• Title/Summary/Keyword: stick

Search Result 885, Processing Time 0.028 seconds

Implementation of Smart USB Memory based on Bluetooth (블루투스 기반 스마트 USB 메모리 구현)

  • Kang, Byeong-gwan;Woo, Seung-heon;Yu, Hyun-ju;Ju, Haein;Lee, Ju-won;Kang, Seong-in
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.522-524
    • /
    • 2015
  • A USB memory stick became common for secondary storage Unit.. But USB memory stick has critical problems as well. Such as personal information data leakage due to easy loss of the portable device. Therefore, User increased Repurchases of USB memory stick, and damage case of personal and company information data leakage increased. In this study, to prevent such loss and stolen, we propose Smart USB memory stick based on Bluetooth. Smart USB memory stick support the security and prevent the loss.

  • PDF

Characterization and Comparison of Oriental Ink Sticks (동양 전통 먹(墨)의 이화학적 성상 비교 분석)

  • Kim, Kang-Jae;Eom, Tae-Jin
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.40 no.4
    • /
    • pp.74-81
    • /
    • 2008
  • The writing brush, ink stick, paper, and ink stone were the four precious things of the studying and recording in oriental world until even nowaday. The oriental paper was comparatively well evaluated in many papers and reviews, but it is difficult to find some scientific reports or reviews about the ink stick. In this paper, the scientific aspect of ink sticks of oriental maine three country(Korea, China, Japan) were evaluated by the physical, chemical and microscopic analysis. The result could summarized as fellows; 1. The Korean lampblack ink stick contains more carbon and less nitrogen and the Chinese ink sticks contain less carbon and more oxygen. 2. The Korean lampblack and cowhide glue contain relatively higher amount of sulphur. 3. The particle size distribution of carbon in the ink stick was not change after grinding in the ink stone. 4. The particle size of carbon and the pore size in the charcoal ink sticks of three country were larger than those of the lampblack ink sticks. 5. The ink solution of the charcoal ink sticks shows high roundness on Hanji while the ink solution of the lampblack ink sticks is spread readily to Hanji surface. 6. The change of whiteness in printing of the ink sticks is notable in thermal treatment.

Contact Stress Analysis of Stick Type Ignition Coil Jacket PET (Stick Type Ignition Coil Jacket PET의 접촉응력 해석)

  • Kim Yang-Sul
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.1 s.69
    • /
    • pp.1-6
    • /
    • 2005
  • Stick type ignition coil is new development that connect directly with ECU(Electronic control unit), without needing a spark plug cable and distributor. Glass-fiber reinforced ploymeric composites provide the desirable properties of high stiffness and strength as well as low specific weight. Stick type ignition coil jacket is using PBT CF30 resin. PBT CF30 resin is a kind of electric insulation which is a superior engineering plastic that is used to prevent the leakage of the electrical current. If PET receive a mistake of design or excessive force when HV terminal oppress on jacket, it can happen to crack. Local stress concentrations occurring on the contact surface, the contact phenomenon becomes a direct cause to the wear and failure of mechanical structures. When it is cracked, it can allow a leakage of the electrical current. So, in this study, we analyze the contact stress to PBT jacket using ANSYS program, when HV terminal oppress on jacket. We suppose PBT to be Jacket and we analyzed contact stress that happens in PET like PBT analysis method. We compared the use of PBT and PET.

Incidence of the Needle-Stick Injuries in Medical Students Among Clinical Training (임상실습(臨床實習)중인 의과대학생(醫科大學生)들의 주사침(注射針) 상해(傷害)(needle-stick injury) 발생율(發生率))

  • Park, Wan-Seoup;No, Yun-Kyung;Lee, Jong-Young;Kim, Doo-Hie
    • Journal of Preventive Medicine and Public Health
    • /
    • v.27 no.3 s.47
    • /
    • pp.403-409
    • /
    • 1994
  • A questionnaire survey wds conducted to assess the experience of the needle stick injury in 144 seniors of a medical school during the previous 10 months. One hundred and five of them (73%) had responded. About sixty-nine percent (72 cases) of the respondents had suffered at least one u and there had been 129 injuries in total. Seventy-eight (56.6%) of the injuries took place at the time of the venipuncture. The emergency and operating room incurred 76.7% and 23.3% of the injury, respectively. Injuries with bleeding account for 50.4%. None of the respondents was systematically educated about the prevention of injury. This survey shows that the needle-stick Injury is a great risk for the medical students' health, and that educational effort for its prevention is warranted.

