• Title/Summary/Keyword: storage system

Search Result 6,942, Processing Time 0.035 seconds

Experimental Evaluation of an Energy Storage Device with High Rotaional Speed (에너지 저장용 고속회전기의 실험적 평가)

  • Lee, Jun-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.193-196
    • /
    • 2014
  • Experimantal evaluation of an energy storage device with high rotational speed to store regenerative energy which might be generated during the braking period of the trains is presented. The proposed ESS is small scale model and has 5kW output power, high rotational speed. In general railway trains generate regenerative energy for 10-20 sec when the train brakes and also high traction energy is needed for very short moment (10 sec) when the train increases the traction force. Considering such characteristics of the railway system energy storage device for the railway should have very fast response property. Among the various energy storage devices flywheel energy storage system has the fastest response property, which means that flywheel ESS is the most suitable for the railway system.

  • PDF

Heating Characteristics of Ondol using Heat Pump-Latent Heat Storage System (열펌프-잠열축열시스템을 이용한 온돌의 난방특성)

  • Kim, M.H.;Song, H.K.
    • Solar Energy
    • /
    • v.20 no.3
    • /
    • pp.1-9
    • /
    • 2000
  • In these days the hot water circulating Ondol using the fossil fuel boiler is the heating system for the most of the Korean residents. Then it is installed without the heat storage medium in the Ondol heating layer, but the Korean traditional Ondol had been composed with the heat storage medium. The Ondol room without heat storage medium could not be comfortable because the room air temperature is not only changed unstably but also it has a defect too much fuel consumption. Therefore in this study the heat pump-latent heat storage Ondol as the new type of Ondol system was developed to solve these problems mentioned above, and the COP of the heat pump (Coefficient Of Performance), the latent heat storage characteristics in the new type of Ondol system and the temperature variation in the Ondol room with the ambient temperature were analyzed.

  • PDF

Optimal Scheduling of Multi-product Batch Process for Common Intermediate Storage Policy; A Model for Batch Process Automation (다품종용 회분식 공정에서의 중간 저장 탱크 공유를 위한 최적 생산계획 ; 회분식 조업의 자동화 모델)

  • 정재학;이인범;양대륙;장근수
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10a
    • /
    • pp.303-308
    • /
    • 1992
  • In this study, we propose a shared storage system which is more efficient policy than MIS(Mixed Intermediate Storage) policy for relatively rare storage system and can be called CIS(Common Intermediate Storage) policy. Using this strategy, we develop a new completion time algorithm and apply it to two kinds of optimal or near optimal scheduling method; combinatorial search and simulated annealing method. We also extend this strategy to other storage policy, for example MIS policy, with PLC(Programmable Logic Controller) logic and on/off action of electronic valves. It thus can be accepted as a basic form of FMS(Flexible Manufacturing System) for operating various storage policies. Finally we suggest the interlocking block to compansate for the shortcoming of CIS policy, i.e, complication of operation and safety, resulting in a basic batch process automation mode.

  • PDF

Seismic Fragility Analysis of Base Isolated Liquid Storage Tank (면진 유체 저장 탱크의 지진취약도 분석)

  • Ahn, Sung-Moon;Choi, In-Kil;Choun, Young-Sun
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2005.03a
    • /
    • pp.453-460
    • /
    • 2005
  • In this study, the seismic fragility analysis of a base isolated condensate storage tank installed in the nuclear power plant. The condensate storage tank is safety related structure in a nuclear power plant. The failure of this tank affect significantly to the core damage frequency of the nuclear power plants. The seismic analysis of the liquid storage tank was performed by the simple calculation method and the dynamic time storage analysis method. The convective and impulsive fluid mass is modeled as added masses proposed by several researchers. To evaluate the effectiveness of the isolation system, the comparison of HCLPF and core damage frequencies in non-isolated and isolated cases are carried out. It can be found from the results that the seismic isolation system increases the seismic capacity of a condensate storage tank and decreases the core damage frequency significantly.

  • PDF

Implementation of Group Office System Based on Internet (인터넷 기반의 그룹 오피스 시스템 구현)

  • Kim Kyoung-Rok;Song Seok-Il;Kwak Yoon-Sik
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.3
    • /
    • pp.540-546
    • /
    • 2005
  • In this paper, we design and implement a distributed web-storage and a group office system based on the distributed web-storage. It is easier to customize the proposed group office according to user's demands than existing web-based applications. Our proposed web-storage is distributed system which consists of multiple storage servers. The web-storage provides storage with considering the user's location so as to provide fast storage service.

Physicochemical Changes of Wanja-jeon during Cold Storage for Hospital Cook/Chill Foodservice System (병원의 냉장저장급식제도를 위해 조리된 완자전의 냉장저장 중 이화학적 성분변화)

  • 임양이;김혜영;강태수
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.26 no.6
    • /
    • pp.1221-1227
    • /
    • 1997
  • To measure nutritional components and physical quality of Wanja-jeon(Korean pan fried meat balls)was investigated during storage in a simulated hospital cook/chill foodservice system. The Wanja-jeon was cooked and stored for 4 weeks in chill conditions of 2 and 7$^{\circ}C$ and then reheated in the microwave oven. Moisture, protein, and fat contents were decreased little during 4 weeks storage at 2 and 7$^{\circ}C$. Total unsaturated fatty acids(TUFA) and polyunsaturated fatty acids(PUFA) increased slightly at 7$^{\circ}C$ storage. Total free amino acid contents were reduced after 4 weeks of storage, while total amino acids were affected little during chilled storage. However, volatile basic nitrogen(VBN) increased during the 4 weeks storage from 11.2mg%, immediately after cooking, to 14.1~14.2mg%. After reheating, thiobarbituric acid(TBA) value increased more significantly to 0.19 and 0.20.

