• 제목/요약/키워드: stimulation

검색결과 5,702건 처리시간 0.031초

미주신경 자극을 위한 새로운 방법 : 비침습적 TENS 적용에 대한 미주신경 자극의 치료적 효과 (New Methods of Vagus Nerve Stimulation : Therapeutic Effects of Non-Invasive Vagus Nerve Stimulation by TENS Application)

  • 권해연;문현주
    • 대한통합의학회지
    • /
    • 제4권4호
    • /
    • pp.77-82
    • /
    • 2016
  • Purpose: The purpose of this study was to investigate the therapeutic effect of non-invasive vagus nerve stimulation by transcutaneous electrical nerve stimulation application on the autonomic nervous system of human body. Methods: Participants were seventeen healthy adults. Standard deviation of all normal N-N intervals(SDNN), root mean square of successive differences(RMSSD), low frequency(LF), high frequency(HF) were compared in pre and post Mean values after intervention. Data were analyzed in Wilcoxon's signed-ranks test. Results: The results of this study is that sistolic blood pressure and pulse rate decreased mean value after non-invasive vagus nerve stimulation by transcutaneous electrical nerve stimulation. High frequency, low frequency, SDNN, RMSSD increased mean value in heart rate variability after intervention. But that is not significant except for SDNN. Conclusion: Non-invasive vagus stimulation by transcutaneous electrical nerve stimulation effect on parasympathetic nerve stimulation, and then it might be effective method for autonomic nerve balance control.

자계 거울 효과를 이용한 신경 자극 코일 (Magnetic Nerve Stimulation Coils with Magnetic Mirror Effect)

  • 한병희;김기왕;김재곤;박태석;이수열;조민형;양종수;김정회
    • 대한의용생체공학회:의공학회지
    • /
    • 제23권4호
    • /
    • pp.287-293
    • /
    • 2002
  • 시변 자계를 이용하여 비접촉적인 방법으로 신경을 자극하기 위해서는 신경자극코일에 대용량 전류 펄스를 순시적으로 인가해야만 한다. 신경자극코일에 인가하는 전류 펄스의 주파수를 증가할수록 신경자극코일에 전력을 공급하는 전력공급기의 용량이 커지게 되고 신경자극코일에 발생하는 열량도 커지는 문제가 발생한다. 본 논문에서는 이러한 문제를 완화하기 위해 새로운 형태의 신경자극코일을 제안하였다. 신경자극코일에 강자성체 구조물을 부착하여 자계 거울 효과를 내게 하면 신경자극코일의 효율이 증가하게 된다. 다양한 형태의 신경자극코일에 대해 자계 거울 효과를 유한요소법으로 분석하였고 몇 종류의 신경자극코일에 대해 실험한 결과를 제시하였다.

Study of moxibustion stimulation in the ovariectomized rat model

  • Kanai, Shigeyuki;Taniguchi, Norimasa;Kanda, Kayo;Matsuhata, Izuru
    • Advances in Traditional Medicine
    • /
    • 제5권3호
    • /
    • pp.195-200
    • /
    • 2005
  • In order to examine the effectiveness of moxibustion stimulation for climacteric disturbance, we administered moxibustion stimulation to ovariectomized (OVX) rats, and compared the tail surface temperature, laboratory parameters, and the level of locomotor activity with those of untreated rats. Twenty-four female Wistar rats (8 weeks old, 160 - 180 g) were divided into three groups. The rats in the OVX-M group underwent moxibustion stimulation after ovariectomy. The rats in the OVX-C group underwent ovariectomy but did not receive moxibustion stimulation. The rats in the Normal group received neither ovariectomy nor moxibustion stimulation. The level of locomotor activity was determined by a metabolism measuring system. The tail surface temperature was significantly lower in the OVX rats before moxibustion stimulation than in the Normal group. In the OVX rats before moxibustion stimulation, there was no clear difference in the level of locomotor activity between the active and resting phases, and the pattern of locomotor activity was irregular. After moxibustion stimulation, the tail surface temperature of the OVX-M group did not significantly differ from that of the Normal group, and the pattern of locomotor activity of the OVX-M group became diphasic with clear active and resting phases, similar to that observed in the Normal group. These results demonstrate that moxibustion stimulation is effective for the treatment of climacteric disturbance.

