• 제목/요약/키워드: step up

Search Result 2,383, Processing Time 0.026 seconds

Single Pulse-Width-Modulation Strategy for Dual-Active Bridge Converters

  • Byen, Byeng-Joo;Jeong, Byong-Hwan;Choe, Gyu-Ha
    • Journal of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.137-146
    • /
    • 2018
  • This paper describes a single pulse-width modulation control strategy using the Single Pulse-Width Modulation (SPWM) method with a soft-switching technique for a wide range of output voltages from a bidirectional Dual-Active Bridge (DAB) converter. This method selects two typical inductor current waveforms for soft-switching, and proposes a rule that makes it possible to achieve soft-switching without any compensation algorithm from the waveforms. In addition, both the step-up and step-down conditions are analyzed. This paper verifies that the leakage inductance is independent from the rule, which makes it easier to apply in DAB converters. An integrated algorithm, which includes step-up and step-down techniques, is proposed. The results of experiments conducted on a 50-kW prototype are presented. The system efficiency is experimentally verified to be from 85.6% to 97.5% over the entire range.

Low-Cost High-Efficiency Two-Stage Cascaded Converter of Step-Down Buck and Tapped-Inductor Boost for Photovoltaic Micro-Inverters (태양광 마이크로 인버터를 위한 탭인덕터 부스트 및 강압형 컨버터 캐스케이드 타입 저가형 고효율 전력변환기)

  • Jang, Jong-Ho;Shin, Jong-Hyun;Park, Joung-Hu
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.2
    • /
    • pp.157-163
    • /
    • 2014
  • This paper proposes a two-stage step-down buck and a tapped-inductor boost cascaded converter for high efficiency photovoltaic micro-inverter applications. The proposed inverter is a new structure to inject a rectified sinusoidal current into a low-frequency switching inverter for single-phase grid with unity power factor. To build a rectified-waveform of the output current. the converter employs both of a high efficiency step-up and a step-down converter in cascade. In step-down mode, tapped inductor(TI) boost converter stops and the buck converter operates alone. In boost mode, the TI converter operates with the halt of buck operation. The converter provides a rectified current to low frequency inverter, then the inverter converts the current into a unity power-factor sinusoidal waveform. By applying a TI, the converter can decrease the turn-on ratios of the main switch in TI boost converter even with an extreme step-up operation. The performance validation of the proposed design is confirmed by an experimental results of a 120W hardware prototype.

Development of a Critical Pathway for Patients with Uterine Artery Embolization (자궁동맥색전술 환자를 위한 표준진료지침 개발)

  • Chung, Kyung-Hee;Ko, Young-Sook;Lim, Jeong-Ah
    • Women's Health Nursing
    • /
    • v.12 no.4
    • /
    • pp.316-325
    • /
    • 2006
  • Purpose: The purpose of this study was to develop a Critical Pathway for Uterine Artery Embolization patients. Method: There were 6 steps that were taken. Step 1 was selecting a diagnosis, and Step 2 was organizing a development team consisting of 7 experts. Step 3 analyzed the medical records, and Step 4 drew up a preliminary Critical Pathway. Step 5 tested the clinical validity of the preliminary Critical Pathway, and Step 6 developed the final Critical Pathway. Result: The contents of the medical practices observed in the medical records were investigated in seven areas: monitoring/assessment, treatment, medication, diet, activity, consults, and education/discharge plan; and a total of 73 items was identified. The validity of the 73 items was examined by a group of specialists. 68 items were adopted, 4 items revised, 1 item removed, and 1 item was added. Using the results, a preliminary Critical Pathway was drawn up. According to the results from examining the clinical validity of the preliminary Critical Pathway with five patients for five weeks, 3 items which showed discrepancy were revised and another 3 items were added. Then, the final Critical Pathway was completed. Conclusion: This Critical Pathway needs to be clinically applied and continuously to measure its effects in terms of the length of stay, cost.effectiveness, and the patients' and staffs' satisfaction.

  • PDF

Setting Up/Down Step-Size in Open Loop Power Control for WiBro Reverse Link (와이브로 상향링크에서 개방형 전력제어를 위한 상/하향 전력제어 계단값 설정 방법)

  • Guk, Hyun;Kim, Jung-Bin;Kim, Dong-Woo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.7A
    • /
    • pp.686-693
    • /
    • 2007
  • In this paper, we describe how to set up/down step-size in open loop power control for WiBro reverse link. Since open loop power control does not use feedback information, it is difficult to efficiently use wireless resource with accurate power control. We also provides a method of estimating levels of noise and interference. With numerical investigation, asymmetric up/down power-control step-size is shown to be promising to achieve high sector throughput as well as low error rate.

A Study on the Position and Speed Control of PM Step Motor Using Micro-Step Control Drive (미세스텝 제어 방식에 의한 PM 스텝 모터의 위치 및 속도 제어에 관한 연구)

  • 김동현;한권상
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.6
    • /
    • pp.871-878
    • /
    • 1990
  • The control method which electrically subdivides 1 step(1.8\ulcornerstep) of a PM step motor into 64 micro-step (0.028\ulcornerstep) is realized using micro-step algorithm on the basis of the look up table method and the position and velocity control using Z-80 microprocessor is also realized. With micro-stepping. The resolution of the system is improved, also by micro-step control of driving-current of the step motro, which is followed by the increase of micro-step subdivision-coefficient, the precise position and velocity control of step-motor can be realized and the stabilization of the system is improved.

