• 제목/요약/키워드: stent

검색결과 652건 처리시간 0.023초

양성 기관, 기관지 질환에서 확장성 금속 스텐트 사용에 관한 임상적 고찰 (Clinical analysis of expandble metallic stent in benign tracheal & bronchial disease)

  • 이성수;김도형;백효채;이두연
    • 대한기관식도과학회지
    • /
    • 제10권2호
    • /
    • pp.17-21
    • /
    • 2004
  • Background Insertion of tracheal stent in the treatment of benign tracheal & bronchial disease has increased since the introduction of expandable metallic stent. Material & Methods : Between Jan, 1995 and Feb. 2004, eight patients who had benign tracheo-bronchial disease underwent insertion of expandable metallic tracheal stent. We retrospectively analyzed stent insertion indications, complications, and following the result. Results : Surgical indications were post-intubation tracheal stenosis (1 case), tracheal stenosis following tracheal surgery (2 cases), tracheo-esophageal fistula (2 cases), broncho-pleural fistula(1 case), left main bronchus stenosis following bronchoplasty (1 case), and left main bronchus stenosis due to mediastinal repositioning (1 case). Expandable metallic tracheal stent was inserted in five patients to resolve dyspnea caused by airway obstruction, and to prevent recurrent pneumonia in three patients. The complication developed in 6 patients $75\%$; 3 cases of distal stenosis due to growth of granulation tissue, and one case each of tearing of posterior membrane, aggravation of tracheo-esophageal fistula, and airway partial obstruction due to stent migration. The stent was removed in 5 patients and tracheal surgery (tracheal resection and end to end anastomosis with primary repair of esophagus, pericardial patch tracheo-bronchoplasty, tracheal repair and omental wrapping) was performed in 3 patients. Conclusion Insertion of self expandable metallic stent in benign tracheo-bronchial disease is an effective means of relieving dyspnea for only a short period, and it did not increase the long term survival. Better means of treatment of benign tracheo-bronchial stenosis in necessary.

  • PDF

관상동맥혈관용 스텐트의 구조해석과 재료설계 (Material Design and Analysis of Coronary Artery Stents)

  • 박중권;강태원;이기성;김태우
    • 한국세라믹학회지
    • /
    • 제44권7호
    • /
    • pp.362-367
    • /
    • 2007
  • Stent is a tiny structure made with either ceramic coating and/or bare metal. Being approximately $1{\sim}2 mm$ in diameter, it consists of holes, slots, or void space and is designed to cover entire medical lesions. Stent implantation into patients' arteries has been practiced for a little more than a decade in order to widen the blocked artery. The adoption of the stent has significantly improved the efficacy when compared with the previous medical practice by balloon angioplasty alone. Yet better biomedical performance of the stent is being demanded in order to eliminate the still existing problem of artery restenosis, which means the artery becomes narrowed again. Recent literature survey shows researches on ceramic coatings onto the stent surface, or material design to improve the mechanical response of the stent. This study focuses more on the material design and mechanical analysis. The results showed that the void configuration within the stent affects the mechanical response significantly. The rectangular shape was found to yield expansion at a relatively lower pressure than the elliptical slot for a slotted tube stent. The present results, when combined with research on coating at the stent surface, may provide stents with improved bio-medical performance.

Selective Temporary Stent-Assisted Coil Embolization for Intracranial Wide-Necked Small Aneurysms Using Solitaire AB Retrievable Stent

  • Heo, Han Yong;Ahn, Jae Guen;Ji, Cheol;Yoon, Won Ki
    • Journal of Korean Neurosurgical Society
    • /
    • 제62권1호
    • /
    • pp.27-34
    • /
    • 2019
  • Objective : Stent-assisted coil embolization of intracranial wide-necked aneurysm requires long-term postoperative antiplatelet therapy to prevent in-stent thrombosis. This study aimed to demonstrate results of temporary stent placement for coiling wide necked small intracranial aneurysms, which eliminated need for antiplatelet agents, and to discuss its feasibility and safety. Methods : Data of 156 patients who underwent stent-assisted coil embolization between 2011 and 2014 were retrospectively analyzed. Thirteen cases of temporary stent-assisted coil embolization were included, and their clinical and radiological results were evaluated. Results : The aneurysms treated were all unruptured except one case. All of them had wide neck with mean dome-to-neck ratio of 0.96 and were small-sized aneurysms with mean maximal diameter of 4.2 mm. There was no technical failure in retrieval of stent after completion of embolization of the target aneurysm. Immediate angiography revealed 11 complete and two partial embolization (one residual neck and one residual aneurysm). Two cases encountered thrombosis complication, and they were managed without neurological sequelae. The mean follow-up period was 43 months, angiographic follow-up revealed two cases with minor recurrence, and clinical outcome was good with modified Rankin scale score of 0. Conclusion : Temporary stent-assisted coil embolization of small wide-necked intracranial aneurysm using fully retrievable stent appears safe and effective. Further application and evaluation of this technique in more cases with larger size aneurysm is warranted.