Starting Current Application for Magnetic Stimulation

  • Choi, Sun-Seob;Bo, Gak-Hwang;Kim, Whi-Young
    • Journal of Magnetics
    • /
    • 제16권1호
    • /
    • pp.51-57
    • /
    • 2011
  • A power supply for magnetic-stimulation devices was designed via a control algorithm that involved a start current application based on a resonant converter. In this study, a new power supply for magnetic-stimulation devices was designed by controlling the pulse repetition frequency and pulse width. The power density could be controlled using the start-current-compensation and ZCS (zero-current switching) resonant converter. The results revealed a high-repetition-frequency, high-power magnetic-stimulation device. It was found that the stimulation coil current pulse width and that pulse repetition frequency could be controlled within the range of 200-450 ${\mu}S$ and 200-900 pps, respectively. The magnetic-stimulation device in this study consisted of a stimulation coil device and a power supply system. The maximum power of the stimulation coil from one discharge was 130 W, which was increased to 260 W using an additional reciprocating discharge. The output voltage was kept stable in a sinusoidal waveform regardless of the load fluctuations by forming voltage and current control using a deadbeat controller without increasing the current rating at the starting time. This paper describes this magnetic-stimulation device to which the start current was applied.

Sacral Nerve Stimulation Through the Sacral Hiatus

  • Park, Chan-Hong;Kim, Bong-Il
    • The Korean Journal of Pain
    • /
    • 제25권3호
    • /
    • pp.195-197
    • /
    • 2012
  • Sacral nerve stimulation through the retrograde approach has been used for peroneal or irritable bowel syndrome through the retrograde approach. However, several reasons, lead could not be advanced down ward. In this case, anterograde sacral nerve stimulation through the sacral hiatus could be used. The aim of this report is to present of technique of sacral nerve root stimulation through the sacral hiatus approach.

Effects of the Vestibular Caloric Stimulation with Ice Water on the Autonomic Nervous System

  • Kim, Chungyoo;Kang, Jongho
    • 대한통합의학회지
    • /
    • 제4권3호
    • /
    • pp.27-30
    • /
    • 2016
  • PURPOSE : The effect of the vestibular caloric stimulation with ice water on the autonomic nervous system was investigated using pulse oximetry. METHOD : Thirty-four healthy men and women were subject to a 2-minute vestibular caloric stimulation with ice water, and autonomic nervous activities (low frequency, high frequency, and total power) were measured before and after the vestibular caloric stimulation. Data were analyzed separately for men and women. RESULT : Low frequency, high frequency, and total power in the men and low frequency in the women were statistically significantly higher after vestibular caloric stimulation. High frequency and total power in the women were higher but not significantly different after vestibular caloric stimulation. CONCLUSION : Vestibular caloric stimulation with ice water increases autonomic nervous activities, with the variation being within the normal range. The test can be considered safe for use.

평류전정자극에 의한 H 반사의 변화 (The Change of H Reflex by Galvanic Vestibular Stimulation)

  • 황태연;김태열;박장성
    • 대한임상전기생리학회지
    • /
    • 제2권3호
    • /
    • pp.65-73
    • /
    • 2004
  • In experimental method, this study was that galvanic vestibular stimulation in vestibular system influenced the excitability of spinal neuron through. H-reflex was measured by galvanic vestibular stimulation of binaural(right-negative pole and left-positive pole) at left head turning and prone position in sixteen normal subjects in their twenties age were selected. The summary of the comparison results were obtained below. 1. In the change of H reflex according to galvanic vestibular stimulation(GVS), Hmax amplitude(p<.05) increased significantly after stimulation. 2. In the change of H reflex according to galvanic vestibular stimulation(GVS), Hmax/Mmax ratio(p<.05) increased significantly after stimulation. In the conclusion, galvanic vestibular stimulation influenced the excitability of vestibulospinal tract and spinal neuron.

