• 제목/요약/키워드: storage heat flux

검색결과 64건 처리시간 0.026초

기상 조건에 따른 도시 캐노피 모형의 성능 비교 (Performance Comparison of an Urban Canopy Model under Different Meteorological Conditions)

  • 유영희;백종진;이상현
    • 대기
    • /
    • 제22권4호
    • /
    • pp.429-436
    • /
    • 2012
  • The performances of the Seoul National University Urban Canopy Model (SNUUCM) under different meteorological conditions (clear, cloudy, and rainy conditions) in summertime are compared using observation dataset obtained at an urban site. The daily-averaged net radiation, sensible heat flux, and storage heat flux are largest in clear days and smallest in rainy days, but the daily-averaged latent heat flux is similar among clear, cloudy, and rainy days. That is, the ratio of latent heat flux to net radiation increases in order of clear, cloudy, and rainy conditions. In general, the performance of the SNUUCM is better in clear days than in cloudy or rainy days. However, the performance in simulating sensible heat flux in clear days is as poor as that in rainy days. For all the meteorological conditions, the performance in simulating latent heat flux is worst among the performances in simulating net radiation, sensible heat flux, and latent heat flux. The normalized mean error for latent heat flux is largest in rainy days in which the relative importance of latent heat flux in the surface energy balance becomes greatest among the three conditions. This study suggests that improvements to the parameterization of processes that are related to latent heat flux are particularly needed.

석유류 저장 탱크에서의 액면 및 유츌화재에 대한 복사열의 실험적 연구 (Experimental Study of Radiation Heat Flux for the Pool and Spill Fire in Petroleum Storage Tanks)

  • 김홍;박형주
    • 한국안전학회지
    • /
    • 제19권1호
    • /
    • pp.88-93
    • /
    • 2004
  • This experimental study was carried out to evaluate effect of the radiation heat flux for the pool and spill fire in petroleum storage tanks, which were made form steel. Each of them had the capacity of 250, 2500 and 25000 liter, respectively. The effects of the radiation heat flux are as follows; 1) The intensity of radiation heat flux from a flame decreased exponentially with increasing distance from outside wall of tanks, and increased significantly with surface area of tank and dyke. 2) In the case of 25000L tank, the radiation heat flux was about max. 98.9kW/$m^2$ in 1m from wall of tank. 3) The distance, that was able to ignite wood or plastics by radiation heat flux of approximately 12.5kW/$m^2$, was about 3.14m from wall of 25000L tank.

득량만의 열수지 계절 변동 (The Seasonal Variation of the Heat Budget in Deukryang Bay)

  • 주용환;조규대
    • 한국환경과학회지
    • /
    • 제7권1호
    • /
    • pp.67-73
    • /
    • 1998
  • Surface heat budget of the Deukryang Bay from July 1, 1992 to September 12, 1993 is analyzed by us- ing the meteorological data (by Changhung Observatory and Mokpo Meteorological Station) and oceanogaphical data (by Research Center for Ocean Industrial Development. Pukyong National University). Each flux element at the sea surface which has annual variation Is derived with application of an aerodynamical bulk method and empirical formulae. The solar radiation Is the maximum In spring and sensible heat are the maximum in autumn and water. and minimum in summer The heat .storage rate is calclilated by using the rate of water temperature variation according to the depth. The oceanic transport heat is estimated as a residual. The net heat flux, the heat storage rate are positive In spring and summer, while they are negative in autumn and winter. The oceanic transport heat Is convergence In winter and divergence In the rest of seasons.

  • PDF

낙동강 강정고령보의 여름철 열수지 일변화 - 열 저장량 변동을 중심으로 - (Daily Variation of Heat Budget Balance in the Gangjeong-Goryung Reservoir for Summertime - Concerning around the Rate of Heat Storage -)

  • 김성락;조창범;김해동
    • 한국환경과학회지
    • /
    • 제24권6호
    • /
    • pp.721-729
    • /
    • 2015
  • Surface heat balance of the Gangjeong-Goryung Reservoir is analyzed for 12-17 August 2013. Each flux elements at the water surface is derived from the special field observations with application of an aerodynamical bulk method for the turbulent heat fluxes and empirical formulae for the radiation heat fluxes. The rate of heat storage in the reservoir is estimated by using estimated by surface heating rate and the vertical water temperature data. The flux divergence of heat transport is estimated as a residual. The features of the surface heat balance are almost decided by the latent heat flux and the solar radiation flux. On average for 12-17 August 2014 in the Gangjeong- Goryung Reservoir, if one defines the insolation at the water surface as 100 %, 94 % is absorbed in the reservoir; thereafter the reservoir loses about 30~50% by sensible heat, latent heat and net long-wave radiation. The residue of 50~80 % raises the water temperature in the reservoir or transported away by the river flow during the daytime.