Feasibility of Percutaneous Pancreatic Stent Placement in Postoperative Pancreaticojejunostomy Stenosis

  • Juil Park;Kichang Han;Joon Ho Kwon;Man-Deuk Kim;Jong Yun Won;Sungmo Moon;Gyoung Min Kim
    • Korean Journal of Radiology
    • /
    • 제24권12호
    • /
    • pp.1241-1248
    • /
    • 2023
  • Objective: To evaluate the role of percutaneous pancreatic stent placement in postoperative pancreaticojejunostomy stenosis (PJS). Materials and Methods: This retrospective single-center study included seven procedures in five patients (four males and one female; median age, 63 years) who underwent percutaneous pancreatic stent placement for postoperative PJS between January 2005 and December 2021. The patients were referred to interventional radiology because of unfavorable anatomy or bowel abnormalities. The pancreatic duct was accessed under ultrasound and/or computed tomography guidance. A stent was placed after balloon dilatation of the PJS. Moreover, plastic stents were placed for the first two procedures, whereas bare-metal stents were used for the remaining five procedures. Technical success was defined as the successful placement of stents for the PJS, meanwhile, clinical success was defined as the normalization of pancreatic enzymes without recurrence of pancreatitis. Results: Pancreatic duct access and stent placement were successfully performed in all patients (technical success rate: 100%). All the procedures initially yielded clinical success. However, recurrence of pancreatitis was observed after two procedures that used plastic stents because of stent migration at 0.3 and 3 months after the procedure. In contrast, no instances of recurrent pancreatitis were noted after metal stent placement for a follow-up duration of 1-36 months. No serious procedure-related adverse events were observed. Conclusion: Percutaneous pancreatic stent placement may be a viable option for patients with postoperative PJS in whom an endoscopic approach is not feasible. Metal stents may be considered over plastic stents for the management of PJS, considering the possible lower stent migration and infeasibility of frequent endoscopic stent exchange due to the altered anatomy.

쥐 대장에서 스텐트 삽입 후 발생하는 조직 과증식 모델 형성을 위한 연구 (A Mouse Colon Model to Investigate Stent-Induced Tissue Hyperplasia)

  • 김민태
    • 한국방사선학회논문지
    • /
    • 제14권4호
    • /
    • pp.439-445
    • /
    • 2020
  • 본 연구는 쥐 대장 모델에서 자가팽창형 금속형 스텐트 삽입을 통한 삽입술의 유용성과 조직 과증식을 평가하고자 한다. 먼저 C57BL/6 쥐 대장의 직경을 확인하기 위해 1마리의 대장 투시조영 사전 실험을 실행하였다. 평균 직경은 4.05 mm였다. C57BL/6 쥐들은 두 군으로 나누어 각각 다른 스텐트의 직경을 비교 평가하였다. A 군은 직경이 5 mm, B군은 4mm 였다. 추적관찰 검사는 매주 투시를 통해 스텐트 삽입의 이상 유무를 평가하였다. 4주 후 내시경적 검사를 시행하고 희생하여 육안적 관찰 및 H&E 염색을 통해 조직 과증식을 평가하였다. 스텐트 삽입술은 시술 중 천공이 일어난 1마리를 제외하고 모든 쥐에서는 성공적으로 삽입되었다. 해당 데이터는 본 실험에서 제외하였다. 추적관찰 실험 기간에 A군에 속한 5마리의 쥐는 스텐트 삽입 후 7일 이내에 천공에 의해 사망하였다. B군의 1마리의 쥐는 곧창자로 스텐트의 이동이 발생하였다. A, B 군에서의 합병증은 각각 60%, 10%로 나타났다. 육안적 내시경적 결과에서는 모든 군에서 스텐트 와이어사이로 전체적인 조직 과증식이 일어남을 확인하였다. 조직병리에서의 결과 또한 두 군 사이의 통계적 차이는 유의하지 않게 조직 과증식이 일어났음을 확인할 수 있었다. 대장 스텐트의 삽입술은 기술적으로 유용하게 삽입이 가능했으며, 스텐트에 의한 조직 과증식이 쥐 모델에서 나타남을 확인하였다. 또한 스텐트 사이즈의 증가에 따라 쥐 대장내 천공이 많이 발생함을 확인할 수 있었다.

