• Title/Summary/Keyword: storage facility

검색결과 603건 처리시간 0.029초

Electro-Osmotic Dewatering under Electro-Osmotic Pulse Technology

  • Kim, Jitae;Lee, Jeongwoo;Chung, Il-Moon
    • 지질공학
    • /
    • 제30권4호
    • /
    • pp.423-433
    • /
    • 2020
  • Direct current (DC) electric fields have been used for electro-osmotic dewatering. Under DC conditions, however, the electrical contact resistance between the electrode and the dewatering material increases considerably during the process of dewatering. Such a circumstance hinders the continuation of effective electro-osmotic dewatering. To reduce this hindrance, an applied pulse electric field with periodic reversals of the electrode polarity should improve electro-osmotic dewatering. In this study, electro-osmotic dewatering under pulse conditions was experimentally investigated for electrode polarity reversals. During the dewatering process, the pulse electric field was able to reduce the hindrance caused by the DC, resulting in an increased final dewatered amount relative to that under a DC electric field. For a constant applied voltage, the reversed polarity condition, under which the electric current passing through the material was almost unchanged with time, yielded the maximum final dewatered amount. This technique can be used to enhance drainage from a water storage facility during a period of extreme drought and the seawater desalination plants using reverse osmosis in drought stricken coastal regions.

법규에 따른 자원회수시설의 건축적 형태에 관한 연구 - 서울과 도쿄를 중심으로 - (A Study on Architectural Form of Waste to Energy Plants in accordance with Law - Focus on Seoul and Tokyo -)

  • 정승원;이강준
    • 도시과학
    • /
    • 제11권1호
    • /
    • pp.29-35
    • /
    • 2022
  • Waste to Energy Plant were recognized as hateful facilities, and there were many conflicts in the location due to social problems such as the NIMBY phenomenon due to problems such as damage to property in the surrounding area, odor, and image loss. Problems such as air pollution and odor are solved by the development of advanced prevention facilities such as electric dust collectors, wet cleaning systems, semi-dry reaction towers, bag filters, and catalyst towers (SCR: Selective Catalytic Reduction), and air recycling facilities in waste storage tanks. However, it is being avoided because of the perception that it is an incinerator. To resolve these conflicts, the government installs and operates resident convenience facilities to compensate residents near resource recovery facilities, provides green space and improves the environment, and supports heating expenses in accordance with the 「Waste Treatment Facility Support Act」. The purpose of this study is to derive implications through the analysis of domestic and overseas case studies for resident convenience facilities and environment improvement for the promotion of local communities in resource recovery facilities and use them as basic data for community promotion and environmental improvement when installing resource recovery facilities in the future.

정상운반조건 해석을 위한 사용후핵연료집합체 유한요소모델 최적화 (Optimization of Spent Nuclear Fuel Assembly Finite Element Model for Normal Transportation Condition Analysis)

  • 김민식;박민정;장윤석
    • 한국압력기기공학회 논문집
    • /
    • 제19권2호
    • /
    • pp.163-170
    • /
    • 2023
  • Since spent nuclear fuel assemblies (SFA) are transported to interim storage or final disposal facility after cooling the decay heat, finite element analysis (FEA) with simplification is widely used to show their integrity against cladding failure to cause dispersal of radioactive material. However, there is a lack of research addressing the comprehensive impact of shape and element simplification on analysis results. In this study, for the optimization of a typical pressurized water reactor SFA, different types of finite element models were generated by changing number of fuel rods, fuel rod element type and assembly length. A series of FEA in use of these different models were conducted under a shock load data obtained from surrogate fuel assembly transportation test. Effects of number of fuel rods, element type and length of assembly were also analyzed, which shows that the element type of fuel rod mainly affected on cladding strain. Finally, an optimal finite element model was determined for other practical application in the future.

국제핵융합실험로 삼중수소 연료주기 (Tritium Fuel Cycle of the International Thermonuclear Experimental Reactor)

