• Title/Summary/Keyword: stents

Search Result 274, Processing Time 0.022 seconds

Pharmaco-mechanical Thrombectomy and Stent Placement in Patients with May-Thurner Syndrome and Lower Extremity Deep Venous Thrombosis (May-Thurner 증후군과 동반된 하지 심부정맥혈전환자에서 혈전제거술과 스텐트삽입술)

  • Jeon, Yonh-Sun;Kim, Yong-Sam;Cho, Jung-Soo;Yoon, Yong-Han;Baek, Wan-Ki;Kim, Kwang-Ho;Kim, Joung-Taek
    • Journal of Chest Surgery
    • /
    • v.42 no.6
    • /
    • pp.757-762
    • /
    • 2009
  • Background: Compression of the left common iliac vein by the overriding common iliac artery is frequently combined with acute deep vein thrombosis in patients with May-Thurner Syndrome. We evaluate the results of treatment with thrombolysis and thrombectomy followed by stenting in 34 patients with May-Thurner Syndrome combined with lower extremity deep venous thrombosis. Material and Method: The authors retrospectively reviewed the records of 34 patients (mean age: $65{\pm}14$ year old) who had undergone stent insertion for acute deep vein thrombosis that was caused by May-Thurner syndrome. After thrombectomy and thrombolysis, insertion of a wall stent and balloon angioplasty were performed to relieve the compression of the left common iliac vein. Urokinase at a rate of 80,000 to 120,000 U/hour was infused into the thrombosed vein via a multi-side hole thrombolysis catheter. A retrieval inferior vena cava (IVC) filter was placed to protect against pulmonary embolism in 30 patients (88%). Oral anticoagulation with warfarin was maintained for 3 months, and follow-up Multi Detector Computerized Tomography (MDCT) angiography was done at the date of the patients' hospital discharge and at the 6 months follow-up. Result: The symptoms of deep venous thrombosis disappeared in two patients (4%), and there was clinical improvement within 48 hours in twenty eight patients (82%), but there was no improvement in four patients (8%). The MDCT angiography at discharge showed no thrombus in 9 patients (26%) and partial thrombus in 21 (62%), whereas the follow-up MDCT at $6.4{\pm}5.5$ months (32 patients) revealed no thrombus in 23 patients (72%), and partial thrombus in 9 patients (26%). Two patients (6%) had recurrence of DVT, so they underwent retreatment. Conclusion: Stent insertion with catheter-directed thrombolysis and thrombectomy is an effective treatment for May-Thurner syndrome combined with acute deep vein thrombosis in the lower extremity.

The Effect of Percutaneous Bilateral Metalic Stent for Hilar Cholangiocarcinoma (간문부 담관암 환자에서 경피경관 양측성 금속 배액관의 효과)

  • Kim, Kum-Rae;Kim, Joo-Hyung;Park, Won-Kyu;Jang, Jay-Chun;Cho, Jae-Ho;Kim, Tae-Nyen;Kim, Jun-Hwan;Jang, Byeng-Ik
    • Journal of Yeungnam Medical Science
    • /
    • v.22 no.2
    • /
    • pp.211-220
    • /
    • 2005
  • Background: The purpose of this study was to determine the effectiveness of a percutaneously placed self-expanding metallic stent for the relief of biliary obstruction in patients with hilar cholangiocarcinoma. Materials and Methods: From November 2001 to December 2004, 48 patients with hilar cholangiocarcinoma were prospectively studied. After percutaneous placement of bilateral selfexpanding, uncovered metallic stents, follow-up evaluation was carried out until July 2005. Results: There were 4 cases of Bismuth type II, 21 cases of Bismuth type IIIa, 8 cases of Bismuth type IIIb and 15 cases of Bismuth type IV. Stent placement was technically successful in all patients. All patients had satisfactory biliary drainage, resulting in one week drainage rate of 72.8% and final drainage rate of 91.1%. There were 12 cases (21.3%) of abdominal pain requiring analgesics and 1 case (7.1%) of cholangitis; both were successfully managed with conservative treatments. Late complications occurred in four patient (8.3%), including two patients with cholangitis, one patient with liver abscess, and one patient with biloma; all were appropriately managed by percutaneous drainage. The average length and median durations of stent patency and median survival time were 303 days (range, 60~815) and 338 days (range, 60~1175), respectively. Conclusion: Placement of a percutaneous metallic stent is an effective and safe method for palliation of patients with hilar cholangiocarcinoma.

