• Title/Summary/Keyword: storage management

Search Result 2,631, Processing Time 0.03 seconds

Development of ESS Fair Trade System Linked with Blockchain (블록체인을 연계한 ESS 공정거래 시스템 개발)

  • Gun-Il Kim;Yang-Kwon Jeong;Young-Sik Kim;Jin-Suk Kim
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.1
    • /
    • pp.149-156
    • /
    • 2023
  • This research tried to develop an ESS electricity trading system linked with blockchain for energy participation consumers. For the purpose of publishing renewable energy ESS power amount and demand information, we will build a smart contract system on the blockchain DB, utilize the blockchain DB data of energy prosumers and consumers, and expand the power trading market flexibly. to provide realistic solutions. Therefore, the main contents of the development of the ESS power trading system linked to the blockchain are cloud-based web construction for ESS management, coin issuance and exchange registration for activating the blockchain, and to reflect the blockchain technology, building a blockchain database for collecting and supplying ESS-based production demand data, selecting a blockchain-based platform and building a foundation, and creating a smart contract, etc.

Implementation of marine static data collection and DB storage algorithms (해양 정적 데이터 수집 및 DB 저장 알고리즘 구현)

  • Seung-Hwan Choi;Gi-Jo Park;Ki-Sook Chung;Woo-Sug Jung;Kyung-Seok Kim
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.2
    • /
    • pp.95-101
    • /
    • 2023
  • Globally, the importance of utilization and management of marine spatial information is being maximized, and analyzing such data is emerging as a major driving force for R&D. In Korea, it is expected that collecting marine data from the past to the present and extracting its value will play an important role in the development of science in Korea in the future. In particular, marine static data constitutes a huge big database, and it is necessary to store and store the collected data without loss as high data collection costs and high-level observation techniques are required. In addition, the Disaster Safety Intelligence Convergence Center's "Marine Digital Twin Establishment and Utilization-Based Technology Research" task requires collection and analysis of marine data, so this paper conducts a current status survey of static marine data. And we present a series of algorithms that collect and store them in a database.

Development of a decision scaling framework for drought vulnerability assessment of dam operation under climate change (Decision Scaling 기반 댐 운영 기후변화 가뭄 취약성 평가)

  • Kim, Jiheun;Seo, Seung Beom;Cho, Jaepil
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.4
    • /
    • pp.273-284
    • /
    • 2023
  • Water supply is continuously suffering from frequent droughts under climate change, and such extreme events are expected to become more frequent due to climate change. In this study, the decision scaling method was introduced to evaluate the drought vulnerability under future climate change in a wider range. As a result, the water supply reliability of the Boryeong Dam ranged from 95.80% to 98.13% to the condition of the aqueduct which was constructed at the Boryeong Dam. Furthermore, the Boryeong Dam was discovered to be vulnerable under climate change scenarios. Hence, genetic algorithm-based hedging rules were developed to evaluate the reduction effect of drought vulnerability. Moreover, three demand scenarios (high, standard, and low demand) were also considered to reflect the future socio-economic change in the Boryeong Dam. By analyzing quantitative reliability and the probability of extreme drought occurrence under 5% of the water storage rate, all hedging rules demonstrated that they were superior in preparing for extreme drought under low-demand scenarios.

A Study on the Deduction of Satisfaction Survey Factors in the Study of One-person Living Sharehouse (1인 거주 쉐어하우스 연구에서 만족도 조사항목 추출에 관한 연구)

  • Kim, So-ra;Kang, Mi-hyun;Lee, Min-hee
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.24 no.4
    • /
    • pp.33-40
    • /
    • 2022
  • Sharehouse has been supplied as an alternative to solving the steadily increasing one-room housing problem of single-person households every year, and it is necessary to investigate the satisfaction of residents who actually live in sharehouse through P.O.E. Therefore, this study analyzed priror researches related to the existing one-person households, sharehouses, and satisfaction surveys, and summarized indicators with high relevance and frequency to derive satisfaction survey factors that can clearly evaluate the improvement architectural plan of sharehouses. As a result, it was classified into 4 items in the 'general information' category to investigate the status, housing rental type, and housing cost of the sharehouse, 15 factors in the 'peripheral environment' category to evaluate the safety, 3 factors in the 'community' category, and 17 factors in the space (facility) and service category. In the "General Information" section, the overall one-person housing satisfaction, desired sharehouse type, housing rental type, housing cost, and living expenses were reduced. In the "Surrounding Environment", accessibility to public office, accessibility to cultural facilities, accessibility to medical facilities, accessibility to work and school, convenience stores, noise pollution and safety. In addition, in the "community" section, it consists of interactions with various people, relationships with housemates and in the "space (facilities) and service" section, heating, waterproof, soundproof, ventilation, moisture and condensation blocking, facility management, interior, room size, built-in furniture, storage space, laundry, parking. Most of the scales for each factor were 5-point Likert scales, allowing evaluation of the degree of satisfaction, and some factors presented criteria to induce structured answers. Therfore, it is expected that the survey will be conducted on residents who actually live by deriving factors for the satisfaction survey of one-person households living in the sharehouse, and the current status of the sharehouse will be identified, and the degree of satisfaction will be analyzed to be used for research.

