• Title/Summary/Keyword: steel wire mesh

Search Result 60, Processing Time 0.021 seconds

A new precast wall connection subjected to monotonic loading

  • Vaghei, Ramin;Hejazi, Farzad;Taheri, Hafez;Jaafar, Mohd Saleh;Ali, Abang Abdullah Abang
    • Computers and Concrete
    • /
    • v.17 no.1
    • /
    • pp.1-27
    • /
    • 2016
  • Final construction project cost is significantly determined by construction rate. The Industrialized Building System (IBS) was promoted to enhance the importance of prefabrication technology rather than conventional methods in construction. Ensuring the stability of a building constructed by using IBS is a challenging issue. Accordingly, the connections in a prefabricated building have a basic, natural, and essential role in providing the best continuity among the members of the building. Deficiencies of conventional precast connections were observed when precast buildings experience a large induced load, such as earthquakes and other disasters. Thus, researchers aim to determine the behavior of precast concrete structure with a specific type of connection. To clarify this problem, this study investigates the capacity behavior of precast concrete panel connections for industrial buildings with a new type of precast wall-to-wall connection (i.e., U-shaped steel channel connection). This capacity behavior is compared with the capacity behavior of precast concrete panel connections for industrial buildings that used a common approach (i.e., loop connection), which is subjected to monotonic loading as in-plane and out-of-plane loading by developing a finite element model. The principal stress distribution, deformation of concrete panels and welded wire mesh (BRC) reinforcements, plastic strain trend in the concrete panels and connections, and crack propagations are investigated for the aforementioned connection. Pushover analysis revealed that loop connections have significant defects in terms of strength for in-plane and out-of-plane loads at three translational degrees of freedom compared with the U-shaped steel channel connection.

Effect of utilizing pressurized ring beam system in modern rock TBM: I. Numerical study (현대식 Rock TBM에서 가압형 링빔의 효과 연구: I. 수치해석적 연구)

  • Kwak, Yun-Suk;Kang, Gi-Don;Kim, Do-Hoon;Lee, In-Mo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.14 no.1
    • /
    • pp.55-77
    • /
    • 2012
  • A Modern Rock TBM is a tunnel excavation method combining the conventional tunnelling method with the mechanized tunnelling method. It is a hybrid system that excavates a tunnel with TBM and supports the ground by ring beam, wire mesh, rock bolt, shotcrete, i.e., conventional tunnelling method. In the Modern Rock TBM, a ring beam is similar to a steel rib in NATM in the way that uses H-beam. But using a ring beam is more effective than a steel rib because it is installed in a closed-circle. Therefore, improving the performance of the ring beam is a key factor for achieving tunnel stability. In this respect, this study introduces a pressurized ring beam that might be functioning more effectively by confining convergence during tunnel excavation. In order to verify the effect of the pressurized ring beam, a three-dimensional numerical analysis was conducted. The numerical analysis confirms an increase in the minimum principal stress and reduction in the plastic strain that triggers excessive displacement. The analysis result also indicates a decrease in the relative displacement occurring after installing the ring beam, and expansion in spacing between the ring beams.

Experimental Study on the Retrofit Method to Improve the Structural Capacity of Reinforced Concrete Shear Wall (철근콘크리트 전단벽의 구조성능개선을 위한 보강방안에 관한 실험적 연구)

  • Ha, Gee-Joo;Seo, Soo-Yeon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.4
    • /
    • pp.79-86
    • /
    • 2008
  • Four RC shear wall specimens with a/d of 2.2 are designed. And a flexural retrofitting is performed for one specimen by both enlarging wall section and adding additional vertical reinforcements. Also the effectivity of jaketting wall sides is evaluated for the two methods using only steel plate or welded wire mesh with enlargement of section. Cyclic loads are applied to the retrofitted specimens according to the loading history proposed by ACI under constant axial force. Test result showed that the strength and ductility of specimen were improved where the section was enlarged after the installation of additional vertical reinforcements. Confining the ends of wall by U shape W.W.F. with enlargement of section showed most excellent structural capacity regarding to the strength and ductility. Retrofitting by using steel plate was much effective not only to protect the abrupt decrease of strength after yield but also to improve the deformation capacity.

