• 제목/요약/키워드: still-water system

검색결과 318건 처리시간 0.025초

뱀장어 양식장에서 발생하는 온실가스 배출량 산정 (Estimation of Green-House-Gas emissions from domestic eel farm)

  • 김종현;이경훈;이동길;박성욱;양용수
    • 수산해양기술연구
    • /
    • 제50권1호
    • /
    • pp.58-66
    • /
    • 2014
  • The purpose of the study is to estimate the Green-House-Gas (GHG) emissions from domestic eel farm in the water recirculation system or still-water system by the assessment of energy consumptions and GHG emissions for establishing to reduce standards of GHG from a sustainable perspective. GHG emission components as seeds, feed, fuel, electricity, fixed capital, fish respiration, and others were analysed at the different culture type between water recirculation system and still-water system by 3 stage farm size of small, medium, large scale. The result showed that the mean GHG emission of the eel farm was $18.7kg{\cdot}CO_2$ in the stage of production per fish 1kg at different culture type and farm size. Therefore it could be useful for policy, planning, and regulation of aquaculture development with establishing GHG reduction standards.

A Study on the Propulsion Performance of KCS in Still Water and Regular Wave

  • Lee, Sang-Min;Jeong, Uh-Cheul;Kim, Dae-Hae
    • 한국항해항만학회지
    • /
    • 제37권1호
    • /
    • pp.63-69
    • /
    • 2013
  • Since most merchant vessels are mainly influenced by the added resistance in an actual sea, they could be navigated more efficiently if this added resistance could be precisely predicted and then effectively reduced. In this paper, we have computed the effective horsepower based on the resistance performance in still water and then calculated the added resistance in regular wave in order to estimate a ship's propulsion performance on a voyage. Firstly, we have performed experiments using a model of KCS in a circulating water channel to estimate the flow characteristics around a container ship and the ship's resistance in still water. Then we have calculated the motion response function in regular wave as well as the values for the increase in resistance, and evaluated the ship's motion performance in waves according to the calculated response function. It was found that the resistance in waves increased because the ship's motion response value became larger as the ship's speed increased in the case of head sea. The effect of the added resistance could be reduced by maneuvering the ship to the encounter angle of $120^{\circ}$ in areas of long wavelengths and to head sea in areas of short wavelengths.

수돗물 신뢰도 향상을 위한 품질 인증 제도 도입 (Introduction of Water Quality Certification System for Confidence Improvement of Tap Water)

  • 김진근
    • 상하수도학회지
    • /
    • 제29권2호
    • /
    • pp.155-163
    • /
    • 2015
  • Many advanced treatment processes have been introduced to WTPs, however, the consumer confidence on tap water is still low and the percentage of drinking water directly from the tap is less than 2 %. One of the methods to improve the credibility of tap water is to introduce a drinking water certification system. By introducing the system, water treatment processes can be optimized, which in turn, can significantly improve drinking water quality. In this paper, 6 water quality parameters(i.e., turbidity, CT, residual chlorine, geosmin, 2-MIB, Mn) which have significant influences on tap water quality and consumer confidence were identified, and their recommended guidelines were proposed. 3-Star or 5-Star certification can be awarded to the WTPs which have met the certification criteria. The drinking water certification system can be carried out as a voluntary program among drinking water suppliers.

상수도 자동 검침 시스템 구축에 관한 연구 : 부산 기장군과 김해시 사례를 중심으로 (Automatic Meter Reading System for Water-Supply)

  • 서창갑;박영재
    • 디지털융복합연구
    • /
    • 제7권3호
    • /
    • pp.103-111
    • /
    • 2009
  • In this paper, we introduce automatic meter reading system for tap water. The system is composed of automatic meter, router using RF and CDMA network, and data server. This system will easily extend to fire detect, gas, and electric charge meter system. In addition, this system will be used to monitoring a water leak and human which live in solitude. Proposed system is installed at Gimhae-City and Gijang-gun. As a result of the automatic meter reading system for tap water, The leak of water and complain of user is decreased. But The building cost is still an obstacle to expand into entire city.

  • PDF

On the Robustness of Watermarking in the Frequency Domain for Still Images

  • Miyazaki, Akio;Ejima, Masataka
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 ITC-CSCC -2
    • /
    • pp.861-864
    • /
    • 2000
  • This paper aims to establish fundamentals of measuring and evaluating the performance of water-marking systems. We first present the general model of a watermarking method for still images. Based on this model, we propose a statistical method of measuring the performance and robustness of the watermarking system. Then, the DCT-based watermarking system is analyzed and its performance is evaluated by using the proposed method.

