• 제목/요약/키워드: stiffness

검색결과 10,291건 처리시간 0.049초

정규화된 OEE를 이용한 지진격리장치의 이력거동 추정 (Estimation of Hysteretic Behaviors of a Seismic Isolator Using a Regularized Output Error Estimator)

  • 박현우;전영선;서정문
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 춘계 학술발표회논문집
    • /
    • pp.85-92
    • /
    • 2003
  • Hysteretic behaviors of a seismic isolator are identified by using the regularized output error estimator (OEE) based on the secant stiffness model. A proper regularity condition of tangent stiffness for the current OEE is proposed considering the regularity condition of Duhem hysteretic operator. The proposed regularity condition is defined by 12-norm of the tangent stiffness with respect to time. The secant stiffness model for the OEE is obtained by approximating the tangent stiffness under the proposed regularity condition by the secant stiffness at each time step. A least square method is employed to minimize the difference between the calculated response and measured response for the OEE. The regularity condition of the secant stiffness is utilized to alleviate ill-posedness of the OEE and to yield numerically stable solutions through the regularization technique. An optimal regularization factor determined by geometric mean scheme (GMS) is used to yield appropriate regularization effects on the OEE.

  • PDF

The Influence of Walking on the Crural Muscle Tone and Stiffness in Pronated Foot

  • Wang, Joong San
    • 국제물리치료학회지
    • /
    • 제9권2호
    • /
    • pp.1486-1489
    • /
    • 2018
  • This study aimed to investigate the influence of walking on crural muscle tone and stiffness in individuals with bilateral pronated foot. This study consisted of 16 healthy male. Subjects were divided into a pronated foot group (n = 8) and a normal foot group (n = 8). The navicular drop test on both foot and muscle tone and stiffness in tibialis anterior muscle, medial gastrocnemius muscle, and peroneus longus muscle of both lower extremities were measured before and after 30 min of walking. In this study, the measured navicular drop test before walking was significantly different between pronated foot group and a normal group(p < .05). After 30 min of walking, significantly, increased medial gastrocnemius muscle stiffness of the non-dominant leg was found in the pronated foot group (p < .05). However, there was no significant difference in medial gastrocnemius muscle stiffness between the two groups (p > .05). Based on this study, pronated foot needs to be managed to prevent the abnormally increased medial gastrocnemius muscle stiffness.

프레임의 강성을 고려한 최적 아웃리거 위치의 제안 (Proposal for Optimal Outrigger Location Considering Stiffness of Frame)

  • 김형기
    • 대한건축학회논문집:구조계
    • /
    • 제35권9호
    • /
    • pp.183-190
    • /
    • 2019
  • This paper intended to propose the optimal outrigger position in tall building. For this purpose, a schematic structure design of 70 stories building was accomplished by using MIDAS-Gen. In this analysis research, the key variables were the stiffness of outrigger, the stiffness of frame, the stiffness of shear wall, the stiffness of exterior column connected in outrigger and the outrigger location in height. With the intention of looking for the optimum location of outrigger system in high-rise building, we investigated the lateral displacement in top floor. The study proposed the new method to predict the optimal location of outrigger system considering the frame stiffness. And it is verified that the paper results can be helpful in providing the important engineering materials for finding out the optimum outrigger position in tall building.

Determination of shear stiffness for headed-stud shear connectors using energy balance approach

  • Ye, Huawen;Huang, Ruosen;Tang, Shiqing;Zhou, Yu;Liu, Jilin
    • Steel and Composite Structures
    • /
    • 제42권4호
    • /
    • pp.477-487
    • /
    • 2022
  • The shear stiffness of headed-stud shear connectors has no unified definition due to the nonlinear characteristics of its load-slip relationship. A unified framework was firstly adopted to develop a general expression of shear load-slip equation for headed-stud shear connectors varying in a large parameter range based on both force and energy balance. The pre- and post-yield shear stiffness were then determined through bilinear idealization of proposed shear load-slip equation. An updated and carefully selected push-out test database of 157 stud shear connectors, conducting on studs 13~30mm in diameter and on concretes 30~180 MPa in cubic compressive strength, was used for model regression and sensitivity analysis of shear stiffness. An empirical calculation model was also established for the stud shear stiffness. Compared with the previous models through statistical analysis, the proposed model demonstrates a better performance to predict the shear load-slip response and stiffness of the stud shear connectors.