Formation Control of Calcium and Magnesium Compounds by Electrodeposition Process in Seawater (해수 중 전착 프로세스에 의한 칼슘 및 마그네슘 화합물의 형성 제어)

  • Park, Jun-Mu;Hwang, Seong-Hwa;Choe, In-Hye;Gang, Jun;Lee, Myeong-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.164-164
    • /
    • 2017
  • 해양환경 중 많이 사용되는 철강재료들은 그 가혹한 부식환경에 대응하기 위하여 일반적으로 피복 도장방식법이나 음극방식법이 적용되고 있다. 여기서 음극방식법은 선박 및 해양구조물의 해중부 부식에 대해 가장 효과적인 방식법으로 알려져 있다. 한편, 이와 같이 해수 중 철강재에 음극방식을 적용할 경우, 피방식체인 그 강재 표면에 해수 중 용존된 산소의 음극환원 반응이 일어나며 국부적인 알카리 표면 조건을 형성시켜 $Mg(OH)_2$$CaCO_3$의 막을 석출시킨다. 이와같이 음극방식 중 형성된 전착물은 방식해야 될 표면적을 감소시켜 방식전류밀도를 감소시키는 효과가 있는 것으로 보고되고 있다. 이렇게 석출된 전착물은 음극표면에 부분적으로 형성되고, 여러 가지 환경 조건 등의 영향을 받아 그 피막의 형성 정도도 가늠하기 어렵기 때문에 음극방식 설계 시 그 정도에 따른 영향을 고려-반영하기가 곤란하다. 또한 이 전착물은 그 형성 메커니즘에 관한 해석이나 강도, 균일한 밀착성, 장기적인 방식효과 및 효율성 등이 아직 충분히 입증되어 있지 않은 실정에 있다. 따라서 본 연구에서는 해수 중 다양한 전착 프로세스에 의해 제작된 전착물의 기간별, 도장코팅 종류별 특성변화를 분석 및 평가하고, 전착물에 의한 희생양극 소모전류 변화 측정 분석을 통해 전착막을 균일하고 치밀하게 형성시키기 위한 최적의 조건을 찾고자 하였다. 또한 석출속도, 밀착성 및 내식특성을 향상시키기 위해 해수 중 기체를 용해시켜 제작한 막의 특성을 분석-평가하였다. 본 연구에 사용된 강 기판은 일반구조용강(KS D 3503, SS400)으로 ${\varnothing}42.7{\times}1,000mm{\times}4.0t$의 형상으로 제작하였다. 인가된 전류밀도는 1, 3 및 $5A/m^2$이고 도장 코팅 종류별 전착 석출물의 형성차이 비교 분석을 위한 실험은 선박 및 해양구조물에 많이 사용되는 Universal Epoxy 도료 2종을 선정하여 진행하였다. 또한 Steel Wire Mesh의 영향을 알아보기 위해 Mesh를 설치하여 실험을 진행하였다. 기간별-도장 종류별 외관관찰, 전착물의 두께 측정, SEM, EDS 및 XRD를 통해 막의 모폴로지, 조성원소 및 결정구조를 분석하였으며, 전착물의 내식성과 내구성을 평가하기 위해 테이핑 테스트(Taping Test) 및 전기화학적 양극분극 시험을 실시하였다. 희생양극 소모율에 대한 전착물의 영향을 확인하기 위해 외부전원을 인가하여 전착 피막을 형성시킨 강 기판에 희생양극을 연결하여 희생양극 소모효율 측정 시험을 진행하였다. 전착물의 석출량은 시간 및 전류밀도의 증가에 따라 비례하여 증가하였으며, 음극전류 인가 시 금속과 용액 계면 사이의 확산층에서 발생한 $OH^-$ 이온으로 인해 금속과 용액 계면 사이 pH가 부분적으로 증가하여 $Mg(OH)_2$ 화합물이 많이 생성되는 것으로 확인되었다. 또한 Mesh의 부착으로 평활하지 않게 형성된 미세한 굴곡구조 및 표면적 증가로 인하여 단계적으로 피복되는데 필요한 시간이 지연되면서 $CaCO_3$에 비해 $Mg(OH)_2$ 화합물이 상대적으로 증가한 것으로 사료된다. $CaCO_3$(Aragonite) 구조는 견고한 피막으로 치밀하고 화학적 친화력이 높아 우수한 밀착성을 보였으며 전착물의 영향으로 양극 전류가 감소하였고, 이로인해 방식전류 절감효과를 얻을 수 있을 것으로 기대된다.

