• Title/Summary/Keyword: stereoscopic depth

Search Result 195, Processing Time 0.024 seconds

Analysis of Skin Micro-relief on Healthy Korean Youth According to Sex (건강한 한국인 청년에서 성별에 따른 피부표면 미세지형 분석)

  • Kim, Hyun-Wook;Oh, Seung-Hak;Kim, Nam-Sook;Na, Ji-Eun;Lee, Sang-Hoon;Park, In-Sung;Kwon, Soon-Wook;Rhyu, Im-Joo
    • Applied Microscopy
    • /
    • v.42 no.1
    • /
    • pp.35-42
    • /
    • 2012
  • The skin is the largest organ of the integument system whose surface is closely related to many physiological and pathological conditions. The skin surface is closely related to functional status of the epidermis and dermis. The outermost surface of the skin shows characteristic pattern defined by small furrows are called micro-relief. The micro-relief change is according to physiological and pathological conditions of the skin. But, there is no data on health Korean skin micro-relief yet. This study presents some aspect of health Korean skin micro-relief from the twenties. The silicon replicas obtained from forearm, dorsum hand and finger were analyzed by profiles were accessed by stereoscopy. We measured density of furrow, width of furrow, and depth of furrow in micro-relief with sectioned silicon replica sample using stereoscope. Stereoscopic analysis showed that male group has a larger density of furrow and depth furrow in finger significantly. The densities of furrow were shown different not only between forearm and finger but also between finger and hand in male with female group. In conclusion, there were differences results between sex different and regional difference in skin replica profile. These quantitative data can be used for basis of further skin research for Korean.

A STUDY ON THE DISTRIBUTION OF CALCITONIN GENE-RELATED PEPTIDE CONTAINING NERVE FIBERS IN RAT PULP FOLLOWING DENTINAL INJURY (상아질 손상 후 흰쥐 대구치 치수의 calcitonin gene-related peptide(CGRP) 함유 신경섬유 분포에 관한 연구)

  • Moon, Joo-Hoon;Park, Sang-Jin;Min, Byung-Soon;Choi, Ho-Young;Cho, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.1
    • /
    • pp.100-115
    • /
    • 1999
  • The purpose of this study was to investigate the distribution of calcitonin gene-related peptide containing nerve fibers in rat pulp after dentinl injury by means of immunohistochemistry and confocal laser scanning microscope. The Spague-Dawley rats weighing about 250-300gm were used. The animals were devided into normal control and experimental groups. Experimental animals were sacrified 1, 2, 4, 7, 10, 21days after dentinal injury (dentin cutting, and then acid etching with 35% phosphoric acid) on the maxillary molar teeth. The maxillary teeth and alveolar bone were removed and immersed in the 4% paraformaldehyde in 0.1M phosphate buffer (pH 7.4), then were decalcified with 15% formic acid for 10 days. Serial frozen $50{\mu}m$ thick sections were cut on a cryostat. The rabbit CGRP antibody was used as a primary antibody with a dilution of 1:2000 in 0.01M PB. The sections were incubated for 48 hours at $4^{\circ}C$, and placed into biotinylated antirabbit Ig G as a secondary anti body with dilution of 1:200 in 0.01M PB and incubated in ABC(avidin-biotin complex). The peroxidase reaction was visualized by incubating the sections in 0.05% 3,3 diaminobenzidine tetrahydrochloride containing 0.02% $H_2O_2$. For the confocal laser scanning microscopic examination, Primary antibody reaction was same as immunoperoxidase stainning, but fluorescein isothiocyanate(FITC)-conjugate antirabbit IgG as a secondary antibody was used. The confocal laser scanning microscope was used for the examination. A series of images of optical sections was collected with a 20x objective at $3{\mu}m$ intervals throughout the depth of specimen. FITC fluerescence was registrated through a 488nm and 568nm excitation filter, and images were saved on optical disk. The stereoscopic images and three dimentionnal images were reconstructed by computer software, and then were analyzed. The results were as follows : 1. In normal control group, CGRP containing nerve fibers were coursed through the root with very little branching, and then formed a dense network of terminals in coronal pulp. 2. A slight increase in CGRP containing nerve fibers at 1 and 2day postinjury was noted subjacent to the injury site. In the 4day group, there were an extensive increase in the number of reactive fibers, followed by a partial return toward normal levels at 7~10 day postinjury, and return by 21days. 3. The sprouting of the CGRP containing nerve fibers was evident within 2day after dentinal injury, and by 4days there was a maximal increased, but was decreased at 7days and returned to normal 10~21 day postinjury. 4. In confocal laser scanning microscopic exammination, the distinct distribution pattern and sprouting reaction of CGRP containing nerve fibers were observed in stereoscopic images and three dimentional images. These results suggest that CGRP containing nerve fiber can be important role in the response to dental injury and pain regulation.

