• Title/Summary/Keyword: storage facility

Search Result 616, Processing Time 0.021 seconds

Evaluation Study of Blast Resistance and Structural Factors in the Explosive Simple Storage by Numerical Analysis (수치해석을 통한 화약류 간이저장소의 방폭성 및 구조인자 평가연구)

  • Jung, Seung-Won;Kim, Jung-Gyu;Kim, Jun-Ha;Kim, Nam-Soo;Kim, Jong-Gwan
    • Tunnel and Underground Space
    • /
    • v.32 no.2
    • /
    • pp.160-172
    • /
    • 2022
  • The design regulations for simple explosive storage in Korea only stipulate standards for the materials and thickness of the wall of the structure because the amount of explosives that can be stored is small. There is concern about secondary damage during an internal explosion in a simple storage facility, and it is necessary to reexamine the current standards. The numerical analysis for the TNT 15 kg explosion inside the simple storage was carried out by setting the factors using the robust experimental design method. The displacement of the structure generated under the same time condition was analyzed, and the contribution was evaluated. The contribution of concrete thickness was the highest, and the contribution of concrete strength and rebar arrangement was lower than that of concrete thickness. The reinforcement diameter contributed extremely little to the displacement. The structural standards of the simple storage that are currently applied are insufficient on blast resistance, and it is necessary to present new design standards. Therefore, the design factor to be applied later analysis and actual experiments were taken into consideration. For the design variables, the thickness of the concrete was 15 cm considering the displacement, the concrete strength was selected as general concrete considering the inlet discharge pressure, the factor with the lowest average displacement was selected for the reinforcement arrangement and the diameter of the reinforcement, the factor with the smallest level was selected in consideration of economic feasibility because the difference in displacement was low.

Development of Operation Scenarios by HILS for the Energy Storage System Operated with Renewable Energy Source (HILS를 이용한 신재생 에너지원이 포함된 에너지 저장시스템의 운영 시나리오 개발)

  • Shin, Dong-Cheol;Jeon, Jee-Hwan;Park, Sung-Jin;Lee, Dong-Myung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.2
    • /
    • pp.224-232
    • /
    • 2018
  • According to government policy, renewable energy facility such as solar power generation is being implemented for newly constructed buildings. In recent years, the introduction of Energy Storage System (ESS) served as an emergency power for replacing an existing diesel generator has been increasing. Furthermore, in order to expand the efficacy of the ESS operation, operation in combination with renewable energy sources such as solar and wind power generation is increasing. Hence, development of the ESS operation algorithms for emergency mode as well as the peak power cut mode, which is the essential feature of ESS, are necessary. The operational scenarios of ESS need to consider load power requirement and the amount of the power generation by renewable energy sources. For the verification of the developed scenarios, tests under the actual situation are demanded, but there is a difficulty in simulating the emergency operation situation such as system failure in the actual site. Therefore, this paper proposes simulation models for the HILS(Hardware In the Loop Simulation) and operation modes developed through HILS for the ESS operated with renewable energy source under peak power reduction and emergency modes. The paper shows that the ESS operation scenarios developed through HILS work properly at the actual site, and it verifies the effectiveness of the control logic developed by the HILS.

An Analysis of Container Logistics System by Computer Simulation (시뮬레이션에 의한 컨테이너 물류시스템의 분석에 관하여(BCTOC를 중심으로))

