• Title/Summary/Keyword: stereotactic radiotherapy

Search Result 124, Processing Time 0.021 seconds

Skin Dose Comparison of CyberKnife and Helical Tomotherapy for Head-and-Neck Stereotactic Body Radiotherapy

  • Yoon, Jeongmin;Park, Kwangwoo;Kim, Jin Sung;Kim, Yong Bae;Lee, Ho
    • Progress in Medical Physics
    • /
    • v.30 no.1
    • /
    • pp.1-6
    • /
    • 2019
  • Purpose: This study conducts a comparative evaluation of the skin dose in CyberKnife (CK) and Helical Tomotherapy (HT) to predict the accurate dose of radiation and minimize skin burns in head-and-neck stereotactic body radiotherapy. Materials and Methods: Arbitrarily-defined planning target volume (PTV) close to the skin was drawn on the planning computed tomography acquired from a head-and-neck phantom with 19 optically stimulated luminescent dosimeters (OSLDs) attached to the surface (3 OSLDs were positioned at the skin close to PTV and 16 OSLDs were near sideburns and forehead, away from PTV). The calculation doses were obtained from the MultiPlan 5.1.2 treatment planning system using raytracing (RT), finite size pencil beam (FSPB), and Monte Carlo (MC) algorithms for CK. For HT, the skin dose was estimated via convolution superposition (CS) algorithm from the Tomotherapy planning station 5.0.2.5. The prescribed dose was 8 Gy for 95% coverage of the PTV. Results and Conclusions: The mean differences between calculation and measurement values were $-1.2{\pm}3.1%$, $2.5{\pm}7.9%$, $-2.8{\pm}3.8%$, $-6.6{\pm}8.8%$, and $-1.4{\pm}1.8%$ in CS, RT, RT with contour correction (CC), FSPB, and MC, respectively. FSPB showed a dose error comparable to RT. CS and RT with CC led to a small error as compared to FSPB and RT. Considering OSLDs close to PTV, MC minimized the uncertainty of skin dose as compared to other algorithms.

Dosimetric Analysis of Lung Stereotactic Body Radiotherapy Using Halcyon Linear Accelerator

  • Shinhaeng Cho;Ick Joon Cho;Yong Hyub Kim;Jea-Uk Jeong;Mee Sun Yoon;Taek-Keun Nam;Sung-Ja Ahn;Ju-Young Song
    • Progress in Medical Physics
    • /
    • v.34 no.4
    • /
    • pp.48-54
    • /
    • 2023
  • Purpose: In this study, the dosimetric characteristics of lung stereotactic body radiotherapy (SBRT) plans using the new Halcyon system were analyzed to assess its suitability. Methods: We compared the key dosimetric parameters calculated for the Halcyon SBRT plans with those of a conventional C-arm linear accelerator (LINAC) equipped with a high-definition multileaf collimator (HD-MLC)-Trilogy Tx. A total of 10 patients with non-small-cell lung cancer were selected, and all SBRT plans were generated using the RapidArc technique. Results: Trilogy Tx exhibited significant superiority over Halcyon in terms of target dose coverage (conformity index, homogeneity index, D0.1 cc, and D95%) and dose spillage (gradient). Trilogy Tx was more efficient than Halcyon in the lung SBRT beam delivery process in terms of the total number of monitor units, modulation factor, and beam-on time. However, it was feasible to achieve a dose distribution that met SBRT plan requirements using Halcyon, with no significant differences in satisfying organs at risk dose constraints between both plans. Conclusions: Results confirm that Halcyon is a viable alternative for performing lung SBRT in the absence of a LINAC equipped with HD-MLC. However, extra consideration should be taken in determining whether to use Halcyon when the planning target volume setting is enormous, as in the case of significant tumor motions.

