• 제목/요약/키워드: stepped building

검색결과 18건 처리시간 0.026초

Seismic evaluation of RC stepped building frames using improved pushover analysis

  • Sarkar, Pradip;Prasad, A. Meher;Menon, Devdas
    • Earthquakes and Structures
    • /
    • 제10권4호
    • /
    • pp.913-938
    • /
    • 2016
  • 'Stepped building' frames, with vertical geometric irregularity, are now increasingly encountered in modern urban constructions. This paper proposes a new approach to determine the lateral load pattern, considering the contributions from the higher modes, suitable for pushover analysis of stepped buildings. Also, a modification to the displacement coefficient method of ASCE/SEI 41-13 is proposed, based on nonlinear time history analysis of 78 stepped frames. When the newly proposed load pattern is combined with the modified displacement coefficient method, the target displacement for the stepped building frame is found to match consistently the displacement demand given by the time history analysis.

Inelastic lateral-torsional buckling strengths of stepped I-beams subjected to general loading condition

  • Park, Jong Sup;Park, Yi Seul
    • Structural Engineering and Mechanics
    • /
    • 제48권2호
    • /
    • pp.275-289
    • /
    • 2013
  • The cross sections of multi-span beams are sometimes suddenly increased at the interior support of continuous beams to resist high negative moment. An earlier study on elastic lateral torsional buckling of stepped beams was conducted to propose new design equations. This research aims to continue the earlier study by considering the effect of inelastic buckling of stepped beams subjected to pure bending and general loading condition. A three-dimensional finite element-program ABAQUS and a statistical program MINITAB were used in the development of new design equations. The inelastic lateral torsional buckling strengths of 36 and 27 models for singly and doubly stepped beams, respectively, were investigated. The general loading condition consists of 15 loading cases based on the number of inflection point within the unbraced length of the stepped beams. The combined effects of residual stresses and geometrical imperfection were also considered to evaluate the inelastic buckling strengths. The proposed equations in this study will definitely improve current design methods for the inelastic lateral-torsional buckling of stepped beams and will increase efficiency in building and bridge design.

Stability and minimum bracing for stepped columns with semirigid connections: Classical elastic approach

  • Aristizabal-Ochoa, J. Dario
    • Structural Engineering and Mechanics
    • /
    • 제5권4호
    • /
    • pp.415-431
    • /
    • 1997
  • Stability equations that evaluate the elastic critical axial load of stepped columns under extreme and intermediate concentrated axial loads in any type of construction with sidesway totally inhibited, partially inhibited and uninhibited are derived in a classical manner. These equations can be utilized in the stability analysis of framed structures (totally braced, partially braced, and unbraced) with stepped columns with rigid, semirigid, and simple connetions. The proposed column classification and the corresponding stability equations overcome the limitations of current methods which are based on a classification of braced and unbraced columns. The proposed stability equations include the effects of: 1) semirigid connections; 2) step variation in the column cross section at the point of application of the intermediate axial load; and 3) lateral and rotational restraints at the intermediate connection and at the column ends. The proposed method consists in determining the eigenvalue of a $2{\times}2$ matrix for a braced column at the two ends and of a $3{\times}3$ matrix for a partially braced or unbraced column. The stability analysis can be carried out directly with the help of a pocket calculator. The proposed method is general and can be extended to multi-stepped columns. Various examples are include to demonstrate the effectiveness of the proposed method and to verify that the calculated results are exact. Definite minimum bracing criteria for single stepped columns is also presented.

