• Title/Summary/Keyword: stiffness factor

Search Result 643, Processing Time 0.025 seconds

Stiffness Reduction Factor for Flat-Plate Structures under Combined Load (조합하중을 받는 무량판 구조의 강성 감소 계수에 관한 고찰)

  • 송진규;최정욱;윤정배
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.302-310
    • /
    • 2003
  • Cracking of slabs will be caused by applied load and volume changes during the life of a structure and thus it reduces flexural stiffness of slabs. The effect of slab cracking must be considered for appropriate modeling of the flexural stiffness for frame members used in structural analysis. Analytical and experimental study was undertaken to estimate the stiffness reduction of slabs. In the analytical approach, the trend of slab stiffness reduction related to gravity and lateral loads is found and the stiffness reduction factor ranged from a half to a quarter in ACI building code is reasonable when defining range. Analyzing results of the test by Hwang and Moehle for 0.5% drift show that the differences of rotational stiffness on the connection types is found and good results of lateral stiffness using the value of one-third is obtained.

  • PDF

A Study on the Influence Factor in Measuring the Dynamic Stiffness and Loss Factor of Damping Materials (완충재의 동탄성 및 손실계수 측정 시 영향인자에 관한 연구)

  • Lee, S.H.;Jeong, G.C.;Chung, J.Y.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.279-282
    • /
    • 2005
  • The aim of this study is to suggest the method of measuring the dynamic stiffness and loss factor of materials used under floating floors in the dwelling by korea standard (KS F 2868). According to the results, the amplitude change of an impact source have no effect on the variation of the dynamic stiffness and loss factor. Comparing with the heating before, heating makes lower the dynamic stiffness except the EPS. In EVA material, the loss factor is increased by heating.

  • PDF

Determination of the Nonlinear Parameters of Stiffness and Force Factor of the Loudspeaker (스피커 지지부 강성과 Force Factor의 비선형계수 추출)

  • Doo, Se-Jin;Sung, Koeng-Mo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.5
    • /
    • pp.29-35
    • /
    • 1995
  • Nonlinear distortion arising from the nonlinear movement of the loudspeaker diaphragm degradates the tone quality. The distortion is, in low frequency range, mainly caused by nonlinear characteristics of the suspension stiffness and the force factor. In this paper, the nonlinear suspension stiffness and the nonlinear force factor are modeled to the quadratic functions and a method is proposed to determine their coefficients. An additional mass to the diaphragm moved the quiescent point of the diaphragm and uncoupled the stiffness and the force factor. This made it possible to deter mine the coefficients of the nonlinear suspension stiffness by measuring the resonance frequencies at several quiescent points. The coefficients of the nonlinear force factor are then determined by fitting the curve which is calculated from the waveforms of input voltage and input current, and the displacement of the diaphragm at resonance frequency.

  • PDF

A Study On the Property and Influence Factor in Measuring of the Dynamic Stiffness of Damping Materials (바닥충격음 완충재의 동탄성계수 특성 및 측정 영향인자)

  • Kim, Kyoung-Woo;Choi, Hyon-Jung;Kang, Jae-Sik;Yang, Kwan-Seop
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1256-1259
    • /
    • 2006
  • The purpose of this study was to investigate the current status and influence factor in measuring the dynamic stiffness of damping materials. The property of the dynamic stiffness of damping materials was tested and analysed in condition such as the size of test samples and the change of relative humidity in heating chamber. Test results showed that the dynamic stiffness of after-heating was lower than that of before-heating in most samples and the change of relative humidity in heating chamber got little influence of the dynamic stiffness. The resonant frequency of test sample decreased $2{\sim}7Hz$ as the decrease of the size of sample. Because it was increased that total mass per unit area of sample, the change of dynamic stiffness had little influence.

  • PDF

Lateral stiffness of reinforced concrete flat plates with steps under seismic loads

  • Kim, Sanghee;Kang, Thomas H.K.;Kim, Jae-Yo;Park, Hong-Gun
    • Earthquakes and Structures
    • /
    • v.7 no.5
    • /
    • pp.891-906
    • /
    • 2014
  • The purpose of this study is to propose a modification factor to reflect the lateral stiffness modification when a step is located in flat plates. Reinforced concrete slabs with steps have different structural characteristics that are demonstrated by a series of structural experiment and nonlinear analyses. The corner at the step is weak and flexible, and the associated rotational stiffness degradation at the corner of the step is identified through analyses of 6 types of models using a nonlinear finite element program. Then a systematic analysis of stiffness changes is performed using a linear finite element procedure along with rotational springs. The lateral stiffness of reinforced concrete flat plates with steps is mainly affected by the step length, location, thickness and height. Therefore, a single modification factor for each of these variables is obtained, while other variables are constrained. When multiple variables are considered, each single modification factor is multiplied by the other. Such a method is verified by a comparative analysis. Finally, a complex modification factor can be applied to the existing effective slab width.

Assessment of the Stiffness factor of the Separator Plate at the Elevated Temperature (연료전지 분리판의 고온 강성 인자 연구)

  • Kim, J.H.;Woo, D.U.;Lee, S.W.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2007.10a
    • /
    • pp.296-299
    • /
    • 2007
  • The focus of this study is to estimate the stiffness factor of the separator plate of MCFC (Molten Carbonate Fuel Cell) at the elevated temperature. The process factors affecting the stiffness of the separator plate were chosen to determine the most important factor using the finite element analysis with the Taguchi method. The most influential factor, picked out by the ANOYA, turned out the pitch in the separator plate.