  • PDF

Prognostic Analysis of Drug-Eluting Balloon Catheter and Drug-Eluting Stent for In-Stent Restenosis of Drug-Eluting Stent (스텐트 재협착 병변에서 약물코팅 풍선카테터과 약물용출 스텐트의 예후 분석)

  • Lee, Doo Hwan;Song, Jong Nam;Park, Sin eui;Choi, Nam Gil;Han, Jae Bok;Kim, In Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.381-389
    • /
    • 2019
  • Although the development of Drug-eluting stent (DES) improved the ISR significantly more than the Bare metal stent (BMS), the coronary stent restenosis (ISR) treatment still has a high recurrence rate. This study is compared the efficacy of DEB with that of DES implantation in patients with ISR. Among 4,316 patients who underwent coronary stent implantation at the Chonnam National University Hospital between November 2012 and December 2016, 187 patients developed ISR on follow-up coronary angiography ($66.3{\pm}11.0years$, 123 males) were enrolled and divided into two groups according to revascularization method as group I (DEB group; n=127) and group II (DES group; n=60). Primary end point was defined as major adverse cardiac events (MACEs), composite of cardiac death (CD), myocardial infaction (MI), target lesion revascularization (TLR) and stent thrombosis (ST) during two-year follow-up between the two groups. There were no differences in the baseline characteristics and angiographic findings except that prevalence of device length was shorter ($21.1{\pm}5.3$ vs. $25.3{\pm}9.6 mm$, p<0.002) in group I.Two-year MACE were not different in the two groups (8.7%vs.10.0%, p=0.789). The incidences of cardiac death (0%vs.0%, p=1.000), MI (1.6%vs.6.7%, p=0.085), TLR(8.7% vs. 10.0%, p=0.789) and ST (0% vs. 0%, p=1000). DEB demonstrated comparable risk reduction for MACEs compared with DES in patients with ISR during two-year follow-up. DEB might be good alternative for the treatment of ISR in patients with ISR.

Evaluating the usefulness of BinkieRTTM (oral positioning stent) for Head and Neck Radiotherapy (두경부암 환자 방사선 치료 시 BinkieRTTM(구강용 고정장치)에 대한 유용성 평가)

  • GyeongJin Lee;SangJun Son;GyeongDal Lim;ChanYong Kim;JeHee Lee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.34
    • /
    • pp.21-30
    • /
    • 2022
  • Purpose: The purpose of this study is to evaluate the effectiveness of oral positioning stent, the BinkieRTTM in radiation treatment for head and neck cancer patients in terms of tongue positions reproducibility, tongue doses and material properties. Materials and Methods: 24 cases using BinkieRTTM during radiation treatments were enrolled. The tongue was contoured on planning CT and CBCT images taken every 3 days during treatment, and then the DSC and center of tongue shift values were analyzed to evaluate the reproducibility of the tongue. The tongue dose was compared in terms of dose distribution when using BinkieRTTM and different type of oral stents (mouthpiece, paraffin wax). Randomly selected respective 10 patients were measured tongue doses of initial treatment plan for nasal cavity and unilateral parotid cancer. Finally, In terms of material evaluation, HU and relative electron density were identified in RTPS. Results: As a result of DSC analysis, it was 0.8 ± 0.07, skewness -0.8, kurtosis 0.61, and 95% CI was 0.79~0.82. To analyze the deviation of the central tongue shift during the treatment period, a 95% confidence interval for shift in the LR, SI, and AP directions were indicated, and a one-sample t-test for 0, which is an ideal value in the deviation(n=144). As a result of the t-test, the mean and SD in the LR and SI directions were 0.01 ± 0.14 cm (p→.05), 0.03 ± 0.25 cm (p→.05), and -0.08 ± 0.25 cm (p ←.05) in the AP direction. In the case of unilateral parotid cancer patients, the Dmean to the tongue of patients using BinkieRTTM was 16.92% ± 3.58% compared to the prescribed dose, and 23.99% ± 10.86% of patients with Paraffin Wax, indicating that the tongue dose was relatively lower when using BinkieRTTM (p←.05). On the other hand, among nasal cavity cancer patients, the Dmean of tongue dose for patients who used BinkieRTTM was 4.4% ± 5.6%, and for those who used mouthpiece, 5.9% ± 6.8%, but it was not statistically significant (p→.05). The relative electron density of Paraffin Wax, BinkieRTTM and Putty is 0.94, 0.99, 1.26 and the mass density is 0.95, 0.99 and 1.32 (g/cc), Transmission Factor is 0.99, 0.98, 0.96 respectively. Conclusion: The result of the tongue DSC analysis over the treatment period was about 0.8 and Deviation of the center of tongue shifts were within 0.2 cm, the reproducibility was more likely excellent. In the case of unilateral head and neck cancer patients, it was found that the use of BinkieRTTM rather than Paraffin Wax or Putty can reduce the unnecessary dose irradiated to the tongue. This study might be useful to understand of BinkieRTTM's properties and advantages. And also it could be another considered option as oral stent to keep the reproducibility of tongue and reducing dose during head and neck radiation treatments.