연속경간 하중을 받는 I형 스텝보의 비탄성 횡-비틀림 좌굴강도산정을 위한 모멘트 구배계수 연구 (A Study on Moment Gradient Factor for Inelastic Lateral-Torsional Buckling of Stepped I-Beam Subjected to Uniformly Distributed Load and End Moment)

  • 손지민;박종섭
    • 한국방재학회 논문집
    • /
    • 제9권4호
    • /
    • pp.1-9
    • /
    • 2009
  • 본 논문은 등분포하중과 양끝단에 모멘트가 작용하는 계단식 변단면보(스텝보)의 비선형 횡-비틀림 좌굴에 대해 연구이다. 3차원 유한요소해석 프로그램인 ABAQUS(2007)와 회귀분석 프로그램 MINITAB(2006)이 단순보 경계조건을 가지고 있는 일단 또는 양단 변단면보의 설계 좌굴강도 산정식 개발에 적용되었다. 해석모델의 비지지길이 내 중앙부분의 플랜지는 폭 30.48cm, 두께 2.54cm로 고정되었으며, 양단 또는 일단 플랜지의 크기는 해석매개변수로 고려되었다. 양단 스텝보는 플랜지 해석매개변수를 고려하여 27개, 일단 스텝보는 36개의 해석모델이 하나의 하중조건에 적용되었다. 본 연구는 잔류응력과 초기변형을 고려하여 비탄성 구간 내 3가지 비지지길이와 5가지 하중조건이 고려된 총 945개의 해석모델을 고려하였다. 잔류응력의 분포는 Pi와 Trahair(1995)가 적용한 분포도를 사용하였으며, 초기변형은 현대제철의 제작기준인 형강길이의 0.1%조건을 적용하였다. 본 논문에 제안된 식과 유한요소해석결과를 비교분석한 결과 양단 스텝보에서는 최대 13%, 일단 스텝보에서는 최대 10%의 차이를 보이고 있다. 본 연구를 통해 개발된 식은 경제적이고 합리적인 설계에 적극활용 가능하며, 변단면 부재의 비탄성 좌굴강도 연구에 크게 기여할 것이다.

균일모멘트를 받는 계단식 I형보의 비탄성 횡-비틀림 좌굴에 관한 연구 (A Study on Inelastic Lateral-Torsional Buckling of Stepped I-Beams Subjected to Pure Bending)

  • 김종민;김승준;박종섭;강영종
    • 한국강구조학회 논문집
    • /
    • 제20권2호
    • /
    • pp.237-246
    • /
    • 2008
  • 연속경간을 가지는 I형강 교량은 내부 지점근처에서 상대적으로 큰 부모멘트가 발생하게 되는데, 이에 경제적인 단면 활용을 위하여 내부 지점부위의 상부 및 하부플랜지에 플레이트를 보강한 변단면을 사용하고 있다. 본 연구에서는 기존 탄성 횡-비틀림 좌굴식에 관한 연구를 토대로 하여 비탄성 구간에 있는 계단식 I형보의 횡-비틀림 좌굴강도를 범용구조해석프로그램 ABAQUS(2006)를 이용하여 산정하고, 간편한 설계식을 제안하고 있다. 유한요소해석에는 4절점 쉘요소인 S4R이 사용되었고, 국내외에서 많이 사용되는 I형강 단면(${W36{\times}160}$)을 대상으로 하였다. 양단 및 한쪽 끝단에 계단식 단면을 가지는 보에 대해서 고려하였으며, 플랜지 길이방향 비, 너비방향 비, 두께의 비로 계단식 I형보를 나타내었다. 해석에 사용된 매개변수는 각각 27가지 및 36가지 조합이고, 하중조건으로 보의 순수굽힘이 발생하는 균일모멘트를 적용시켰으며, 비탄성 구간범위 내에 있는 비지지 길이에 대하여 구조해석을 수행하였다. 비탄성 횡-비틀림 거동을 보기 위하여 잔류응력 및 초기결함을 고려한 비선형해석을 실시하였는데, Pi(1995)등이 고려한 잔류응력의 형상과 국내 I형강 표준 치수 허용치에 근거하여 부재 길이의 0.1%를 초기제작오차로 고려하였다. 본 연구 결과는 다양한 형식의 I형보가 사용되는 빌딩 및 교량의 경제적이고 합리적인 설계의 근간을 제공해 줄 것이며, 향후 다양한 하중 조건을 가지는 양단 또는 일단 계단식 단면 변화보의 비탄성 횡-비틀림 좌굴강도를 계산할 수 있는 설계식 개발에 적극 활용 될 수 있을 것이다.

