• Title/Summary/Keyword: storage facility

Search Result 603, Processing Time 0.023 seconds

Risk Factor Analysis for Preventing Foodborne Illness in Restaurants and the Development of Food Safety Training Materials (레스토랑 식중독 예방을 위한 위해 요소 규명 및 위생교육 매체 개발)

  • Park, Sung-Hee;Noh, Jae-Min;Chang, Hye-Ja;Kang, Young-Jae;Kwak, Tong-Kyung
    • Korean journal of food and cookery science
    • /
    • v.23 no.5
    • /
    • pp.589-600
    • /
    • 2007
  • Recently, with the rapid expansion of the franchise restaurants, ensuring food safety has become essential for restaurant growth. Consequently, the need for food safety training and related material is in increasing demand. In this study, we identified potentially hazardous risk factors for ensuring food safety in restaurants through a food safety monitoring tool, and developed training materials for restaurant employees based on the results. The surveyed restaurants, consisting of 6 Korean restaurants and 1 Japanese restaurant were located in Seoul. Their average check was 15,500 won, ranging from 9,000 to 23,000 won. The range of their total space was 297.5 to $1322.4m^2$, and the amount of kitchen space per total area ranged from 4.4 to 30 percent. The mean score for food safety management performance was 57 out of 100 points, with a range of 51 to 73 points. For risk factor analysis, the most frequently cited sanitary violations involved the handwashing methods/handwashing facilities supplies (7.5%), receiving activities (7.5%), checking and recording of frozen/refrigerated foods temperature (0%), holding foods off the floor (0%), washing of fruits and vegetables (42%), planning and supervising facility cleaning and maintaining programs of facilities (50%), pest control (13%), and toilet equipped/cleaned (13%). Base on these results, the main points that were addressed in the hygiene training of restaurant employees included 4 principles and 8 concepts. The four principles consisted of personal hygiene, prevention of food contamination, time/temperature control, and refrigerator storage. The eight concepts included: (1) personal hygiene and cleanliness with proper handwashing, (2) approved food source and receiving management (3) refrigerator and freezer control, (4) storage management, (5) labeling, (6) prevention of food contamination, (7) cooking and reheating control, and (8) cleaning, sanitation, and plumbing control. Finally, a hygiene training manual and poster leaflets were developed as a food safety training materials for restaurants employees.

Foodservice Operational System and Satisfaction of Customers with Foodservice at Youth Facilities (청소년수련시설 급식소의 운영실태 및 이용자의 급식만족도)

  • Lee, Hyun Ju;Lee, Young Eun;Park, Eun Hye
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.44 no.9
    • /
    • pp.1374-1387
    • /
    • 2015
  • The purpose of this paper was to investigate the operational status of youth facilities as well as the degree of students' satisfaction with menus served at youth facilities. The survey was conducted from July 9 to July 31, 2013 using questionnaires. The responses of 55 youth facilities and 249 students who had experienced foodservice at youth facilities were analyzed, utilizing the SPSS V20.0 program. The results on management status of youth facilities were as follows: 41.8% of youth facilities were operated for over 10 years, and 45.5% of facilities served meals for 100 to 200 students per day on average. Meal costs were 4,450 won on average, and food costs accounted for 46.8% of average meal costs. Exactly 78.2% of facilities preserved storage type meals at a temperature under -18 degrees Celsius for more than 144 hours, as the 'Food Sanitation Act' stated. Exactly 12.7% of facilities did not hire professional dietitians and had unsupervised foodservice management. Among 19 kitchen equipments surveyed in this research, Combi steamer was the least frequent at youth facilities. According to the results, most students (38.7%) ate leftovers since the food was not tasty. Overall foodservice satisfaction was on average 3.45 points, and the four factors 'dining room sanitation' (P<0.05), 'food taste' (P<0.01), 'serving various desserts' (P<0.01) and 'temperature of dining room' (P<0.05), significantly affected overall satisfaction. As food taste was critical for customer satisfaction, it is important for each dietitian to consider customers' preferences and develop recipes and menus. Further, detailed regulation and precise guidelines for youth facility foodservice are required to enhance students' foodservice satisfaction and serve nutritionally balanced menus in a hygienic manner.

