• Title/Summary/Keyword: step count

Search Result 137, Processing Time 0.023 seconds

Step Count Detection Algorithm using Acceleration Sensor (가속도 센서를 이용한 걸음수 검출 알고리즘)

  • Han, Y.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.9 no.3
    • /
    • pp.245-250
    • /
    • 2015
  • Portable devices, such as smart phones and personal digital assistants (PDAs) play an important role in our everyday life. In this paper, we propose a step count algorithm based on SVM(signal vector magnitude) and a adaptive threshold processing to monitor the physical activity. The algorithm measures a user's step counts using the smart phone's inbuilt accelerometer and g sensor. Experiment results showed the proposed algorithm has good performance in accuracy and adaptability than the app on your smart phone.

  • PDF

Accuracy Improvement Methode of Step Count Detection Using Variable Amplitude Threshold (가변 진폭 임계값을 이용한 걸음수 검출 정확도 향상 기법)

  • Ryu, Uk Jae;Kim, En Tae;An, Kyung Ho;Chang, Yun Seok
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.2 no.6
    • /
    • pp.257-264
    • /
    • 2013
  • In this study, we have designed the variable amplitude threshold algorithm that can enhance the accuracy of step count using variable amplitude. This algorithm converts the x, y, z sensor values into a single energy value($E_t$) by using SVM(Signal Vector Magnitude) algorithm and can pick step count out over 99% of accuracy through the peak data detection algorithm and fixed peak threshold. To prove the results, We made the noise filtering with the fixed amplitude threshold from the amplitude of energy value that found out the detection error was increasing, and it's the key idea of the variable amplitude threshold that can be adapted on the continuous data evaluation. The experiment results shows that the variable amplitude threshold algorithm can improve the average step count accuracy up to 98.9% at 10 Hz sampling rate and 99.6% at 20Hz sampling rate.

Impact of Musculoskeletal Pain on Pedestrian Crossing among the Aged (노인의 근육뼈대계 통증이 횡단보도 보행에 미치는 영향)

  • Um, Ki-Mai;Wang, Joong-San
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.12
    • /
    • pp.370-377
    • /
    • 2015
  • This study attempted to examine the impact of musculoskeletal pain on pedestrian crossing using a sample that consisted of 282 aged people. The research method involved an examination of the musculoskeletal pain of the elderly using a musculoskeletal questionnaire. The subjects were also told to walk across four- and six-lane pedestrian crossings while their gait velocity, step count, and step time were measured. The research results for pain by body regions indicated that waist pain had the highest complaint rate(33.3%). When there was musculoskeletal pain in the waist and leg/foot, gait velocity also decreased and step count and step time increased. However, usage of a cane turned out to have a positive impact on pedestrian crossing. Nevertheless, no significant relationship between waist and leg/foot pain and pedestrian crossing characteristics was found. We expect there will be continuous further studies on the subject of diverse physical problems of the aged and pedestrian crossing.

Design of Zigbee based Portable ECG monitoring system (지그비 기반의 휴대형 심전도 모니터링 시스템 설계)

  • Hong, Joo-Hyun;Kim, Nam-Jin;Cha, Eun-Jong;Lee, Tae-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2006.04a
    • /
    • pp.51-53
    • /
    • 2006
  • This paper proposes a portable ECG monitoring system, which integrates uptodate PDA and RF communication technology. The aim of the study is to acquire the subject's biomedical signal without any constraint. It has two types of transmission mode, which are total signal transmission mode and HR(heart rate)/SC(step count) transmission mode. In audition, wireless communication technology uses Zigbee Wireless PAN and can work in low-power mode, which is one of the advantages of ZiBbee communication technology. The developed system is composed of a transmitter and a receiver. The transmitter has three-axial acceleration sensor. ECG amplifier and Zigbee communication controller. In total signal transmission mode, it can send data 50 packets per second whose transmission speed corresponds to 300 ECG samples and 60 acceleration samples. In HR/SG transmission mode, it can calculate heart rate from EEG data with 216 samples per second and step count from acceleration data and send a packet every cardiac cycle. The receiver forwards the received data to PDA, where the data can be stored and displayed. Therefore, the developed device enables to continuous monitoring for Activities of Daily Living(ADL). Also, this method will reduce medical costs in the aged society.

  • PDF

A Fast Motion Estimation Algorithm with Motion Analysis (움직임 해석을 통한 고속 움직임 예측 알고리즘)

  • Jun, Young-Hyun;Yun, Jong-Ho;Cho, Hwa-Hyun;Choi, Myung-Ryul
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.339-342
    • /
    • 2005
  • We present an efficient block-based motion estimation algorithm with motion analysis. The motion analysis determines a size of search pattern and a maximum repeated count of search pattern. In case of large movement in large image, we reduce search points and the local minimum which caused by low performance. The proposed algorithm employs with searching step of 2. The first step determines an initial search point with neighbor block vector and a size of initial search pattern. The second step determines a size of search pattern and a maximum repeated count with motion analysis. We improve motion prediction accuracy while reducing required computational complexity compared to other fast block-based motion estimation algorithms.