  • PDF

A Study on Relationship between Track Impact Factor and Track Support Stiffness of Turnout System on Urban Transit (도시철도 분기기 궤도구조의 궤도지지강성과 궤도충격계수의 상관관계에 관한 연구)

  • Choi, Jung-Youl;Park, Jong-Yoon;Lee, Kyu-Yong;Chung, Jee Seung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.2
    • /
    • pp.461-466
    • /
    • 2020
  • In this study, the relationship between the track support stiffness and the track impact factor for a sleeper floating track and a turnout system with wood ties currently employed in Korean urban transit was assessed by performing field tests using actual vehicles running along the service lines. Field tests were performed on four track systems (i.e., sleeper floating track, and point, lead and crossing sections of turnout system). The theoretically designed track impact factor and track support stiffness were compared with the corresponding track impact factor and track support stiffness measured through field tests for the target tracks on the service line. The track impact factor for the service line appeared to increase with the deviation of track support stiffness according to vehicle driving direction; therefore, it was inferred that the deviation of track support stiffness between each track section directly affected the track impact factor.

Design strategy of hybrid stay cable system using CFRP and steel materials

  • Xiong, Wen;Cai, C.S.;Xiao, Rucheng;Zhang, Yin
    • Steel and Composite Structures
    • /
    • v.13 no.1
    • /
    • pp.47-70
    • /
    • 2012
  • To enhance cable stiffness, this paper proposed a combined application of carbon fiber reinforced polymers (CFRP) and steel materials, resulting in a novel type of hybrid stay cable system especially for the cable-stayed bridges with main span lengths of 1400~2800 m. In this combination, CFRP materials can conserve all their advantages such as light weight and high strength; while steel materials help increase the equivalent stiffness to compensate for the low elastic modulus of CFRP materials. An increase of the equivalent stiffness of the hybrid stay cable system could be further obtained with a reasonable increase of its safety factor. Following this concept, a series of parametric studies for the hybrid stay cable system with the consideration of stiffness and cost were carried out. Three design strategies/criteria, namely, best equivalent stiffness with a given safety factor, highest ratio of equivalent stiffness to material cost with a given safety factor, and best equivalent stiffness under a given cost were proposed from the stiffness and cost viewpoints. Finally, a comprehensive design procedure following the proposed design strategies was suggested. It was shown that the proposed hybrid stay cable system could be a good alternative to the pure CFRP or traditional steel stay cables in the future applications of super long span bridges.

The Correlation of Pulse Wave Velocity and Atherosclerotic Risk Factor in Stroke Patients

  • Jin, Bok Hee;Han, Min Ho
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.47 no.1
    • /
    • pp.28-34
    • /
    • 2015
  • Pulse wave velocity (PWV) is used to non-invasively estimate the severity of arteriosclerosis by measuring arterial stiffness. Increased arterial stiffness measured by PWV stands for progressive arteriosclerosis and is caused by atherosclerotic risk factors. This study is focused on how brachial-ankle pulse wave velocity (baPWV) is related to the leading risk factors for arteriosclerosis or atherosclerosis. Subjects were 114, 69 males and 45 females who are in 60's and had baPWV test for acute stroke. The results are as follows: the group with increased arterial stiffness showed significant increase in HbA1c, total cholesterol, BSBP (brachial artery systolic blood pressure), BDBP (brachial artery diastolic blood pressure), CSBP (central artery systolic blood pressure), CDBP (central artery diastolic blood pressure), augmentation index (AIx) and diabetes mellitus. Correlation analysis between baPWV and atherosclerotic risk factor showed significant relationship in age, HbA1c, LDL cholesterol, BSBP, BDBP, CSBP, CDBP and augmentation index. baPWV was independently related to age and BSBP in multiple linear regression analysis. The group with increased arterial stiffness was independently related to BDBP in multiple logistic regression analysis. This study might be meaningful in evaluating the relationship between arterial stiffness and atherosclerotic risk factor in a new way, and be helped to make various studies for cardiovascular disease.

A Study for Mutual Interference between Symmetric Circular Inclusion and Crack in Finite Width Plate by Boundary Element Method (경계요소법에 의한 유한폭 판재내의 대칭 원형함유물과 균열의 상호간섭에 대한 연구)

  • Park, S.O.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.8
    • /
    • pp.137-145
    • /
    • 1997
  • A two-dimensional program for the analysis of bimaterial inclusion has been developed using the bound- ary element method. In order to study the effects of circular inclusion on the stress field of the crack tip, numerical analysis was performed for the straight crack of finite length around the symmetric circular inclusion whose modulus of elasticity was different from that of the matrix material. In the case of inclusion whose stiffness was smaller than that of the matrix material, the stress intensity factor was found to increase as the crack enamated. The stress intensity factor was uninfluenced from the radial change in inclusion and remained constant for the stiffness equivalent to the matrix materials, where as it decreased for the inclusion with larger stiffness. For the vareation in the distance of the inclusion, a small increase in the stress intensity factor was observed for the case with small or equal stiffness compared with the matrix materials. The inclusion with larger stiffness showed a gradual decrease in the strss intensity factor as the crack emanated.

  • PDF