The Profile of Milling Plants in Korea (우리나라 양곡가공공장의 현황분석)

  • 정창주;금동혁;강화석
    • Journal of Biosystems Engineering
    • /
    • v.3 no.1
    • /
    • pp.47-63
    • /
    • 1978
  • This study was conducted to obtain a basic information necessary to assess present rice milling technology in Korea The profiles for milling plants was analyzed by survey work.For the private custom-work mills, which process about 80 percent of domestic rice consumption ,their actual milling test for the identical samples as used for filed mills was conducted. Two rice varieties Japonica and Tongil-type were associated with the experiments. The results are summarized as follows: 1. Analyses for private custom-work mills showed their general aspects as; about 91 percent of the mills belonged to an individual owner ship ; more than 93 percent of the mills was established earlier than 1950 ; about 80 percent of the mills was powered with electric motor; mills having less than two employees were about 75 percent; about 45 percent of the mills provided for warehouse in storing customers cereal grains. 2. The polishers installed in 1,255mills within the surveyed area (7 counties) have been supplied by 44 different domestic manufacturers ;in but about 60 percent of which was supplied by 6major manufacturers. The polishers could be classified into two categories in terms of principles of their polishing actions ;jet-pearler and friction types. About 51 percent of the mills was equipped with the former which has been recognized as giving greater milling recovery than the friction types. 3. Reason for owners of private mills to supplement new machines was due mainly to pgrading their mills to meet the requirements that established by the Government. However, about 60 percent of the mill owners intended to replace with new pearler by their own needs to meet with new high yielding varieties. 4. Processing systems of each previate rice mills surveyed could be classified into three categories, depending upon whether the systems posessed such components as precleaner and paddy separator or not. Only 36.7 percent of mills was installed with both precleanr ad paddy seperrator, 5.0 percent of mills did have neither percleaner nor paddy seperator, and rest of them equipped only one of the two. Hence,it is needed for about 63% of rice miils to be supplemented with these basic facilities to meet with the requirements for the standaized system. 5. Actual milling capacity measured at each field rice mills was shown a wide variation, having range from about 190 to 1,210 kg/hr. The percentages of mills classified according to daily milling capacity based on this hourly capacity were 24.3% for the capacity less than 3 M/T a day; 20.0% for 3-4 M/T; 15.6% for 4-5 M/T; 6.7% for 5-6 M/T; 22.3% for 6-7 M/T; and 11.0% for more than 7 M/T a day. 6. Actual amount of rice processed was about 310 M/T a year in average. About 42% of total milled rice was processed during October to Decembear, which formed a peak demand period for rice mills. The amount of rice milled during January to May was relatively small, but it had still a large amount compared to that during June to September. 7. Utilization rate of milling facility, i. e., percentage of the actual amount of milled rice to the capacity of rice mills, was about 18% on the year round average, about 41% in the peak demand season, and about 10% during June to September. Average number of operating days for mills surveyed was about 250 days a year, and about 21 days a month. 8. Moisture contents of paddy at the time of field mill tests were ranged 14.5% to 19.5% for both Japonica and Tong-i] varieties, majority of paddy grains having moisture level much higher than 1530. To aviod potential reduction of milling recovery while milling and deterioration of milled rice while storage due to these high grain mJisture contents, it may be very important for farmers holding rice to dry by an artificial drying method. 9. Milling recovery of JapJnica varieties in rice mills was 75.0% in average and it was widely ranged from 69.0% to 78.0 % according to mills. Potential increase in milJing recovery of Japonica variety with improvement of mill facilities was estimated to about 1.9%. On the other hand, milling recovery of Tong-il varieties in the field mill tests was 69.8% in average and it ranged from 62% to 77 %, which is much wider than that of Japonica varieties. It is noticed that the average milling recovery of Tong-il variety of 69.8% was much less than that of the Japonica-type. It was estimated th3.t up to about 5.0% of milling recovery for Tong-il variety could be improved by improving the present lo'.ver graded milling technology. 10. Head rice recoveries, as a factor of representing the quality of commercial goods, of Japonica and Tong-il varieties were 65.9% and 53.8% in average, and they were widely ranged from 52% to 73% and from 44% to 65% , respectively. It was assessed that head rice recovery of Japonica varieties can be improved up 3.3% and that of Tong-il varieties by 7.0% by improving mill components and systems.