점성 감쇠기를 이용한 인접 비대칭 강성 구조물의 내진보강 최적설계 (Optimal Seismic Reinforcement Design of Adjacent Asymmetric-Stiffness Structures with Viscous Dampers)

  • 성은희
    • 한국안전학회지
    • /
    • 제37권6호
    • /
    • pp.60-70
    • /
    • 2022
  • This paper proposes an optimal design method of a seismic reinforcement system for the seismic performance of adjacent asymmetric-stiffness structures with viscous dampers. The first method considers plan asymmetry for efficient seismic reinforcement, and evaluates the seismic performance of optimal design applied to two cases of modeling: adjacent stiffness-asymmetric structures and adjacent stiffness-symmetric structures. The second method considers the response of asymmetric structures to derive the optimal objective function, and evaluates seismic efficiency of the objective function applied to two cases of responses: horizontal displacement and torsion. Numerical analyses are conducted on 7- and 10-story structures with a uni-asymmetric-stiffness plan using six cases of historic earthquakes, normalized to 0.4g. The results indicate that the seismic performance is excellent as modeled by adjacent asymmetric-stiffness structures and how much horizontal displacement is applied as the objective function.

합성형교의 외측강성 영향 평가 (Evaluation on the Edge Stiffening Affect of Composite Girder Bridge)

  • 성기태;박영훈;이승용
    • 대한토목학회논문집
    • /
    • 제28권2A호
    • /
    • pp.179-186
    • /
    • 2008
  • 강성비를 이용한 합성형교 외측강성 영향 평가의 타당성을 평가하기 위하여 동일 강성비에서 거더 간격 변화에 따른 수정계수를 해석적으로 분석하였으며, 강성비, 하중 형태, 거더 간격이 수정계수에 미치는 영향을 평가하였다. 현장재하시험 및 기존 설계법의 수정계수와 본 연구에서 분석된 수정계수를 비교한 결과 강성비를 이용한 외측강성 영향 평가가 가능한 것으로 판단된다.

Biomimetic Hopping Strategy for Robots

  • Sung, S.H.;Youm, Y.;Chung, W.K.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.2654-2659
    • /
    • 2003
  • In this paper, we present biomimetic hopping strategy which is more human-like for legged robot through stiffness modulation. Stiffness value is calculated from the motion of body center of gravity. This method enable to reduce impact force on touch-down, adaption on ground stiffness change and height modulation. Simple selected models will be used to validate this method. For general model, singular perturbation is used for control and simulation using stiffness modulation is presented.

  • PDF

거주공간에서 뜬바닥 구조에 사용하는 동탄성계수 측정방법 (Determination of dynamic stiffness of materials used under floating floors in dwellings)

  • 정갑철;오양기;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.945-949
    • /
    • 2002
  • This part of specifies the method for determining the dynamic stiffness of resilient materials used under floating floors. Dynamic stiffness is one of the parameters that determine the sound insulation of such floors in dwellings. This part applies to the determination of dynamic stiffness per unit area of resilient materials with smooth surfaces used in a continuous layer under floating floors in dwellings

  • PDF

주기적인 강성분포를 갖는 구형쉘의 좌굴해석 (Buckling Analysis of Spherical Shells With Periodic Stiffness Distribution)

  • 정환목
    • 한국공간구조학회논문집
    • /
    • 제4권4호
    • /
    • pp.77-84
    • /
    • 2004
  • Researches on spherical shell which is most usually applied have been completed by many investigators already and generalized numerical formula was derived. But the existent researches are limited to those on spherical shell with isotropic or orthotropic roof stiffness, periodic distribution of roof stiffness that can be caused by spherical and latticed roof system is not considered. Therefore, the object of this study is to develop a structural analysis program to analyze spherical shells that have periodicity of roof stiffness distribution caused by latticed roof of large space structure, grasp buckling characteristics and behavior of structure.

  • PDF

너비감소 판형 홀다운스프링 집합체의 탄성강성도 평가 (Estimation of the Elastic Stiffness of TW-HDS Assembly)

  • 송기남
    • 대한기계학회논문집A
    • /
    • 제21권1호
    • /
    • pp.180-187
    • /
    • 1997
  • A formula for estimating the elastic stiffness of TW-HDS with a uniformly tapered width from w$_{0}$ to w$_{1}$ over the length, has been analytically derived based on Euler beam theory and Castigliano's theorem. Elastic stiffnesses of the TW-HDSs designed in the same dimensional design spaces as the KOFA HDSs have been estimated from the derived formula, in addition, a sensitivity study on the elastic stiffness of the TW-HDSs has been carried out. Analysis results show that elastic stiffnesses of the TW-HDSs have been by far higher than those of the KOFA HDSs, and that, as the effects of axial and shear force on the elastic stiffness have been 0.15-0.21%, most of the elastic stiffness is attributed to the bending moment. As a result of sensitivity analysis, the elastic stiffness sensitivity at each design variable is quantified and design variables having remarkable sensitivity are identified. Among the design variables, leaf thickness is identified as that of having the most remarkable sensitivity of the elastic stiffness.