  • PDF

Estimation of Substring Selectivity in Biological Sequence Database (생물학 서열 데이타베이스에서 부분 문자열의 선적도 추정)

  • 배진욱;이석호
    • Journal of KIISE:Databases
    • /
    • v.30 no.2
    • /
    • pp.168-175
    • /
    • 2003
  • Until now, substring selectivities have been estimated by two steps. First step is to build up a count-suffix tree, which has statistical information about substrings, and second step is to estimate substring selectivity using it. However, it's actually impossible to build up a count-suffix tree from biological sequences because their lengths are too long. So, this paper proposes a novel data structure, count q-gram tree, consisting of fixed length substrings. The Count q-gram tree retains the exact counts of all substrings whose lengths are equal to or less than q and this tree is generated in 0(N) time and in site not subject to total length of all sequences, N. This paper also presents an estimation technique, k-MO. k-MO can choose overlapping length of splitted substrings from a query string, and this choice will affect accuracy of selectivity and query processing time. Experiments show k-MO can estimate very accurately.

Real-Time Step Count Detection Algorithm Using a Tri-Axial Accelerometer (3축 가속도 센서를 이용한 실시간 걸음 수 검출 알고리즘)

  • Kim, Yun-Kyung;Kim, Sung-Mok;Lho, Hyung-Suk;Cho, We-Duke
    • Journal of Internet Computing and Services
    • /
    • v.12 no.3
    • /
    • pp.17-26
    • /
    • 2011
  • We have developed a wearable device that can convert sensor data into real-time step counts. Sensor data on gait were acquired using a triaxial accelerometer. A test was performed according to a test protocol for different walking speeds, e.g., slow walking, walking, fast walking, slow running, running, and fast running. Each test was carried out for 36 min on a treadmill with the participant wearing an Actical device, and the device developed in this study. The signal vector magnitude (SVM) was used to process the X, Y, and Z values output by the triaxial accelerometer into one representative value. In addition, for accurate step-count detection, we used three algorithms: an heuristic algorithm (HA), the adaptive threshold algorithm (ATA), and the adaptive locking period algorithm (ALPA). The recognition rate of our algorithm was 97.34% better than that of the Actical device(91.74%) by 5.6%.

A Study on a Algorithm of Gait Analysis and Step Count with Pressure Sensors (보행수 측정 및 보행패턴 분류 알고리즘)

  • Do, Ju-pyo;Choi, Dae-yeong;Kim, Dong-jun;Kim, Kyung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.12
    • /
    • pp.1810-1814
    • /
    • 2017
  • This paper develops an approach to the algorithm of Gait pattern Analysis and step measurement with Multi-Pressure Sensors. The process of gait consists of 8 steps including stance and swing phase. As 3 parts of foot is supporting most of human weight, multiple pressure sensors are attached on the parts of foot: forefoot, big toe, heel. As 3 parts of foot is supporting most of human weight, multiple pressure sensors are attached on the parts of foot: forefoot, big toe, heel. normal gait proceed from heel, forefoot and big toe over time. While normal gait proceeds, values of heel, forefoot and big toe can be changed over time. So Each values of pressure sensors over time could discriminate whether it is normal or abnormal gait. Measuring Device consists of non-inverting amplifiers and low pass filter. Through timetable of values, normal gait pattern can be analyzed, because of supported weight of foot. Also, the peak value of pressure can judge whether it is walking or running. While people are running, insole of shoes is floating in the air on moment. Using this algorithm, gait analysis and step count can be measured.

A study on MPEG-7 descriptor combining method using borda count method (Borda count 방법을 이용한 다중 MPEG-7 서술자 조합에 관한 연구)

  • Eom, Min-Young;Choe, Yoon-Sik
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.43 no.1 s.307
    • /
    • pp.39-44
    • /
    • 2006
  • In this paper, search result list synthesis method is proposed using borda count method for still image retrieval based on MPEG-7 descriptors. MPEG-7 standardizes descriptors that extract feature information from media data. In many cases, using a single descriptor lacks of correctness, it is suggested to use multiple descriptors to enhance retrieval efficiency. In this paper, retrieval efficiency enhancement is achieved by combining multiple search results which are from each descriptor. In combining search result, newly calculated borda count method is proposed. Comparing current frequency compensated calculation, rank considered frequency compensation is used to score animage in database. This combining method is considered in Content based image retrieval system with relevance feedback algorithm which uses high level information from system user. In each relevance iteration step, adoptive borda count method is used to calculate score of images.

A Study on the Productivity Increment through Construction of Lean Production System for Automobile Plant in China (중국 자동차 공장의 린 생산 체계 구축을 통한 생산성 향상에 관한 연구)

  • Jang, Jung-Hwan;Zhang, Jing-Lun;Yoo, Sung-Hee;Lee, Chang-Ho
    • Journal of the Korea Safety Management & Science
    • /
    • v.14 no.1
    • /
    • pp.117-122
    • /
    • 2012
  • This paper deals with the productivity increment through construction of lean production system for automobile factory in China. This lean production system has been progressed according to 5 steps. Step 1 is the work preparation. Step 2 is the process design. Step 3 is the establishment of method to count production quantity. Step 4 is the establishment of measuring method for input and output. Finally, step 5 is the construction of flexible production system able to adapt for environment change. This lean production system is expected to obtain the productivity increment by 50% for plastic plant and reduction by 50% in inventory quantity.