  • PDF

Structural Safety Test and Analysis of Type IP-2 Transport Packages with Bolted Lid Type and Thick Steel Plate for Radioactive Waste Drums in a NPP (원자력발전소의 방사성폐기물 드럼 운반을 위한 볼트체결방식의 두꺼운 철판을 이용한 IP-2형 운반용기의 구조 안전성 해석 및 시험)

  • Lee, Sang-Jin;Kim, Dong-hak;Lee, Kyung-Ho;Kim, Jeong-Mook;Seo, Ki-Seog
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.5 no.3
    • /
    • pp.199-212
    • /
    • 2007
  • If a type IP-2 transport package were to be subjected to a free drop test and a penetration test under the normal conditions of transport, it should prevent a loss or dispersal of the radioactive contents and a more than 20% increase in the maximum radiation level at any external surface of the package. In this paper, we suggested the analytic method to evaluate the structural safety of a type IP-2 transport package using a thick steel plate for a structure part and a bolt for tying a bolt. Using an analysis a loss or dispersal of the radioactive contents and a loss of shielding integrity were confirmed for two kinds of type IP-2 transport packages to transport radioactive waste drums from a waste facility to a temporary storage site in a nuclear power plant. Under the free drop condition the maximum average stress at the bolts and the maximum opening displacement of a lid were compared with the tensile stress of a bolt and the steps in a lid, which were made to avoid a streaming radiation in the shielding path, to evaluate a loss or dispersal of radioactive waste contents. Also a loss of shielding integrity was evaluated using the maximum decrease in a shielding thickness. To verify the impact dynamic analysis for free drop test condition and evaluate experimentally the safety of two kinds of type IP-2 transport packages, free drop tests were conducted with various drop directions. For the tests we examined the failure of bolts and the deformation of flange to evaluate a loss or dispersal of radioactive material and measured the shielding thickness using a ultrasonic thickness gauge to assess a loss of shielding integrity. The strains and accelerations acquired from tests were compared with those by analyses to verify the impact dynamic analysis. The analytic results were larger than the those of test so that the analysis showed the conservative results. Finally, we evaluated the safety of the type IP-2 transport package under the stacking test condition using a finite element analysis. Under the stacking test condition, the maximum Tresca stress of the shielding material was 1/3 of the yielding stress. Two kinds of a type IP-2 transport package were safe for the free drop test condition and the stacking test condition.

