• Title/Summary/Keyword: storage direction

Search Result 319, Processing Time 0.033 seconds

Design of 2-axis compensation servo system for angle multiplexing Holographic Data Storage (각 다중화 방식의 홀로그래픽 정보저장기기의 양방향틸트 보상시스템 설계)

  • Lim, Sung-Yong;Kim, Nak-Yeong;Han, Cho-Lok;Park, Kyoung-Su;Park, No-Cheol;Yang, Hyun-Seok;Park, Young-Pil
    • Transactions of the Society of Information Storage Systems
    • /
    • v.7 no.1
    • /
    • pp.19-24
    • /
    • 2011
  • Holographic Data Storage System, one of the next generation data storage devices, is a 2-dimensional page oriented memory system using volume holograms in writing and retrieving process. Recently photopolymer with disc type substrate was selected as a media for the Holographic Data Storage System. The disc tilt occurs when the media rotates and the external disturbance applies. The disc tilt causes the change of the angle between the reference beam and the media, the data cannot be retrieved with the right angle or other data page is retrieved. The tilt is generated in a 2-axis direction (tangential, radial). The tangential tilt direction is the same with the multiplexing plane, while the radial tilt direction is a perpendicular to the multiplexing plane. In this research we propose 2-axis tilt angle servo system. The tilt errors are measured by using external photo detector and the additional red laser. Then the tangential direction tilt is compensated by using the galvano mirror. Also the radial direction tilt is compensated by the rotating prism between the relay lens in the reference field. Finally we confirm the compensation results through the Signal to Noise Ratio(SNR) and Bit Error Rate(BER).

A Study on the Efficiency of Energy Storage System Applied to the Power Traction System of DC Electric Railway (직류전기철도에서 운행시격에 따른 에너지저장장치의 효율에 관한 연구)

  • Kim, Sung-Dae;Choi, Kyu-Hyoung
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.754-760
    • /
    • 2011
  • In the DC traction system, a large load current of electric railcar leads to a voltage drop when a vehicle starts, and the regenerative power generated by brake system increases the catenary voltage. To minimize the voltage fluctuation during the train operation and make use of the regenerative power, several types of energy storage systems are being studied. The energy storage system that is being recently introduced consists of the supercapacitors for energy storage and the bi-direction DC/DC converter for charge/discharge control. The efficiency of the energy storage system depends on the train operation pattern. In this paper, the operation efficiency of the energy storage system was quantitatively analyzed via simulation study taking consideration of the train operation patterns. The simulation was conducted changing the headway of trains with the energy storage system that uses the bi-direction DC/DC converter and supercapacitor. The simulation results showed that the operation efficiency of the energy storage system increases as the headway increase.

  • PDF

Strength upgrading of steel storage rack frames in the down-aisle direction

  • El Kadi, Bassel;Cosgun, Cumhur;Mangir, Atakan;Kiymaz, Guven
    • Steel and Composite Structures
    • /
    • v.23 no.2
    • /
    • pp.143-152
    • /
    • 2017
  • This paper focuses on the seismic performance of pallet-type steel storage rack structures in their down aisle direction. As evidenced by experimental research, the seismic response of storage racks in the down-aisle direction is strongly affected by the nonlinear moment-rotation response of the beam-to-column connections. In their down-aisle direction, rack structures are designed to resist lateral seismic loads with typical moment frames utilizing proprietary beam-to-column moment-resisting connections. These connections are mostly boltless hooked type connections and they exhibit significantly large rotations resulting in large lateral frame displacements when subjected to strong ground motions. In this paper, typical hooked boltless beam-to-column connections are studied experimentally to obtain their non-linear reversed cyclic moment-rotation response. Additionally, a compound type connection involving the standard hooks and additional bolts were also tested under similar conditions. The simple introduction of the additional bolts within the hooked connection is considered to be a practical way of structural upgrade in the connection. The experimentally evaluated characteristics of the connections are compared in terms of some important performance indicators such as maximum moment and rotation capacity, change in stiffness and accumulated energy levels within the cyclic loading protocol. Finally, the obtained characteristics were used to carry out seismic performance assessment of rack frames incorporating the tested beam-to-column connections. The assessment involves a displacement based approach that utilizes a simple analytical model that captures the seismic behavior of racks in their down-aisle direction. The results of the study indicate that the proposed method of upgrading appears to be a very practical and effective way of increasing the seismic performance of hooked connections and hence the rack frames in their down-aisle direction.

