• Title/Summary/Keyword: storage facilities

Search Result 795, Processing Time 0.028 seconds

A Study on the Odor and Ventilation in Sludge Incineration Facilities (슬러지 소각시설 악취 및 환기에 관한 연구)

  • Seo, Byung-Suk;Jeon, Yong-Han
    • Journal of the Korea Safety Management & Science
    • /
    • v.22 no.2
    • /
    • pp.7-13
    • /
    • 2020
  • Sludge incineration facilities are socially recognized as a hate facility. Therefore, a careful deodorization plan must be established. Therefore, the incineration facility must conduct research on odor ventilation. In this study, a odor diffusion simulation in an incineration facility was conducted and analyzed. In particular, research was carried out on carry-in rooms, pre-treatment rooms, and storage facilities for crops, which are expected to rapidly spread odor. As a result, ammonia 1.62, hydrogen sulfide 0.63, and acetaldehyde 0.73 were found in the transfer room. In addition, pretreatment rooms and stencil storage facilities were found to be lower than regulatory standards.

Preliminary Shielding Analysis of the Concrete Cask for Spent Nuclear Fuel Under Dry Storage Conditions (건식저장조건의 사용후핵연료 콘크리트 저장용기 예비 방사선 차폐 평가)

  • Kim, Tae-Man;Dho, Ho-Seog;Cho, Chun-Hyung;Ko, Jae-Hun
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.15 no.4
    • /
    • pp.391-402
    • /
    • 2017
  • The Korea Radioactive Waste Agency (KORAD) has developed a concrete cask for the dry storage of spent nuclear fuel that has been generated by domestic light-water reactors. During long-term storage of spent nuclear fuel in concrete casks kept in dry conditions, the integrity of the concrete cask and spent nuclear fuel must be maintained. In addition, the radiation dose rate must not exceed the storage facility's design standards. A suitable shielding design for radiation protection must be in place for the dry storage facilities of spent nuclear fuel under normal and accident conditions. Evaluation results show that the appropriate distance to the annual dose rate of 0.25 mSv for ordinary citizens is approximately 230 m. For a $2{\times}10$ arrangement within storage facilities, rollover accidents are assumed to have occurred while transferring one additional storage cask, with the bottom of the cask facing the controlled area boundary. The dose rates of 12.81 and 1.28 mSv were calculated at 100 m and 230 m from the outermost cask in the $2{\times}10$ arrangement. Therefore, a spent nuclear fuel concrete cask and storage facilities maintain radiological safety if the distance to the appropriately assessed controlled area boundary is ensured. In the future, the results of this study will be useful for the design and operation of nuclear power plant on-site storage or intermediate storage facilities based on the spent fuel management strategy.

The Network Design of China's Northeast Cold Chain (중국 동북부지역 콜드체인 네트워크 설계에 관한 연구)

  • Park, Nam-Kyu;Choi, Woo-Young
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.26 no.4
    • /
    • pp.760-768
    • /
    • 2014
  • Yet logistics base in China has a refrigerated storage facilities installed areas, the number of those is very limited and is generally insufficient. According to these especial points, a new construction cold chain logistics network design strategy is required from how to use the existing refrigerated warehouses to new issue. For example, however refrigerated storage facility is supplied, can it satisfy all demand of this area? Then does it have optimized location of this area? If future demand expansion, adding that already other refrigerated storage facilities matter? Or, add another refrigerated facilities, optimum cold chain established a network matter? So on. Above problems can be occurred. In order to solve facing many of these issues of distribution network, northeast area in China has been selected as a subject, and we designed a new cold chain distribution network.

Prospect of large scale Grain Drying, Storage and Milling Facility Complex in Korea (우리나라의 대규모 곡물 종합조제시설의 문제점 및 전망)

  • Kim, Tae Wook;Park, Kyung Kyoo
    • Current Research on Agriculture and Life Sciences
    • /
    • v.14
    • /
    • pp.37-47
    • /
    • 1996
  • The main objectives of this studies are to present the most desirable rice processing complex model system in a given our situations by comparision and analyzing the major factors and, also recommend the future prospect of the rice processing complex in Korea. There are 3 different rice processing complex models in Korea. Those are concrete bin, flat type steel bin and square bin. These systems have a lot of differences and have their own characteristics such as capital requirement, efficiency, storage capacity and quality controls. The major problems of the existing rice processing centers in Korea are high fixed cost and the unbalnced systems. Following is summary to solve this problems: 1. Development of the large scale harvester and high speed continuous dryer. 2. Quality inspective system of bulk grain and large scale temporary storage facilities. 3. Large size readjustment of arable land. 4. Select the convenient location of rice processing center and formulation of well equipment facilities.