Feasibility and Efficacy of Adaptive Intensity Modulated Radiotherapy Planning according to Tumor Volume Change in Early Stage Non-small Cell Lung Cancer with Stereotactic Body Radiotherapy (폐암의 정위적체부방사선치료에서 육안적종양체적 변화에 따른 적응방사선치료의 효용성 및 가능성 연구)

  • Park, Jae Won;Kang, Min Kyu;Yea, Ji Woon
    • Progress in Medical Physics
    • /
    • v.26 no.2
    • /
    • pp.79-86
    • /
    • 2015
  • The purpose of this study is to evaluate efficacy and feasibility of adaptive radiotherapy according to tumor volume change (TVC) in early stage non-small cell lung cancer (NSCLC) using stereotactic body radiotherapy (SBRT). Twenty-two lesions previously treated with SBRT were selected. SBRT was usually performed with a total dose of 48 Gy or 60 Gy in four fractions with an interval of three to four days between treatments. For evaluation of TVC, gross tumor volume (GTV) was contoured on each cone-beam computed tomography (CBCT) image used for image guidance. Intensity modulated radiotherapy (IMRT) planning was performed in the first CBCT (CBCT1) using a baseline plan. For ART planning (ART), re-optimization was performed at $2^{nd}$, $3^{rd}$, and $4^{th}$ CBCTs (CBCT2, CBCT3, and CBCT4) using the same angle and constraint used for the baseline plan. The ART plan was compared with the non-ART plan, which generated copying of the baseline plan to other CBCTs. Average GTV volume was 10.7 cc. Average TVC was -1.5%, 7.3%, and -25.1% in CBCT2, CBCT3, and CBCT4 and the TVC after CBCT3 was significant (p<0.05). However, the nine lesions were increased GTV in CBCT2. In the ART plan, $V_{20\;Gy}$, $D_{1500\;cc}$, and $D_{1000\;cc}$ of lung were significantly decreased (p<0.05), and $V_{30\;Gy}$ and $V_{32\;Gy}$ of the chest wall were also decreased (p<0.05). While D min of planning target volume (PTV) decreased by 8.3% in the non-ART plan of CBCT2 compared with the baseline plan in lesions with increased tumor size (p=0.021), PTV coverage was not compromised in the ART plan. Based on this result, use of the ART plan may improve target coverage and OAR saving. Thus ART using CBCT should be considered in early stage NSCLC with SBRT.

Preliminary Results of Fractionated Stereotactic Radiotherapy for Benign Brain Tumors (양성 뇌종양에 대한 분할 정위 방사선치료의 예비 결과)

  • Choi, Byung-Ock;Kang, Ki-Mun
    • Radiation Oncology Journal
    • /
    • v.21 no.1
    • /
    • pp.10-18
    • /
    • 2003
  • Purpose : To evaluate the role of fractlonated sterotactic radiotherapy (FSRT) in the management of benign brain tumors, we reviewed the clinical, and radiographic responses of patients treated. Methods and Materials : Between March 1995 and March 2002, 36 patients with benign brain tumors were treated by FSRT. The pathological diagnoses consisted of pituitary adenomas (12 patients), cranio-pharyngiomas (5 patients), meningiomas (10 patients), and acoustic neurinomas (9 patients). Radiotherapy doses of 25 to 35 Gy (3~6 Gy/fraction, 5~10 fractions) were prescribed to the 85~90% isodose line, depending upon the location, size and volume of the tumors. The median clinical and radiographical follow up periods were 31 (range, 2~74) and 21 (range, 4~56) months, respectively. Results : In the 35 patients that could be evaluated for their clinical response, 13 (37.1%) were considered improved, 16 (45.7%) stable and 6 (17.2%) worse. Of the 33 patients who had radiographic studies, tumor shrinkage was noted in 17 (51.5%), tumor stabilization in 13 (39.4%), and tumor progression in 3 (9.1%). Of the 17 tumor shrinkage patients, 7 (21.2%) showed a complete response. Acute radiation-induced complications occurred iin 11 (30.6%) patients. Conclusions : FSRT is considered a safe and effective treatment method for begin brain tumors, but large numbers of patients, with relatively long follow-up periods are needed to assess the exact role or effect of FSRT.