Simplified Analysis of Rectangular Liquid Storage Tanks Considering Fluid-Structure Interaction (유체-구조물 상호작용을 고려한 직사각형 액체저장탱크의 단순해석법)

  • Lee, Jin Ho;Cho, Jeong-Rae
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.26 no.5
    • /
    • pp.203-209
    • /
    • 2022
  • A simplified method for earthquake response analysis of a rectangular liquid storage tank is proposed with fluid-structure interaction considered. In order to simplify the complex three-dimensional structural behavior of a rectangular liquid storage tank, it is assumed that structural deformation does not occur in the plane parallel to the direction in which the earthquake ground motion is applied but in the plane perpendicular to the direction. The structural deformation is approximated by combining the natural modes of the simple beam and the cantilever beam. The hydrodynamic pressure, the structure's mass and stiffness, and the hydrodynamic pressure's added mass are derived by applying the Rayleigh-Ritz method. The natural frequency, structural deformation, pressure, effective mode mass, and effective mode height of the rectangular liquid storage tank are obtained. The structural displacement, hydrodynamic pressure, base shear, and overturning moment are calculated. The seismic response analysis of an example rectangular liquid storage tank is performed using the proposed simplified approach, and its accuracy is verified by comparing the results with the reference solution by the finite element method. Existing seismic design codes based on the hydrodynamic pressure in rigid liquid storage tanks are observed to produce results with significant errors that cannot be ignored.

Study for Charge-Discharge Auto Level-Tuning Algorithm of Energy storage system (에너지저장시스템의 충, 방전 Auto Level-Tuning 알고리즘에 관한 연구)

  • Baek, Seoung-Gil;Lim, Ji-Young;Cha, Joon-Il;Kim, Kil-Dong;Kwon, Kyoung-Min
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.514-520
    • /
    • 2010
  • This paper is about control algorithms that bi-direction DC-DC Converter using Super Capacitor and regenerative power from DC feeding system in train. In order to take advantage of regenerative energy efficient, charge and discharge level value of energy storage system serve as an important factor. Respect to output fluctuations of the substation and catenary voltage changing, we offers Charge-Discharge Auto Level Tuning Algorithms to improve system following of Energy Storage System.

  • PDF

A New Evaluation Method for the Effectiveness of Standardized Storage Facilities (보관시설의 표준화 효과 평가방안 연구)

  • Choi, Chang-Ho;Lee, Ok-Joo;Park, Mi-Ran;Kim, Gwang-Ho
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.1924-1930
    • /
    • 2009
  • According to Korea Standard Association (KSA-0013) storage facilities are so broadly defined that one cannot easily understand the area and contents of storage facilities. Generally speaking warehouse represents storage facilities which links two nodes in various logistics activities, and storage facilities should contain other facilities like mechanization equipment, automation equipment, information equipment, etc. This study is to show the direction of the evaluation method on the effectiveness of standardized storage facilities. The storage facilities treated in this research are not only storage facilities like warehouse but also storage supporting facilities like mechanization equipment, automation equipment, information equipment, etc. The method for evaluating the effectiveness of standardized storage facilities is to developing some measure of effectiveness (MOE) which represents the entire standardized effectiveness of storage related facilities. This study has originality in that the method for evaluation of standardized storage facilities has not been developed up to now.

  • PDF

Numerical Study on the Effects of Gravity Direction and Hydrogen Filling Rate on BOG in the Liquefied Hydrogen Storage Tank (액체수소 저장 탱크의 중력 방향 및 수소 충전율이 BOG에 미치는 영향에 관한 수치적 연구)

  • YOUNG MIN SEO;HYUN WOO NOH;DONG WOO HA;TAE HYUNG KOO;ROCK KIL KO
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.34 no.4
    • /
    • pp.342-349
    • /
    • 2023
  • In this study, a numerical simulations were conducted to analyze the phase change behavior of a liquid hydrogen storage container. The effects of gravity direction and hydrogen filling rate on boil-off gas (BOG) in the storage container were investigated. The study employed the volume of fluid, which is the phase change analysis model provided by ANSYS Fluent (ANSYS, Canonsburg, PA, USA), to investigate the sloshing phenomenon inside the liquefied hydrogen fuel tank. Considering the transient analysis time, two-dimensional simulation were carried out to examine the characteristics of the flow and thermal fields. The results indicated that the thermal flow characteristics and BOG phenomena inside the two-dimensional liquefied hydrogen storage container were significantly influenced by changes in gravity direction and hydrogen filling rate.