Study on an open fuel cycle of IVG.1M research reactor operating with LEU-fuel

  • Ruslan А. Irkimbekov ;Artur S. Surayev ;Galina А. Vityuk ;Olzhas M. Zhanbolatov ;Zamanbek B. Kozhabaev;Sergey V. Bedenko ;Nima Ghal-Eh ;Alexander D. Vurim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.4
    • /
    • pp.1439-1447
    • /
    • 2023
  • The fuel cycle characteristics of the IVG.1M reactor were studied within the framework of the research reactor conversion program to modernize the IVG.1M reactor. Optimum use of the nuclear fuel and reactor was achieved through routine methods which included partial fuel reloading combined with scheduled maintenance operations. Since, the additional problem in planning the fuel cycle of the IVG.1M reactor was the poisoning of the beryllium parts of the core, reflector, and control system. An assessment of the residual power and composition of spent fuel is necessary for the selection and justification of the technology for its subsequent management. Computational studies were performed using the MCNP6.1 program and the neutronics model of the IVG.1M reactor. The proposed scheme of annual partial fuel reloading allows for maintaining a high reactor reactivity margin, stabilizing it within 2-4 βeff for 20 years, and achieving a burnup of 9.9-10.8 MW × day/kg U in the steady state mode of fuel reloading. Spent fuel immediately after unloading from the reactor can be placed in a transport packaging cask for shipping or safely stored in dry storage at the research reactor site.

Contactless Access Certification Management System for Infection Control in Special Rooms in Medical Institutions (의료기관 특수실 감염관리를 위한 비접촉 출입인증 관리 시스템)

  • Lee, Hyo-Seung;Choi, Woo-Jin
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.2
    • /
    • pp.387-392
    • /
    • 2022
  • In addition to complying with access standards for facilities that require infection control (operating rooms, delivery rooms, intensive care units, etc.) in accordance with the 2019 Medical Care Act Enforcement Regulations, entry, exit, contact information, etc. for entry and exit, the criteria for entering and exiting special rooms of medical institutions have been revised so that records of facts are kept for one year. However, even now, the inconvenience continues due to the fact that such contents are created by hand or due to errors. For this reason, this study designed and implemented a system that provides automatic opening, closing, and accessing record storage functions for authorized users using IoT devices and UWB technology, and we expected that the convenience of the visitors and systemized access control will be possible.

Development of Complex Module Device for Odor Reduction in Sewage

  • KIM, Young-Do;JEONG, Tae-Hwan;Kim, Su-Hye;KWON, Woo-Taeg
    • Journal of Wellbeing Management and Applied Psychology
    • /
    • v.5 no.4
    • /
    • pp.51-56
    • /
    • 2022
  • Purpose: By applying an ultrasonic mechanical device to the liquid fertilizer storage in the pig dropping treatment plant, the initial odor of the odor source is reduced, and the air dilution drainage of the complex odor is fundamentally recognized to facilitate odor treatment on the mechanical and chemical biological treatment devices at the rear. Research design, data and methodology: The odor concentration on the site boundary was measured to confirm the state of reduction. In order to prevent the spread of odor from the collection of the pig dropping treatment plant, it was measured by installing an ultrasonic generator inside the installation wall after installing the sealing wall. Results: The average value of the March and April measurement data remained close to neutral at 8.2 after 8.6 treatment before pH treatment, decreased 97.3% from 462 mg/L before SS treatment to 10.5 mg/L after treatment, and the composite odor was reduced by 85% from 20 to 3 before treatment. It was confirmed that ammonia (NH3) was reduced by 99% from 5.8 ppm to 0.09 ppm, and general bacteria were also reduced by 99% from 3,200 CFU/mL to 57 CFU/mL Conclusion: Applying the ultrasonic air ejector hybrid system and zigzag air complex module development product to resource circulation centers or sewage treatment facilities is thought to reduce inconvenience to residents due to odors caused.