  • 유승열;여기태;이철영
    • Journal of the Korean Institute of Navigation
    • /
    • v.21 no.1
    • /
    • pp.1-11
    • /
    • 1997
  • Because of the sharp increase of its export and import container cargo volumes contrast to the lack of related Container Terminal facility, equipment and inefficient procedure, there is now heavy container cargo congestions in Pusan Container Terminal. As a result of such a situation, many container ships avoid their calls into Pusan port. This is a major cause that in tum kads to weakening intemational competitiveness of the Korean industry. This study, therefore, aims are to make a quantitative analysis of Container Terminal System through the computer simulation, especially focusing on its 4 sub-system of a handling system, 'it is checked whether the current operation is being performed effectively through the computer simulation. The overall findings are as folIows; Firstly, average tonnage of the ships visiting the BCTOC was 32,360 G/T in from January '96, to may '96. The average arrival interval and service time of container ships at BCTOC are 5.63 hours and 18.67 hours respectively. Ship's arrival and service pattern at BCTOC was exponential distribution with 95% confidence and Erlang-4 distribution with 99% confidence. Secondly, average waiting time and number of ships was 9.9 hours, 235 ships(38%) among 620 ships. Number of stevedoring container per ship was average 747.7 TED, standard deviation 379.1 TEU and normal distribution with 99% confidence. Thirdly, from the fact that the average storage days of containers at BCTOC are 2.75 days (3.0 days when import, 2.5 days when export). it is founds that most containers were transfered to the off-dock storage areas with the free periods(5 days when import, 4 days when export), the reason for which is considered to be the insufficient storage area at BCTOC. Fourthly, in the case of gate in-out at BCTOC, occupied containers and emptied containers are 89% and 11% respectively in the gate-in, 75% and 25% seperately in the gate-out. Finally, from the quantitative analysis results for container terminal at BCTOC, ship's average wating time of ships was found to be 20.77 hours and berth occupancy rate(${\rho}$) was 0.83. 5~6 berths were required in order that the berth occupancy rate(${\rho}$) may be maintained up to 60% degree.

  • PDF

Survey on Condominium Apartment Dwellers' Consciousness of Unit Plan in Daejeon City (대전지역 아파트 단위주호 계획에 대한 거주자의 주거의식에 관한 조사연구)

  • Choi, Byung-Sook;Kang, In-Ho;Park, Jung-A;Jung, Mi-Hyeon;Jang, Hye-Sun
    • Journal of the Korean housing association
    • /
    • v.20 no.5
    • /
    • pp.31-39
    • /
    • 2009
  • The purpose of this study was to find out the residents' consciousness of the unit plan on condominium apartment and to contribute to develop a condominium apartment unit plan in Daejeon City. This research was performed by a questionnaire survey method, 464 data was collected from apartment residents lived in about $85\;m^2$ unit with 3 rooms and the apartments was limited to the complexes within 1-4 years of the length of building at Yuseong-gu and Seo-gu. By analyzing those data, findings are as follows: 1) Residents thought living room, kitchen and bathroom were importment space in a unit plan. They needed a storage function in an entrance and a intermediate room, and Anbang(mater bedroom) so did. 2) L-DK plan type was very popular and the type of front DK with L on the floor plan was preferred. This was unique results. 3) Sub-kitchen was needed for a refrigerator of Kimchi, the location of it was related to a main kitchen and a utility. the third room was needed for library, home office and storage space. 3) Bath-tub in An-bang and showe-booth in public bathroom was preferred. This was same to the popular trend of Korean condominium apartment. 4) The enlargment remodeling of balcony was showed livingroom balcony or personal bedrooms at the time of occupancy. They needed the balcony near a kitchen or an utility to equip a storage facility. Additionally, residents were preferred to their taste rather than a choice of interior concept package services.

Simulation Analysis for Improving the Logistics Flow in an Chemical Storage System (석유화학 창고 시스템 내 물류 흐름 개선을 위한 시뮬레이션 분석)

