• Title/Summary/Keyword: stem fire

Search Result 22, Processing Time 0.021 seconds

Diagnosis for damage of fire hydrant with long valve stem in power plant. (발전소내 긴 밸브 stem을 갖는 옥외 소화전의 파손 현상 규명)

  • Sohn, Seok-Man;Lee, Sang-Guk;Lee, Wook-Ryun;Lee, Jun-Shin;Kim, Ki-Tae
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3512-3517
    • /
    • 2007
  • Nuclear power plant has many external fire hydrants that have to operate in the state of emergency such as facility fire, forest fire. The valve stem of one among them was broken 3 times for 4 years. It had long valve stem and operated under high water pressure. The elongation and the tensile strength for the broken valve stem was measured to examine the defect of material property. And the vibration level and the natural frequencies was detected to check the resonance. As the result of a diagnosis, the cause of this fault is proven buckling of long valve stem.

  • PDF

A Study on the Afforestation of Fire-Resistant Forest through an Application of Forest Fire Investigation (산림 화재감식 응용을 통한 내화림 조성에 관한 연구)

  • Park, Young-Ju
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.5
    • /
    • pp.118-129
    • /
    • 2011
  • In this study, species resistant to forest fire were extracted from high trees through an investigation of combustion mechanism. Here, the average flameless ignition temperatures of living leaves, branches and barks of oak were respectively, $365^{\circ}C$, $440^{\circ}C$ and $435^{\circ}C$, and the average flameless ignition temperatures of living leaves, branches, barks and cones of pine tree were respectively, $320^{\circ}C$, $405^{\circ}C$, $435^{\circ}C$ and $363^{\circ}C$. It shows that generally, pine tree has a lower flameless ignition temperature than oak and thus, has a relatively high risk of flameless ignition. When comparing risk of fire depending on ignition characteristics, Quercus serrata had a low risk of stem fire, and Quercus acutissima and Quercus serrata had a low risk of crown fire, as well. When analysing risk of fire depending on a duration of flame, also, Quercus dentata had a low risk of stem fire, and Quercus variabilis Blume had a low risk of crown fire too. Lastly, when comparing risk of fire, according to heat release rates, Quercus acutissima had a low risk of stem fire, and Quercus acutissima and Quercus dentata had a low risk of crown fire, as well. In conclusion, it was observed that as fire-resistant species, Quercus serrata and Quercus dentata have a low risk of ignition, Quercus variabilis Blume has a short duration of flame after discharging ignition when a forest fire occurs, and Quercus acutissima, Pinus Rigida and Antipathes japonica Brook have low heat release rates.

Analysis of Fire Direction and Pine Tree Survival using to Fire Scar formed in Tree Stem after forest Fire (산불발생 후 불자국을 이용한 소나무 생존 및 지형에 따른 산불의 방향 분석)

  • 채희문;이찬용
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.5 no.1
    • /
    • pp.30-35
    • /
    • 2003
  • The study of the scars formed on the bark of pine trees damaged by forest fire was carried out in the burned area of Samchuk and Donghae in 2000. Fire scars were formed on the bark of trees when fire passed by the tree. Fire scarring is usually found on the windward and leeward sides of the tree. Fire spread was analyzed topographically using the fire scars formed at the tree stem. Fire spread was closely related to the shape, slope and direction of the forestland. Four fire direction types are classified according to the shapes of the forestland. The height of the fire scar was higher on the leeward side than on the windward side of the trees studied. The burnt area of the total bark of the tree was over 30% in dead trees and below 12% in living trees. The regression model of the burnt stem area using the height of the fire scar, the diameter of breast height and the height of tree was Y=-2.484${\times}$Height+0.04199${\times}$D.B.H-1.686${\times}$Windward+11.172${\times}$Leeward+23.432(r=0.936, F=409.968, P>0.0001).

Untestable Faults Identification Using Critical-Pair Path (임계-쌍 경로를 이용한 시험 불가능 결함의 확인)

  • 서성환;안광선
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.36C no.10
    • /
    • pp.29-38
    • /
    • 1999
  • This paper presents a new algorithm RICP(Redundancy Identification using Critical-pair Paths) to identify untestable faults in combinational logic circuits. In a combinational logic circuit, untestable faults occurred by redundancy of circuits. The redundancy of a circuit can be detected by analyzing areas of fanout stem and reconvergent gates. The untestable faults are identified by analyzing stem area using Critical-Pair path which is an extended concept of critical path. It is showed that RICP is better than FIRE(Fault Independent REdundancy identification) algorithm in efficiency. The performance of both algorithms was compared using ISCAS85 bench mark testing circuits.