  • 송규민;손순환;정흥석;윤세훈;정기정
    • Korean Chemical Engineering Research
    • /
    • 제50권4호
    • /
    • pp.595-603
    • /
    • 2012
  • 국제핵융합실험로(ITER)가 2019년까지 7개국의 공동개발사업으로 건설될 예정이다. ITER의 핵융합연료주기는 핵융합진공용기, 삼중수소 플랜트, 연료공급부로 구성되어 있다. 이중에서 삼중수소 플랜트는 핵융합연료주기를 위한 중 수소와 삼중수소의 저장, 공급, 분리, 제거, 회수 등의 기능을 제공한다. 삼중수소 플랜트는 외부에서 중수소와 삼중수소를 공급받아 저장 공급하는 SDS, 토카막배출처리의 TEP, 수소동위원소 분리의 ISS, 삼중수소수 및 대기 처리의 WDS ADS, 정성 정량분석의 ANS 등으로 구성된다. 이 논문에서는 삼중수소 플랜트를 구성하는 주요 공정에 대한 기능 및 설계요건을 기술하였다. 한국은 SDS 개발에 참여하고 있으며 월성원전 삼중수소 제거설비(WTRF) 건설 및 운전경험을 통해 WDS 대한 기술을 일부 확보하였다. 향후 ISS 및 TEP에 대한 기술확보를 위한 여러 분야에서의 참여 확대를 기대하고 있다.

부산 일부 지역의 어린이 급식시설에 대한 어린이급식관리지원센터의 위생.안전 관리 지원 효과 (Effects of Food Safety Management Support of Center for Children's Foodservice Management on Foodservice Facilities for Children in Busan Area)

  • 김성혜;오은영;한진숙
    • 동아시아식생활학회지
    • /
    • 제24권2호
    • /
    • pp.261-274
    • /
    • 2014
  • The purpose of this study was to examine the effects of food safety management support in the Center for Children's Foodservice Management (CCFSM) on foodservice facilities for children in Busan area. We assessed the status of hygiene and safety practices of institutional and non-institutional foodservice on a quarterly basis by using an inspection checklist for food hygiene and safety developed by dieticians from February to December in 2013. The subjects were 103 children's foodservices, including 37 institutional and 66 non-institutional foodservices. Inspection checklist consisted of nine categories with 39 checklists; general characteristics, personal hygiene, ingredient control, menu planning, cooking processing control, serving management, washing, disinfection and storage control, and environment and safety management. The average score of each field (pre-supporting/post-supporting) in institutional foodservice was 0.56/0.92 for personal hygiene, 0.55/0.87 for ingredient control, 0.76/0.97 for menu planning, 0.53/0.89 for processing control, 0.27/0.67 for serving management, 0.47/0.91 for washing, disinfection and storage control, and 0.61/0.91 for environment management and 0.64/0.94 for safety management. In non-institutional foodservice, the average score of each field (pre-supporting/post-supporting) was 0.49/0.80 for personal hygiene, 0.52/0.75 for ingredient control, 0.78/0.97 for menu planning, 0.42/0.76 for processing control, 0.32/0.61 for serving management, 0.57/0.88 for washing, disinfection and storage control, and 0.46/0.82 for environment management and 0.73/0.88 for safety management. The average scores of all categories (pre-supporting/post-supporting) were 0.57/0.91 in institutional foodservice and 0.53/0.82 in non-institutional foodservice. The effects of management support in CCFSM on institutional foodservice were higher than those of non-institutional foodservice. Based on these results, we found that management support in CCFSM on foodservice facilities for children had a significantly positive effect on status of hygiene and safety practice regardless of foodservice facility size.

Exploring the feasibility of Salmonella Typhimurium-specific phage as a novel bio-receptor

  • Choi, In Young;Park, Do Hyeon;Chin, Brayan A.;Lee, Cheonghoon;Lee, Jinyoung;Park, Mi-Kyung
    • Journal of Animal Science and Technology
    • /
    • 제62권5호
    • /
    • pp.668-681
    • /
    • 2020
  • The purpose of this study was aimed to isolate a Salmonella Typhimurium-specific phage (KFS-ST) from washing water in a poultry processing facility and to investigate the feasibility of the KFS-ST as a novel bio-receptor for the magnetoelastic (ME) biosensor method. KFS-ST against S. Typhimurium was isolated, propagated, and purified using a CsCl-gradient ultracentrifugation. Morphological characteristics of KFS-ST were analyzed using transmission electron microscopy (TEM). Its specificity and efficiency of plating analysis were conducted against 39 foodborne pathogens. The temperature and pH stabilities of KFS-ST were investigated by the exposure of the phage to various temperatures (-70℃-70℃) and pHs (1-12) for 1 h. A one-step growth curve analysis was performed to determine the eclipse time, latent time and burst size of phage. The storage stability of KFS-ST was studied by exposing KFS-ST to various storage temperatures (-70℃, -20℃, 4℃, and 22℃) for 12 weeks. KFS-ST was isolated and purified with a high concentration of (11.47 ± 0.25) Log PFU/mL. It had an icosahedral head (56.91 ± 2.90 nm) and a non-contractile tail (225.49 ± 2.67 nm), which was classified into the family of Siphoviridae in the order of Caudovirales. KFS-ST exhibited an excellent specificity against only S. Typhimurium and S. Enteritidis, which are considered two of the most problematic Salmonella strains in the meat and poultry. However, KFS-ST did not exhibit any specificity against six other Salmonella and 27 non-Salmonella strains. KFS-ST was stable at temperature of 4℃ to 50℃ and at pH of 4 to 12. The eclipse time, latent time, and burst size of KFS-ST were determined to be 10 min, 25 min and 26 PFU/ infected cell, respectively. KFS-ST was relatively stable during the 12-week storage period at all tested temperatures. Therefore, this study demonstrated the feasibility of KFS-ST as a novel bio-receptor for the detection of S. Typhimurium and S. Enteritidis in meat and poultry products using the ME biosensor method.