  • PDF

GIS를 이용한 상수관망 소블록 최적설계기법 개발 (Optimal design methodology of district metered area utilizing Geographic Information System)

  • 김경필;박용균;구자용
    • 상하수도학회지
    • /
    • 제29권2호
    • /
    • pp.223-231
    • /
    • 2015
  • District Metered Area (DMA) construction is one of the most cost effective alternatives for management of water loss (i.e., water leakage) and energy consumption (i.e., water pressure) in water distribution systems. Therefore, it's being implemented to numerous new and existing water distribution systems worldwide. However, due to the complexity of water distribution systems, especially large-scale and highly looped systems, it is still very difficult to define the optimal boundary of DMAs considering all the aspects of water distribution system management requirements. In this study, a DMA design methodology (or a DMA design model) was developed with Geographic Information Systems (GIS) and hydraulic distribution system model to determine the optimal DMA boundary.

수도권상수도의 수질-문제점과 대책 (Tap Water Quality in Seoul Metropolitan Area)

  • 김동치
    • 환경위생공학
    • /
    • 제5권2호
    • /
    • pp.15-21
    • /
    • 1990
  • Current analyses of tap water in Seoul metropolitan area prove the water is still safe, despite the Pollution of raw water source. However, it also significantly suggests that a feasibility study of apply, additional advanced technology to existing water treatment processes is needed in order to cope with future pollution. Also, the monitoring of water quality within private, multi-household buildings is important as the monitoring of public water distribution system.

  • PDF

The Variation of Yield-Related Traits of the QTL Pyramiding Lines for Climate-resilience and Nutrition Uptake in Rice

  • Joong Hyoun Chin
    • 한국작물학회:학술대회논문집
    • /
    • 한국작물학회 2022년도 추계학술대회
    • /
    • pp.14-14
    • /
    • 2022
  • Greenhouse gas emissions are one of the critical factors that drive change in rice cropping systems. Within this changing system, less water irrigation and chemical fertilizer are seriously considered, as well combining precision farming technologies with irrigation control. Water and phosphorus (P) fertilizer are two of the most critical inputs in rice cultivation. Due to the lack of water availability in the system, P fertilizer is not available, especially in acidic soil conditions. Moreover, the various types of abiotic stresses, such as drought, high temperature, salinity, submergence, and limited fertilizer result in significant yield loss in the system. Even in the late stage of growth, the waves caused by diseases and insects make the field more unfruitful. Therefore, agronomists and breeders need to identify the secondary phenotypes to estimate the yield loss of when stress appears. The prediction will be clearer if we have a set of markers tagging the causal variation and the associated precise phenotype indices. Although there have been various studies for abiotic stress tolerance, we still lack functional molecular markers and phenotype indices. This is due to the underlying challenges caused by environmental factors in highly unpredictable regional and yearly environmental conditions in the field system. Pupl (phosphorus uptake 1) is still known as the first QTL associated with phosphorus uptake and have been validated in different field crops. Interestingly, some pyramiding lines of Pupl and other QTLs for other stress tolerances showed preferable phenotypes in the yield. Precise physiological studies with the help of genomics are on-going and some results will be discussed.

  • PDF

매립된 유체함입 강파이프의 파동전파 특성규명 (Characteristics of Acoustic Waves That Propagate in Buried Iron Water Pipes)

  • 박경조
    • 동력기계공학회지
    • /
    • 제10권1호
    • /
    • pp.65-70
    • /
    • 2006
  • A study of the possible axisymmetric modes that propagate at low frequencies in buried, water-filled iron pipes is presented. It is well known that for a vacuum-pipe-vacuum system the sole non-torsional axisymmetric mode that exists at low frequencies is the fundamental L(0,1) mode. When a pipe is filled with water and still surrounded by a vacuum it is also known that another mode then appears which at low frequencies is characterized by predominantly axial water-borne displacements. In addition to these modes, this paper explores two other, less well known axisymmetric modes whose existence depends on the acoustic properties of the outer medium that surrounds a pipe. In this paper the predicted characteristics of these modes are presented.

  • PDF