  • PDF

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2010 (설비공학 분야의 최근 연구 동향 : 2010년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Lee, Dae-Young;Kim, Seo-Young;Choi, Jong-Min;Kim, Su-Min;Kwon, Young-Chul;Baik, Yong-Kyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.6
    • /
    • pp.449-469
    • /
    • 2011
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering during 2010. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends of thermal and fluid engineering have been surveyed as groups of general thermal and fluid flow, fluid machinery, and new and renewable energy. Various topics were presented in the field of general thermal and fluid flow. Research issues mainly focused on the thermal reliability of axial fan and compressor in the field of fluid machinery. Studies on the design of ground source heat pump systems and solar chemical reactors were executed in the field of new and renewable energy. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included heat transfer in thermoelectric cooling/power generation systems, combined heat and power systems, carbon nano fluid with PVP, channel filled with metal foam and smoke ventilation in a rescue station of a railroad tunnel. Also the studies on flow boiling of R123/oil mixture in a plain tube bundle and R410A charge amount in an air cooled mini-channel condenser were reported. In the area of industrial heat exchangers, researches on plate heat exchanger, shell and tube heat exchanger, enthalpy exchanger, micro channel PCHE were performed. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included heat transfer in thermoelectric cooling/power generation systems, combined heat and power systems, carbon nano fluid with PVP, channel filled with metal foam and smoke ventilation in a rescue station of a railroad tunnel. Also the studies on flow boiling of R123/oil mixture in a plain tube bundle and R410A charge amount in an air cooled mini-channel condenser were reported. In the area of industrial heat exchangers, researches on plate heat exchanger, shell and tube heat exchanger, enthalpy exchanger, micro channel PCHE were performed. (3) Refrigeration systems with alternative refrigerants such as hydrocarbons, mixed refrigerants, and CO2 were studied. Performance improvement of refrigeration systems are tried applying various ideas of refrigerant subcooling, dual evaporator with hot gas bypass control and feedforward control. The hybrid solar systems combining the solar collection devices with absorption chillers or compression heat pumps are simulated and studied experimentally as well to improve the understanding and the feasibility for actual applications. (4) Research trend in the field of mechanical building facilities has been found to be mainly focused on field applications rather than performance improvements. Various studies on heating and cooling systems, HVAC facilities, indoor air environments and energy resources were carried to improve the maintenance and management of building service equipments. In the field of heating and cooling systems, papers on a transformer cooling system, a combined heat and power, a slab thermal storage and a heat pump were reported. In the field of HVAC facilities, papers on a cooling load, an ondol and a drying were presented. Also, studies on HVAC systems using unutilized indoor air environments and energy resources such as air curtains, bioviolence, cleanrooms, ventilation, district heating, landfill gas were studied. (5) In the field of architectural environment and energy, studies of various purposes were conducted such as indoor environment, building energy, renewable energy and green building. In particular, renewable energy and building energy-related researches have mainly been studied reflecting the global interest. In addition, many researches which related the domestic green building certification of school building were performed to improve the indoor environment of school.

Effects of the Odor Abatement System in a Naturally Ventilated Growing Finishing Pig House (자연환기식 육성.비육돈사의 악취탈취장치 적용효과)

  • Lee, S.H.;Yun, N.K.;Kim, K.W.;Yum, S.H.;Cho, Y.H.
    • Journal of Animal Environmental Science
    • /
    • v.14 no.1
    • /
    • pp.31-38
    • /
    • 2008
  • Ammonia gas is one of the malodorous gases from swine production facilities, such as manure storage tank, manure fermentation facilities, and livestock houses, etc. Ammonia gas from swine house is being emitted at relatively low concentrations throughout the year. Therefore, livestock facilities were continuously ventilated to supply fresh air for respiration of the animals internal the livestock facilities. The swine facilities need very high ventilation rate to control the inside environmental conditions. The deodorization system of the livestock facilities must be developed considering the ventilation rates. The odor abatement system was installed in order to improve the internal environment of the naturally ventilated growing-finishing pig house. The system which distributes the deodorized air into inner space of the swine house by using plastic duct was installed. Since the internal environment, effected by the operation of the odor abatement system, is monitored by closing the winch curtain installed on the side wall of the pig house, the experiment was practiced at the season when the internal environment becomes aggravated, winter. The effects on the improvement in the internal environment of swine house by operating the odor abatement system are as follows ; 1. By re-distributing the air which was deodorized by the odor abatement system installed in the pig house, the result showed that the concentration of ammonia gas is decreased approximately 33.3% compared with that before operating odor abatement system. 2. The effect on the pig house's ammonia gas reduction was found that the ventilation rate was less than $0.5m^3$/min head. The effect of the operation of the odor abatement system showed to be scarce when the ventilation rate increases because of the influx of external fresh air makes the quantity of diluted air more than those of the odor abatement system. 3. The perishment rate of the pigs which were brooded until slaughtering decreased about 3.8% by operating the odor abatement system in the growing-finishing pig house. Also, after operating the odor abatement system, the stinging of the eyes, suspension dust, etc were decreased when going into swine house for management.