조사 대상 부지 신규 분류 체계 제안 및 개황조사 강화를 통한 토양정밀조사 방법 개선 연구 (Improvement of Detailed Soil Survey Guidance through the New Site Classification System and Reinforcement of Exploratory Soil Survey)

  • 권지철;이군택;황상일;김태승;윤정기;김지인
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제20권7호
    • /
    • pp.53-60
    • /
    • 2015
  • This study suggested the new site classification system according to land use, type of contamination and contaminants. Because the present site classification system can not cover all the areas, we changed the concept of land use to more detail one and enlarged the concept of other areas to cover all the areas not defined as certain land use. In case of the present industrial area, it was merged as other areas to avoid the confusion with oil and toxic material storage tank farm area. Accident area was separated from other areas and defined as only accident area caused by the mobile storage facility. In addition to classify the sites according to the basic land use, we classify the sites again in lower level according to the type of contamination and contaminants. With this classification system, we proposed different soil sampling strategy with the consideration of the origin of contamination and the interactions between soil and contaminants. We removed the surface soil sample (0~15 cm depth) around above storage tank because it was not a effective sample to assess whether that area contaminated or not. We also proposed to take the deeper soil samples at minimum three sampling points to confirm the depth of contamination in exploratory soil survey. We also proposed to remove the one point of 15 m depth sampling because it is not effective to confirm contaminated soil depth and needs the exhausted labor and cost. Instead of doing this, we added the continuous sampling to uncontaminated subsoil. Soil sampling points and depth in detailed soil survey is determined based on the results of exploratory soil survey. Therefore, effectiveness and reinforcements of exploratory soil survey would play an important role in improving the reliability of detailed soil survey.

음식물류폐기물 처리시설에서의 악취발생 특성 및 관리방안 (The Characteristic and Management of Odor Emitted from Foodwaste Treatment Facility)

  • 유승성;김영두;이준연;차영섭;김은숙;전재식;선우영;엄석원;채영주
    • 환경영향평가
    • /
    • 제21권3호
    • /
    • pp.353-365
    • /
    • 2012
  • This study is understanding characteristics and analyzing contributions of the odor causing compounds of complex-odor & major specified odor materials, and contribution analysis, caused pre-treatment facilities(input and storage) and post-treatment facilities(heating and drying). The target of this study is feeds-production-facilities, located in Seoul. The averaged complex-odor compounds on the boundary line is 21 times higher, and it is 15 times higher than emission standards. In cracking&collection(pre-treatment facilities), the concentration of compounds is 4,881 times, 2,080 times in drying, and 1,442 times in putting&storing facilities. Ammonia occupies the largest portion of the results of monitoring specified odor compounds in input&storage facilities, followed Acetaldehyde > Hydrogen sulfide > Methyl mercaptan. In cracking&collection, Ammonia also occupies most of odor compounds, followed Methyl mercaptan > Acetaldehyde > Dimethyl disulfide > Dimethyl sulfide > Hydrogen sulfide. Acetaldehyde > Methyl mercaptan in drying facilities. On the boundary line, however, the concentration of specified odor compounds stays below emission standards. The result of contribution analysis is that methyl mercaptan has the highest contribution in input & storage, as well as cracking&collection facilities, followed Acetaldehyde > Hydrogen sulfide > Dimethyl sulfide > Dimethyl disulfide. In the drying facilities, the contribution shows Methyl mercaptan > Acetaldehyde > i-Valeraldehyde and Butyraldehyde. Therefore, to decrease odor in foodwaste treatment facilities, proper prevention facilities need to be installed and operated, according to characteristics of individual odor compounds, based on monitored data.

