isolation technique is the challenge of great base displacement demand, which leads to the potential of overturning of the structure, instability and permanent damage of the isolators. Meanwhile, drain, ventilation and regular maintenance at the base isolation level are quite difficult and rather time- and fund- consuming, especially in the highly populated areas. To address these challenges, a number of efforts have been dedicated to propose new isolation systems, including segmental building, additional storey isolation (ASI) and mid-storey isolation system, etc. However, such techniques have their own flaws, among which whipping effect is the most obvious one. Moreover, due to their inherent passive nature, all these techniques, including traditional base isolation system, show incapability to cope with the unpredictable and diverse nature of earthquakes. The solution for the aforementioned challenge is to develop an innovative vibration isolation system to realise variable structural stiffness to maximise the adaptability and controllability of the system. Recently, advances on the development of an adaptive magneto-rheological elastomer (MRE) vibration isolator has enlightened the development of adaptive base isolation systems due to its ability to alter stiffness by changing applied electrical current. In this study, an innovative semi-active storey isolation system inserting such novel MRE isolators between each floor is proposed. The stiffness of each level in the proposed isolation system can thus be changed according to characteristics of the MRE isolators. Non-dominated sorting genetic algorithm type II (NSGA-II) with dynamic crowding distance (DCD) is utilised for the optimisation of the parameters at isolation level in the system. Extensive comparative simulation studies have been conducted using 5-storey benchmark model to evaluate the performance of the proposed isolation system under different earthquake excitations. Simulation results compare the seismic responses of bare building, building with passive controlled MRE base isolation system, building with passive-controlled MRE storey isolation system and building with optimised storey isolation system.

Study on the Effective Stiffness of Base Isolation System for Reducing Acceleration and Displacement Responses

  • Kim, Young-Sang
    • Nuclear Engineering and Technology
    • /
    • v.31 no.6
    • /
    • pp.586-594
    • /
    • 1999
  • To limit both the large displacement and acceleration response of the structure efficiently, the relationships between acceleration and displacement responses of the structure under several earthquakes are investigated for various horizontal stiffness of the base isolation system to determine the effective stiffness of the base isolation system in this paper. An example structure is a five-storey steel frame building as the primary structure and the secondary structures are assumed to be located on the fifth floor of the primary structure. Input motions used in the structural analysis are El Centre 1940, Taft 1952, Mexico 1985, San Fernando 1971 Pacoima Dam, and artificially generated earthquakes. The relationships of the absolute peak acceleration and the displacement at the top of the structure are calculated for various natural periods of base isolators under various earthquakes. The peak acceleration response of the fifth floor in the base isolated structure is significantly reduced by a factor of 2.1 through 6.25. Also, the relative displacement response of the floor to the base of the superstructure is very small. The results of this study can be utilized to determine the effective stiffness of the base isolation system.

  • PDF

Surface displacements due to tunneling in granular soils in presence and absence of geosynthetic layer under footings

  • Rebello, Nalini E.;Shivashankar, R.;Sastry, Vedala R.
    • Geomechanics and Engineering
    • /
    • v.15 no.2
    • /
    • pp.739-744
    • /
    • 2018
  • This paper presents the results of numerical modeling studies on the effect of displacements of tunneling in granular soils. Presence of building loads is considered, to find displacement generated at the surface on tunnel. Effect of varying eccentricities of building is simulated, to find influence of building on vertical and horizontal displacement. Studies were carried out in two cases of with and without a geosynthetic layer installed at the bottom of the footing. Results of analysis revealed, the presence of geosynthetic layer under footing, with building placed on centre line, reduced the surface displacements compared to displacement generated without geosynthetic layer. Presence of geosynthetic layer under footing had a dominant effect in reducing displacements in high storey structures. However, when the building was shifted to greater eccentricities from centre line, presence of geosynthetic layer, led to insignificant reduction of displacements on the centre line at the surface.

Stochastic finite element based seismic analysis of framed structures with open-storey

  • Manjuprasad, M.;Gopalakrishnan, S.;Rao, K. Balaji
    • Structural Engineering and Mechanics
    • /
    • v.15 no.4
    • /
    • pp.381-394
    • /
    • 2003
  • While constructing multistorey buildings with reinforced concrete framed structures it is a common practice to provide parking space for vehicles at the ground floor level. This floor will generally consist of open frames without any infilled walls and is called an open-storey. From a post disaster damage survey carried out, it was noticed that during the January 26, 2001 Bhuj (Gujarat, India) earthquake, a large number of reinforced concrete framed buildings with open-storey at ground floor level, suffered extensive damage and in some cases catastrophic collapse. This has brought into sharp focus the need to carry out systematic studies on the seismic vulnerability of such buildings. Determination of vulnerability requires realistic structural response estimations taking into account the stochasticity in the loading and the system parameters. The stochastic finite element method can be effectively used to model the random fields while carrying out such studies. This paper presents the details of stochastic finite element analysis of a five-storey three-bay reinforced concrete framed structure with open-storey subjected to standard seismic excitation. In the present study, only the stochasticity in the system parameters is considered. The stochastic finite element method used for carrying out the analysis is based on perturbation technique. Each random field representing the stochastic geometry/material property is discretised into correlated random variables using spatial averaging technique. The uncertainties in geometry and material properties are modelled using the first two moments of the corresponding parameters. In evaluating the stochastic response, the cross-sectional area and Young' modulus are considered as independent random fields. To study the influence of correlation length of random fields, different correlation lengths are considered for random field discretisation. The spatial expectations and covariances for displacement response at any time instant are obtained as the output. The effect of open-storey is modelled by suitably considering the stiffness of infilled walls in the upper storey using cross bracing. In order to account for changes in soil conditions during strong motion earthquakes, both fixed and hinged supports are considered. The results of the stochastic finite element based seismic analysis of reinforced concrete framed structures reported in this paper demonstrate the importance of considering the effect of open-storey with appropriate support conditions to estimate the realistic response of buildings subjected to earthquakes.

Comparison of Different Numerical Models of RC Elements for Predicting the Seismic Performance of Structures

  • Zendaoui, Abdelhakim;Kadid, A.;Yahiaoui, D.
    • International Journal of Concrete Structures and Materials
    • /
    • v.10 no.4
    • /
    • pp.461-478
    • /
    • 2016
  • This paper aims to provide guidelines for the numerical modeling of reinforced concrete (RC) frame elements in order to assess the seismic performance of structures. Several types of numerical models RC frame elements are available in nonlinear structural analysis packages. Since these numerical models are formulated based on different assumption and theories, the models accuracy, computing time, and applicability vary, which poses a great difficulty to practicing engineering and limits their confidence in the analysis resultants. In this study, the applicability of four representative numerical models of RC frame elements is evaluated through comparison with experimental results of four-storey bare frame available from European Laboratory for Structural Assessment. The accuracy of a numerical model is evaluated according to the top displacement, interstorey drift, Maximum storey shear, damage pattern and energy dissipation capacity of the frame structure. The results obtained allow a better understanding of the characteristics and potentialities of all procedures, helping the user to choose the best approach to perform nonlinear analysis.