Unexpected Detachment of Solitaire Stents during Mechanical Thrombectomy

  • Kim, Sung Tae;Jin, Sung-Chul;Jeong, Hae Woong;Seo, Jung Hwa;Ha, Sam Yeol;Pyun, Hae Wook
    • Journal of Korean Neurosurgical Society
    • /
    • 제56권6호
    • /
    • pp.463-468
    • /
    • 2014
  • Objective : Unexpected Solitaire stent detachment can occur during mechanical Solitaire thrombectomy. The purpose of this study was to retrospectively evaluate the influencing factors causing unexpected Solitaire stent detachment and the clinical outcomes. Methods : Between October 2011 to December 2013, 232 cases of mechanical Solitaire thrombectomy for acute ischemic stroke were performed in 3 stroke centers. During this period, we encountered unexpected Solitaire stent detachments during mechanical Solitaire thrombectomies in 9 cases. Results : Solitaire stents unexpectedly detached in 9 cases (3.9%) during the retrieval of Solitaire stents. The median patient age was 76 years. The occlusion sites of the unexpected stent detachment were the proximal middle cerebral artery (MCA) in 7 cases and the internal carotid artery in 2 cases. The sizes of the stents that unexpectedly detached were $6{\times}30$ mm in 7 cases, $5{\times}30$ mm in 1 case, and $4{\times}20$ mm in 1 case. Four patients had unexpected detachment at the first retrieval, 1 patient at the second, 3 patients at the third, and 1 patient at the fifth. In all of the cases of unexpected detachment at the first retrieval, the stent deployment site was the proximal MCA. After detachment, a proximal marker of the Solitaire stent was observed in 3 patients. However, no marker was visible in the remaining 6 patients. Conclusion : Unexpected Solitaire stent detachment should be considered in the first instance of stent retrieval for a relatively large-diameter stent, especially in elderly patients with MCA occlusions.

정관내 부목을 이용한 정관복원술 : Permanent Silicone Stent의 효용가치 (Effectiveness of Permanent Silicone Stent-Assisted Vasovasostomy)

  • 김태형;김세철
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제23권1호
    • /
    • pp.67-71
    • /
    • 1996
  • During a 2-year period microsurgical vasovasostomies using permanent silicone stent(c-shaped stent with 0.6mm slit, 5mm in length, 0.8mm in outer diameter, 0.5mm in inner diameter) were performed in 30 patients for vasectomy revesal. The stent-assisted vasovasostomy(SVV) was intended to decrease the technical demand, the time requirement and the occurrence of reobstruction due to postoperative stricture. The effectiveness of the permanent silicone stent for vasovasostomy was compared with that of microsurgical two-layered vasovasostomy(VV). Sperms were present in all the ejaculates of the 25 men on semen analysis 1-2 months after SVV. Pregnancy occurred in 10 of 22 couples(45.5%) during 2-24 months of follow-up and it took 4-10 months(average 7.2 months) to get pregnant. Average operation time for the VV was 150 minutes and that for the SVV 125 minutes. Among 12 men who had sperms in the ejaculates 1-2 months after SVV, 4 revealed azoospermia 3-17 months postoperatively. Among the 4 patients with postoperative azoospermia, 2 underwent reoperation. On histopathologic examination, previously anastomsed sites showed obliterated lumen of the stent and strictures of vas proximal and/or distal to the stents due to granulation tissues. In conclusion, the SVV was not more efficacious in terms of patency and pregnancy rate than the VV.