  • PDF

Development of the Air Stick Feeder for Inserting the Relay (릴레이 삽입을 위한 에어 스틱 피더의 개발)

  • Kim, Young-Min;Kim, Chi-Su
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.2
    • /
    • pp.1398-1402
    • /
    • 2015
  • In surface mount technology, the use of technology implemented using a Chip Mounter relay that is inserted into the junction box, etc. car is increasing. On the other hand, there is a need for technology to reduce the weight of the heavy component of the relay attached to different Stick Tube generally chips. Therefore, rather than existing technology, this study improved the algorithm of the system to provide a mechanical structure using Air to supply greater stability using this the component feeder utilizing the Stick Tube proposed technology. When the equipment installed in the Air Stick Feeder was used, the effectiveness, such as increased production and reduced disposal expense, was improved.

Micro-positioning of a Smart Structure Using an Enhanced Stick-slip Model (향상된 스틱-슬립 마찰 모델을 이용한 스마트 구조물의 마이크로 위치제어)

  • Lee, Chul-Hee;Jang, Min-Gyu;Choi, Seung-Bok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.11
    • /
    • pp.1134-1142
    • /
    • 2008
  • In this paper, a model-based stick-slip compensation for the micro-positioning is proposed using an enhanced stick-slip model based on statistical rough surface contact model. The smart structure is comprised with PZT(lead (Pb) zirconia(Zr) Titanate(Ti)) based stack actuator incorporating with the PID(proportional-integral-derivative) control algorithm, mechanical displacement amplifier and positioning devices. For the stick-slip compensation, the elastic-plastic static friction model is used considering the elastic-plastic asperity contact in the rough surfaces statistically. Mathematical model of system for the positioning apparatus was derived from the dynamic behaviors of structural parts. PID feedback control algorithms with the developed stick-slip model as well as feedforward friction compensator are formulated for achieving the accurate positioning performance. Experimental results are provided to show the performances of friction control using the developed positioning apparatus.

Comparison of Seismic Responses of Updated Lumped-Mass Stick Model and Shaking Table Test Results (업데이트된 집중질량스틱모델과 진동대실험 지진응답 비교)

  • Sun, Hwichang;Hong, Sanghyun;Roh, Hwasung
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.23 no.4
    • /
    • pp.231-238
    • /
    • 2019
  • A conventional lumped-mass stick model is based on the tributary area method to determine the masses lumped at each node and used in earthquake engineering due to its simplicity in the modeling of structures. However the natural frequencies of the conventional model are normally not identical to those of the actual structure. To solve this problem, recently an updated lumped-mass stick model is developed to provide the natural frequencies identical to actual structure. The present study is to investigate the seismic response accuracy of the updated lumped-mass stick model, comparing with the response results of the shaking table test. For the test, a small size four-story steel frame structure is prepared and tested on shaking table applying five earthquake ground motions. From the comparison with shaking table test results, the updated model shows an average error of 3.65% in the peak displacement response and 9.68% in the peak acceleration response. On the other hand, the conventional model shows an average error of 5.15% and 27.41% for each response.

Design and Evaluation of a Control Stick for Weapon Systems Using RS-422 Communication and an Embedded Processor (RS-422 통신과 임베디드 프로세서를 이용한 무장 조종간의 설계 및 평가)

  • Young-Jun Lee
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.19 no.4
    • /
    • pp.647-654
    • /
    • 2024
  • In military weapon systems, control sticks for weapon operation are essential. This paper presents the design and performance evaluation of a control stick for weapon systems using RS-422 communication and an embedded processor. This control stick is ergonomically designed, considering the hand dimensions of Korean pilots and mission convenience. The circuitry and software based on RS-422 communication were designed using an embedded processor. A prototype of the control stick was manufactured and subjected to a series of tests, including basic performance tests and various environmental tests such as altitude, high temperature, low temperature, temperature shock, humidity, rain, vibration shock, and acceleration, all of which met the required standards.

Modeling of flexible stick balencer and controller design (Flexible stick balencer에 대한 modeling과 제어에 관한 연구)

  • Seo, Ki-Won;Cho, Hwang
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.233-236
    • /
    • 1996
  • This paper describes a liner state-space model for a flexible stick balencer. The method employed to generate the model utilizes a separable formulation of assumed modes to represents the transverse displacement due to bending Lagrangian dynamics are applied to determine the kinetic and potential energies for the system. The resultant dynamic equations are then organized into a state space model and linearized using Taylor series expansion method. A minimum order observer is designed to estimate unmeasurable states.

  • PDF