  • PDF

Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2011 (설비공학 분야의 최근 연구 동향: 2011년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Lee, Dae-Young;Kim, Seo-Young;Choi, Jong-Min;Paik, Yong-Kyoo;Kim, Su-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.6
    • /
    • pp.521-537
    • /
    • 2012
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2011. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends of thermal and fluid engineering have been surveyed as groups of fluid machinery and fluid flow, thermodynamic cycle, and new and renewable energy. Various topics were presented in the field of fluid machinery and fluid flow. Research issues mainly focused on the rankine cycle in the field of thermodynamic cycle. In the new and renewable energy area, researches were presented on geothermal energy, fuel cell, biogas, reformer, solar water heating system, and metane hydration. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer, nanofluids and industrial heat exchangers. Researches on heat transfer characteristics included heat transfer above liquid helium surface in a cryostat, methane hydrate formation, heat and mass transfer in a liquid desiccant dehumidifier, thermoelectric air-cooling system, heat transfer in multiple slot impinging jet, and heat transfer enhancement by protrusion-in-dimples. In the area of pool boiling and condensing heat transfer, researches on pool boiling of water in low-fin and turbo-B surfaces, pool boiling of R245a, convective boiling two-phase flow in trapezoidal microchannels, condensing of FC-72 on pin-finned surfaces, and natural circulation vertical evaporator were actively performed. In the area of nanofluids, thermal characteristics of heat pipes using water-based MWCNT nanofluids and the thermal conductivity and viscosity were measured. In the area of industrial heat exchangers, researches on fin-tube heat exchangers for waste gas heat recovery and Chevron type plate heat exchanger were implemented. (3) Refrigeration systems with alternative refrigerants such as $CO_2$, hydrocarbons, and mixed refrigerants were studied. Heating performance improvement of heat pump systems were tried applying supplementary components such as a refrigerant heater or a solar collector. The effects of frost growth were studied on the operation characteristic of refrigeration systems and the energy performance of various defrost methods were evaluated. The current situation of the domestic cold storage facilities was analyzed and the future demand was predicted. (4) In building mechanical system fields, a variety of studies were conducted to achieve effective consumption of heat and maximize efficiency of heat in buildings. Various researches were performed to maximize performance of mechanical devices and optimize the operation of HVAC systems. (5) In the fields of architectural environment and energy, diverse purposes of studies were conducted such as indoor environment, building energy, and renewable energy. In particular, renewable energy and building energy-related researches have mainly been studied as reflecting the global interests. In addition, various researches have been performed for reducing cooling load in a building using spot exhaust air, natural ventilation and energy efficiency systems.

Survey of Hygienic Condition and Management of Meat Markets in Seoul and Gyeong-Gi Area, Korea - HACCP-certified and Non Certified - (서울 및 경기지역 식육판매업소의 위생관리 실태분석 - HACCP 지정업소와 미지정업소 비교를 중심으로 -)