제주도 북부해역의 표면 열수지 해석 -1993년과 1994년 하계의 경우- (Surface Heat Budget of the Northern Sea of Cheju Island for June-August 1993 and 1994)

  • 김해동;양성기
    • 한국환경과학회지
    • /
    • 제4권3호
    • /
    • pp.197-206
    • /
    • 1995
  • Surface heat balance of the northern sea of Cheju Island for summer in 1993 and 1994 is analyzed using the observation data obtained by Marine Research Institute, Cheju National University. Each flux elements at the sea surface is derived from the marine meteorological reports with application of an aerodynamical bulk method for the turbulent heat fluxes, and empirical formulae for the long-wave radiation heat fluxes. The flux divergence of oceanic heat transport and the rate of heat storage in the ocean are estimated as residual. The features of the surface heat balance are mainly decided by the solar radiation flux and the latent heat flux for 199B. But the Bowen Ratios were large for 1993. This means that the sensible heat fluxes were nearly equal to the latent heat fluxes for 1993. In this period, mean flux divergence of oceanic heat transport is about 130 W/$m^2$.

  • PDF

금속스크랩이 혼합된 상변화물질의 유효열전도율 (Effective thermal conductivity of the phase change material with metal scrap)

  • 김시범;노승탁
    • 대한기계학회논문집
    • /
    • 제10권6호
    • /
    • pp.923-928
    • /
    • 1986
  • 본 논문에서는 열전도율이 큰 금속의 스크랩과 파라핀을 혼합한 축열 매질에 있어서 스크랩의 체적 혼합율에 따르는 열전도율의 변화를 모델링과 실험으로 구해서 축열 계산에 필요한 열전도율 자료를 제시하고자 한다.

수소 저장합금층의 열전달 촉진을 위한 진동형 히트 파이프 적용에 관한 연구 (A Study of Application on the Pulsating Heat Pipe for Heat Transfer Enhancement of Metal Hydride Alloy)

  • 이민재;임용빈;배상철;김종수
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.346-351
    • /
    • 2006
  • When metallic alloys are reacted to hydrogen, heat transfer of storage tank effects hydrogen storage rate and capacity. If pulsating heat pipe are used to improve heat transfer efficiency, production of hydrogen storage tank can be more simple and economical. Experiment of heat pipe was conducted by varying working fluids and heat flux. According to supply heat flux, test indicate that R-22 and R-l42b were found lower temperature difference between evaporator and condenser than R-134a and Ethanol. Thermal resistances of R-22 and R-142b were also lower than others. Using R-142b as a working fluid, heat pipe type hydrogen storage tank is tested in absorption and desorption processes.

  • PDF

Numerical study on Comparison of Self-Pressurization Behavior of Liquid Nitrogen Cryostat for Umbilical Cord Blood Storage System Design

  • Mahfud, M.I.;Phil, K.E.
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.409-414
    • /
    • 2009
  • Since cryogens are stored at very low temperatures, the cryogenic storage systems are quite sensitive to heat leaks. Even though the vessel operated under sealed condition with vacuum insulation and reflective coatings are used, the heat leakage into the vessel is still unavoidable. Therefore, this paper concerns with numerical study of self-pressurization used to analysis the optimum design with the variation volume fraction, effect of heat flux and storage pressure of liquid nitrogen. The result shows that as the volume fraction increases, the pressure rise reduces and the relatively at atmosphere pressure is better than the higher one. In addition, higher heat flux leads the pressure rise increases faster than low one. The additional of heat pipe system to reduce the pressure rise rate also has been done. By this comparison, the optimum design for storage umbilical cord blood can be selected.