  • PDF

Torque control during lingual anterior retraction without posterior appliances

  • Mo, Sung-Seo;Kim, Seong-Hun;Sung, Sang-Jin;Chung, Kyu-Rhim;Chun, Yun-Sic;Kook, Yoon-Ah;Nelson, Gerald
    • The korean journal of orthodontics
    • /
    • v.43 no.1
    • /
    • pp.3-14
    • /
    • 2013
  • Objective: To evaluate the factors that affect torque control during anterior retraction when utilizing the C-retractor with a palatal miniplate as an exclusive source of anchorage without posterior appliances. Methods: The C-retractor was modeled using a 3-dimensional beam element (0.9-mm-diameter stainless-steel wire) attached to mesh bonding pads. Various vertical heights and 2 attachment positions for the lingual anterior retraction hooks (LARHs) were evaluated. A force of 200 g was applied from each side hook of the miniplate to the splinted segment of 6 or 8 anterior teeth. Results: During anterior retraction, an increase in the LARH vertical height increased the amount of lingual root torque and intrusion of the incisors. In particular, with increasing vertical height, the tooth displacement pattern changed from controlled tipping to bodily displacement and then to lingual root displacement. The effects were enhanced when the LARH was located between the central and lateral incisors, as compared to when the LARH was located between the lateral incisors and canines. Conclusions: Three-dimensional lingual anterior retraction of the 6 or 8 anterior teeth can be accomplished using the palatal miniplate as the only anchorage source. Using LARHs at different heights or positions affects the quality of torque and intrusion.

Fundamental Study on the Strength and Heat Transferring Charcteristic of Cement Composite with Waste CNT (폐CNT를 혼입한 시멘트 복합체의 강도 및 열전달 특성에 대한 기초적 연구)

  • Koo, Hounchul;Kim, Woon-Hak;Oh, Hongseob
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.1
    • /
    • pp.66-73
    • /
    • 2022
  • The purpose of this study was to develop self-heating concrete by utilizing the conduction resistance of concrete in order to reduce the risk of occurrence of black ice in the concrete pavement in winter and to prevent damage caused by freez-thawing effect. For this purpose, it was attempted to evaluate the strength and temperature exothermic characteristics using powder and liquid waste CNTs and a waste cathode agent as a conduction promotion. It was analyzed that liquid waste CNT had an effective dispersion degree in the mortar and a small decrease in strength occurred. In addition, DC 24 V was supplied by applying steel mesh, copper foil and copper wire to the mortar as electrodes, and the temperature change characteristics according to the mixing ratio of spent CNTs, anodes and carbon fibers were evaluated. In addition, by evaluating the temperature characteristics according to the electrode spacing from the selected optimal mixture, it was confirmed that it had sufficient heating characteristics up to an electrode spacing of 100 mm up to AC 50 V.

Crack Example and Crack Control Method of Very-Early Strength Latex-Modified Concrete (초속경 라텍스개질 콘크리트의 균열발생 사례 및 억제방안)

  • Choi, Pan-Gil;Yun, Kyong-Ku;Lee, Bong-Hak
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.3 s.55
    • /
    • pp.173-180
    • /
    • 2009
  • Very-early strength latex-modified concrete(below ; VES-LMC) was developed for possible early-opening-to-traffic after overlay of bridge deck concrete. The purpose of this study is to analyze the cause of map, transverse and longitudinal cracking in VES-LMC and to provide a control method for minimizing occurrence of cracking. The proposed prevention method against map and transverse cracking was verified by field data. VES cement was modified as the unit cement content was reduced from 390kg/$m^3$ to 360kg/$m^3$. The maximum size of coarse aggregate was increased from 13mm to 19mm. The wire mesh and steel fiber were adopted in concrete mixture. From the results, the proposed prevention method against map and transverse cracking was verified since structural cracking was not occurred until 3 years after overlay.

Pull-out Capacity of Cast-in-place Anchor for Construction of Precast Concrete Segment Arch (프리캐스트 콘크리트 패널 분절 아치 시공을 위한 선설치 앵커의 인발 강도 평가)

  • Ahn, Jin-Hee;Yim, Hong Jae;Bang, Jin Soo;Jeon, Seok Hyeon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.2
    • /
    • pp.94-102
    • /
    • 2020
  • Precast concrete segment arch system has an economic and construct ability that combined with advantage of precast concrete and arch behavior. A precast concrete segment arch system with outrigger is consisted of segmented precast panels, a steel outrigger rib, and V-strip to connect precast panels with a steel outrigger rib and cast-in-place anchors in precast panels to connect V-strip should have sufficient pull-out capacity to form its arch shape by site lifting for assembled precast panels and outriggers. However, it is difficult to secure its embedment depth due to the relatively shallow thickness of precast panel. It can be also occurred that flexure deformation of precast panels caused by its pull-out behaviors. In this study, pull-out capacity of cast-in-place anchor was examined for construction of precast concrete segment arch system with outriggers. Therefore, a total of 24 precast panel specimens were fabricated to examine pull-out capacities of cast-in-place anchor in precast panels, and installation depth of anchors, diameter of anchors and wire mesh effects for the precast panel were examined. From this pull-out tests, its pull-out capacities and failure modes were evaluated and the type of the cast-in-place anchor applicable to the precast concrete segment panel arch system with outriggers was determined from comparison of the design specification values.