  • Lee, Gi-Hwan;Jo, Jae-Young;Chae, Gyu-Tae;Jang, Seong-Yong
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.43 no.3
    • /
    • pp.77-86
    • /
    • 2020
  • In this study, to improve the logistics flow of existing given chemical logistics warehouse, four logistics flow alternatives were proposed to minimize truck interference by building simulation model. The simulation model for chemical storage warehouse was built to evaluate system performance. Among the four new improved alternatives based on the basic model, the model with the same truck's pathways and locations of facilities identified an increase in the number of interferences but a decrease in daily working hours as the number of resources in a particular facility increases. Therefore, the three groups were classified as 'efficiency', 'complementary', and 'safety' based on the daily working hours, and the ratio of trucks entering two types of logistics warehouse was set in consideration of future market fluctuations. For each of the six types, the optimal number of resources was selected as the number of resources in the facilities with the least number of interferences in the basic model and the evaluation measures and characteristics set in this study were compared and analyzed. As a result, the Alternative 4 model operating the underground roadway produced interference between 17.0% and 36.4% of the basic model, with 113.3% of the interior loadspace.

Economy Analysis and Optimized Capacity Evaluation of Photovoltaic-Related Energy Storage System (태양광 에너지저장장치(ESS) 경제성 분석 및 최적 용량 평가)

  • Lee, Young-Hun;Sung, Tae-Hyun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.2_2
    • /
    • pp.209-218
    • /
    • 2022
  • The purpose of this study is to analyze an economic assessment of PV-ESS systems based on the power generation performance data of solar power (PV) operating in domestic area, and to calculate the optimal capacity of the energy storage system. In this study, PVs in Gyeonggi-do, Jeollabuk-do, and Gyeongsangbuk-do were targeted, and PVs in this area were assumed to be installed on a general site, and the research was conducted by applying weights based on the facility's capacity. All the analysis was conducted using the actual amount of KPX transactions of PVs in 2019. In order to calculate the optimal capacity of PCS and BESS according to GHI, PV with a minimum/maximum/central value was selected by comparing the solar radiation before the horizontal plane between three years (2017-2019) of the location where PV was installed. As a result of the analysis, in Gyeonggi-do, if the REC weight decreases to 3.4 when there is no change in the cost of installing BESS and PCS, it is more economical to link BESS than PV alone operation of PV. In Jeollabuk-do, it was analyzed that if the REC weight was reduced to 3.6, it was more likely to link BESS than PV operated alone. In Gyeongsangbuk-do, it was analyzed that if the REC weight was reduced to 3.4, it was more likely to link BESS than PV operated alone.

A Study on the Space Composition for Department of Kidney Dialysis in Regional Public Hospital(1) (지역거점 공공병원의 인공신장부 공간구성에 관한 연구(1))

  • Chai, Choul Gyun;Park, Kyeong Hyeon
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.28 no.2
    • /
    • pp.31-38
    • /
    • 2022
  • Purpose: This study presents the results of the analysis on space utilization of kidney dialysis units in regional public hospitals, which plays a key role in local public medical services. The result aims to achieve safety from infection, allow comfort for the dialysis environment, and stability for medical support. The purpose of this study is to present fundamental data for architectural plans for the kidney dialysis unit, as well as to alleviate potential infectious diseases such as COVID-19. Methods: For research purposes, the investigation and analysis of space utilization were based on architectural floor plans, research papers and literature, related legal systems, and public statistics. Of the main 35 regional public hospitals, in regards to data accessibility, 15 facilities were selected to conduct the survey and analysis for the objective. Results: The space composition by area research results of kidney dialysis units in public hospitals are as follows: Firstly, most targets do not have required rooms in the access and support area, except for the hemodialysis beds in the treatment section. Secondly, the access area requires necessary room and space design that took into consideration of convenience and accessibility for patients. Thirdly, in regards to infection prevention and control, proper circulation and room plan is essential for storage and disposal of contaminated products and linen after use. For the treatment area, the arrangement plan needs to establish a visual connection between the isolation room, the nursing station, and the bed area. Additionally, consideration of circulation in the preparation, treatment, observation, examination, and all other rooms in the facility is required. Lastly, for the support area, the room is designed to consider adequate working and meeting spaces for the medical staff, consultation space for patients or guardians, separate storage and disposal of clean and contaminated items, and the storage of various equipment for dialysis. Implications: In preparation for the increase in chronic kidney failure patients and the spread of infectious diseases, such as COVID-19, the researched data demonstrates the basic guidelines for space composition of kidney dialysis units and the significant role of regional public hospitals.