  • PDF

Nature-adapted Rainwater Management Facility Cases in Korean Apartment Complexes (국내 공동주택단지 자연 순응형 빗물관리시설 사례 분석)

  • Hyun, Kyoung Hak;Chang, Sun Young;Ahn, Sung Sik
    • Journal of Environmental Impact Assessment
    • /
    • v.15 no.2
    • /
    • pp.111-119
    • /
    • 2006
  • In Korea, an environment-friendly concept of "rain re-cycling" was initially introduced in apartment complex planning and designs in the late 1990s. Although its application cases are extremely few, with the growing importance of rainwater utilization, introduction of rainwater management facilities in urban areas began to drawn keen attention. In urban areas also, plans to introduce rainwater management facilities in apartment complexes as infrastructure improving living environment, such as sewage treatment facilities are very urgently required. In order to introduce rainwater management facilities as infrastructure in an apartment complex, apartment complex cases that had introduced the facilities were reviewed first. In this study, a few applied rainwater management facilities in an apartment complex were surveyed(Infiltration barrel, Rubble porosity storage tank, Underground storage tank). As a result, problems in introducing rainwater management facilities in apartment complexes in Korea were identified.

A Study on Reported Status and Management Plan of Marine Facilities in Korea 2. On the Basis of Region and Type of Facilities (국내 해양시설의 신고 현황과 관리 방안에 관한 연구 2. 지역별 및 시설종류별 현황을 중심으로)

  • Kim, Kwang-Soo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.16 no.3
    • /
    • pp.275-285
    • /
    • 2010
  • Present state of nationwide marine facilities reported to 12 regional maritime affairs and port offices of MLTM in Korea for two years 2008 and 2009 was analyzed based on region and type of facilities, and national management plan was proposed in this study. As of the end of 2009, 8 types of marine facilities were reported to Yeosu regional maritime affairs and port office, while only 3 types of facilities were reported to Pohang, Daesan and Jeju regional offices, respectively. Oil and noxious liquid substances storage facilities belonged in the type of facility which was reported to all of 12 regional offices, and ranged from 11 facilities reported to Pyeongtaek regional office to the respective 38 facilities to Yeosu and Masan regional offices. In pollutants storage facilities, 4 facilities were reported to Masan regional office, 2 facilities to Donghae and Mokpo regional offices, respectively, 1 facility to Yeosu, Gunsan and Pyeongtaek regional offices, respectively, and none of facilities to the other regional offices. Ship construction, repair and scrap facilities belonged in the type of facility which was reported to all of 12 regional offices, and 45% of the facilities were concentrated in Southeastern Sea of Korea centering around Busan and Masan. In cargo handling facilities, 3 facilities were reported to Busan and Masan regional offices, respectively, 1 facility to Daesan regional office, and none of facilities to the other regional offices. In wastes storage facilities, 5 facilities were reported to Ulsan regional office, 4 facilities to Gunsan regional office, 2 facilities to Incheon regional office, 1 facility to Yeosu regional office, and none of facilities to the other regional offices. 65% of nationwide water intake and drainage facilities were concentrated in the areas of Pohang and Mokpo, and 78% of nationwide fishing spots at play were concentrated in the area of Masan. In other marine facilities, 4 facilities were reported to Donghae regional office, 3 facilities to Masan regional office, 2 facilities to Yeosu and Pyeongtaek regional offices, respectively, 1 facility to Incheon and Ulsan regional offices, respectively, and none of facilities to the other regional offices. In integrated marine science base facilities, 3 facilities were reported to Jeju regional office, 1 facility to Yeosu, Ulsan and Gunsan regional offices, respectively, and none of facilities to the other regional offices. The management based on the circumstances of regional offices, the management based on the characteristics of the type of facilities, the amendment of the relevant rules and regulations, facility owner's full knowledge and observance of the relevant rules and regulations with regard to the relevant type of facilities, and positive management actions from national point of view were proposed for national management plans of marine facilities.