Study of Dynamic Variation Aspect in Lung Volume due to Respiration in Stereotactic Body Radiotherapy Using Abdominal Compressor (복부압박장치를 이용한 정위적방사선치료 시 호흡에 따른 폐암 용적의 동적변이 양상에 대한 연구)

  • Park, Kwang Soon;Kim, Joo Ho;Park, Hyo Kook;Beak, Jong Geal;Lee, Sang Kyoo;Yoon, Jong Won;Cho, Jeong Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.159-165
    • /
    • 2013
  • Purpose: Abdominal compressor is used to control breathing in stereotactic body radiotherapy for lung tumors frequently. We evaluated the dynamic variation aspect of internal tumor volume by breathing. Materials and Methods: We reviewed 20 lung cancer patients (7 upper lung patients, 4 middle lung patients, 9 lower lung patients) who received stereotactic body radiotherapy using abdominal compressor between April 2012 to April 2013. Coordinate shift values were obtained by using four-dimensional cone-beam CT (4D-CBCT) to investigate treatment set-up error and moving tumor position error. To investigate how much difference of each part, we compared 95% confidence interval, maximum values and minimum values of three-dimensional vector value and analyzed conformity degree through the Pearson square correlation coefficient. Results: 95% confidence interval of three-dimensional vector value of each part is 1.8~2.9 mm in upper lobe, 2.3~5.4 mm in middle lobe and 2.2~4.0 mm in lower lobe. Conformity degree was the result that respectively is LR direction 0.75, SI direction 0.68 and AP direction 0.63 in upper lobe, LR direction 0.82, SI direction 0.51 and AP direction 0.92 in middle lobe and LR direction 0.63, SI direction 0.50 and AP direction 0.34 in lower lobe. Conclusion: We showed difference by each site in lung tumor due to respiration by using abdominal compressor. Therefore, we must correct treatment set-up error as well as moving tumor position error by breathing. It is also considered to be useful that it is the use of 4D-CBCT when correcting the error due to various dynamic variation.

  • PDF

Comparison of Anisotropic Analytic Algorithm Plan and Acuros XB Plan for Lung Stereotactic Ablative Radiotherapy Using Flattening Filter-Free Beams (비편평화여과기 빔을 이용한 폐 정위절제방사선치료를 위한 AAA와 Acuros XB 계산 알고리즘의 치료계획 비교)

  • Chung, Jin-Beom;Eom, Keun-Yong;Kim, In-Ah;Kim, Jae-Sung;Lee, Jeong-Woo;Hong, Semie;Kim, Yon-Lae;Park, Byung-Moon;Kang, Sang-Won;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.210-217
    • /
    • 2014
  • This study investigated the dosimetric effects of different dose calculation algorithm for lung stereotactic ablative radiotherapy (SABR) using flattening filter-free (FFF) beams. A total of 10 patients with lung cancer who were treated with SABR were evaluated. All treatment plans were created using an Acuros XB (AXB) of an Eclipse treatment planning system. An additional plans for comparison of different alagorithm recalcuated with anisotropic analytic algorithm (AAA) algorithm. To address both algorithms, the cumulative dose-volume histogram (DVH) was analyzed for the planning target volume (PTV) and organs at risk (OARs). Technical parameters, such as the computation times and total monitor units (MUs), were also evaluated. A comparison analysis of DVHs from these plans revealed the PTV for AXB estimated a higher maximum dose (5.2%) and lower minimum dose (4.2%) than that of the AAA. The highest dose difference observed 7.06% for the PTV $V_{105%}$. The maximum dose to the lung was also slightly larger in the AXB plans. The percentate volumes of the ipsilateral lung ($V_5$, $V_{10}$, $V_{20}$) receiving 5, 10, and 20 Gy were also larger in AXB plans than for AAA plans. However, these parameters were comparable between both AAA and AXB plans for the contralateral lung. The differences of the maximum dose for the spinal cord and heart were also small. The computation time of AXB plans was 13.7% shorter than that of AAA plans. The average MUs were 3.47% larger for AXB plans than for AAA plans. The results of this study suggest that AXB algorithm can provide advantages such as accurate dose calculations and reduced computation time in lung SABR plan using FFF beams, especially for volumetric modulated arc therapy technique.

