• Title/Summary/Keyword: step-up ratio

Search Result 273, Processing Time 0.03 seconds

Electrical Characteristics of the High Power Piezoelectric transformer Using PSN-PZT system ceramics (PSN-PZT계 세라믹스를 이용한 고출력 압전 트랜스포머의 전기적 특성)

  • 이용우;류주현;윤광희;정회승;서성재;김종선
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.4
    • /
    • pp.286-293
    • /
    • 2000
  • In this paper we investigated the structural dielectric and piezoelectric properties of 0.03Pb(Sb$\_$1/2//Nb$\_$1/2/)-0.97Pb(Zr$\_$0.495//Ti$\_$0.505/)O$_3$+0.5 wt% excess PbO + wt% MnO(X=0, 0.1, 0.3, 0.5, 0.7) ceramics to develop the high-power piezoelectric transformer. The piezoelectric transformers with dimension of 27.5$\times$27.5$\times$2.5[mm$^3$]were fabricated and their electrical properties were measured. Maxima of piezoelectric properties such as electro-mechanical coupling factor of 0.534 and mechanical quality factor of 1487 were obtained for the PSN-PZT with 0.3wt% MnO. voltage step-up ratios of piezoelectric transformers at 500[Ω]and no load were 0.78, 12.82, respectively. The maximum efficiency of piezoelectric transformer was 98.6% at 800[Ω]. While the 14W fluorescent lamp were driven by the piezoelectric transformer for more than 20[min], increment of temperature in the piezoelectric transformer was 7[$\^{C}$].

  • PDF

Analysis and Implementation of a New Single Switch, High Voltage Gain DC-DC Converter with a Wide CCM Operation Range and Reduced Components Voltage Stress

  • Honarjoo, Babak;Madani, Seyed M.;Niroomand, Mehdi;Adib, Ehsan
    • Journal of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.11-22
    • /
    • 2018
  • This paper presents a single switch, high step-up, non-isolated dc-dc converter suitable for renewable energy applications. The proposed converter is composed of a coupled inductor, a passive clamp circuit, a switched capacitor and voltage lift circuits. The passive clamp recovers the leakage inductance energy of the coupled inductor and limits the voltage spike on the switch. The configuration of the passive clamp and switched capacitor circuit increases the voltage gain. A wide continuous conduction mode (CCM) operation range, a low turn ratio for the coupled inductor, low voltage stress on the switch, switch turn on under almost zero current switching (ZCS), low voltage stress on the diodes, leakage inductance energy recovery, high efficiency and a high voltage gain without a large duty cycle are the benefits of this converter. The steady state operation of the converter in the continuous conduction mode (CCM) and discontinuous conduction mode (DCM) is discussed and analyzed. A 200W prototype converter with a 28V input and a 380V output voltage is implemented and tested to verify the theoretical analysis.

Novel Non-Isolated DC-DC Converter Topology with High Step-Up Voltage Gain and Low Voltage Stress Characteristics Using Single Switch and Voltage Multipliers (단일 스위치와 전압 체배 회로를 이용하는 고변압비와 낮은 전압 스트레스를 가진 새로운 비절연형 DC-DC 컨버터 토폴로지)

  • Tran, Manh Tuan;Amin, Saghir;Choi, Woojin
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.83-85
    • /
    • 2019
  • The use of high voltage gain converters is essential for the distributed power generation systems with renewable energy sources such as the fuel cells and solar cells due to their low voltage characteristics. In this paper, a high voltage gain topology combining cascode Inverting Buck-Boost converter and voltage multiplier structure is introduced. In proposed converter, the input voltage is connected in series at the output, the portion of input power is directly delivered to the load which results in continuous input current. In addition, the voltage multiplier stage stacked in proper manner is not only enhance high step-up voltage gain ratio but also significantly reduce the voltage stress across all semiconductor devices and capacitors. As a result, the high current-low voltage switches can be employed for higher efficiency and lower cost. In order to show the feasibility of the proposed topology, the operation principle is presented and the steady-state characteristic is analyzed in detail. A 380W-40/380V prototype converter was built to validate the effectiveness of proposed converter.