Flow Analysis indoor Coal Storage Shed due to Wind Velocity and Wind Direction of Ambient Air (외기의 풍속 및 풍향에 따른 옥내저탄장 내부 유동 해석)

  • Kim, Tae-Kwon;Cho, Mok-Lyang;Bae, Young-Wan;Kim, Ji-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.538-545
    • /
    • 2020
  • The outdoor coal storage sheds of thermal power plants are being converted to indoor coal storage sheds worldwide because of the environmental pollution problems in the surrounding areas. On the other hand, indoor coal storage sheds are causing problems, such as indoor coal scattering and harmful gas generation. In this study, the ventilation method of indoor coal storage sheds was analyzed in terms of the internal flow characteristics and ventilation according to the outside wind velocity and direction. CFD analysis was performed based on the actual flow measurement information inside the indoor coal storage sheds. A comparison of the wind speed of 6 m/s and 2 m/s when the outside wind direction was easterly showed that the stream velocity to the monitor louver was faster and the recirculation area was clearer at 6 m/s than at 2 m/s. In addition, the trend of a westerly wind was similar to that of the easterly wind. The ventilation rate according to the wind speed was 13.1 times and 4.4 times for a wind speed of 6 m/s and 2 m/s, respectively. If the wind speed is 2 m/s, the situation does not meet the required number of ventilations per hour in a general plant, and needs to be improved.

Quasi-static Characteristics in Radial Direction of 100 kWh Class Superconductor Bearing (100 kWh급 초전도 베어링의 지름방향 준정적 특성)

  • Jung, S.Y.;Park, B.J.;Han, Y.H.;Park, B.C.;Lee, J.P.;Han, S.C.
    • Progress in Superconductivity
    • /
    • v.12 no.1
    • /
    • pp.27-31
    • /
    • 2010
  • A superconductor flywheel energy storage system (SFES) is an electro-mechanical battery which transforms electrical energy into mechanical energy for storage, and vice versa. Many aspects of the quasi-static behavior of flywheel rotors still need to be studied closely, and the rotors require a stable and highly efficient supporting system such as high temperature superconductor (HTS) bearings, which offer dynamic stability without the use of active control. Quasi-static properties of HTS bearings in the radial direction provide data to solve problems which may occur in a running system. Since stiffness in countering rotor vibration is the main parameter for designing an HTS bearing system, we investigated the quasi-static properties of the magnetic force between permanent magnets(PMs) and HTS bulks in the radial direction. We measured radial stiffness, and discovered that bearing stiffness varied greatly depending on the number of active HTS bulks. This is valuable data for predicting the change in stiffness during partial HTS bearing failure. The quasi-static test results are used for optimal design and performance prediction for the 100 kWh class superconductor bearing.

Shaking table test of liquid storage tank with finite element analysis considering uplift effect

  • Zhou, Junwen;Zhao, Ming
    • Structural Engineering and Mechanics
    • /
    • v.77 no.3
    • /
    • pp.369-381
    • /
    • 2021
  • The seismic responses of elevated tanks considering liquid-structure interaction are presented under horizontal earthquake. The scaled model tank is fabricated to study the dynamic responses of anchored tank and newly designed uplift tank with replaced dampers. The natural frequencies for structural mode are obtained by modal analysis. The dynamic responses of tanks are completed by finite element method, which are compared with the results from experiment. The displacement parallel and perpendicular to the excitation direction are both gained as well as structural acceleration. The strain of tank walls and the axial strain of columns are also obtained afterwards. The seismic responses of liquid storage tank can be calculated by the finite element model effectively and the results match well with the one measured by experiment. The aim is to provide a new type of tank system with vertical constraint relaxed which leads to lower stress level. With the liquid volume increasing, the structural fundamental frequency has a great reduction and the one of uplift tank are even smaller. Compared with anchored tank, the displacement of uplift tank is magnified, the strain for tank walls and columns parallel to excitation direction reduces obviously, while the one perpendicular to earthquake direction increases a lot, but the values are still small. The stress level of new tank seems to be more even due to uplift effect. The new type of tank can realize recoverable function by replacing dampers after earthquake.