  • PDF

Applications of the Scanning Electron Microscope (주사형(走査型) 전자현미경(電子顯微鏡)의 응용분야(應用分野))

  • Kim, Yong-Nak
    • Applied Microscopy
    • /
    • v.2 no.1
    • /
    • pp.39-46
    • /
    • 1972
  • There are many kinds of microscopes suitable for general studies; optical microscopes(OM), conventional transmission electron microscopes (TEM), and scanning electron microscopes(SEM). The optical microscopes and the conventional transmission electron microscopes are very familiar. The images of these microscopes are directly formed on an image plane with one or more image forming lenses. On the other hand, the image of the scanning electron microscope is formed on a fluorescent screen of a cathode ray tube using a scanning system similar to television technique. In this paper, the features and some applications of the scanning electron microscope will be discussed briefly. The recently available scanning electron microscope, combining a resolution of about $200{\AA}$ with great depth of field, is favorable when compared to the replica technique. It avoids the problem of specimen damage and the introduction of artifacts. In addition, it permits the examination of many samples that can not be replicated, and provides a broader range of information. The scanning electron microscope has found application in diverse fields of study including biology, chemistry, materials science, semiconductor technology, and many others. In scanning electron microscopy, the secondary electron method. the backscattererd electron method, and the electromotive force method are most widely used, and the transmitted electron method will become more useful. Change-over of magnification can be easily done by controlling the scanning width of the electron probe. It is possible. to continuously vary the magnification over the range from 100 times to 1.00,000 times without readjustment of focusing. Conclusion: With the development of a scanning. electron microscope, it is now possible to observe almost all-information produced through interactions between substances and electrons in the form of image. When the probe is properly focused on the specimen, changing magnification of specimen orientation does not require any change in focus. This is quite different from the conventional transmission electron microscope. It is worthwhile to note that the typical probe currents of $10^{-10}$ to $10^{-12}\;{\AA}$ are for below the $10^{-5}$ to $10^{-7}\;{\AA}$ of a conventional. transmission microscope. This reduces specimen contamination and specimen damage due to heatings. Outstanding features of the scanning electron microscope include the 'stereoscopic observation of a bulky or fiber specimen in high resolution' and 'observation of potential distribution and electromotive force in semiconductor devices'.

  • PDF

Comparison of Microleakage and Compressive Strength of Different Base Materials (여러 치과 와동 기저재용 재료들의 미세누출 및 압축강도 비교)

  • Jang, Eunyeong;Lee, Jaesik;Nam, Soonhyeun;Kwon, Taeyub;Kim, Hyunjung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.2
    • /
    • pp.168-175
    • /
    • 2021
  • This study compared the microleakages and compressive strengths of various base materials. To evaluate microleakages, 50 extracted permanent premolars were prepared. The teeth divided into 5 groups of 10 each according to the base materials. Cavities with a 5.0 mm width, 3.0 mm length, and 3.0 mm depth were formed on the buccal surfaces of the teeth. After filling the cavities with different base materials, a composite resin was used for final restoration. Each specimen was immersed in 2% methylene blue solution and then observed under a stereoscopic microscope (× 30). To evaluate the compressive strength, 5 cylindrical specimens were prepared for each base material. A universal testing machine was used to measure the compressive strength. The microleakage was highest in the Riva light cureTM group and lowest in the BiodentineTM and Well-RootTM PT groups. For the compressive strengths, in all groups, acceptable strength values for base materials were found. The highest compressive strength was observed in the Fuji II LCTM group and the lowest strength in the Well-RootTM PT group.

BONDING OF RESIN INLAY TO GLASS-IONOMER BASE WITH VARIOUS TREATMENTS ON INLAY SURFACE (내표면 처리에 따른 레진 인레이와 글래스아이오노머 베이스간의 접착)

  • Jang, Byung-Sung;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.3
    • /
    • pp.399-406
    • /
    • 2000
  • The effect of inlay surface treatment on bonding was investigated when resin inlay was bonded to resin-modified glass-ionomer base with resin cement. For the preparation of glass-ionomer base, resin-modified glass-ionomer cement (Fuji II LC, GC Co., Japan) was filled in class I cavities of 7mm in diameter and 2mm in depth made in plastic molds. Eighty eight resin inlay specimens were made with Charisma$^{(R)}$ (Kulzer, Germany) and then randomly assigned to the four different surface treatment conditions: Group I, $50{\mu}m$ aluminium oxide sandblasting and silane treatment ; Group II, silane treatment alone ; Group III, sandblasting alone, and Group IV (control), no surface treatment. After a dentin bonding agent with primer (One-Step$^{TM}$, Bisco Inc., IL., U.S.A.) was applied to bonding surface of resin inlay and base, resin inlay were cemented to glass-ionomer base with a resin cement (Choice$^{TM}$, Bisco Inc., IL., U.S.A.). Shear bond strengths of each specimens were measured using Instron universal testing machine (4202 Instron, lnstron Co., U.S.A.) and fractured surfaces were examined under the stereoscope. Statistical analysis was done with one-way ANOVA and Dunkan's multiple range test. The results were as follows: 1. Sandblasting and silane treatment provided the greatest bond strength(10.56${\pm}$1.95 MPa), and showed a significantly greater bond strength than sandblasting alone or no treatment (p<0.05). 2. Silane treatment provided a significantly greater bond strength(9.77${\pm}$2.04 MPa) than sandblasting alone or no treatment (p<0.05). However, there was no significant difference in bond strength between sandblasting treatment and silane one (p>0.05). 3. Sandblasting alone provided no significant difference in bond strength from no treatment (p>0.05). 4. Stereoscopic examination of fractured surface showed that sandblasting and silane treatment or silane treatment alone had more cohesive failure mode than adhesive failure mode. 5. In relationship between shear bond strength and failure mode, cohesive failure occurred more frequently as bond strength increased.

  • PDF