Planning and Dosimetric Study of Volumetric Modulated Arc Based Hypofractionated Stereotactic Radiotherapy for Acoustic Schwannoma - 6MV Flattening Filter Free Photon Beam

  • Swamy, Shanmugam Thirumalai;Radha, Chandrasekaran Anu;Arun, Gandhi;Kathirvel, Murugesan;Subramanian, Sai
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.12
    • /
    • pp.5019-5024
    • /
    • 2015
  • Background: The purpose of this study was to assess the dosimetric and clinical feasibility of volumetric modulated arc based hypofractionated stereotactic radiotherapy (RapidArc) treatment for large acoustic schwannoma (AS >10cc). Materials and Methods: Ten AS patients were immobilized using BrainLab mask. They were subject to multimodality imaging (magnetic resonance and computed tomography) to contour target and organs at risk (brainstem and cochlea). Volumetric modulated arc therapy (VMAT) based stereotactic plans were optimized in Eclipse (V11) treatment planning system (TPS) using progressive resolution optimizer-III and final dose calculations were performed using analytical anisotropic algorithm with 1.5 mm grid resolution. All AS presented in this study were treated with VMAT based HSRT to a total dose of 25Gy in 5 fractions (5fractions/week). VMAT plan contains 2-4 non-coplanar arcs. Treatment planning was performed to achieve at least 99% of PTV volume (D99) receives 100% of prescription dose (25Gy), while dose to OAR's were kept below the tolerance limits. Dose-volume histograms (DVH) were analyzed to assess plan quality. Treatments were delivered using upgraded 6 MV un-flattened photon beam (FFF) from Clinac-iX machine. Extensive pretreatment quality assurance measurements were carried out to report on quality of delivery. Point dosimetry was performed using three different detectors, which includes CC13 ion-chamber, Exradin A14 ion-chamber and Exradin W1 plastic scintillator detector (PSD) which have measuring volume of $0.13cm^3$, $0.009cm^3$ and $0.002cm^3$ respectively. Results: Average PTV volume of AS was 11.3cc (${\pm}4.8$), and located in eloquent areas. VMAT plans provided complete PTV coverage with average conformity index of 1.06 (${\pm}0.05$). OAR's dose were kept below tolerance limit recommend by American Association of Physicist in Medicine task group-101(brainstem $V_{0.5cc}$ < 23Gy, cochlea maximum < 25Gy and Optic pathway <25Gy). PSD resulted in superior dosimetric accuracy compared with other two detectors (p=0.021 for PSD.

Preliminary Result in Patients with Primary Hepatoma Treated by Stereotactic Radiotherapy (원발성 간암에 대한 정위방사선치료의 예비결과)

  • Kang Ki Mun;Choi Ihl Bohng;Kim In Ah;Choi Byung Ock;Kang Young Nam;Chai Gyu Young;Han Sung Tae;Chung Gyu Won
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.34-39
    • /
    • 2001
  • Purpose : It is not common to evaluate the response of the fractionated stereotactic radiotherapy (SRT) to primary hepatoma as compared with conventional radiotherapy. The purpose of the study was to take the preliminary result on the clinical trial of primary hepatoma by SRT. Materials and Methods : From July 1999 to March 2000, thirty three patients were hospitalized in the St. Mary's Hospital, and treated with SRT for extracranial tumors. Among them, 13 patients were diagnosed to primary hepatoma and then applied by frameless SRT using 6 MV linac accelerator. There were 12 male and 1 female patients. They had the age of $ 44\~66$ year old (median : 59) and the tumor size of $10\~825\;cc$ (median : 185 cc). SRT was given to them $3\~5$ fractions a week (5 Gy/fraction, $90\%$ isodose line) for $2\~3$ weeks. Median dose of SRT was 50 Gy and the range was $30\~50\;Gy$. Results : Follow-up period ranged from 3 months to 13 months with median of 8 months. After treating SRT to thirteen patients with primary hepatoma, the response of the tumor was examined by abdominal CT : they are classified by 1 complete regression $(7.7\%)$, 7 partial regression $(53.8\%)$, 4 minimal regression $(30.8\%)$, 1 stable disease $(7.7\%)$. The positive responses more than partial remission were 8 patients $(61.5\%)$ after the treatment. The level of serum alpha-fetoprotein (AFP) after the treatment as compared with pretreatment had been $92.3\%$ decreased. There was no severe complication except dyspepsia $84.6\%$, mild nausea $69.2\%$, transient decreased of hepatic function $15.4\%$ and fever $7.7\%$. Conclusion : SRT to the patients with primary hepatoma was potentially suggested to become the safe and more effective tool than the conventional radiotherapy even though there were relatively short duration of follow-up and small numbers to be tested.