  • PDF

Bilateral Vertebral Artery Dissecting Aneurysms Presenting with Subarachnoid Hemorrhage Treated by Staged Coil Trapping and Covered Stents Graft

  • Yoon, Seok-Mann;Shim, Jai-Joon;Kim, Sung-Ho;Chang, Jae-Chil
    • Journal of Korean Neurosurgical Society
    • /
    • 제51권3호
    • /
    • pp.155-159
    • /
    • 2012
  • The treatment of bilateral vertebral artery dissecting aneurysms (VADAs) presenting with subarachnoid hemorrhage (SAH) is still challenging. The authors report a rare case of bilateral VADA treated with coil trapping of ruptured VADA and covered stents implantation after multiple unsuccessful stent assisted coiling of the contralateral unruptured VADA. A 44-year-old woman was admitted to our hospital because of severe headache and sudden stuporous consciousness. Brain CT showed thick SAH and intraventricular hemorrhage. Cerebral angiography demonstrated bilateral VADA. Based on the SAH pattern and aneurysm configurations, the right VADA was considered ruptured. This was trapped with endovascular coils without difficulty. One month later, the contralateral unruptured VADA was protected using a stent-within-a-stent technique, but marked enlargement of the left VADA was detected by 8-months follow-up angiography. Subsequently two times coil packing for pseudosacs resulted in near complete occlusion of left VADA. However, it continued to grow. Covered stents graft below the posterior inferior cerebellar artery (PICA) origin and a coronary stent implantation across the origin of the PICA resulted in near complete obliteration of the VADA. Covered stent graft can be used as a last therapeutic option for the management of VADA, which requires absolute preservation of VA flow.

Temporary Semi-Jailing Technique for Coil Embolization of Wide-Neck Aneurysm with Small Caliber Parent Artery Following Incomplete Clipping

  • Byun, Jun Soo;Kim, Jae Kyun;Lee, Hwa Yeon;Hwang, Sung Nam
    • Journal of Korean Neurosurgical Society
    • /
    • 제53권4호
    • /
    • pp.241-244
    • /
    • 2013
  • The authors describe the use of a self-expandable stent in a temporary deployment for treatment of a very wide-neck A1 segment of anterior cerebral artery (ACA) aneurysm following incomplete clipping. A 39-year-old hypertensive man presenting with seizure-like movement underwent computed tomography, which showed acute subarachnoid hemorrhage and an A1 segment of ACA aneurysm with superior and inferior projection. He underwent surgical clipping of the aneurysm, but superior and posterior portion of wide-neck aneurysm remained. We decided to treat the remnant aneurysm using an endovascular modality. After selection of the aneurysm, coil packing was performed assisted by the temporary semi-jailing technique. The Enterprise stent (Cordis Neurovascular, Miami, FL, USA) was deployed and recaptured repeatedly for angiography to ensure safety of the small caliber parent artery. Successful semi-deployment and recapture of the stent allowed subtotal coil occlusion of the aneurysm with good anatomic and clinical results. No complications were encountered. The stent could be recaptured up to the point where the proximal end of the stent marker was aligned with distal marker band of the microcatheter, approximately 70% of the stent length. The temporary semi-jailing technique is feasible for wide-neck aneurysm with small caliber parent artery.

풍선확장식 스텐트의 기계적 특성에 대한 유한요소해석 (Finite Element Analysis of Mechanical Properties of a Balloon-Expandable Stent)

  • 오병기;조해용;김용연
    • 대한기계학회논문집A
    • /
    • 제28권7호
    • /
    • pp.915-922
    • /
    • 2004
  • A stent is small tube-like structure expanded into stenotic arteries to restore blood flow. The stent expansion behaviors define the effectiveness of the surgical operation. In this paper, finite-element method was employed to analyze expansion behaviors and fatigue life of a typical diamond-shaped balloon-expandable stent. Beyond safety considerations, this type of analysis provides mechanical properties that are often difficult to obtain by experiments. Mechanical properties of the stent expansion pressure, radial recoil, longitudinal recoil and foreshortening were simulated using commercial FEM code, ANSYS and fatigue life were estimated using NISAII ENDURE. The FEM results showed that the pressures necessary to expand the stent up to a diameter of 3mm, 4mm and 5mm were 0.75MPa, 0.82MPa and 0.97MPa. The fatigue lifes according to expansion diameter were 114${\times}$10$^{7}$cycles, 714${\times}$$^{6}$cycles and 163${\times}$10$^{6}$cycles. As a result, a finite element model used in this study can simulate expansion behaviors of stents and should be useful to design new stents or analyze actual stents.