System Reliability Analysis of Rack Storage Facilities (물류보관 랙선반시설물의 시스템신뢰성 해석)

  • Ok, Seung-Yong;Kim, Dong-Seok
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.4
    • /
    • pp.116-122
    • /
    • 2014
  • This study proposes a system reliability analysis of rack storage facilities subjected to forklift colliding events. The proposed system reliability analysis consists of two steps: the first step is to identify dominant failure modes that most contribute to the failure of the whole rack facilities, and the second step is to evaluate the system failure probability. In the first step, dominant failure modes are identified by using a simulation-based selective searching technique where the contribution of a failure mode to the system failure is roughly estimated based on the distance from the origin in the space of the random variables. In the second step, the multi-scale system reliability method is used to compute the system reliability where the first-order reliability method (FORM) is initially used to evaluate the component failure probability (failure probability of one member), and then the probabilities of the identified failure modes and their statistical dependence are evaluated, which is called as the lower-scale reliability analysis. Since the system failure probability is comprised of the probabilities of the failure modes, a higher-scale reliability analysis is performed again based on the results of the lower-scale analyses, and the system failure probability is finally evaluated. The illustrative example demonstrates the results of the system reliability analysis of the rack storage facilities subjected to forklift impact loadings. The numerical efficiency and accuracy of the approach are compared with the Monte Carlo simulations. The results show that the proposed two-step approach is able to provide accurate reliability assessment as well as significant saving of computational time. The results of the identified failure modes additionally let us know the most-critical members and their failure sequence under the complicated configuration of the member connections.

Quantification of Flood Reduction Effect of Small Stormwater Detention Facilities by NRCS Curve Number (유출곡선지수를 이용한 소규모 저류시설의 유출저감효과 정량화)

  • Yoo, Chul-Sang;Kim, Kyoung-Jun;Park, Min-Kyu;Yoon, Jeong-Su
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.3
    • /
    • pp.109-118
    • /
    • 2010
  • This study quantified the flood reduction effect of small stormwater detention facilities by the NRCS curve number. The modified rational equation was used to calculate the inflow volume into the detention facilities. The NRCS curve number in the cases w/ and w/o storage facility was calculated with respect to the rainfall characteristics(rainfall frequency, duration) and the size of storage facilities. Finally, diagrams showing the curve number reduction rate versus the size of storage facility were developed. The diagrams can be used to evaluate the flood reduction effect of storage facility reasonably and efficiently when estimating the optimal location and size of storage facility. The results based on the methodology propsed in this study were also compared with those of previous study for their validation.

A Study on the Cost Analysis of risk facilities using e-Consequence Analysis - Focusing Steel pipe Industry (e-CA(e-Consequence Analysis)를 활용한 위험설비의 비용 분석에 관한 연구 : 강관제조업 사례를 중심으로)

  • Kwon, Hyeok Min;Hwang, Yong Woo;Lee, Ik Mo;Chun, Young Woo;Choi, Young Hun
    • Journal of the Korea Safety Management & Science
    • /
    • v.20 no.3
    • /
    • pp.27-36
    • /
    • 2018
  • The steel pipe manufacturing industry deals with facilities and materials. Especially thermal facilities are close to vapor cloud explosion (VCE) and may cause secondary damage to facilities because they deal with corrosive substances such as hydrofluoric acid, sulfuric acid and acid, fire, explosion, leakage etc. It is in danger. In this study, hazard identification method was conducted using HAZOP techniques and quantitative risk analysis was conducted using e-CA, a program that supports accident impact analysis. Equipment in the influence range of ERPG - 3 was determined to be a facility requiring replacement. It was decided that neutralization is necessary using slaked lime. Based on the cost of loss, We presented the proper replacement which is the timing of the dangerous facility. As a result, It was ideal to replace the facilities with 20 years of heat treatment facilities, one year of hydrofluoric acid storage tank, 20 years of sulfuric acid storage tank, and 5 years of hydrochloric acid storage tank.

A Study on the Tool-Trace of Wooden Storage Facilities in Sabi Baekje through the Reproduction Experiments: Focusing on the Adze, Chisel, and Saw

  • Heesoo SONG;Soochul KIM
    • Journal of the Korean Wood Science and Technology
    • /
    • v.52 no.3
    • /
    • pp.276-288
    • /
    • 2024
  • This study was conducted to reproduce the woodworking process of Baekje wooden storage facilities. Green timber of Quercus spp. was processed using ancient woodworking tools, and the tool-trace formed in this process were compared with the tool-trace of actual excavated artifacts. In the tool-trace analysis, the length and shape of the tool-trace were objectively recorded using a 3D Scan, and that were difficult to confirm with photograph were confirmed through stereoscopic microscope. As a result, there were two types of adze's tool-trace. One of them is minute straight Blade-top trace line when trimming the wood surface and the other is Plucked trace that appear when strongly chop at the wood. When a chisel bat was not used, a long and wide continuous shape blade trace was produced. And when the chisel head was struck with the chisel bat, a straight blade-top trace was regularly observed. Saw-trace was identified in several layers with fine straight stripes. Through this, it was found that the tool-trace of the woodworking tools, which is estimated to have been used in each process, and the tool-trace remaining in the Baekje wooden storage facility coincide.