• 제목/요약/키워드: steel fiber reinforcement

검색결과 473건 처리시간 0.025초

앙칼리 환경하에서 콘크리트 보강용 GFRP rebar의 열화현상 평가 (Deterioration of GFRP rebar in alkaline solution)

  • 원종필;이수진;장창일;박찬기;김정훈;박영환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계 학술발표회 논문집(II)
    • /
    • pp.237-240
    • /
    • 2006
  • The corrosion of steel reinforcing bar has been the major cause of the reinforced concrete deterioration. GFRP(Glass Fiber-Reinforced Polymer) reinforcing bar has emerged as one of the most promising and affordable solutions to the corrosion problems of steel reinforcement in structural concrete. However, GFRP rebar is prone to deteriorate due to other degradation mechanisms than those for steel. The high alkalinity of concrete, for instance, is a possible degradation source. This paper presents the long-term deterioration of the GFRP rebar under alkali environmental condition.

  • PDF

강섬유 혼입률과 피복두께에 따른 GFRP 보강근의 부착특성 (Bond Properties of GFRP Rebar with Cover Thickness and Volume Fraction of Steel Fiber)

  • 최윤철
    • 콘크리트학회논문집
    • /
    • 제24권6호
    • /
    • pp.761-768
    • /
    • 2012
  • 이 연구는 강섬유 혼입률에 따른 피복두께와 GFRP 보강근의 부착특성을 부착응력-미끌림 관계를 통하여 평가하였다. 실험변수로는 강섬유 혼입률을 0%, 1%, 2%로 하였고 피복두께는 보강근 직경($d_b$)의 $1.5d_b$$5.4d_b$로 하였다. GFRP 보강근의 직경은 D13과 D16 두 가지를 사용하였으며, 비교실험을 위하여 이형철근을 사용하였다. 실험 결과 피복두께에 따 상이한 파괴형태를 취했으며, 작은 피복두께를 갖는 $1.5d_b$의 경우 쪼갬파괴 형태를 취했고 충분한 피복두께인 $5.4d_b$를 갖는 경우 뽑힘파괴 형태를 취했다. 이에 강섬유 혼입률을 증가시켰음에도 파괴형태에는 영향이 없었다. 그러나 강섬유 혼입률의 증가에 따라 최대부착응력 도달 후 급작스런 부착응력 감소폭이 감소하였다. 또한, 작은 피복두께를 갖는 경우 최대부착응력에 도달 전에 파괴되면서 강섬유 혼입률에 따른 부착응력의 차이가 거의 없었지만, 충분한 피복두께를 갖는 경우에는 최대부착응력에 도달 하면서 강섬유 혼입률 증가에 따라 부착응력이 증가하였다. 이는 강섬유의 가교작용으로 인해 콘크리트 내부의 미소균열 및 쪼개짐 균열의 성장을 억제하였기 때문으로 판단되었다.

Review of design parameters for FRP-RC members detailed according to ACI 440.1R-06

  • Jnaid, Fares;Aboutaha, Riyad
    • Computers and Concrete
    • /
    • 제11권2호
    • /
    • pp.105-121
    • /
    • 2013
  • This paper investigates the parameters that control the design of Fiber Reinforced Polymer (FRP) reinforced concrete flexural members proportioned following the ACI 440.1R-06. It investigates the critical parameters that control the flexural design, such as the deflection limits, crack limits, flexural capacity, concrete compressive strength, beam span and cross section, and bar diameter, at various Mean-Ambient Temperatures (MAT). The results of this research suggest that the deflection and cracking requirements are the two most controlling limits for FRP reinforced concrete flexural members.

Cyclic behavior of steel I-beams modified by a welded haunch and reinforced with GFRP

  • Egilmez, O. Ozgur;Alkan, Deniz;Ozdemir, Timur
    • Steel and Composite Structures
    • /
    • 제9권5호
    • /
    • pp.419-444
    • /
    • 2009
  • Flange and web local buckling in beam plastic hinge regions of steel moment frames can prevent beam-column connections from achieving adequate plastic rotations under earthquake-induced forces. Reducing the flange-web slenderness ratios (FSR/WSR) of beams is the most effective way in mitigating local member buckling as stipulated in the latest seismic design specifications. However, existing steel moment frame buildings with beams that lack the adequate slenderness ratios set forth for new buildings are vulnerable to local member buckling and thereby system-wise instability prior to reaching the required plastic rotation capacities specified for new buildings. This paper presents results from a research study investigating the cyclic behavior of steel I-beams modified by a welded haunch at the bottom flange and reinforced with glass fiber reinforced polymers at the plastic hinge region. Cantilever I-sections with a triangular haunch at the bottom flange and flange slenderness ratios higher then those stipulated in current design specifications were analyzed under reversed cyclic loading. Beam sections with different depth/width and flange/web slenderness ratios (FSR/WSR) were considered. The effect of GFRP thickness, width, and length on stabilizing plastic local buckling was investigated. The FEA results revealed that the contribution of GFRP strips to mitigation of local buckling increases with increasing depth/width ratio and decreasing FSR and WSR. Provided that the interfacial shear strength of the steel/GFRP bond surface is at least 15 MPa, GFRP reinforcement can enable deep beams with FSR of 8-9 and WSR below 55 to maintain plastic rotations in the order of 0.02 radians without experiencing any local buckling.