TOPICAL GENE DELIVERY TO NORMAL ORAL EPITHELIUM USING ADENOVIRUS IN ORGAN CULTURE MODEL (조직 배양 모형에서 정상 구강 점막 상피에 대한 국소 유전자 요법)

  • Kim, Tae-Hwan;Kwak, Myung-Ho;Lee, Choon-Ho;Park, Jun-Woo;Park, Young-Wook;Kim, Seong-Gon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.3
    • /
    • pp.193-197
    • /
    • 2009
  • Background: Though it is clear that many types of viruses can infect the oral mucosa, its condition for infection is unclear. The purpose of this study was to analyze the conditions for viral infection of normal oral mucosa and explore the possibility of topical gene therapy to oral mucosa using a viral vector. Methods: Freshly taken fragments of the palate and the tongue of mice were used for organ culture. The specimens were exposed to green fluorescent protein (GFP)-adenoviral vector for 1 hour except for the control. Initial viral titer was $6.3{\times}10^{11}\;pfu/ml$ and the virus was diluted to working concentrations. The dilution ratio was 1:1,000 ($6.3{\times}10^8\;pfu/ml$), 1:10,000 ($6.3{\times}10^7\;pfu/ml$), and 1:100,000 ($6.3{\times}10^6\;pfu/ml$). They were then cultured on a stainless steel wire mesh in an organ culture dish. The specimens were stereoscopically examined every 24 hours for 6 days, after which they were fixed and analyzed through immunohistochemical methods Results: There was no visible expression in the control, $6.3{\times}10^6\;pfu/ml$, and $6.3{\times}10^7\;pfu/ml$ groups. Initial expression was observed at 24 hours after infection in both the palate and the tongue in $6.3{\times}10^8\;pfu/ml$ and the expression significantly increased until 3 days in the palate and 2 days in the tongue after infection (P<0.05). In both groups, the expression was mostly observed at the resection margin. Immunohistochemical studies showed that the epithelial cells were positive to GFP. Conclusion: The present study showed that topically applied adenovirus containing specific genetic information of GFP could successfully transduce GFP in normal oral epithelial cells at the resection margin in organ culture in terms of dose and exposure time.

Variation of Nephrotoxicity Biomarkers by Urinary Storage Condition in Rats

  • Lee, Jung-Min;Han, Young-Hwan;Choi, Su-Jeong;Park, Ju-Seong;Jang, Jeong-Jun;Bae, Re-Ji-Na;Lee, Mi Ju;Kim, Myoung Jun;Lee, Yong-Hoon;Kim, Duyeol;Lee, Hye-Young;Park, Sun-Hee;Park, Cheol-Beom;Kang, Jin Seok;Kang, Jong-Koo
    • Toxicological Research
    • /
    • v.30 no.4
    • /
    • pp.305-309
    • /
    • 2014
  • Recently, there has been an increase in the use of several nephrotoxicity biomarkers in preclinical experiments. In addition, it has been indicated that the result may have been influenced by secondary factors, such as sample storage condition or storage period. In this study, we have assessed the variation in urinary nephrotoxicity biomarkers as a result of urine storage conditions and storage period of the urine. Urine was sampled from specific pathogen-free Sprague-Dawley rats (19 weeks old), which were housed individually in hanged stainless steel wire mesh cages. Urine was stored at $20^{\circ}C$, at $4^{\circ}C$, or at $-70^{\circ}C$ after sampling. The levels of the biomarkers such as beta-2 microglobulin (B2M), cystatin-C (Cys-C), N-acetyl-${\beta}$-D-glucosaminidase (NAG), micro albumin (MA), micro protein (MP) were measured at 6, 24, 48 and 144 hr after sampling. The B2M level was significantly decreased at 6, 24, 48, and 144 hr compared to 0 hr at $-70^{\circ}C$ (p < 0.05, p < 0.01, p < 0.05, and p < 0.05, respectively) and 24 and 144 hr at $20^{\circ}C$ (p < 0.01, p < 0.01, respectively). The Cys-C level was significantly decreased at 144 hr compared to 0 hr at $4^{\circ}C$ (p < 0.01), at $20^{\circ}C$ (p < 0.05) and at $70^{\circ}C$ (p < 0.01). MP and MA levels were not different for 144 hr in all storage conditions. Taken together, B2M and Cys-C levels were modulated by storage temperature and period. For the enhancement of test accuracy, it is suggested that strict protocols be established for samples to minimize the effects of the storage conditions on the detected levels of biomarkers.