  • PDF

Design of a step-up DC-DC Converter using a 0.18 um CMOS Process (0.18 um CMOS 공정을 이용한 승압형 DC-DC 컨버터 설계)

  • Lee, Ja-kyeong;Song, Han-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.6
    • /
    • pp.715-720
    • /
    • 2016
  • This paper proposes a PWM (Pulse Width Modulation) voltage mode DC-DC step-up converter for portable devices. The converter, which is operated with a 1 MHz switching frequency, is capable of reducing the mounting area of passive devices, such as inductor and capacitor, and is suitable for compact mobile products. This step-up converter consists of a power stage and a control block. The circuit elements of the power stage are an inductor, output capacitor, MOS transistors Meanwhile, control block consist of OPAMP (operational amplifier), BGR (band gap reference), soft-start, hysteresis comparator, and non-overlap driver and some protection circuits (OVP, TSD, UVLO). The hysteresis comparator and non-overlapping drivers reduce the output ripple and the effects of noise to improve safety. The proposed step-up converter was designed and verified in Magnachip/Hynix 0.18um 1-poly, 6-metal CMOS process technology. The output voltage was 5 V with a 3.3 V input voltage, output current of 100 mA, output ripple less than 1% of the output voltage, and a switching frequency of 1 MHz. These designed DC-DC step-up converters could be applied to the Personal Digital Assistants(PDA), cellular Phones, Laptop Computer, etc.

An Efficient and High-gain Inverter Based on The 3S Inverter Employs Model Predictive Control for PV Applications

  • Abdel-Rahim, Omar;Funato, Hirohito;Junnosuke, Haruna
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.4
    • /
    • pp.1484-1494
    • /
    • 2017
  • We present a two-stage inverter with high step-up conversion ratio engaging modified finite-set Model Predictive Control (MPC) for utility-integrated photovoltaic (PV) applications. The anticipated arrangement is fit for low power PV uses, the calculated efficiency at 150 W input power and 19 times boosting ratio was around 94%. The suggested high-gain dc-dc converter based on Cockcroft-Walton multiplier constitutes the first-stage of the offered structure, due to its high step-up ability. It can boost the input voltage up to 20 times. The 3S current-source inverter constitutes the second-stage. The 3S current-source inverter hires three semiconductor switches, in which one is functioning at high-frequency and the others are operating at fundamental-frequency. The high-switching pulses are varied in the procedure of unidirectional sine-wave to engender a current coordinated with the utility-voltage. The unidirectional current is shaped into alternating current by the synchronized push-pull configuration. The MPC process are intended to control the scheme and achieve the subsequent tasks, take out the Maximum Power (MP) from the PV, step-up the PV voltage, and introduces low current with low Total Harmonic Distortion (THD) and with unity power factor with the grid voltage.

Measurement Range Extension of AC High Voltage using two 200 kV Capacitive Dividers (200 kV 용량형 분압기 2대를 이용한 교류 고전압 측정범위 확장)

  • Jung, Jae-Kap;Lee, Sang-Hwa;Kang, Jeon-Hong;Kim, Myung-Soo;Kim, Yoon-Hyoung;Han, Sang-Gil;Jeong, Jin-Hye;Han, Sang-Ok;Joung, Jong-Man
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.1
    • /
    • pp.1-5
    • /
    • 2008
  • The output voltage value of AC high voltage source has been usually obtained by multiplying low voltage value measured at both terminals of low voltage resistor by the dividing ratio of the high voltage capacitive divider. From the dividing ratio determined of each 200 kV capacitive divider, we have developed step-up method for measuring the output voltage up to 400 kV using two same type of 200 kV capacitive dividers connected in series. The theoretical dividing ratio of 400 kV capacitive dividers connected in series coincides with that of manufacturer's certification within measurement uncertainty. Thus, this developed step-up method makes it possible to extend the range of output voltage from 200 kV to 400 kV. Furthermore, The dividing ratio of divider under test obtained using this step-up method is consistent with that obtained using one 200 kV high voltage divider within corresponding uncertainties.

NOVEL LIGHTING SYSTEMS STIMULATING GONADAL DEVELOPMENT AND EXPEDITING SEXUAL MATURITY OF MALE AND FEMALE CHICKENS

  • Umeda, I.;Hayakawa, H.;Kamiya, S.;Tanabe, Y.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.6 no.1
    • /
    • pp.127-132
    • /
    • 1993
  • Ten-week-old White Leghorn immature males and females were exposed to four lighting regimens: a constant light (12L : 12D); repeated up and slow down (13 min. up and 1 min. down per day for 13 consecutive days, and repeated on two-week cycle) lighting; repeated slow up and down (1 min. up per day for 13 consecutive days and 13 min. down, and repeated on two-week cycle) lighting; and step-up (14 min. up every second week) lighting. At 15 weeks of age, significantly larger testis and comb weights and significantly higher concentrations of plasma LH and testosterone were observed in the cockerels under the repeated slow up and down lighting regimen than those under the other lighting regimens. At 20 weeks of age, significantly larger oviduct weights and significantly higher concentrations of plasma estradiol were observed in the pullets under the repeated up and slow down, and the step-up lighting regimens than those under the other lighting regimens.

Fuel Cell Inverter Operation for Distributed Generation of simulation (연료전지의 인버터 운전 시뮬레이션)

  • Jeong, Dong-Hyo
    • Proceedings of the KIEE Conference
    • /
    • 2007.11c
    • /
    • pp.170-174
    • /
    • 2007
  • Recently, a fuel cell is remarkable for new generation system. The fuel cell generation system converts the chemical energy of a fuel directly into electrical energy. The fuel cell generation is characterized by low voltage and high current. For connecting to utility, it needs both a step up converter and an inverter. The step up converter makes DC link and the inverter changes DC to AC. In this paper full bridge converter and the single phase inverter are designed and installed for fuel cell. Simulation and experiment verify that fuel cell generation system could be applied for the distributed generation.

  • PDF