  • PDF

전기자극이 상처치유에 미치는 효과 (Effects of Electrical Stimulation on Wound Healing : Review of the Literature)

  • 김식현;김수민;김용수
    • 대한물리치료과학회지
    • /
    • 제1권2호
    • /
    • pp.333-343
    • /
    • 1994
  • This study was performed to assess the efficacy of electrical stimulation for healing of wound in injured tissue, and to provide a baseline for electrical stimulation in the treatment. Although the specific mechanism by electrical stimulation which may promote injured tissue to heal is not known, generally many hypothesis exist such as bactericidal effect, enhanced circulation, stimulation of cellular biosynthesis and replication, and attraction of connective tissues and inflammatory cells The results of this study are as follows : 1. The healing of skin wound was facilitated by electrical stimulation 2. The capacity of collagen synthesis was significantly accelerated by electrical stimulation 3. The application of electrical stimulation to injured tissue may be helpful in augmenting the rate of wound contracture

  • PDF

정신질환에서 뇌자극술의 적용 (The Application of Brain Stimulation in Psychiatric Disorders : An Overview)

  • 노대영;강리영;김도훈
    • 생물정신의학
    • /
    • 제24권4호
    • /
    • pp.167-174
    • /
    • 2017
  • Based on advances in biotechnology and neuroscience, neuromodulation is poised to gain clinical importance as a treatment modality for psychiatric disorders. In addition to old-established electroconvulsive therapy (ECT), clinicians are expected to understand newer forms of neurostimulation, such as deep brain stimulation (DBS), vagus nerve stimulation (VNS), repetitive transcranial magnetic stimulation (rTMS), transcranial direct current stimulation (tDCS) and transcranial alternating current stimulation (tACS). Given the growing interest in non-invasive neuromodulation technologies, clinicians may seek sufficient information about neuromodulation to inform their clinical practice. A growing literature suggests that applications of non-invasive neuromodulation have evidence particularly for indications where treatments are currently insufficient, such as drug-resistant depression. However, positive neuromodulation studies require replication, and the precise interactions among stimulation, antidepressant medication, and psychotherapy are unknown. Further studies of long-term safety and the impact on the developing brain are needed. Non-invasive neuromodulatory devices could enable more individualized treatment. However, do-it-yourself (DIY) stimulation kits require a better understanding of the effects of more frequent patterns of stimulation and raise concerns about clinical supervision, regulation, and reimbursement. Wide spread enthusiasm for therapeutic potential of neuromodulation in clinical practice settings should be mitigated by the fact that there are still research gaps and challenges associated with non-invasive neuromodulatory devices.

Neuronal Responses in the Globus Pallidus during Subthalamic Nucleus Electrical Stimulation in Normal and Parkinson's Disease Model Rats

  • Ryu, Sang Baek;Bae, Eun Kyung;Kim, Jinhyung;Hwang, Yong Sup;Im, Changkyun;Chang, Jin Woo;Shin, Hyung-Cheul;Kim, Kyung Hwan
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제17권4호
    • /
    • pp.299-306
    • /
    • 2013
  • Deep brain stimulation (DBS) of the subthalamic nucleus (STN) has been widely used as a treatment for the movement disturbances caused by Parkinson's disease (PD). Despite successful application of DBS, its mechanism of therapeutic effect is not clearly understood. Because PD results from the degeneration of dopamine neurons that affect the basal ganglia (BG) network, investigation of neuronal responses of BG neurons during STN DBS can provide informative insights for the understanding of the mechanism of therapeutic effect. However, it is difficult to observe neuronal activity during DBS because of large stimulation artifacts. Here, we report the observation of neuronal activities of the globus pallidus (GP) in normal and PD model rats during electrical stimulation of the STN. A custom artifact removal technique was devised to enable monitoring of neural activity during stimulation. We investigated how GP neurons responded to STN stimulation at various stimulation frequencies (10, 50, 90 and 130 Hz). It was observed that activities of GP neurons were modulated by stimulation frequency of the STN and significantly inhibited by high frequency stimulation above 50 Hz. These findings suggest that GP neuronal activity is effectively modulated by STN stimulation and strongly dependent on the frequency of stimulation.