Experimental investigation on UHPC beams reinforced with GFRP and steel rebars and comparison with prediction equations

  • Parvin, Yousef Abbasi;Shaghaghi, Taleb Moradi;Pourbaba, Masoud;Mirrezaei, Seyyed Saeed;Zandi, Yousef
    • Advances in concrete construction
    • /
    • 제14권1호
    • /
    • pp.45-55
    • /
    • 2022
  • In this article, the flexural and shear capacity of ultra-high-performance fiber-reinforced concrete beams (UHPFRC) using two kinds of rebars, including GFRP and steel rebars, are experimentally investigated. For this purpose, six UHPFRC beams (250 × 300 × 1650 mm) with three reinforcement ratios (ρ) of 0.64, 1.05, and 1.45 were constructed using 2% steel fibers by volume. Half of the specimens were made of UHPFRC reinforced with GFRP rebars, while the other half were reinforced with conventional steel rebars. All specimens were tested to failure in four-point bending. Both the load-deformation at mid-span and the failure pattern were studied. The results showed that utilizing GFRP bars increases the flexural strength of UHPFRC beams in comparison to those made of steel bars, but at the same time, it reduces the post-cracking strain hardening. Furthermore, by increasing the percentage of longitudinal bars, both the post-cracking strain hardening and load-bearing capacity increase. Comparing the experiment results with some of the available equations and provisions cited in the valid design codes reveals that some of the equations to predict the flexural strength of UHPFRC beams reinforced with conventional steel and GFRP bars are reasonably conservative, while Khalil and Tayfur model is un-conservative. This issue makes it essential to modify the presented equations in this research for predicting the flexural strength of UHPFRC beams using GFRP bars.

CuO nanoparticle 및 fiber 로 구성된 PPS 복합재료의 sliding 조건하의 transfer film 에관한 연구 (Study of transfer film in the sliding of nanoscale CuO-filled and fiber-reinforced polyphenylene sulfide (PPS) composites)

  • 조민행;;박혜영;김윤준
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.967-972
    • /
    • 2004
  • The role of transfer films formed during sliding of polymer composites against steel counterfaces was studied in terms of the tribological behaviors of composites. Four kinds of composites were included in this study: (1) unfilled PPS, (2) PPS+2%CuO, (3) PPS+2%CuO+5% carbon fiber (CF), and (4) PPS+2%CuO+15%Kevlar. The filler material CuO was in nanoscale particulate form and the reinforcing material was in the form of short fibers. The composites were prepared by compression molding at $310^{\circ}C$ and sliding tests were run in the pin-on-disk sliding configuration. The counterface was made of tool steel hardened to 55-60 HRC and finished to a surface roughness of 0.09-0.10 ${\mu}m$ Ra. Wear tests were run for 6 hrs at the sliding speed of 1 m/s and contact pressure of 0.65 MPa. Transfer films formed on the counterfaces during sliding were investigated using AFM and SEM. The results showed that as the transfer film became smooth and uniform, wear rate decreased. PPS+2%CuO+15%Kevlar composite showed the lowest steady state wear rate in this study and its transfer film showed the smoothest and the most uniform characteristics. The examination of worn surfaces of PPS+2%CuO composite using X-ray area scanning (dot mapping) showed back-transfer of steel counterface material to the polymer pin surface. This behavior is believed to strengthen the polymer pin surface during sliding thereby contributing to the decrease in wear rate.

  • PDF

순환 잔골재 및 굵은골재를 사용한 SFRC 보의 성능 평가 (Capacity Evaluation of SFRC Beams Using Recycled Fine and Coarse Aggregates)

  • 이현호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제21권2호
    • /
    • pp.122-129
    • /
    • 2017
  • 본 연구의 목적은 순환골재를 대량 사용하기 위한 것이다. 천연골재를 순환골재로 50% 치환한 보의 전단성능을 증진시키기 위하여 강섬유를 보강하였다. 강섬유 혼입율은 0%, 0.5%, 0.75% 및 1.0%이다. 실험 결과, 강섬유 혼입율 0.5%인 경우와 0.75%인 경우의 강도 및 변형능력이 비보강 대비 월등히 증진됨을 확인할 수 있었다. 기존 연구자의 전단강도식으로 실험체의 강도를 평가한 결과, Oh et al.(2008)의 전단강도식이 SFRC 보의 전단강도를 안전측으로 예측할 수 있는 것으로 평가되었다.