  • PDF

Electrical properties of Step -Down Multilayer Piezoelectric transformer sintered at $900^{\circ}C$ Low Temperature ($900^{\circ}C$ 저온에서 소결된 깅압용 적층 압전 변압기의 전기적 특성)

  • Lee, Kba-Soo;Yoo, Ju-Hyun;Kim, In-Sung;Song, Jae-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.16-16
    • /
    • 2010
  • The multilayer piezoelectric transformer was manufactured using $Pb(Zn_{1/2}W_{1/2})O_3-Pb(Mn_{1/3}Nb_{2/3})O_3-Pb(Zr_{0.48}Ti_{0.52})O_3$ (abbreviated as PZW-PMN-PZT) ceramics and their electrical properties were investigated. The $k_{eff}$ of the input and the output calculated from the resonant and anti-resonant frequencies were 0.403 and 0.233, respectively. The voltage step-up ratio showed the maximum value in the vicinity of 81kHz. The multilayer piezoelectric transformer showed the temperature rise of about $36^{\circ}C$ at the output power of 12w.

  • PDF

Electrical Characteristic Change of Al/Pd Film by Hydrogen Gas (수소 기체에 의한 Al/Pd 박막의 전기 특성 변화)

  • Cho, Young-Sin
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.16 no.4
    • /
    • pp.386-390
    • /
    • 2005
  • Al film(135.5 nm thick) with Pd film(39.6 nm thick) on the top of it was made by thermal evaporation method. Electrical resistance change due to hydrogen absorption and desorption was measured by four point measurement method. The sample was activated by hydrogen absorption and desorption cycling at room temp. Hydrogen was introduced into the film by increasing hydrogen gas pressure step by step up to 640 torr at room temp. The resistance change ratio was decreased to 12 % with increasing hydrogen pressure in contrast to normal metal behavior. This strange tendency was not understood yet. Further study is needed to find out the mechanism of hydrogen absorption in Al in Al/Pd film.

Optimization of ground response analysis using wavelet-based transfer function technique

  • Moghaddam, Amir Bazrafshan;Bagheripour, Mohammad H.
    • Geomechanics and Engineering
    • /
    • v.7 no.2
    • /
    • pp.149-164
    • /
    • 2014
  • One of the most advanced classes of techniques for ground response analysis is based on the use of Transfer Functions. They represent the ratio of Fourier spectrum of amplitude motion at the free surface to the corresponding spectrum of the bedrock motion and they are applied in frequency domain usually by FFT method. However, Fourier spectrum only shows the dominant frequency in each time step and is unable to represent all frequency contents in every time step and this drawback leads to inaccurate results. In this research, this process is optimized by decomposing the input motion into different frequency sub-bands using Wavelet Multi-level Decomposition. Each component is then processed with transfer Function relating to the corresponding component frequency. Taking inverse FFT from all components, the ground motion can be recovered by summing up the results. The nonlinear behavior is approximated using an iterative procedure with nonlinear soil properties. The results of this procedure show better accuracy with respect to field observations than does the Conventional method. The proposed method can also be applied to other engineering disciplines with similar procedure.

Effects of Body Weight Control Program Contains Exercise and Auricular Acupuncture on Body Composition, Blood Composition and Physical Ability in Obese Children (운동과 이침요범을 병행한 체중조절 프로그램이 비만아동의 체성분, 혈액구성 및 체력에 미치는 영향)

  • Kwak, Min-A;Kim, Dae-Jun;Byun, Joon-Seok
    • Journal of Acupuncture Research
    • /
    • v.26 no.2
    • /
    • pp.171-179
    • /
    • 2009
  • Objectives: The purpose of this study was to investigate the changes of obesity, blood composition and physical ability in obese children on body weight control program. Methods : The body weight control program included exercise, nutrition education and auricular acupuncture was performed 4 times a week during 12 weeks. 32 obese children whose body fat ratio were over 30% participated in this study. Measuring materials were body composition(weight, muscle mass, fat mass, fat ratio, BMI), physical measurement(height, waist circumference, chest circumference, hip circumference), physical ability(grip strength, sit-ups, sitting trunk flexion, sit-down stand-up test, standing long jump, opened eyes foot balance, side step), blood composition(WBC, Hb, ESR, Total Cholesterol, TG, GOT, GPT, BUN, Creatinine, Glucose) and survey(changes of eating habits, changes of living habits, knowledge of obesity, self-confidence, self-esteem). Results : From the results, positive changes were made in BMI, height, waist circumferences, chest circumferences, hip circumferences, sit-ups, sitting trunk flexion, sit-down stand-up test, standing long jump, opened eyes foot balance, side step, Hb, ESR, GOT, GPT and changes of eating habits through the body weight control program. Conclusions : This results suggest that body weight control program including exercise, nutrition education and auricular acupuncture may be effective for helping obese children.