  • PDF

Influence on forest fire spread & intensity on fuel type of burnt area. (산불피해지역 연료형태가 산불연소에 미치는 영향)

  • Lee, Si-Young;Lee, Myung-Woog;Yeom, Chan-Ho;Kwon, Chun-Geun;Park, Houng-Sek;Lee, Hae-Pyeong
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.321-324
    • /
    • 2008
  • Forest fire danger rate of thinning area was lower than that of non thinning area, because height rate of leewardside in burned stem of tree, damage rate of crown and mortality of tree in thinning area were 30.8%, 37% and 48.4% lower than that in non-thinning area, respectively. Intensity of forest fire varied depending upon topographical condition up slope, down slope, aspect, location as well as species, breast height diameter and forest tree density. Especially, a mountaintop area was burned down when forest fire was spread to up slope ridge of mountain.

  • PDF

Influence of the Objectionable Stems on the Physical Characteristics during the Cigarette Combustion (부적합 엽맥편이 궐련의 연소중 물리적 특성에 미치는 영향)

  • Kim Soo-Ho;Park Won-Jin;Kim Jong-Yeol;Rhee Moon-Soo
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.28 no.1
    • /
    • pp.23-30
    • /
    • 2006
  • In order to improve the final product quality, tobacco industry has gradually decreased the size and number of steams in the cigarette. Especially, steams bigger than $3{\times}3$ mm($length{\times}thickness$) and $2{\times}10$ mm($width{\times}length$) are not acceptable in the process as objectionable stems. A total number of 12 samples where the $length{\times}tickness$ samples were prepared by decreasing the present sample ($3{\times}3$ mm) with 1 mm up to $1{\times}1$ mm, and the $width{\times}length$ samples were prepared by decreasing the present sample ($2{\times}10$ mm) with 2 mm up to $2{\times}6$ mm for the stems in leaf and stems in expanded cut-tobacco were prepared to apply a fire ball drop test using stems. In addition, cigarettes were produced for these stems in order to analyze the forced fire ball drop including the burning, encapsulation and unencapsulation pressure drop and a single or unspecified direction combustion. Based on the results of the test, it was evident that the fire ball drop in the stems in expanded cut-tobacco presented a lower level than that of the stems in leaf. Also, the stems in expanded cut-tobacco presented a larger swelling and higher burning for a single direction than that of the stem in leaf. In addition, it was considered that the management criteria for objectionable stems should be changed as $3{\times}3$ mm and $2{\times}8$ mm for the $length{\times}thickness$ and $width{\times}length$ sample, respectively, in both steams in leaf and expanded cut-tobacco.

Comparative Analysis of Mortality in Species of Trees after Surface Forest Fire (지표화 산불피해지의 수종별 임목 고사율 비교분석)

  • Lee, Si-Young;An, Sang-Hyun
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.2
    • /
    • pp.39-43
    • /
    • 2009
  • we studied and analyzed a tree mortality of 7 species(Pinus koraiensis etc) in surface forest fire area. In this results, the order of tree mortality was Cryptomeria japonica>Pinus koraiensis>Pinus densiflora>Pinus thunbergii>Larix leptolepis>Pinus rigida>Quercus. More damaged crown was higher tree mortality and more d.b.h was less tree mortality. Especially, oak trees in which a damage rate of crown was less 30% almost survived.

Relation Between Water Content Ratio and Fire Performance of Class 1 Structural Light Weight Aggregate Concrete (1종 경량골재콘크리트의 함수율과 내화특성)

  • Song, Hun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.2 no.4
    • /
    • pp.321-327
    • /
    • 2014
  • Structural light weight aggregate concrete are made with both coarse and fine light weight aggregates, but it is common with the high strength concrete to replace all or part with normal weight sand be called class 1 structural light weight aggregate concrete. Fire resistance of structural light weight aggregate concrete are determined by properties of high water content ratio and explosive spalling. Especially, structural light weight aggregate concrete is occurred serious fire performance deterioration by explosive spalling stem from thermal stress and water vapor pressure. This study is concerned with experimentally investigating fire resistance of class 1 structural light weight concrete. From the test result, class 1 structural light weight concrete is happened explosive spalling. The decrease of cross section caused by explosive spalling made sharp increasing gradient of inner temperature.

Mortality in Pine Stand and Vegetation Recovery after Forest Fire (산불발생 후 소나무 피해 및 식생복원 실태분석)

  • Lee, Si-Young;Jun, Kye-Won;Lee, Myung-Woog;Chun, Kun-Woo
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.1
    • /
    • pp.71-79
    • /
    • 2008
  • To find out the effect of the vegetation recovery and the problems of forest land, the researches of the mortality in pine stand and vegetation recovery have been carried out from the burned site. In area which is damaged by fire scar on crown and stem, rate of dead is higher. Where stand growing stocks were totally damaged by crown forest fire, most of vegetation was recovered by sprouts and planted seeds. Vegetation recovery power were depending on the condition of soil depth condition. For the artificial recovery, the damage happened by insects in the planted birches plantation. Rate of growth was somewhat different between Pinus densiflora and Pinus thunbergii in the plantation, because of individual growth rate.