격자형 탄소섬유로 보강한 R/C보의 보강효과 (Reinforcement Effect of Reinforced Concrete Beams Strengthened with Grid-type Carbon Fiber Plastics)

  • 조병완;태기호;권오혁
    • 콘크리트학회논문집
    • /
    • 제15권3호
    • /
    • pp.377-385
    • /
    • 2003
  • 인장강도와 내방식성이 우수하고 콘크리트 구조물속에서 철근과의 정착성이 양호하여 콘크리트 구조물의 새로운 보강재로 사용되고 있는 탄소격자섬유의 보강효과를 검증하기 위하여 탄소격자섬유보강공법으로 보강한 철근콘크리트 보 시험체를 제작하여 정적 휨 파괴실험을 통해 보강효과 및 휨 파괴특성을 분석하였다. 강판이나 탄소섬유 압착공법에서 나타나는 계면박리(탈락)파괴 보다는 보수 몰탈의 고강도화로 휨균열의 진전에 의해 콘크리트 속에서 철근에 정착된 격자섬유 층에서의 균열이 지점부로 진행되어 파괴되는 내부 계면박리와 지간중앙에서 철근 항복후 격자와 연결된 앵커볼트의 항복으로 인한 탄소격자섬유 파괴, 그리고 격자섬유 항복후 취성적인 콘크리트 압축파괴 양상이 나타났다. 실험결과를 근거로 최소보강재량이 제시되었으며, 강도설계법을 근거로 격자섬유로 보강시 필요한 설계법이 제안되었다.

GFRP 보강근 콘크리트 보의 전단성능에 대한 실험적 고찰 (Experimental Study for Shear Strength of Fiber-Reinforced-Polymer Reinforced Concrete Beams)

  • 박종섭;박영환;유영준
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.57-60
    • /
    • 2008
  • 기존의 철근콘크리트 구조물 시스템에서 철근은 사용연한이 지날수록 염분 및 습기, 염화물 등 외부환경에 의해 부식된다. 이러한 철근의 부식은 최종적으로 콘크리트 구조물의 성능 저하와 수명 단축을 유발시키는 주요 원인이 되기 때문에 최근 Fiber Reinforced Polymers(FRP)를 이용하여 철근을 대체할 수 있는 보강근을 개발하고자 하는 연구가 활발히 진행 중이다. FRP 보강근 콘크리트 보의 전단강도에 대한 기존 연구에 따르면 FRP 보강근은 철근에 비해 탄성계수가 낮기 때문에 동일 하중 수준에서 철근 콘크리트보다 균열폭이 커지고 균열이 크게 진행하게 되어 전단강도도 감소하는 것으로 알려져 있다. 본 연구에서는 FRP 보강근 콘크리트 보의 전단강도를 실험적으로 측정하고 기존에 제시 된 선행 규준의 예측식을 실험값과의 비교를 통해 검증해보고자 하였다. 본 연구에서 수행한 실험결과에서는 전단경간비가 증가할수록 전단강도는 감소하는 것으로 나타났다.

  • PDF

강섬유의 형상, 길이 및 혼입율에 따른 고성능 섬유보강 시멘트 복합체의 휨 특성 평가 (Evaluation of flexural performance of high performance fiber reinforced cementitious composites according to fiber shape, aspect ratio and volume fraction)

  • 박기준;박정준;김성욱;이장화
    • 한국산학기술학회논문지
    • /
    • 제18권12호
    • /
    • pp.697-704
    • /
    • 2017
  • 고성능 섬유보강 시멘트 복합체(High-Performance Fiber-Reinforced Cement Composites, HPFRCC)는 내구성 및 연성이 우수할 뿐만 아니라, 강도발현이 뛰어나 구조부재 적용 시 단면을 상당히 감소시켜 자중을 줄일 수 있는 재료로 관심을 받고 있다. 이에 본 연구에서는 HPFRCC에 사용 가능한 다양한 강섬유 종류 및 강섬유의 특성에 따라 휨 실험을 수행하였으며, 휨 성능 분석을 통해 효율적인 섬유보강 방법을 모색하여 경제성을 향상시키고자 하였다. 따라서 보다 효율적인 섬유보강 방법을 찾기 위해 기존길이 13 mm 보다 긴 강섬유를 소성 변형시킨 갈고리형 강섬유, 비틀림 강섬유를 사용하여 섬유의 모양(shape), 형상비(aspect ratio) 혼입율에 대한 휨 특성을 평가하고 분석하고자 하였다. 실험결과 HPFRCC에 일자형태를 가지는 길이 19.5 mm의 강섬유를 1.5%만큼 혼입할 경우 기존에 많이 사용되고 있는 길이 13 mm의 일자형 강섬유를 2.0% 혼입하였을 때 보다 뛰어난 휨 성능을 나타내었다. 따라서 섬유량을 줄여줄 수 있기 때문에 보다 경제성이 우수한 강섬유 보강 HPFRCC를 제조할 수 있을 것으로 판단되었다.