Wind tunnel tests and CFD simulations for snow redistribution on 3D stepped flat roofs

  • Yu, Zhixiang;Zhu, Fu;Cao, Ruizhou;Chen, Xiaoxiao;Zhao, Lei;Zhao, Shichun
    • Wind and Structures
    • /
    • 제28권1호
    • /
    • pp.31-47
    • /
    • 2019
  • The accurate prediction of snow distributions under the wind action on roofs plays an important role in designing structures in civil engineering in regions with heavy snowfall. Affected by some factors such as building shapes, sizes and layouts, the snow drifting on roofs shows more three-dimensional characteristics. Thus, the research on three-dimensional snow distribution is needed. Firstly, four groups of stepped flat roofs are designed, of which the width-height ratio is 3, 4, 5 and 6. Silica sand with average radius of 0.1 mm is used to model the snow particles and then the wind tunnel test of snow drifting on stepped flat roofs is carried out. 3D scanning is used to obtain the snow distribution after the test is finished and the mean mass transport rate is calculated. Next, the wind velocity and duration is determined for numerical simulations based on similarity criteria. The adaptive-mesh method based on radial basis function (RBF) interpolation is used to simulate the dynamic change of snow phase boundary on lower roofs and then a time-marching analysis of steady snow drifting is conducted. The overall trend of numerical results are generally consistent with the wind tunnel tests and field measurements, which validate the accuracy of the numerical simulation. The combination between the wind tunnel test and CFD simulation for three-dimensional typical roofs can provide certain reference to the prediction of the distribution of snow loads on typical roofs.

선형 모멘트 하중을 받는 계단식 단면변화 I형보의 비탄성 횡-비틀림 좌굴강도산정을 위한 모멘트 구배계수 연구 (A Study on Moment Gradient Factor for Inelastic Lateral-Torsional Buckling Strength of Stepped I-Beam Subjected to Linear Moment Gradient)

  • 박종섭;손지민
    • 한국방재학회 논문집
    • /
    • 제8권6호
    • /
    • pp.53-60
    • /
    • 2008
  • 일반적으로 연속경간을 가지는 강합성 I-형강 교량에 있어서 내부 지점 부근에서 상대적으로 큰 부모멘트가 발생하므로, 이에 경제적인 단면 활용을 위하여 변단면을 적용하여 휨강도를 증가시킨다. 본 연구에서는 기존 횡-비틀림 좌굴식에 관한 연구를 토대로 하여 비탄성 구간에 있는 계단식 I형보의 횡-비틀림 좌굴강도를 유한요소해석프로그램 ABAQUS(2007)를 이용하여 산정하고, 간편한 설계식을 제안하고 있다. 양단 및 일단 계단식 단면변화를 가지는 보에 대해서 고려하였으며, 플랜지 길이방향 비, 너비방향 비, 두께의 비로 계단식 I형보를 나타내었다. 해석에 사용된 단면매개변수는 각각 27가지 및 36가지 조합이며, 비탄성 횡-비틀림 거동을 고려하기위하여 잔류응력 및 초기결함을 고려한 비선형해석을 실시하였는데, Pi와 Trahair(1995)가 고려한 잔류응력의 형상과 국내 I형강 표준 치수 허용치에 근거하여 부재 길이의 0.1%를 초기제작오차로 고려하였다. 해석모델의 양쪽 끝단에는 모멘트하중을 재하하였다. 개발 제한된 식은 선형 모멘트 하중이 작용할 때 적용가능한 식으로 경제적이고 합리적인 설계에 적극 활용될 수 있을 것이며, 다양한 하중을 받는 계단식 단면 변화보의 비탄성 좌굴강도 연구에 활용될 수 있을 것이다.