  • PDF

A Non-isolated DC-DC Converter with High Step-up Ratio and Wide ZVS Range (고승압비와 넓은 ZVS 영역을 갖는 비절연 DC-DC 컨버터)

  • Park, Sung-Sik;Choi, Se-Wan;Choi, Woo-Jin;Lee, Kyo-Beum
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.4
    • /
    • pp.315-322
    • /
    • 2009
  • In the conventional boost converter, the actual duty cycle is limited as the output voltage increases due to increased voltage and current stress of the switch and diode and voltage surge caused by diode reverse recovery. In this paper a new non-isolated boost converter suitable for high gain applications is proposed. The proposed converter has voltage gain of around 6 when the duty cycle is 0.5. Since ZVS is achieved under CCM, the proposed converter has wide ZVS range. Also, voltage ratings of switch and diode are the same as one third of output voltage, and ratings of input and output passive components are reduced due to the interleaving. In addition voltage surge caused by diode reverse recovery is negligible due to ZCS turn-off of diodes. Operating principle of the proposed converter is described and validated through theoretical analysis, simulation and experiment.

Correlation between Weight Bearing Ratio and Functional Level for Development of Pressure Sensor Biofeedback in Stroke Patient

  • Moon, Young;Kim, Mi-Sun;Choi, Jong-Duk
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.9 no.3
    • /
    • pp.315-324
    • /
    • 2014
  • PURPOSE: This study aimed to determine the correlation of weight bearing ability at the affected side with balance and gait abilities for the development of pressure biofeedback based equipment to stroke patients. METHODS: This study included 35 patients with stroke patient. The tests were conducted to determine the weight bearing ratio while pushing a step forward the affected side, static balance ability using the total length of COP(Center of pressure), sway velocity of COP, COP velocity at the X and Y axis. Functional reaching test (FRT), berg balance scale (BBS) were used to assess the dynamic balance ability and timed up and go test (TUG), 10m walk test (10mWT) were used assess the gait ability respectively. In order to determine the correlation between measured variables, bivariate correlation analysis was conducted. RESULTS: A significant correlation of the weight bearing ratio were shown with COP total length and velocity(r=-.34), Y-axis velocity(r=-.39), FRT(r=.42), BBS(r=.54), TUG (r=-.39), and 10m walking test (r=-.42). CONCLUSION: This study result showed that as patients with stroke had more weight bearing ratio at the affected side, not only their static and dynamic balance abilities increased more but also functional gait ability improved more. These results mean that, to improve stroke patients' static, dynamic balance ability and gait ability, weight bearing training with the affected side foot placed one step forward necessary for gaits are important.

Effect. of $TiO_2$ and PZT powder additions on the Ag/Pd Electrode for Step-down Multilayer Piezoelectric Transformer (적충 강압형 압전변압기 Ag/Pd 전극의 $TiO_2$ 와 PZT 분말의 첨가에 따른 효과연구)

  • Joo, Hyeon-Kyu;Kim, In-Sung;Vo, Vietthang;Jeong, Soon-Jong;Kim, Min-Soo;Song, Jae-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.334-334
    • /
    • 2010
  • In order to fabricate the multilayer piezoelectric transformer by tape casting method, we investigated the effect of $TiO_2$ and PZT powder additions on the Ag/Pd electrode. Meanwhile, effects of $TiO_2$ and PZT powder additives on the microstructure and electrical properties of Ag/Pd electrode were investigated in detail. In addition, the multilayer piezoelectric transformers were fabricated and the characteristics with various load resistance were measured at resonance frequency. The voltage step-up ratio was continuously change with increasing input voltage and load resistance, and then output voltage and powers were increased with increasing input voltage at matching impedance. The temperature rise of multilayer piezoelectric transformers were increased with increasing input voltage and load resistance. Meanwhile, multilayer piezoelectric transformers sintered at $1100^{\circ}C$ show the favorable characteristics with a power of 15 W at $100\;{\Omega}$.

  • PDF