A Comparative Study Between High and Low Infiltration Soils as Filter Media in Low Impact Development Structures

  • Guerra, Heidi B.;Geronimo, Franz Kevin;Reyes, Nash Jett;Jeon, Minsu;Choi, Hyeseon;Kim, Youngchul;Kim, Lee-Hyung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.130-130
    • /
    • 2021
  • The increasing effect of urbanization has been more apparent through flooding and downstream water quality especially from heavy rainfalls. In response, stormwater runoff management solutions have focused on runoff volume reduction and treatment through infiltration. However, there are areas with low infiltration soils or are experiencing more dry days and even drought. In this study, a lab-scale infiltration system was used to compare the applicability of two types of soil as base layer in gravel-filled infiltration systems with emphasis on runoff capture and suspended solids removal. The two types of soils used were sandy soil representing a high infiltration system and clayey soil representing a low infiltration system. Findings showed that infiltration rates increased with the water depth above the gravel-soil interface indicating that the available depth for water storage affects this parameter. Runoff capture in the high infiltration system is more affected by rainfall depth and inflow rates as compared to that in the low infiltration system. Based on runoff capture and pollutant removal analysis, a media depth of at least 0.4 m for high infiltration systems and 1 m for low infiltration systems is required to capture and treat a 10-mm rainfall in Korea. A maximum infiltration rate of 200 mm/h was also found to be ideal to provide enough retention time for pollutant removal. Moreover, it was revealed that low infiltration systems are more susceptible to horizontal flows and that the length of the structure may be more critical that the depth in this condition.

  • PDF

A Design of Industrial Safety Service using LoRa Gateway Networks (LoRa 게이트웨이 네트워크를 활용한 산업안전서비스 설계)

  • Chang, Moon-soo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.10a
    • /
    • pp.313-316
    • /
    • 2021
  • In the IoT(IoT: Internet of Things) environment, network configuration is essential to collect data generated from objects. Various communication methods are used to process data of objects, and wireless communication methods such as Bluetooth and WiFi are mainly used. In order to collect data of objects, a communication module must be installed to collect data generated from sensors or edge devices in real time. And in order to deliver data to the database, a software architecture must be configured. Data generated from objects can be stored and managed in a database in real time, and data necessary for industrial safety can be extracted and utilized for industrial safety service applications. In this paper, a network environment was constructed using a LoRa(LoRa: Long Range) gateway to collect object data, and a client/server data collection model was designed to collect object data transmitted from the LoRa module. In order to secure the resources necessary for data collection and storage management without data leakage, data collection should be possible in real time. As an application service, location data required for industrial safety can be stored and managed in a database in real time.

  • PDF

Cohort Profile: Korean Tuberculosis and Post-Tuberculosis Cohort Constructed by Linking the Korean National Tuberculosis Surveillance System and National Health Information Database

  • Jeong, Dawoon;Kang, Hee-Yeon;Kim, Jinsun;Lee, Hyewon;Yoo, Bit-Na;Kim, Hee-Sun;Choi, Hongjo
    • Journal of Preventive Medicine and Public Health
    • /
    • v.55 no.3
    • /
    • pp.253-262
    • /
    • 2022
  • We aimed to review the current data composition of the Korean Tuberculosis and Post-Tuberculosis Cohort, which was constructed by linking the Korean Tuberculosis Surveillance System (KNTSS; established and operated by the Korean Disease Control and Prevention Agency since 2000) and the National Health Information Database (NHID; established by the National Health Insurance Service in 2012). The following data were linked: KNTSS data pertaining to patients diagnosed with tuberculosis between 2011 and 2018, NHID data of patients with a history of tuberculosis and related diseases between 2006 and 2018, and data (obtained from the Statistics Korea database) on causes of death. Data from 300 117 tuberculosis patients (177 206 men and 122 911 women) were linked. The rate of treatment success for new cases was highest in 2015 (86.7%), with a gradual decrease thereafter. The treatment success rate for previously treated cases showed an increasing trend until 2014 (79.0%) and decreased thereafter. In total, 53 906 deaths were confirmed among tuberculosis patients included in the cohort. The Korean Tuberculosis and Post-Tuberculosis Cohort can be used to analyze different measurement variables in an integrated manner depending on the data source. Therefore, these cohort data can be used in future epidemiological studies and research on policy-effect analysis, treatment outcome analysis, and health-related behaviors such as treatment discontinuation.