  • PDF

Analysis and Design of Profiling Adaptor for XML based Energy Storage System (XML 기반의 에너지 저장용 프로파일 어댑터 분석 및 설계)

  • Woo, Yongje;Park, Jaehong;Kang, Mingoo;Kwon, Kiwon
    • Journal of Internet Computing and Services
    • /
    • v.16 no.5
    • /
    • pp.29-38
    • /
    • 2015
  • The Energy Storage System stores electricity for later use. This system can store electricity from legacy electric power systems or renewable energy systems into a battery device when demand is low. When there is high electricity demand, it uses the electricity previously stored and enables efficient energy usage and stable operation of the electric power system. It increases the energy usage efficiency, stabilizes the power supply system, and increases the utilization of renewable energy. The recent increase in the global interest for efficient energy consumption has increased the need for an energy storage system that can satisfy both the consumers' demand for stable power supply and the suppliers' demand for power demand normalization. In general, an energy storage system consists of a Power Conditioning System, a Battery Management System, a battery cell and peripheral devices. The specifications of the subsystems that form the energy storage system are manufacturer dependent. Since the core component interfaces are not standardized, there are difficulties in forming and operating the energy storage system. In this paper, the design of the profile structure for energy storage system and realization of private profiling system for energy storage system is presented. The profiling system accommodates diverse component settings that are manufacturer dependent and information needed for effective operation. The settings and operation information of various PCSs, BMSs, battery cells, and other peripheral device are analyzed to define profile specification and structure. A profile adapter software that can be applied to energy storage system is designed and implemented. The profiles for energy storage system generated by the profile authoring tool consist of a settings profile and operation profile. Setting profile consists of configuration information for energy device what composes energy saving system. To be more specific, setting profile has three parts of category as information for electric control module, sub system, and interface for communication between electric devices. Operation profile includes information in relation to the method in which controls Energy Storage system. The profiles are based on standard XML specification to accommodate future extensions. The profile system has been verified by applying it to an energy storage system and testing charge and discharge operations.

Seismic Design for Application of LNG Storage Tank Isolation System (LNG 저장탱크의 면진시스템 적용을 위한 내진설계)

  • Seo, Ki-Young;Park, Hyun-Jae;Kim, Nam-Sik;Kim, Jae-Min;Yang, Seong-Yeong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.3
    • /
    • pp.227-235
    • /
    • 2014
  • The demand of natural gas is gradually increasing as a clean fuel in the world. Therefore, LNG storage tanks and related facilities of the importance of leading a community-based facility have emerged. The seismic design of LNG storage tank including seismic analysis have been developed steadily. But, the seismic analysis and design techniques for LNG storage tanks are lacking, in Korea. Consequently, it is necessary to develop an analysis model that LNG storage tanks in isolation system can describe the behavior. Further, LNG storage tank capable of ensuring safety and economy, it is necessary to develop design techniques. The studies have suggested seismic design procedures of LNG storage tanks with isolation system including triple-FPB and idealized complex hysteresis model of triple-FPB.

Technology Trend of Next Generation Information Storage Systems (차세대 정보저장시스템 최신 기술 동향)

  • Park Young-Pil;Rhim Yun-Chul;Yang Hyun-Seok;Kang Shinill;Park No-Cheol;Kim Young-Joo
    • Transactions of the Society of Information Storage Systems
    • /
    • v.1 no.1
    • /
    • pp.1-22
    • /
    • 2005
  • There are two important trends in the modern information society, including digital networking and ubiquitous environment. Thus it is strongly required to develop new information storage devices such as high density storages to match the increased data capacity and small size storage devices to be applied to the mobile multimedia electronics. So far, many approaches have been studied for the high density memory, including the holographic memory, super-RENS and near-field recording using solid immersion lens (SIL) or nano-probe for the ODD (Optical Disk Drive) system, and the perpendicular magnetic recording and heat-assisted magnetic recording for the HDD (Hard Disk Drive) system. In addition, new mobile storage devices have been prepared using 0.85" HDD and 30mm ODD systems from a lot of foreign and domestic companies and institutes. In this paper, the recent technology trend for the next generation information storage system is summarized to offer a research motivation and encouragement to new researchers in this field with an emphasis on the technical issues of the increase of data capacity and decrease of device size.

  • PDF

Heat Transfer Characteristics of the Spherical Capsule Storage System Using Paraffins

  • Cho, Keum-Nam;Choi, S. H.
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.6
    • /
    • pp.113-123
    • /
    • 1998
  • The present study is to investigate the effect of experimental parameters on the heat transfer characteristics of a spherical capsule storage system using paraffins. N-Tetradecane and mixture of n-Tetradecane 40% and n-Hexadecane 60% were used as paraffins. Water with inorganic material was also tested for the comparison. The experimental parameters were varied for the Reynolds number from 8 to 16 and for the inlet temperature from -7 to 2$^{\circ}C$. Measured local temperatures of spherical capsules in the storage tank were utilized to calculate charging and discharging times, dimensionless thermal storage amount, and the average heat transfer coefficients in the tank. Local charging and discharging times in the storage tank were significantly different. The effect of inlet temperature on charging time was larger than that on discharging time, but the effect of Reynolds number on charging time was smaller than that on discharging time. Charging time of paraffins was faster by 11~72% than that of water with inorganic material, but little difference of discharging time was found among them. The effect of Reynolds number on the dimensionless thermal storage was less during charging process and more during discharging process than the effect of inlet temperature. The effect of the inlet temperature and the Reynolds number on the average heat transfer coefficient of the storage tank was stronger during discharging process than during charging process. The average heat transfer coefficients of the spherical capsule system using paraffins were larger by 40% than those using water.

  • PDF