  • PDF

HadGEM2-AO를 이용한 북서태평양-동아시아 해역의 표층 수온 모의 특성 분석 (Analysis of Sea Surface Temperature Simulation in the Northwestern Pacific and the East Asian Marginal Seas using HadGEM2-AO)

  • 김해진;김철호;신홍렬
    • Ocean and Polar Research
    • /
    • 제38권2호
    • /
    • pp.89-102
    • /
    • 2016
  • In this study, we evaluated the model performance with respect to Sea Surface Temperature (SST) and Net Heat Flux (NHF) by considering the characteristics of seasonal temperature variation and contributing factors and by analyzing heat budget terms in the Northwestern Pacific and East Asian Marginal Seas ($110^{\circ}E-160^{\circ}E$, $15^{\circ}N-60^{\circ}N$) using the HadGEM2-AO historical run. Annual mean SST of the HadGEM2-AO is about $0.065^{\circ}C$ higher than observations (EN3_v2a) from 1950 to 2000. Since 1960, the model has simulated well the long-term variation of SST and the increasing rate of SST in the model ($0.014^{\circ}C/year$) is comparable with observations ($0.013^{\circ}C/year$). Heat loss from the ocean to the atmosphere was simulated slightly higher in the HadGEM2-AO than that in the reanalysis data on the East Asian Marginal Seas and the Kuroshio region. We investigated the causes of temperature variation by calculating the heat budget equation in the two representative regions. In the central part of the Kuroshio axis ($125^{\circ}E-130^{\circ}E$, $25^{\circ}N-30^{\circ}N$: Region A), both heat loss in the upper mixed layer by surface heat flux and vertical heat advection mainly cause the decrease of heat storage in autumn and winter. Release of latent heat flux through the heat convergence brought about by the Kuroshio contributes to the large surface net heat flux. Positive heat storage rate is mainly determined by horizontal heat advection from March to April and surface net heat flux from May to July. In the central part of the subtropical gyre ($155^{\circ}E-160^{\circ}E$, $22^{\circ}N-27^{\circ}N$: Region B), unlike Region A, vertical heat advection predominantly causes the decrease of heat storage in autumn and winter. In spring and summer, surface heat flux contributes to the increase of heat storage in Region B and the period is two times longer than the period for Region A. In this season, shoaling of the mixed layer depth plays an important role in the increase of SST.

우리나라 도심지에서의 저장열 산출에 관한 연구 (A Study on Retrieval of Storage Heat Flux in Urban Area)

  • 이다래;김홍희;이상현;이두일;홍진규;홍제우;이근민;이경상;서민지;한경수
    • 대한원격탐사학회지
    • /
    • 제34권2_1호
    • /
    • pp.301-306
    • /
    • 2018
  • 도시화는 여름철 도시형 홍수, 도시 열섬 등의 문제를 야기시킨다. 이러한 현상을 해결하기 위해서는 도시 열환경 변화의 정확한 파악이 필요하다. 이는 에너지 수지를 통해 설명될 수 있지만, 도심지의 경우 일반적인 에너지 수지와 달리 건물이나 인공토지피복에 의해 저장된 열에너지인 저장열을 고려하여야 한다. 하지만 저장열은 도시 표면의 복잡한 3차원 구조와 피복의 다양성 때문에 그 산출이 어려우며, 도시마다 다른 환경으로 인해 선행연구의 저장열 산출 방법을 타 도심지에 적용시키는 데는 어려움이 존재한다. 특히 대부분의 선행연구는 국외 도시를 중심으로 이루어졌기 때문에 국내 도심지의 다양한 토지피복과 건물 특성에 적합한 저장열 산출 연구가 필요하다. 따라서 본 연구에서는 국내 도심지의 다양한 지표타입이 존재하는 지역의 자료를 이용하여 저장열의 정량적인 산출이 가능한 회귀 식 도출을 목적으로 한다. 이를 위해 순복사와 지표면 온도 자료를 독립변수로, 플럭스 타워 기반 저장열 추정치를 종속변수로 사용하여 비선형 회귀분석을 수행하였으며, 산출된 회귀계수를 각 독립변수에 적용하여 저장열 산출 회귀 식을 도출하였다. 플럭스 타워 기반 저장열 추정치의 시계열 분석 결과 본 연구에서 산출한 저장열이 주간의 high peak와 야간에서의 값의 분포와 경향을 잘 모의하고 있었고, 플럭스 타워 기반 저장열 추정치에 비해 연속적인 저장열 산출이 가능하였다. 또한 산점도 분석 결과 Root Mean Square Error (RMSE) $50.14Wm^{-2}$, bias $-0.94Wm^{-2}$로 유의한 수준의 정확도를 보였다.