B형 삼중수소 운반용기 안정성 평가 (Safety evaluation of type B transport container for tritium storage vessel)

  • 이민수;백승우;김광락;안도희;임성팔;정홍석;최희주;최종원;손순환;송규민
    • 방사성폐기물학회지
    • /
    • 제5권2호
    • /
    • pp.155-169
    • /
    • 2007
  • 월성 원자력 발전소의 TRF 시설에서 수집된 트리튬을 metal hydride 형태로 보관하고 있는 500 kCi급 트리튬 1차 저장용기를 발전소 밖의 폐기물 저장고로 안전하게 운반하기 위하여 트리튬 운반용기를 개발하였다. B형 운반용기의 기술기준을 적용하여 구조평가, 열평가, 방사선차폐평가, 격납평가 등을 수행하여 운반용기의 안전성을 분석하였다. 트리튬 운반용기는 정상운반조건 및 사고운반조건에서도 격납 경계가 손상되지 않는다고 평가되었다. 붕괴열로 인한 운반용기 내부 저장용기의 온도상승은 수치해석 결과, 원통형 모델에서는 $134.8^{\circ}C$로 나타났다. 운반사고 조건에 대한 열 평가로서 $800^{\circ}C$ 외부환경에 30분간 노출되었을 경우에는 단열재만의 열차폐를 고려하여 계산한 결과, 약 $405^{\circ}C$로 나타났으며, 내부 온도 상승은 1차 격납 경계인 1차 저장용기의 허용 온도인 $550^{\circ}C$에도 미치지 못하였다. 격납 차폐 평가에서도 사고조건인 $800^{\circ}C$의 외부 환경에 노출된 경우에서도 충분히 운반용기의 격납 성능을 유지할 수 있다고 판단되었다. 방사선에 대한 차폐 특성을 조사한 결과, 트리튬에서 발생된 ${\beta}-ray$ 선량은 1차 저장용기 외부 표면에서 0으로 계산되었다. 이상과 같이 500 kCi 급 트리튬 운반용기에 대한 안전성을 평가한 결과, 운반사고조건에서도 트리튬 운반용기는 전혀 이상이 없는 것으로 나타났다.

  • PDF

의료용 방사성폐기물 자체처분 가이드라인에 관한 고찰 (Discussion about the Self Disposal Guideline of Medical Radioactive Waste)

  • 이경재;설진형;이인원;박영재
    • 핵의학기술
    • /
    • 제21권2호
    • /
    • pp.13-27
    • /
    • 2017
  • 국내 의료용 방사성폐기물 자체처분과 관련하여 심사과정에서 많은 보완을 거치게 되고, 이 과정을 통과함에 많은 어려움을 겪고 있다. 이에 따라 의료용 방사성폐기물의 자체처분시 기본적인 가이드라인을 제시함으로써 의료기관의 방사성 폐기물 처리효율을 높이고자 한다. 2015년부터 2016년까지 국내 15개 의료기관의 의료용 방사성폐기물 자체처분 절차서 및 계획서 작성 시 보완 요청된 사항들을 비교 검토하였으며, 이와 관련하여 원자력 안전법 관련 규정을 기준으로 방사성폐기물 자체처분 시 서류작성에 필요한 세부 작성안 들을 도출하였다. 한국원자력안전기술원의 대표적인 보완요청사항들로는 비가연성 폐기물의 처분방법, 자체처분 예정 폐기물의 저장방법, 폐기물 자체처분의 정당성 및 자체처분 전 조치사항, 배기필터의 기준방사능 및 보관기간 산출, 폐기물 수량 측정 용기 보유 여부 및 증빙자료, 감마카운터 사용 시 측정효율 증명자료 첨부임을 확인할 수 있었다. 또한 의료 방사성 폐기물 자체처분 가이드라인 구축을 통해 방사성동위원소 핵종 및 발생유형별 분류기준 등을 명확히 제시하였다. 이를 통해, 자체처분 서류 작성에 따른 시간의 단축과 업무대행 지출비용이 발생되지 않음을 확인할 수 있었고 방사성 폐기물의 장기간 보관에 따른 보관시설의 저장효율이 좋아지고 경제적 비용도 절감됨을 알 수 있었다. 본 가이드라인을 바탕으로 방사성폐기물 자체처분의 실무적인 어려움을 겪고 있는 관계자들의 업무효율 향상에 기여할 것으로 사료된다.

  • PDF