Analysis of Safety Regulation and Chemical Reactivity of Hypergolic Propellant (접촉점화성 추진제 안전기준 및 상호반응성 분석)

  • Eungwoo Lee;Ahntae Shin;Sangyeon Cho;Byeongmun Park
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.3
    • /
    • pp.108-115
    • /
    • 2023
  • Although hydrazine is an excellent liquid propellant, caution is required during storage and handling due to its high toxicity and reactivity. Safety guidelines should be established in consideration of the chemical reactivity by unintended leakage. In this study, the status of hydrazine facilities at launch site and safety standards for storing and handling were investigated and then, the reactivity between chemicals and hydrazine was analyzed. As a result of the analysis, hydrazine has reactivity with the exception of fuel oil. This paper emphasizes the imperative nature of constructing a dedicated hydrazine storage facility. Ensuring compatibility between hydrazine and the materials used in storage containers and handling equipment is crucial to prevent undesired reactions that could compromise safety. It was intended to be used as basic data to secure the range safety when handling hydrazine.

Seismic Behavior Characteristics of Ground Storage Circular Tanks and Proposal of Performance-based Seismic Design Method (평저형 원형 저장탱크의 지진거동 특성 및 성능기반 내진설계법 제안)

  • Han dong yun;Sun chang ho;Kim ick hyun;Nam, hyung mo
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.4
    • /
    • pp.34-42
    • /
    • 2023
  • Considering the contribution of industrial facilities to the national economy, securing operability against earthquakes is very important. However, the basic concept of current seismic design mainly allows ductile behavior of facilities against large-scale earthquakes and only considers structural safety for the purpose of preventing collapse. In order to secure the operability of industrial facilities, the level of seismic performance to maintain operability may vary depending on the structural behavior characteristics of the industrial facility, and a seismic design method is needed to satisfy this. In this study, a ground storage tanks Nonlinear seismic behavior characteristics(R-μ-T) were analyzed through nonlinear response history analysis, and based on this, a new reliability-based, performance-based seismic design method was proposed.

Economic analysis of irrigation facilities for securing water for field crops

  • Hyung Jin Shin;Jae Young Lee;Jae Nam Lee;Han Na Lee;Sang Hyeon Park;Bum Soo Shin;Sang Sun Cha;Se Myung Kwon;Jung Il Seo;Chan Gi Park
    • Korean Journal of Agricultural Science
    • /
    • v.50 no.4
    • /
    • pp.785-798
    • /
    • 2023
  • Considering irrigation facilities are currently insufficient and drought vulnerability due to climate change is high, efficient measures are required to secure water supply for field crops. This study, therefore, calculated the water shortage to secure water for representative field crops. An economic analysis was further conducted by comparing the production income to the input cost for each method. Here, five distinct regions were selected to represent each crop-Cheongyang-gun for chili peppers, Yesan-gun for apples, Dangjin-si for cabbages, Seosan-si for garlic, and Goesan for beans. The regions with insufficient water supply were estimated by calculating the water requirements and the supplied water from public groundwater wells for each area. A comprehensive set of four scenarios was presented as a strategy to ensure water security and manage irrigation facilities. These scenarios comprised the maintenance of existing groundwater wells, the construction of new water storage tanks, the installation of additional groundwater wells, and the utilization of surface water. B/C (benefit/cost) analysis was conducted for each scenario. As a result, the construction of water storage tanks was selected as a facility and water management plan in Cheongyang-gun, Dangjin-si, and Seosan-si. The analysis additionally indicated the economic viability of installing surface water utilization facilities in Yesan-gun and developing water storage tanks and groundwater (aquifer) wells in Goesan-gun. The results of this study are considered to serve as foundation data that may be utilized in the selection of water management plans for drought-prone areas in the future.