  • Lee, Joo-Yeon;Paik, Jin-Kyoung;Hwang, Hye-Sun;Lee, Joo-Eun;Shin, Weon-Sun;Kim, Hyoun-Wook;Paik, Hyun-Dong;Hong, Wan-Soo
    • Food Science of Animal Resources
    • /
    • v.30 no.2
    • /
    • pp.336-344
    • /
    • 2010
  • Considering the increasing trends of the consumption of livestock products in Korea, proper hygienic management and policies for ensuring their safety to protect public health and strengthen consumer confidence are demanded. It is particularly important to manage the livestock distribution processes to provide safe meat and meat products. This study was conducted to examine factors related to the hygiene management of livestock products and to check out the condition of hygienic management in meat markets. To accomplish this, 156 meat markets divided into HACCP-certified and non certified and evaluated for five factors, which received the following scores: facility and equipment management (1.00/2.0 points, 50.0%), storage and transport management (1.93/2.0 points, 96.5%), work place management (0.76/2.0 points, 38.0%), personal hygiene management (0.75/2.0 points, 37.5%), and inspection management (0.22/2.0 points, 11.0%). The results revealed that the scores of HACCP-certified meat markets were significantly higher than those of the non certified markets (p<0.05, p<0.01, p<0.001). These findings suggest that meat markets that are not HACCP-certified must improve hygienic management conditions and educate their employees to improve the safety of livestock products during distribution.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2015 (설비공학회 분야의 최근 연구 동향 : 2015년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.6
    • /
    • pp.256-268
    • /
    • 2016
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2015. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering were carried out in the areas of flow, heat and mass transfer, cooling and heating, and air-conditioning, the renewable energy system and the flow inside building rooms. Research issues dealing with air-conditioning machines and fire and exhausting smoke were reduced. CFD seems to be spreading to more research areas. (2) Research works on heat transfer area were carried out in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the economic analysis of GHG emission, micro channel heat exchanger, effect of rib angle on thermal performance, the airside performance of fin-and-tube heat exchangers, theoretical analysis of a rotary heat exchanger, heat exchanger in a cryogenic environment, the performance of a cross-flow-type, indirect evaporative cooler made of paper/plastic film. In the area of pool boiling and condensing, the bubble jet loop heat pipe was studied. In the area of industrial heat exchangers, researches were performed on fin-tube heat exchanger, KSTAR PFC and vacuum vessel at baking phase, the performance of small-sized dehumidification rotor, design of gas-injection port of an asymmetric scroll compressor, effect of slot discharge-angle change on exhaust efficiency of range hood system with air curtain. (3) In the field of refrigeration, various studies were carried in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, a cold-climate heat pump system, $CO_2$ cascade systems, ejector cycles and a PCM-based continuous heating system were investigated. In the alternative refrigeration/energy system category, a polymer adsorption heat pump, an alcohol absorption heat pump and a desiccant-based hybrid refrigeration system were investigated. In the system control category, turbo-refrigerator capacity controls and an absorption chiller fault diagnostics were investigated. (4) In building mechanical system research fields, eighteen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the user and location awareness technology applied dimming lighting control system, the lighting performance evaluation for light-shelves, the improvement evaluation of air quality through analysis of ventilation efficiency and the evaluation of airtightness of sliding and LS window systems. The subjects of building energy were worked on the energy saving estimation of existing buildings, the developing model to predict heating energy usage in domestic city area and the performance evaluation of cooling applied with economizer control. The studies were also performed related to the experimental measurement of weight variation and thermal conductivity in polyurethane foam, the development of flame spread prevention system for sandwich panels, the utilization of heat from waste-incineration facility in large-scale horticultural facilities.

Evaluation of water drainage according to hydraulic properties of filling material of sand dam in Mullori, Chuncheon (춘천 물로리 지역 샌드댐 채움재 수리특성에 따른 배수량 평가)

  • Chung, Il-Moon;Lee, Jeongwoo;Kim, Min-Gyu;Kim, Il-Hwan
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.11
    • /
    • pp.923-929
    • /
    • 2022
  • The Chuncheon Mullori area is an underprivileged area of water welfare where local water supply is not supplied, and it is supplying water to the villages with small water supply facilities using lateral flow and groundwater as water sources. This is an area with poor water supply conditions, such as relying on water trucks due to water shortages during the recent severe drought. Therefore, in order to solve the problem of water shortage during drought and to prepare for the increasing water demand, a sand dam was installed along the valley, and this facility has been operating since May 2022. In this study, repeated simulations were performed according to the hydraulic conductivity of the filler material and the storage coefficient value for the inflow condition for about two years from mid-March 2020 to mid-March 2022. For each case, the amount of discharge through the perforated drain pipe was calculated. Overall, as the hydraulic conductivity increased, the amount of discharge and its ratio increased. However, when the hydraulic conductivity of the second floor was relatively low, the amount of discharge increased and then decreased as the hydraulic conductivity of the third floor increased. This is considered to be due to the fact that the water level was kept low due to the rapid drainage compared to the net inflow into the third floor because the water permeability of the third floor and the drainage coefficient of the drain pipe were large. As a result of simulating the flow of the open channel in the upper part of the sand dam as a hypothetical groundwater layer with very high hydraulic conductivity, the decrease in discharge rate was slower than the increase in the hydraulic conductivity of the hypothetical layer, but it was clearly shown that the discharge volume decreased relatively as the hydraulic conductivity of the virtual layer increased.