서울 정릉(貞陵) 재실(齋室)에 대한 소고 (Study on the Memorial Structure(齋室) in Front of Jeongreung Royal Tomb(貞陵) in Seoul)

  • 최득준
    • 건축역사연구
    • /
    • 제22권2호
    • /
    • pp.21-30
    • /
    • 2013
  • This study is related to excavation from ruins the memorial structure within the Jeongreung royal tomb. There are experimental assertion on the basis of results of the excavation, historical records. The location of the memorial structure is identified in picture of Sunwonbogam(선원보감), records of Chunkwantongho(春官通考). The memorial structure have 6 rooms where lay in 250 steps(步) from the south of Hongjeonmun gate, lotus pond lay in southeast of the structure recorded on Chunkwantongho that's guide book to manners. It's matched in the location as result of excavation. The building site consists of main house(윗채), outhouse(아래채) that's stationed in stepped. It seems that main house as the memorial structure have 6 rooms. It's used as outhouse for facilities attached to the main. It's characterized the memorial structure within the Jeongreung royal tomb that's stationed main house, outhouse in stepped it using natural ground. It's estimated that it's tried to conservation for building site, fence etc. in next several time. With regard to constructing time of the structure, traces involved to first construction is simple: 2 chimneys in flower bed, fence, a part of stone elevation, drains by using rectangular stone. It shows that the building site had been reconstructed or renovated during Gho-jong King 37s year of the Choson dynasty(A.D.1900). It seems that the memorial structure during approximately 300 years in existence from Hyeon-jong King 10s year of the Choson dynasty(A.D.1669) to the late 1960s.

Variation in wind load and flow of a low-rise building during progressive damage scenario

  • Elshaer, Ahmed;Bitsuamlak, Girma;Abdallah, Hadil
    • Wind and Structures
    • /
    • 제28권6호
    • /
    • pp.389-404
    • /
    • 2019
  • In coastal regions, it is common to witness significant damages on low-rise buildings caused by hurricanes and other extreme wind events. These damages start at high pressure zones or weak building components, and then cascade to other building parts. The state-of-the-art in experimental and numerical aerodynamic load evaluation is to assume buildings with intact envelopes where wind acts only on the external walls and correct for internal pressure through separate aerodynamic studies. This approach fails to explain the effect of openings on (i) the external pressure, (ii) internal partition walls; and (iii) the load sharing between internal and external walls. During extreme events, non-structural components (e.g., windows, doors or rooftiles) could fail allowing the wind flow to enter the building, which can subject the internal walls to lateral loads that potentially can exceed their load capacities. Internal walls are typically designed for lower capacities compared to external walls. In the present work, an anticipated damage development scenario is modelled for a four-story building with a stepped gable roof. LES is used to examine the change in the internal and external wind flows for different level of assumed damages (starting from an intact building up to a case with failure in most windows and doors are observed). This study demonstrates that damages in non-structural components can increase the wind risk on the structural elements due to changes in the loading patterns. It also highlights the load sharing mechanisms in low rise buildings.

Influence of geometric factors on pull-out resistance of gravity-type anchorage for suspension bridge

  • Hyunsung, Lim;Seunghwan, Seo;Junyoung, Ko;Moonkyung, Chung
    • Geomechanics and Engineering
    • /
    • 제31권6호
    • /
    • pp.573-582
    • /
    • 2022
  • The geometry of the gravity-type anchorage changes depends on various factors such as the installation location, ground type, and relationship with the upper structure. In particular, the anchorage geometry embedded in the ground is an important design factor because it affects the pull-out resistance of the anchorage. This study examined the effect of four parameters, related to anchorage geometry and embedded ground conditions, on the pull-out resistance in the gravity-type anchorage through two-dimensional finite element analysis, and presented a guide for major design variables. The four parameters include the 1) flight length of the stepped anchorage (m), 2) flight height of the stepped anchorage (n), 3) the anchorage heel height (b), and 4) the thickness of the soil (e). It was found that as the values of m increased and the values of n decreased, the pull-out resistance of the gravity-type anchorage increased. This trend is related to the size of the contact surface between the anchorage and the rock, and it was confirmed that the value of n, which has the largest change rate of the contact surface between the anchorage and the rock, has the greatest effect on the pull-out resistance of the anchorage. Additionally, the most effective design was achieved when the ratio of the step to the bottom of the anchorage (m) was greater than 0.7, and m was found to be an important factor in the pull-out resistance behavior of the anchorage.