  • PDF

Present Status and Future Aspects of Radiation Oncology in Korea (방사선 치료의 국내 현황과 미래)

  • Huh, Seung-Jae
    • Radiation Oncology Journal
    • /
    • v.24 no.4
    • /
    • pp.211-216
    • /
    • 2006
  • $\underline{Purpose}$: An analysis of the infrastructure for radiotherapy in Korea was performed to establish a baseline plan in 2006 for future development. $\underline{Materials\;and\;Methods}$: The data were obtained from 61 radiotherapy centers. The survey covered the number of radiotherapy centers, major equipment and personnel. Centers were classified into technical level groups according to the IAEA criteria. $\underline{Results}$: 28,789 new patients were treated with radiation therapy in 2004. There were 104 megavoltage devices in 61 institutions, which included 96 linear accelerators, two Cobalt 60 units, three Tomotherapy units, two Cyberknife units and one proton accelerator in 2006. Thirty-five high dose rate remote after-loading systems and 20 CT-simulators were surveyed. Personnel included 132 radiation oncologists, 50 radiation oncology residents, 64 medical physicists, 130 nurses and 369 radiation therapy technologists. All of the facilities employed treatment-planning computers and simulators, among these thirty-two percent (20 facilities) used a CT-simulator. Sixty-six percent (40 facilities) used a PET/CT scanner, and 35% (22 facilities) had the capacity to implement intensity modulated radiation therapy. Twenty-five facilities (41%) were included in technical level 3 group (having one of intensity modulated radiotherapy, stereotactic radiotherapy or intra-operative radiotherapy system). $\underline{Conclusion}$: Radiation oncology in Korea evolved greatly in both quality and quantity recently and demand for radiotherapy in Korea is increasing steadily. The information in this analysis represents important data to develop the future planning of equipment and human resources.

Hypofractionated three-dimensional conformal radiotherapy for medically inoperable early stage non-small-cell lung cancer

  • Lee, Joo Ho;Wu, Hong-Gyun;Kim, Hak Jae;Park, Charn Il;Lee, Se-Hoon;Kim, Dong-Wan;Heo, Dae Seog
    • Radiation Oncology Journal
    • /
    • v.31 no.1
    • /
    • pp.18-24
    • /
    • 2013
  • Purpose: The purpose of this study was to assess the clinical outcomes of hypofractionated radiotherapy (HFRT) with three-dimensional conformal technique for medically inoperable patients with early stage non-small-cell lung cancer (NSCLC) and to evaluate prognostic factors. Materials and Methods: We performed a retrospective review of 26 patients who underwent HFRT for early stage NSCLC between September 2005 and August 2011. Only clinical stage T1-3N0 was included. The median RT dose was 70 Gy (range, 60 to 72 Gy) and the median biologically equivalent dose (BED) was 94.5 Gy (range, 78.0 to 100.8 Gy). In 84.6% of patients, 4 Gy per fraction was used. Neoadjuvant chemotherapy with paclitaxel and cisplatin was given to 2 of 26 patients. Results: The median follow-up time for surviving patients was 21 months (range, 13 to 49 months). The overall response rate was 53.9%, and the initial local control rate was 100%. The median survival duration was 27.8 months. Rates of 2-year overall survival, progression-free survival (PFS), local control (LC), and locoregional-free survival (LRFS) were 54.3%, 61.1%, 74.6%, and 61.9%, respectively. Multivariate analysis showed that BED (>90 vs. ${\leq}90$ Gy) was an independent prognostic factor influencing PFS, LC, and LRFS. Severe toxicities over grade 3 were not observed. Conclusion: Radical HFRT can yield satisfactory disease control with acceptable rates of toxicities in medically inoperable patients with early stage NSCLC. HFRT is a viable alternative for clinics and patients ineligible for stereotactic ablative radiotherapy. BED over 90 Gy and 4 Gy per fraction might be appropriate for HFRT.